{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T06:21:20Z","timestamp":1783405280021,"version":"3.54.6"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T00:00:00Z","timestamp":1774396800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T00:00:00Z","timestamp":1774396800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Graefes Arch Clin Exp Ophthalmol"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1007\/s00417-026-07209-0","type":"journal-article","created":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T07:27:45Z","timestamp":1774423665000},"page":"2031-2040","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Anterior chamber stability during phacoemulsification: comparing different phacoemulsification systems"],"prefix":"10.1007","volume":"264","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0332-7757","authenticated-orcid":false,"given":"Tommaso","family":"Rossi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giorgio","family":"Querzoli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Camilla Pellizzaro","family":"Deng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulia Rosari","family":"Deng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mariacristina","family":"Parravano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Placentino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberto","family":"Dell\u2019Omo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David H.","family":"Steel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario R.","family":"Romano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,25]]},"reference":[{"issue":"10374","key":"7209_CR1","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/S0140-6736(22)01839-6","volume":"401","author":"MV Cicinelli","year":"2023","unstructured":"Cicinelli MV, Buchan JC, Nicholson M, Varadaraj V, Khanna RC (2023) Cataracts. Lancet 401(10374):377\u2013389. https:\/\/doi.org\/10.1016\/S0140-6736(22)01839-6","journal-title":"Lancet"},{"issue":"1","key":"7209_CR2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjophth-2020-000464","volume":"6","author":"T Rossi","year":"2021","unstructured":"Rossi T, Romano MR, Iannetta D, Romano V, Gualdi L, D\u2019Agostino I, Ripandelli G (2021) Cataract surgery practice patterns worldwide: a survey. BMJ Open Ophthalmol 6(1):e000464. https:\/\/doi.org\/10.1136\/bmjophth-2020-000464","journal-title":"BMJ Open Ophthalmol"},{"issue":"1","key":"7209_CR3","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1097\/j.jcrs.0000000000001071","volume":"49","author":"H Suzuki","year":"2023","unstructured":"Suzuki H, Igarashi T, Takahashi H (2023) Effect of a new phacoemulsification and aspiration handpiece on anterior chamber stability. J Cataract Refract Surg 49(1):91\u201396. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001071","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"7209_CR4","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/j.ajo.2006.11.017","volume":"143","author":"D Georgescu","year":"2007","unstructured":"Georgescu D, Payne M, Olson RJ (2007) Objective measurement of postocclusion surge during phacoemulsification in human eye-bank eyes. Am J Ophthalmol 143(3):437\u2013440. https:\/\/doi.org\/10.1016\/j.ajo.2006.11.017","journal-title":"Am J Ophthalmol"},{"key":"7209_CR5","doi-asserted-by":"publisher","first-page":"2341","DOI":"10.2147\/OPTH.S416604","volume":"17","author":"RG Ricks","year":"2023","unstructured":"Ricks RG, Cardenas IA, Ungricht EL, Olson RJ, Pettey JH (2023) Effect of modified peristaltic phacoemulsification device on efficiency and post-occlusion pressure surge. Clin Ophthalmol 17:2341\u20132347. https:\/\/doi.org\/10.2147\/OPTH.S416604","journal-title":"Clin Ophthalmol"},{"issue":"8","key":"7209_CR6","doi-asserted-by":"publisher","first-page":"1424","DOI":"10.1016\/j.jcrs.2009.03.041","volume":"35","author":"YK Han","year":"2009","unstructured":"Han YK, Miller KM (2009) Comparison of vacuum rise time, vacuum limit accuracy, and occlusion break surge of 3 new phacoemulsification systems. J Cataract Refract Surg 35(8):1424\u20131429. https:\/\/doi.org\/10.1016\/j.jcrs.2009.03.041","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"7209_CR7","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1016\/s0886-3350(13)80946-7","volume":"19","author":"HR Wilbrandt","year":"1993","unstructured":"Wilbrandt HR, Wilbrandt TH (1993) Evaluation of intraocular