{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T21:37:30Z","timestamp":1792013850665,"version":"4.4.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2015,6,4]],"date-time":"2015-06-04T00:00:00Z","timestamp":1433376000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Pioneer corporation"},{"name":"Pioneer corporation"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Appl Physiol"],"published-print":{"date-parts":[[2015,10]]},"DOI":"10.1007\/s00421-015-3197-6","type":"journal-article","created":{"date-parts":[[2015,6,4]],"date-time":"2015-06-04T03:11:38Z","timestamp":1433387498000},"page":"2167-2176","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Orthostatic response of cephalic blood flow using a mini laser Doppler blood flowmeter and hemodynamics of a new active standing test"],"prefix":"10.1007","volume":"115","author":[{"given":"Masaki","family":"Goma","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshinori","family":"Kimura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroki","family":"Shimura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiro","family":"Kaneshige","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuro","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masashi","family":"Kikuchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuyuki","family":"Terada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2015,6,4]]},"reference":[{"key":"3197_CR1","doi-asserted-by":"crossref","first-page":"769","DOI":"10.3171\/jns.1982.57.6.0769","volume":"57","author":"R Aaslid","year":"1982","unstructured":"Aaslid R, Markwalder TM, Nornes H (1982) Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg 57:769\u2013774","journal-title":"J Neurosurg"},{"key":"3197_CR2","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1111\/j.1540-8167.2008.01257.x","volume":"19","author":"M Barantke","year":"2008","unstructured":"Barantke M, Krauss T, Ortak J, Lieb W, Reppel M, Burgdorf C, Pramstaller P, Schunkert H, Bonnemeier H (2008) Effects of gender and aging on differential autonomic responses to orthostatic maneuvers. J Cardiovasc Electrophysiol 19:1296\u20131303","journal-title":"J Cardiovasc Electrophysiol"},{"key":"3197_CR3","doi-asserted-by":"crossref","first-page":"2097","DOI":"10.1364\/AO.20.002097","volume":"20","author":"R Bonner","year":"1981","unstructured":"Bonner R, Nossal R (1981) Model for laser Doppler measurements of blood flow in tissue. Appl Opt 20:2097\u20132107","journal-title":"Appl Opt"},{"key":"3197_CR4","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1042\/cs0670321","volume":"67","author":"C Borst","year":"1984","unstructured":"Borst C, van Brederode J, Wieling W, van Montfrans G, Dunning AJ (1984) Mechanisms of initial blood pressure response to postural change. Clin Sci (Lond) 67:321\u2013327","journal-title":"Clin Sci (Lond)"},{"key":"3197_CR5","first-page":"H676","volume":"243","author":"C Borst","year":"1982","unstructured":"Borst C, Wieling W, van Brederode J, Hond A, de Rijk L, Dunning A (1982) Mechanisms of initial heart rate response to postural change. Am J Physiol 243:H676\u2013H681","journal-title":"Am J Physiol"},{"key":"3197_CR6","first-page":"875","volume":"69","author":"V Convertino","year":"1998","unstructured":"Convertino V, Tripp LD, Ludwig DA, Duff J, Chelette TL (1998) Female exposure to high G: chronic adaptations of cardiovascular functions. Aviat Space Environ Med 69:875\u2013882","journal-title":"Aviat Space Environ Med"},{"key":"3197_CR7","doi-asserted-by":"crossref","first-page":"2970","DOI":"10.1364\/AO.23.002970","volume":"23","author":"FFM Mul de","year":"1984","unstructured":"de Mul FFM, van Spijker J, van der Plas D, Greve J, Aarnoudse J, Smits T (1984) Mini laser-Doppler (blood) flow monitor with diode. Appl Opt 23:2970\u20132973","journal-title":"Appl Opt"},{"key":"3197_CR8","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1007\/s10286-002-0027-9","volume":"12","author":"M Hilz","year":"2002","unstructured":"Hilz M (2002) Assessment and evaluation of hereditary sensory and autonomic neuropathies with autonomic and neurophysiological examinations. Clin Auton Res 12:133\u2013143","journal-title":"Clin Auton Res"},{"key":"3197_CR9","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1093\/cvr\/24.3.214","volume":"24","author":"BP Imholz","year":"1990","unstructured":"Imholz BP, Settels JJ, van der Meiracker AH, Wesseling KH, Wieling W (1990) Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure. Cardiovasc Res 24:214\u2013221","journal-title":"Cardiovasc Res"},{"key":"3197_CR10","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1056\/NEJM198910053211407","volume":"321","author":"L Lipsitz","year":"1989","unstructured":"Lipsitz L (1989) Orthostatic hypotension in the elderly. N Engl J Med 321:952\u2013957","journal-title":"N Engl J Med"},{"key":"3197_CR11","first-page":"583","volume":"58","author":"P Low","year":"1983","unstructured":"Low P, Neumann C, Dyck P, Fealey R, Tuck R (1983) Evaluation of skin vasomotor reflexes by using laser Doppler velocimetry. Mayo Clin Proc 58:583\u2013592","journal-title":"Mayo Clin Proc"},{"key":"3197_CR12","doi-asserted-by":"crossref","first-page":"178","DOI":"10.3109\/03091909009009955","volume":"14","author":"AN Obeid","year":"1990","unstructured":"Obeid AN, Barnett NJ, Dougherty G, Ward G (1990) A critical review of laser Doppler flowmetry. J Med Eng Technol 14:178\u2013181","journal-title":"J Med Eng Technol"},{"key":"3197_CR13","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/S0168-8227(85)80032-2","volume":"1","author":"M Oimomi","year":"1985","unstructured":"Oimomi