{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T16:19:38Z","timestamp":1783700378667,"version":"3.55.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T00:00:00Z","timestamp":1783641600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T00:00:00Z","timestamp":1783641600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100005690","name":"Universit\u00e4t des Saarlandes","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100005690","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Graefes Arch Clin Exp Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the refractive and anatomical lens position (ALP) predictability of the Aspira aXA (7\u00a0mm optic, cutout haptics) and Sensar One AAB00 IOLs (6\u00a0mm optic, C-loop haptics) in phacovitrectomy in a prospective, non-randomized cohort study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Preoperative biometry, 3-month subjective refraction, and swept-source optical coherence tomography were analyzed. ALP was the distance from the corneal endothelium to the IOL equator. Multivariate mixed-effects analysis was performed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 102 eyes from 97 patients were included (54 Aspira aXA; 48 Sensar One). The increase in the Aspira aXA lens thickness (LT) per diopter was 3.14 times greater than that of the Sensar One, yet showing a decrease from 1300 to 1100\u00a0\u03bcm at 23 D. The anterior chamber depth (ACD) increased from preoperatively to postoperatively\u2014to a greater extent for the Sensar One (1.74 vs. 1.50\u00a0mm,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;0.0001)\u2014while the axial length (AL) decreased, also to a greater degree for the Sensar One (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;0.05). Holladay 1 achieved the lowest mean absolute error (MAE) (Aspira aXA: 0.24; Sensar One: 0.23 D) and, with the SRK\/T and Haigis formulas, the highest accuracy within \u00b1\u20090.25 D. Preoperative ACD, AL, LT, and K\n                      <jats:sub>m<\/jats:sub>\n                      influenced the mean numerical error (MNE) and MAE inconsistently. The IOL type affected the MNE and MAE only for Haigis, whereas the ALP significantly influenced the MNE, but not the MAE, in all formulas except Hill-RBF and SRK\/T. Notably, the endotamponade type impacted the MNE and MAE in several modern formulas, but not in traditional vergence formulas. In contrast to AL and K\n                      <jats:sub>m<\/jats:sub>\n                      , the ACD and LT were strong predictors of ALP (Aspira aXA: R\u00b2 = 0.697, Sensar One: 0.881).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Preoperative ACD and LT reliably predict ALP. The Aspira aXA IOL introduces variability owing to its thickness profile. The endotamponade type exerts a significant influence. Traditional vergence formulas show greater robustness. Formula developments should integrate lens- and surgery-specific information.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00417-026-07340-y","type":"journal-article","created":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T03:21:29Z","timestamp":1783653689000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Refraction and anatomical lens position predictability in phacovitrectomy using a 7\u00a0mm optic with cutout haptics versus a 6\u00a0mm optic with C-loop haptics"],"prefix":"10.1007","author":[{"given":"Philip","family":"Wakili","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Colya N.","family":"Englisch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andr\u00e9","family":"Messias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clara E.","family":"Englisch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andr\u00e9","family":"Akansu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Annekatrin","family":"Rickmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clemens N.","family":"Rudolph","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna Theresa","family":"Fr\u00f6hlich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Berthold","family":"Seitz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Szurman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl T.","family":"Boden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,10]]},"reference":[{"key":"7340_CR1","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1007\/s00347-021-01533-y","volume":"119","author":"A Seifert","year":"2022","unstructured":"Seifert A, Seitz B, Wagenpfeil G, Ludwig K, Krause M (2022) [Phacovitrectomy-Influence of the timing of intraocular lens implantation on the corneal endothelium]. Ophthalmologie 119:591\u2013598. https:\/\/doi.org\/10.1007\/s00347-021-01533-y","journal-title":"Ophthalmologie"},{"key":"7340_CR2","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1159\/000355077","volume":"51","author":"F Kuhn","year":"2014","unstructured":"Kuhn F, Aylward B (2014) Rhegmatogenous retinal detachment: a reappraisal of its pathophysiology and treatment. Ophthalmic Res 51:15\u201331. https:\/\/doi.org\/10.1159\/000355077","journal-title":"Ophthalmic Res"},{"key":"7340_CR3","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1111\/aos.14367","volume":"98","author":"SNW Hertzberg","year":"2020","unstructured":"Hertzberg SNW, Veiby N, Bragadottir R, Eriksen K, Moe MC, Petrovski BE, Petrovski G (2020) Cost-effectiveness of the triple procedure - phacovitrectomy with posterior capsulotomy compared to phacovitrectomy and sequential procedures. Acta Ophthalmol 98:592\u2013602. https:\/\/doi.org\/10.1111\/aos.14367","journal-title":"Acta Ophthalmol"},{"key":"7340_CR4","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1016\/j.jcrs.2017.08.017","volume":"43","author":"CL Thiel","year":"2017","unstructured":"Thiel CL, Schehlein E, Ravilla T, Ravindran RD, Robin AL, Saeedi OJ, Schuman JS, Venkatesh R (2017) Cataract surgery and environmental sustainability: Waste and lifecycle assessment of phacoemulsification at a private healthcare facility. J Cataract Refract Surg 43:1391\u20131398. https:\/\/doi.org\/10.1016\/j.jcrs.2017.08.017","journal-title":"J Cataract Refract Surg"},{"key":"7340_CR5","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.ajo.2014.04.023","volume":"158","author":"KH Cho","year":"2014","unstructured":"Cho KH, Park IW, Kwon SI (2014) Changes in postoperative refractive outcomes following combined phacoemulsification and pars plana vitrectomy for rhegmatogenous retinal detachment. Am J Ophthalmol 158:251\u2013256. https:\/\/doi.org\/10.1016\/j.ajo.2014.04.023. e252","journal-title":"Am J Ophthalmol"},{"key":"7340_CR6","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1097\/IAE.0000000000000072","volume":"34","author":"R Rahman","year":"2014","unstructured":"Rahman R, Bong CX, Stephenson J (2014) Accuracy of intraocular lens power estimation in eyes having phacovitrectomy for rhegmatogenous retinal detachment. Retina 34:1415\u20131420. https:\/\/doi.org\/10.1097\/IAE.0000000000000072","journal-title":"Retina"},{"key":"7340_CR7","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1016\/j.oret.2023.03.017","volume":"7","author":"F Daud","year":"2023","unstructured":"Daud F, Daud K, Popovic MM, Yeung S, You Y, Cruz Pimentel M, Yan P (2023) Combined versus Sequential Pars Plana Vitrectomy and Phacoemulsification for Macular Hole and Epiretinal Membrane: A Systematic Review and Meta-Analysis. Ophthalmol Retina 7:721\u2013731. https:\/\/doi.org\/10.1016\/j.oret.2023.03.017","journal-title":"Ophthalmol Retina"},{"key":"7340_CR8","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1007\/s10792-022-02465-5","volume":"43","author":"A Mirshahi","year":"2023","unstructured":"Mirshahi A, Khalilipour E, Faghihi H, Riazi-Esfahani H, Mirshahi R, Mehrjardi HZ, Najibzadeh E, Amini A, Nabavi A (2023) Pars plana vitrectomy combined with phacoemulsification versus pars plana vitrectomy only for treatment of phakic rhegmatogenous retinal detachment: a systematic review and meta-analysis. Int Ophthalmol 43:697\u2013706. https:\/\/doi.org\/10.1007\/s10792-022-02465-5","journal-title":"Int Ophthalmol"},{"key":"7340_CR9","doi-asserted-by":"publisher","first-page":"e74","DOI":"10.1016\/j.ophtha.2020.06.055","volume":"128","author":"L Werner","year":"2021","unstructured":"Werner L (2021) Intraocular Lenses: Overview of Designs, Materials, and Pathophysiologic Features. Ophthalmology 128:e74\u2013e93. https:\/\/doi.org\/10.1016\/j.ophtha.2020.06.055","journal-title":"Ophthalmology"},{"key":"7340_CR10","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1111\/ceo.13650","volume":"48","author":"J