{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,23]],"date-time":"2025-08-23T00:06:02Z","timestamp":1755907562287,"version":"3.44.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T00:00:00Z","timestamp":1740441600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T00:00:00Z","timestamp":1740441600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"crossref","award":["2022R1F1A1069218","2017R1A1A2A10000681","2020R1A2C1005009"],"award-info":[{"award-number":["2022R1F1A1069218","2017R1A1A2A10000681","2020R1A2C1005009"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100003710","name":"Korea Health Industry Development Institute","doi-asserted-by":"publisher","award":["HI17C0659"],"award-info":[{"award-number":["HI17C0659"]}],"id":[{"id":"10.13039\/501100003710","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Graefes Arch Clin Exp Ophthalmol"],"published-print":{"date-parts":[[2025,7]]},"DOI":"10.1007\/s00417-025-06783-z","type":"journal-article","created":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T13:42:46Z","timestamp":1740490966000},"page":"1907-1913","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of the clinical outcomes after manual capsulorhexis on one eye and precision pulse capsulotomy on the other eye"],"prefix":"10.1007","volume":"263","author":[{"given":"Ho Sik","family":"Hwang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyun Seung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0310-5663","authenticated-orcid":false,"given":"Eun Chul","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,2,25]]},"reference":[{"key":"6783_CR1","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/s0886-3350(13)80870-x","volume":"16","author":"HV Gimbel","year":"1990","unstructured":"Gimbel HV, Neuhann T (1990) Development, advantages, and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg 16:31\u201337. https:\/\/doi.org\/10.1016\/s0886-3350(13)80870-x","journal-title":"J Cataract Refract Surg"},{"key":"6783_CR2","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1097\/icu.0000000000000539","volume":"30","author":"WF Hu","year":"2019","unstructured":"Hu WF, Chen SH (2019) Advances in capsulorhexis. Curr Opin Ophthalmol 30:19\u201324. https:\/\/doi.org\/10.1097\/icu.0000000000000539","journal-title":"Curr Opin Ophthalmol"},{"key":"6783_CR3","doi-asserted-by":"publisher","first-page":"902","DOI":"10.1016\/j.jcrs.2017.04.037","volume":"43","author":"O Findl","year":"2017","unstructured":"Findl O, Hirnschall N, Draschl P, Wiesinger J (2017) Effect of manual capsulorhexis size and position on intraocular lens tilt, centration, and axial position. J Cataract Refract Surg 43:902\u2013908. https:\/\/doi.org\/10.1016\/j.jcrs.2017.04.037","journal-title":"J Cataract Refract Surg"},{"key":"6783_CR4","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1016\/j.ophtha.2013.09.049","volume":"121","author":"M Okada","year":"2014","unstructured":"Okada M, Hersh D, Paul E, van der Straaten D (2014) Effect of centration and circularity of manual capsulorrhexis on cataract surgery refractive outcomes. Ophthalmology 121:763\u2013770. https:\/\/doi.org\/10.1016\/j.ophtha.2013.09.049","journal-title":"Ophthalmology"},{"key":"6783_CR5","doi-asserted-by":"publisher","first-page":"16227","DOI":"10.1038\/srep16227","volume":"5","author":"H Lin","year":"2015","unstructured":"Lin H, Tan X, Lin Z, Chen J, Luo L, Wu X, Long E, Chen W, Liu Y (2015) Capsular outcomes differ with capsulorhexis sizes after pediatric cataract surgery: a randomized controlled trial. Sci Rep 5:16227. https:\/\/doi.org\/10.1038\/srep16227","journal-title":"Sci Rep"},{"key":"6783_CR6","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1016\/s0002-9394(99)00157-9","volume":"128","author":"EJ Hollick","year":"1999","unstructured":"Hollick EJ, Spalton DJ, Meacock WR (1999) The effect of capsulorhexis size on posterior capsular opacification: one-year results of a randomized prospective trial. Am J Ophthalmol 128:271\u2013279. https:\/\/doi.org\/10.1016\/s0002-9394(99)00157-9","journal-title":"Am J Ophthalmol"},{"key":"6783_CR7","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1097\/icu.0000000000000820","volume":"33","author":"AA Abbas","year":"2022","unstructured":"Abbas AA, Bu JJ, Chung J, Afshari NA (2022) Recent developments in anterior capsulotomy for cataract surgery. Curr Opin Ophthalmol 33:47\u201352. https:\/\/doi.org\/10.1097\/icu.0000000000000820","journal-title":"Curr Opin Ophthalmol"},{"key":"6783_CR8","doi-asserted-by":"publisher","first-page":"e18224","DOI":"10.1097\/md.0000000000018224","volume":"98","author":"SP Bang","year":"2019","unstructured":"Bang SP, Jun JH (2019) Comparison of postoperative axial stability of intraocular lens and capsulotomy parameters between precision pulse capsulotomy and continuous curvilinear capsulotomy: a prospective cohort study. Medicine (Baltimore) 98:e18224. https:\/\/doi.org\/10.1097\/md.0000000000018224","journal-title":"Medicine (Baltimore)"},{"key":"6783_CR9","doi-asserted-by":"publisher","first-page":"558","DOI":"10.3928\/1081597x-20110623-03","volume":"27","author":"K Kr\u00e1nitz","year":"2011","unstructured":"Kr\u00e1nitz K, Takacs A, Mih\u00e1ltz K, Kov\u00e1cs I, Knorz MC, Nagy ZZ (2011) Femtosecond laser capsulotomy and manual continuous curvilinear capsulorrhexis parameters and their effects on intraocular lens centration. J Refract Surg 27:558\u2013563. https:\/\/doi.org\/10.3928\/1081597x-20110623-03","journal-title":"J Refract Surg"},{"key":"6783_CR10","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/j.ophtha.2015.10.008","volume":"123","author":"DF Chang","year":"2016","unstructured":"Chang DF, Mamalis N, Werner L (2016) Precision pulse capsulotomy: preclinical safety and performance of a new capsulotomy technology. Ophthalmology 123:255\u2013264. https:\/\/doi.org\/10.1016\/j.ophtha.2015.10.008","journal-title":"Ophthalmology"},{"key":"6783_CR11","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1097\/j.jcrs.0000000000001109","volume":"49","author":"C Ifantides","year":"2023","unstructured":"Ifantides C, Sretavan D (2023) Automated precision pulse capsulotomy vs manual capsulorhexis in white cataracts: reduction in procedural time and resource utilization. J Cataract Refract Surg 49:392\u2013399. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001109","journal-title":"J Cataract Refract Surg"},{"key":"6783_CR12","doi-asserted-by":"publisher","first-page":"76","DOI":"10.18240\/ijo.2021.01.11","volume":"14","author":"JC Reddy","year":"2021","unstructured":"Reddy JC, Devta S, Vupparaboina KK, Ali MH, Vaddavalli PK (2021) Early results of circularity and centration of capsulotomy prepared by three different methods. Int J Ophthalmol 14:76\u201382. https:\/\/doi.org\/10.18240\/ijo.2021.01.11","journal-title":"Int J Ophthalmol"},{"key":"6783_CR13","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.ophtha.2015.10.019","volume":"123","author":"VM Thompson","year":"2016","unstructured":"Thompson VM, Berdahl JP, Solano JM, Chang DF (2016) Comparison of manual, femtosecond laser, and precision pulse capsulotomy edge tear strength in paired human cadaver eyes. Ophthalmology 123:265\u2013274. https:\/\/doi.org\/10.1016\/j.ophtha.2015.10.019","journal-title":"Ophthalmology"},{"key":"6783_CR14","doi-asserted-by":"publisher","first-page":"68","DOI":"10.3109\/08820538.2012.754480","volume":"28","author":"EC Kim","year":"2013","unstructured":"Kim EC, Hwang HS, Kim MS (2013) Anterior capsular phimosis occluding