pressure fluctuations with differing phacoemulsification approaches. J Cataract Refract Surg 19(2):223\u2013231. https:\/\/doi.org\/10.1016\/s0886-3350(13)80946-7","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"7209_CR8","doi-asserted-by":"publisher","first-page":"1976","DOI":"10.1016\/j.jcrs.2005.03.061","volume":"31","author":"J Zacharias","year":"2005","unstructured":"Zacharias J, Zacharias S (2005) Volume-based characterization of postocclusion surge. J Cataract Refract Surg 31(10):1976\u20131982. https:\/\/doi.org\/10.1016\/j.jcrs.2005.03.061","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"7209_CR9","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/j.jcrs.2017.10.052","volume":"44","author":"DW Dyk","year":"2018","unstructured":"Dyk DW, Miller KM (2018) Mechanical model of human eye compliance for volumetric occlusion break surge measurements. J Cataract Refract Surg 44(2):231. https:\/\/doi.org\/10.1016\/j.jcrs.2017.10.052","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"7209_CR10","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/s10792-025-03415-7","volume":"45","author":"MA Sallam","year":"2025","unstructured":"Sallam MA, Zaky KA (2025) Effect of anterior chamber depth on corneal endothelium following phacoemulsification among patients with different axial lengths. Int Ophthalmol 45(1):45. https:\/\/doi.org\/10.1007\/s10792-025-03415-7","journal-title":"Int Ophthalmol"},{"issue":"4","key":"7209_CR11","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1097\/j.jcrs.0000000000001359","volume":"50","author":"HA Scarfone","year":"2024","unstructured":"Scarfone HA, Rodriguez EC, Rufiner MG, Riera JJ, Fanego SE, Charles M, Albano R (2024) Vitreous-lens interface changes after cataract surgery using active fluidics and active sentry with high and low infusion pressure settings. J Cataract Refract Surg 50(4):333\u2013338. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001359","journal-title":"J Cataract Refract Surg"},{"key":"7209_CR12","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1159\/000452158","volume":"7","author":"JS Chang","year":"2016","unstructured":"Chang JS, Ng JC, Chan VK, Law AK (2016) Cataract surgery with a new fluidics control phacoemulsification system in nanophthalmic eyes. Case Rep Ophthalmol 7:218\u2013226","journal-title":"Case Rep Ophthalmol"},{"key":"7209_CR13","doi-asserted-by":"publisher","first-page":"768","DOI":"10.1016\/j.jcrs.2016.01.045","volume":"42","author":"JD Jensen","year":"2016","unstructured":"Jensen JD, Boulter T, Lambert NG, Zaugg B, Stagg BC, Pettey JH, Olson RJ (2016) Intraocular pressure study using monitored forced-infusion system phacoemulsification technology. J Cataract Refract Surg 42:768\u2013771","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"7209_CR14","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1097\/j.jcrs.0000000000001457","volume":"50","author":"MP Rauen","year":"2024","unstructured":"Rauen MP, Joiner H, Kohler RA, O\u2019Connor S (2024) Phacoemulsification using an active fluidics system at physiologic vs high intraocular pressure: impact on anterior and posterior segment physiology. J Cataract Refract Surg 50(8):822\u2013827. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001457","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"7209_CR15","doi-asserted-by":"publisher","first-page":"1977","DOI":"10.1080\/07853890.2022.2098375","volume":"54","author":"Y Luo","year":"2022","unstructured":"Luo Y, Li H, Chen W, Gao Y, Ma T, Ye Z, Li Z (2022) A prospective randomized clinical trial of active-fluidics versus gravity-fluidics system in phacoemulsification for age-related cataract (AGSPC). Ann Med 54(1):1977\u20131987. https:\/\/doi.org\/10.1080\/07853890.2022.2098375","journal-title":"Ann Med"},{"key":"7209_CR16","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.1097\/j.jcrs.0000000000000651","volume":"47","author":"KM Miller","year":"2021","unstructured":"Miller KM, Dyk DW, Yalamanchili S (2021) Experimental study of occlusion break surge volume in 3 different phacoemulsification systems. J Cataract Refract Surg 47:1466\u20131472","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"7209_CR17","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1080\/02713683.2019.1576205","volume":"44","author":"M Shajari","year":"2019","unstructured":"Shajari M, Herrmann K, B\u00fchren J, Vunnava P, Vounotrypidis E, M\u00fcller