Fernandez","year":"2020","unstructured":"Fernandez J, Sanchez-Garcia A, Rodriguez-Vallejo M, Pinero DP (2020) Systematic review of potential causes of intraocular lens opacification. Clin Exp Ophthalmol 48:89\u201397. https:\/\/doi.org\/10.1111\/ceo.13650","journal-title":"Clin Exp Ophthalmol"},{"key":"7340_CR11","doi-asserted-by":"publisher","unstructured":"Kilian R, Crincoli E, Rizzo C, Ripa M, Faraldi F, Lavia C, Tartaro R, Ceruti P, Casini G, Rizzo S, Savastano A (2022) Refractive error after combined phaco-vitrectomy: a multicentric study. Eur J Ophthalmol 11206721221143165. https:\/\/doi.org\/10.1177\/11206721221143165","DOI":"10.1177\/11206721221143165"},{"key":"7340_CR12","doi-asserted-by":"publisher","first-page":"1264","DOI":"10.1167\/iovs.08-2187","volume":"50","author":"S Pieh","year":"2009","unstructured":"Pieh S, Fiala W, Malz A, Stork W (2009) In vitro strehl ratios with spherical, aberration-free, average, and customized spherical aberration-correcting intraocular lenses. Invest Ophthalmol Vis Sci 50:1264\u20131270. https:\/\/doi.org\/10.1167\/iovs.08-2187","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"7340_CR13","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1007\/s00347-021-01504-3","volume":"119","author":"J Schrecker","year":"2022","unstructured":"Schrecker J, Seitz B, Langenbucher A (2022) [Performance of a new 7\u00a0mm intraocular lens with follow-up over 1.5 years]. Ophthalmologe 119:367\u2013373. https:\/\/doi.org\/10.1007\/s00347-021-01504-3","journal-title":"Ophthalmologe"},{"key":"7340_CR14","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.1080\/02713683.2021.1929329","volume":"46","author":"J Wendelstein","year":"2021","unstructured":"Wendelstein J, Laubichler P, Fischinger I, Mariacher S, Beka S, Mursch-Edlmayr A, Siska R, Langenbucher A, Bolz M (2021) Rotational Stability, Tilt and Decentration of a New IOL with a 7.0\u00a0mm Optic. Curr Eye Res 46:1673\u20131680. https:\/\/doi.org\/10.1080\/02713683.2021.1929329","journal-title":"Curr Eye Res"},{"key":"7340_CR15","doi-asserted-by":"publisher","first-page":"2111","DOI":"10.2147\/OPTH.S309302","volume":"15","author":"G Katz","year":"2021","unstructured":"Katz G, El Zhalka F, Veksler R, Ayalon A, Moisseiev E (2021) The Role of Anterior Chamber Depth on Post-operative Refractive Error After Phacovitrectomy. Clin Ophthalmol 15:2111\u20132115. https:\/\/doi.org\/10.2147\/OPTH.S309302","journal-title":"Clin Ophthalmol"},{"key":"7340_CR16","doi-asserted-by":"publisher","first-page":"2197","DOI":"10.1007\/s40123-024-00971-6","volume":"13","author":"Y Tanaka","year":"2024","unstructured":"Tanaka Y, Kamiya K, Igarahi A, Shoji N, Tsuchiya H, Takahashi S, Ishikawa E, Kozawa T (2024) Evaluation of the Accuracy of Intraocular Lens Power Calculation Formulas in Phacovitrectomy. Ophthalmol Ther 13:2197\u20132208. https:\/\/doi.org\/10.1007\/s40123-024-00971-6","journal-title":"Ophthalmol Ther"},{"key":"7340_CR17","doi-asserted-by":"publisher","first-page":"e0198824","DOI":"10.1371\/journal.pone.0198824","volume":"13","author":"S Schr\u00f6der","year":"2018","unstructured":"Schr\u00f6der S, Langenbucher A (2018) Relationship between effective lens position and axial position of a thick intraocular lens. PLoS ONE 13:e0198824. https:\/\/doi.org\/10.1371\/journal.pone.0198824","journal-title":"PLoS ONE"},{"key":"7340_CR18","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1007\/s00417-023-06208-9","volume":"262","author":"A Langenbucher","year":"2024","unstructured":"Langenbucher A, Szentmary N, Cayless A, Wendelstein J, Hoffmann P (2024) Prediction of IOL decentration, tilt and axial position using anterior segment OCT data. Graefes Arch Clin Exp Ophthalmol 262:835\u2013846. https:\/\/doi.org\/10.1007\/s00417-023-06208-9","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"7340_CR19","doi-asserted-by":"publisher","first-page":"1604224","DOI":"10.3389\/fmed.2025.1604224","volume":"12","author":"C Li","year":"2025","unstructured":"Li C, Luo B, Luo X, Zhang L, Li Q, Peng W (2025) Utilizing SS-OCT and 3D parametric modeling to enhance IOL position prediction in cataract patients with long axial length. Front Med (Lausanne) 12:1604224. https:\/\/doi.org\/10.3389\/fmed.2025.1604224","journal-title":"Front Med (Lausanne)"},{"key":"7340_CR20","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1007\/s00417-022-05771-x","volume":"261","author":"T Sato","year":"2023","unstructured":"Sato T, Iimori E, Hayashi K (2023) Prospective comparison of accuracy of intraocular lens calculation formulas in phacovitrectomy: a pilot study in a real-world clinical practice. Graefes Arch Clin Exp Ophthalmol 261:77\u201384. https:\/\/doi.org\/10.1007\/s00417-022-05771-x","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"7340_CR21","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.jcjo.2015.07.003","volume":"50","author":"YK Kim","year":"2015","unstructured":"Kim YK, Woo SJ, Hyon JY, Ahn J, Park KH (2015) Refractive outcomes of combined phacovitrectomy and delayed cataract surgery in retinal detachment. Can J Ophthalmol 50:360\u2013366. https:\/\/doi.org\/10.1016\/j.jcjo.2015.07.003","journal-title":"Can J Ophthalmol"},{"key":"7340_CR22","doi-asserted-by":"publisher","first-page":"1605","DOI":"10.1097\/IAE.0000000000003092","volume":"41","author":"G Moussa","year":"2021","unstructured":"Moussa G, Sachdev A, Mohite AA, Hero M, Ch\u2019ng SW, Andreatta W (2021) Assessing Refractive Outcomes and Accuracy of Biometry in Phacovitrectomy and Sequential Operations in Patients with Retinal Detachment Compared with Routine Cataract Surgery. Retina 41:1605\u20131611. https:\/\/doi.org\/10.1097\/IAE.0000000000003092","journal-title":"Retina"},{"key":"7340_CR23","doi-asserted-by":"publisher","first-page":"11319","DOI":"10.1038\/s41598-018-29553-w","volume":"8","author":"N Shiraki","year":"2018","unstructured":"Shiraki N, Wakabayashi T, Sakaguchi H, Nishida K (2018) Optical Biometry-Based Intraocular Lens Calculation and Refractive Outcomes after Phacovitrectomy for Rhegmatogenous Retinal Detachment and Epiretinal Membrane. Sci Rep 8:11319. https:\/\/doi.org\/10.1038\/s41598-018-29553-w","journal-title":"Sci Rep"},{"key":"7340_CR24","doi-asserted-by":"publisher","first-page":"15856","DOI":"10.1038\/s41598-018-34266-1","volume":"8","author":"TS Kang","year":"2018","unstructured":"Kang TS, Park HJ, Jo YJ, Kim JY (2018) Long-Term Reproducibility of Axial Length after Combined Phacovitrectomy in Macula-sparing Rhegmatogenous Retinal Detachment. Sci Rep 8:15856. https:\/\/doi.org\/10.1038\/s41598-018-34266-1","journal-title":"Sci Rep"},{"key":"7340_CR25","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.ophtha.2019.10.021","volume":"127","author":"N Shiraki","year":"2020","unstructured":"Shiraki N, Wakabayashi T, Sakaguchi H, Nishida K (2020) Effect of Gas Tamponade on the Intraocular Lens Position and Refractive Error after Phacovitrectomy: A Swept-Source Anterior Segment OCT Analysis. Ophthalmology 127:511\u2013515. https:\/\/doi.org\/10.1016\/j.ophtha.2019.10.021","journal-title":"Ophthalmology"},{"key":"7340_CR26","doi-asserted-by":"publisher","unstructured":"Kang TS, Shin YI, Ryu CK, Kim JY (2020) Two-year reproducibility of axial length measurements after combined phacovitrectomy for epiretinal membrane, and refractive outcomes. J Clin Med 9(11):3493. https:\/\/doi.org\/10.3390\/jcm9113493","DOI":"10.3390\/jcm9113493"},{"key":"7340_CR27","doi-asserted-by":"publisher","unstructured":"Akiyama A, Yokota H, Aso H, Hanazaki H, Iwasaki M, Yamagami S, Nagaoka T (2022) Comparison of postoperative stability of intraocular lenses after phacovitrectomy for rhegmatogenous retinal detachment. J Clin Med 11(12):3438. https:\/\/doi.org\/10.3390\/jcm11123438","DOI":"10.3390\/jcm11123438"},{"key":"7340_CR28","doi-asserted-by":"publisher","first-page":"1387987","DOI":"10.1155\/2021\/1387987","volume":"2021","author":"GU Auffarth","year":"2021","unstructured":"Auffarth GU, Fang H, Wang Q, Hengerer F, Khoramnia R, Son HS, Schickhardt S (2021) Silicone oil adhesion to hydrophobic acrylic intraocular lenses: a comparative laboratory study of a new versus an established hydrophobic acrylic intraocular lens material. J Ophthalmol 2021:1387987 https:\/\/doi.org\/10.1155\/2021\/1387987","journal-title":"J Ophthalmol"},{"issue":"11","key":"7340_CR29","doi-asserted-by":"publisher","first-page":"1943","DOI":"10.3390\/diagnostics13111943","volume":"13","author":"S Bopp","year":"2023","unstructured":"Bopp S, Ozdemir HB, Aktas Z, Khoramnia R, Yildirim TM, Schickhardt S, Auffarth GU, Ozdek S (2023) Clinical characteristics of patients with intraocular lens calcification after pars plana vitrectomy. Diagnostics (Basel) 13(11):1943. https:\/\/doi.org\/10.3390\/diagnostics13111943","journal-title":"Diagnostics (Basel)"},{"key":"7340_CR30","doi-asserted-by":"publisher","first-page":"e000157","DOI":"10.1136\/bmjophth-2018-000157","volume":"3","author":"AL Marcovich","year":"2018","unstructured":"Marcovich AL, Tandogan T, Bareket M, Eting E, Kaplan-Ashiri I, Bukelman A, Auffarth GU, Khoramnia R (2018) Opacification of hydrophilic intraocular lenses associated with vitrectomy and injection of intraocular gas. BMJ Open Ophthalmol 3:e000157. https:\/\/doi.org\/10.1136\/bmjophth-2018-000157","journal-title":"BMJ Open Ophthalmol"},{"key":"7340_CR31","doi-asserted-by":"publisher","first-page":"37","DOI":"10.3928\/23258160-20201223-07","volume":"52","author":"FH Oner","year":"2021","unstructured":"Oner FH, Ozturk T, Yaman A, Werner L (2021) Intraocular Lens Opacification Following Silicone Oil Endotamponade. Ophthalmic Surg Lasers Imaging Retina 52:37\u201343. https:\/\/doi.org\/10.3928\/23258160-20201223-07","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"7340_CR32","doi-asserted-by":"publisher","first-page":"e532","DOI":"10.3928\/1081597X-20250417-03","volume":"41","author":"CN Englisch","year":"2025","unstructured":"Englisch CN, Boden KT, Messias A, Szurman P, Rickmann A, Muller LJ, Lorenz AT, Seitz B, Langenbucher A, Wakili P (2025) Refraction predictability for a capsulotomy-fixated intraocular lens in femtosecond laser-assisted cataract surgery. J Refract Surg 41:e532\u2013e541. https:\/\/doi.org\/10.3928\/1081597X-20250417-03","journal-title":"J Refract Surg"},{"key":"7340_CR33","doi-asserted-by":"publisher","unstructured":"Englisch CN, Wakili P, Messias A, Szurman P, Rickmann A, Rudolph CN, Frohlich AT, Seitz B, Langenbucher A, Boden KT (2025) Anatomical lens position predictability for a capsulotomy-fixated intraocular lens in femtosecond laser-assisted cataract surgery. J Clin Med 14(17):6151. https:\/\/doi.org\/10.3390\/jcm14176151","DOI":"10.3390\/jcm14176151"},{"issue":"21","key":"7340_CR34","doi-asserted-by":"publisher","first-page":"6430","DOI":"10.3390\/jcm11216430","volume":"11","author":"Y Takahashi","year":"2022","unstructured":"Takahashi Y, Hirano T, Nakamura M, Chiku Y, Hoshiyama K, Akahane S, Akahane K, Murata T (2022) Temporal change in anterior chamber depth after combined vitrectomy and cataract surgery using different sizes of intraocular lens. J Clin Med 11(21):6430. https:\/\/doi.org\/10.3390\/jcm11216430","journal-title":"J Clin Med"},{"key":"7340_CR35","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1038\/s41598-020-79674-4","volume":"11","author":"D Schiano-Lomoriello","year":"2021","unstructured":"Schiano-Lomoriello D, Hoffer KJ, Abicca I, Savini G (2021) Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices. Sci Rep 11:983. https:\/\/doi.org\/10.1038\/s41598-020-79674-4","journal-title":"Sci Rep"}],"container-title":["Graefe's Archive for Clinical and Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-026-07340-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00417-026-07340-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-026-07340-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T16:02:09Z","timestamp":1783699329000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00417-026-07340-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,10]]},"references-count":35,"alternative-id":["7340"],"URL":"https:\/\/doi.org\/10.1007\/s00417-026-07340-y","relation":{},"ISSN":["0721-832X","1435-702X"],"issn-type":[{"value":"0721-832X","type":"print"},{"value":"1435-702X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,10]]},"assertion":[{"value":"18 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was obtained, and the local institutional board approved the study (Ethikkommission bei der \u00c4rztekammer des Saarlandes, 243\/14), which complied with the ethical principles of the Declaration of Helsinki. The study was designed as a non-interventional observational cohort study without allocation to specific treatments beyond routine clinical care. Prospective trial registration was therefore not performed.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics statement"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Clinical trial number"}}]}}