the capsulorhexis opening after cataract surgery in a diabetic patient with high hemoglobin A1C. Semin Ophthalmol 28:68\u201371. https:\/\/doi.org\/10.3109\/08820538.2012.754480","journal-title":"Semin Ophthalmol"},{"key":"6783_CR15","doi-asserted-by":"publisher","first-page":"1184","DOI":"10.1016\/j.jcrs.2006.01.100","volume":"32","author":"Y Ebihara","year":"2006","unstructured":"Ebihara Y, Kato S, Oshika T, Yoshizaki M, Sugita G (2006) Posterior capsule opacification after cataract surgery in patients with diabetes mellitus. J Cataract Refract Surg 32:1184\u20131187. https:\/\/doi.org\/10.1016\/j.jcrs.2006.01.100","journal-title":"J Cataract Refract Surg"},{"issue":"Unit14","key":"6783_CR16","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1002\/0471142727.mb1415s102","volume":"14","author":"SM Hartig","year":"2013","unstructured":"Hartig SM (2013) Basic image analysis and manipulation in ImageJ. Curr Protoc Mol Biol Chapter 14(Unit14):15. https:\/\/doi.org\/10.1002\/0471142727.mb1415s102","journal-title":"Curr Protoc Mol Biol Chapter"},{"key":"6783_CR17","doi-asserted-by":"publisher","first-page":"606","DOI":"10.1016\/j.jcrs.2017.01.023","volume":"43","author":"K Waltz","year":"2017","unstructured":"Waltz K, Thompson VM, Quesada G (2017) Precision pulse capsulotomy: initial clinical experience in simple and challenging cataract surgery cases. J Cataract Refract Surg 43:606\u2013614. https:\/\/doi.org\/10.1016\/j.jcrs.2017.01.023","journal-title":"J Cataract Refract Surg"},{"key":"6783_CR18","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1016\/j.jcrs.2018.02.013","volume":"44","author":"V Thompson","year":"2018","unstructured":"Thompson V (2018) Streamlined method for anchoring cataract surgery and intraocular lens centration on the patient\u2019s visual axis. J Cataract Refract Surg 44:528\u2013533. https:\/\/doi.org\/10.1016\/j.jcrs.2018.02.013","journal-title":"J Cataract Refract Surg"},{"key":"6783_CR19","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.4103\/ijo.IJO_737_17","volume":"65","author":"DF Chang","year":"2017","unstructured":"Chang DF (2017) Zepto precision pulse capsulotomy: a new automated and disposable capsulotomy technology. Indian J Ophthalmol 65:1411\u20131414. https:\/\/doi.org\/10.4103\/ijo.IJO_737_17","journal-title":"Indian J Ophthalmol"},{"key":"6783_CR20","doi-asserted-by":"publisher","first-page":"1055","DOI":"10.1016\/j.jcrs.2018.07.001","volume":"44","author":"VM Thompson","year":"2018","unstructured":"Thompson VM (2018) Rate of complete capsulotomies from precision pulse technology. J Cataract Refract Surg 44:1055. https:\/\/doi.org\/10.1016\/j.jcrs.2018.07.001","journal-title":"J Cataract Refract Surg"},{"key":"6783_CR21","doi-asserted-by":"publisher","first-page":"429","DOI":"10.3341\/kjo.2021.0079","volume":"35","author":"JH An","year":"2021","unstructured":"An JH, Jun JH (2021) Thermal profile of pulse precision capsulotomy: in vivo and in vitro infrared thermography study. Korean J Ophthalmol 35:429\u2013437. https:\/\/doi.org\/10.3341\/kjo.2021.0079","journal-title":"Korean J Ophthalmol"},{"key":"6783_CR22","doi-asserted-by":"publisher","first-page":"1272","DOI":"10.4103\/ijo.IJO_146_18","volume":"66","author":"JA Kelkar","year":"2018","unstructured":"Kelkar JA, Mehta HM, Kelkar AS, Agarwal AA, Kothari AA, Kelkar SB (2018) Precision pulse capsulotomy in phacoemulsification: clinical experience in Indian eyes. Indian J Ophthalmol 66:1272\u20131277. https:\/\/doi.org\/10.4103\/ijo.IJO_146_18","journal-title":"Indian J Ophthalmol"},{"key":"6783_CR23","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1016\/j.jcrs.2017.12.027","volume":"44","author":"J Hooshmand","year":"2018","unstructured":"Hooshmand J, Abell RG, Allen P, Vote BJ (2018) Thermal capsulotomy: initial clinical experience, intraoperative performance, safety, and early postoperative outcomes of precision pulse capsulotomy technology. J Cataract Refract Surg 44:355\u2013361. https:\/\/doi.org\/10.1016\/j.jcrs.2017.12.027","journal-title":"J Cataract Refract Surg"},{"key":"6783_CR24","doi-asserted-by":"publisher","first-page":"1680","DOI":"10.1016\/j.jcrs.2019.07.028","volume":"45","author":"S Safuri","year":"2019","unstructured":"Safuri S, Duvdevan N, Socea S, Blumenthal EZ (2019) Precision pulse capsulotomy complicated by radial tear of the anterior capsule: a proposed mechanism. J Cataract Refract Surg 45:1680\u20131681. https:\/\/doi.org\/10.1016\/j.jcrs.2019.07.028","journal-title":"J Cataract Refract Surg"},{"key":"6783_CR25","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/j.ophtha.2017.09.018","volume":"125","author":"J Hooshmand","year":"2018","unstructured":"Hooshmand J, Abell RG, Goemann K, Davies PEJ, Vote BJ (2018) Ultrastructural integrity of human capsulotomies created by a thermal device. Ophthalmology 125:340\u2013344. https:\/\/doi.org\/10.1016\/j.ophtha.2017.09.018","journal-title":"Ophthalmology"},{"key":"6783_CR26","doi-asserted-by":"publisher","first-page":"101841","DOI":"10.1016\/j.ajoc.2023.101841","volume":"30","author":"AS Kalambe","year":"2023","unstructured":"Kalambe AS, Sano I, Sugihara K, Ishida A, Ichioka S, Shimada A, Tanito M (2023) Intra-operative challenges encountered using the zepto nano-pulse precision capsulotomy device. Am J Ophthalmol Case Rep 30:101841. https:\/\/doi.org\/10.1016\/j.ajoc.2023.101841","journal-title":"Am J Ophthalmol Case Rep"},{"key":"6783_CR27","doi-asserted-by":"publisher","first-page":"1701","DOI":"10.2147\/opth.S411454","volume":"17","author":"MC Vital","year":"2023","unstructured":"Vital MC, Jong KY, Trinh CE, Starck T, Sretavan D (2023) Endothelial cell loss following cataract surgery using continuous curvilinear capsulorhexis or precision pulse capsulotomy. Clin Ophthalmol 17:1701\u20131708. https:\/\/doi.org\/10.2147\/opth.S411454","journal-title":"Clin Ophthalmol"}],"container-title":["Graefe's Archive for Clinical and Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-025-06783-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00417-025-06783-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-025-06783-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T07:16:11Z","timestamp":1755846971000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00417-025-06783-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,25]]},"references-count":27,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["6783"],"URL":"https:\/\/doi.org\/10.1007\/s00417-025-06783-z","relation":{},"ISSN":["0721-832X","1435-702X"],"issn-type":[{"type":"print","value":"0721-832X"},{"type":"electronic","value":"1435-702X"}],"subject":[],"published":{"date-parts":[[2025,2,25]]},"assertion":[{"value":"5 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 February 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 February 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All the methods described adhered to the principles of the Declaration of Helsinki. The need for written informed consent was waived by the IRB of Bucheon St. Mary Hospital owing to the retrospective nature of this study, in accordance with the Ethical Guidelines for Medical and Biological Research Involving Human Subjects repealed from the Korean Government.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"This study was approved by the Institutional Review Board (IRB) of Bucheon St. Mary Hospital, (No. HC24RISI0017).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Institution"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}