M, Al-Khateeb G, Kohnen T (2019) Anterior chamber angle, volume, and depth in a normative cohort-a retrospective cross-sectional study. Curr Eye Res 44(6):632\u2013637. https:\/\/doi.org\/10.1080\/02713683.2019.1576205","journal-title":"Curr Eye Res"},{"issue":"9","key":"7209_CR18","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1097\/j.jcrs.0000000000001242","volume":"49","author":"D Fanney","year":"2023","unstructured":"Fanney D, Layser GS, K AR, Kohlhammer S, K\u00fcbler C, Seibel BS (2023) Experimental study comparing 2 different phacoemulsification systems with intraocular pressure control during steady-state flow and occlusion break surge events. J Cataract Refract Surg 49(9):976\u2013981. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001242","journal-title":"J Cataract Refract Surg"},{"key":"7209_CR19","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1016\/j.jcrs.2018.02.026","volume":"44","author":"C Aravena","year":"2018","unstructured":"Aravena C, Dyk DW, Thorne A, Fanney D, Miller KM (2018) Aqueous volume loss associated with occlusion break surge in phacoemulsifiers from 4 different manufacturers. J Cataract Refract Surg 44:884\u2013888","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"7209_CR20","doi-asserted-by":"publisher","first-page":"3110","DOI":"10.1177\/11206721221087557","volume":"32","author":"K Mtanes","year":"2022","unstructured":"Mtanes K, Mimouni M, Sommer AC, Blumenthal EZ (2022) Stop & drop\"- a modified \u201cstop & chop\u201d phacoemulsification technique for cataract surgery. Eur J Ophthalmol 32(5):3110\u20133112. https:\/\/doi.org\/10.1177\/11206721221087557","journal-title":"Eur J Ophthalmol"},{"issue":"10","key":"7209_CR21","doi-asserted-by":"publisher","first-page":"1463","DOI":"10.1016\/j.jcrs.2013.04.033","volume":"39","author":"J Park","year":"2013","unstructured":"Park J, Yum HR, Kim MS, Harrison AR, Kim EC (2013) Comparison of phaco-chop, divide-and-conquer, and stop-and-chop phaco techniques in microincision coaxial cataract surgery. J Cataract Refract Surg 39(10):1463\u20131469. https:\/\/doi.org\/10.1016\/j.jcrs.2013.04.033","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"7209_CR22","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1097\/j.jcrs.0000000000001141","volume":"49","author":"T Sato","year":"2023","unstructured":"Sato T (2023) Efficacy and safety of the eight-chop technique in phacoemulsification for patients with cataract. J Cataract Refract Surg 49(5):479\u2013484. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001141","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"7209_CR23","doi-asserted-by":"publisher","first-page":"986","DOI":"10.1016\/j.jcrs.2008.02.029","volume":"34","author":"JA Davison","year":"2008","unstructured":"Davison JA (2008) Cumulative tip travel and implied followability of longitudinal and torsional phacoemulsification. J Cataract Refract Surg 34(6):986\u2013990. https:\/\/doi.org\/10.1016\/j.jcrs.2008.02.029","journal-title":"J Cataract Refract Surg"}],"container-title":["Graefe's Archive for Clinical and Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-026-07209-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00417-026-07209-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-026-07209-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T05:48:14Z","timestamp":1783403294000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00417-026-07209-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,25]]},"references-count":23,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["7209"],"URL":"https:\/\/doi.org\/10.1007\/s00417-026-07209-0","relation":{},"ISSN":["0721-832X","1435-702X"],"issn-type":[{"value":"0721-832X","type":"print"},{"value":"1435-702X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,25]]},"assertion":[{"value":"19 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 February 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 March 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 March 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Tommaso Rossi is a paid consultant for Beaver Visitec International, all other authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers\u2019 bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Financial disclosure"}},{"value":"Tommaso Rossi is a paid consultant of BVI medical.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interest"}}]}}