M, Nishimoto S, Matsumoto S, Hatanaka H, Ishikawa K, Baba S (1985) Evaluation of periflux blood flow measurement in diabetic patients with autonomic neuropathy. Diabetes Res Clin Pract 1:81\u201385","journal-title":"Diabetes Res Clin Pract"},{"key":"3197_CR14","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1002\/ca.1089","volume":"15","author":"ET Peuker","year":"2002","unstructured":"Peuker ET, Filler TJ (2002) The nerve supply of the human auricle. Clin Anat 15:35\u201337","journal-title":"Clin Anat"},{"key":"3197_CR15","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.autneu.2011.03.001","volume":"162","author":"JC Philips","year":"2011","unstructured":"Philips JC, Scheen AJ (2011) Squatting test: a posture to study and counteract cardiovascular abnormalities associated with autonomic dysfunction. Auton Neurosci 162:3\u20139","journal-title":"Auton Neurosci"},{"key":"3197_CR16","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1007\/s00421-003-0852-0","volume":"90","author":"CA Rickards","year":"2003","unstructured":"Rickards CA, Newman DG (2003) A comparative assessment of two techniques for investigating initial cardiovascular reflexes under acute orthostatic stress. Eur J Appl Physiol 90:449\u2013457","journal-title":"Eur J Appl Physiol"},{"key":"3197_CR17","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/BF00691245","volume":"57","author":"F Rossberg","year":"1988","unstructured":"Rossberg F, Penaz J (1988) Initial cardiovascular response on change of posture from squatting to standing. Eur J Appl Physiol Occup Physiol 57:93\u201397","journal-title":"Eur J Appl Physiol Occup Physiol"},{"key":"3197_CR18","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1093\/oso\/9780195073621.001.0001","volume-title":"Human cardiovascular control","author":"L Rowell","year":"1993","unstructured":"Rowell L (1993) Human cardiovascular control. Oxford University Press, New York, pp 443\u2013444"},{"key":"3197_CR19","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s10286-011-0140-8","volume":"22","author":"AJ Scheen","year":"2012","unstructured":"Scheen AJ, Philips JC (2012) Squatting test a dynamic postural manoeuvre to study baroreflex sensitivity. Clin Aut Res 22:35\u201341","journal-title":"Clin Aut Res"},{"key":"3197_CR20","doi-asserted-by":"crossref","first-page":"2067","DOI":"10.1109\/TBME.2006.877106","volume":"53","author":"AN Serov","year":"2006","unstructured":"Serov AN, Nieland J, Oosterbaan S, de Mul FFM, van Kranenburg H, Bekman HHPT, Steenbergen W (2006) Integrated optoelectronic probe including a vertical cavity surface emitting laser for laser Doppler perfusion monitoring. IEEE Trans Biomed Eng 53:2067\u20132074","journal-title":"IEEE Trans Biomed Eng"},{"key":"3197_CR21","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1159\/000071708","volume":"49","author":"X Shi","year":"2003","unstructured":"Shi X, Huang G, Smith S, Zhang R, Formes K (2003) Aging and arterial blood pressure variability during orthostatic challenge. Gerontology 49:279\u2013286","journal-title":"Gerontology"},{"key":"3197_CR22","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1063\/1.350267","volume":"70","author":"R Sprangers","year":"1991","unstructured":"Sprangers R, Wesseling K, Imholz A, Imholz B, Wieling W (1991) Initial blood pressure fall on stand up and exercise explained by changes in total peripheral resistance. J Appl Physiol 70:523\u2013530","journal-title":"J Appl Physiol"},{"key":"3197_CR23","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1111\/j.1475-097X.1996.tb00565.x","volume":"16","author":"H Tanaka","year":"1996","unstructured":"Tanaka H, Sj\u00f6berg BJ, Thulesius O (1996) Cardiac output and blood pressure during active and passive standing. Clin Physiol 16:157\u2013170","journal-title":"Clin Physiol"},{"key":"3197_CR24","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1152\/japplphysiol.91650.2008","volume":"107","author":"KN Thomas","year":"2009","unstructured":"Thomas KN, Cotter JD, Galvin SD, Williams MJA, Willie CK, Ainslie PN (2009) Initial orthostatic hypotension is unrelated to orthostatic tolerance in healthy young subjects. J Appl Physiol 107:506\u2013517","journal-title":"J Appl Physiol"},{"key":"3197_CR25","doi-asserted-by":"crossref","first-page":"R819","DOI":"10.1152\/ajpregu.00813.2004","volume":"288","author":"TN Thrasher","year":"2005","unstructured":"Thrasher TN (2005) Baroreflex control of sodium excretion and arterial pressure baroreceptors, baroreceptor unloading, and the long-term control of blood pressure. Am J Physiol Regul Integr Comp Physiol 288:R819\u2013R827","journal-title":"Am J Physiol Regul Integr Comp Physiol"},{"key":"3197_CR26","first-page":"H199","volume":"266","author":"K Toska","year":"1994","unstructured":"Toska K, Eriksen M, Wall\u00f8e L (1994) Short-term cardiovascular responses to a step decrease in peripheral conductance in humans. Am J Physiol 266:H199\u2013H211","journal-title":"Am J Physiol"},{"key":"3197_CR27","doi-asserted-by":"crossref","first-page":"H2102","DOI":"10.1152\/ajpheart.00571.2011","volume":"301","author":"ME Tschakovsky","year":"2011","unstructured":"Tschakovsky ME, Matusiak K, Vipond C, McVicar L (2011) Lower limb-localized vascular phenomena explain initial orthostatic hypotension upon standing from squat. Am J Physiol Heart Circ Physiol 301:H2102\u2013H2112","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"3197_CR28","doi-asserted-by":"crossref","first-page":"299","DOI":"10.5694\/j.1326-5377.2007.tb01248.x","volume":"187","author":"G Vaddadi","year":"2007","unstructured":"Vaddadi G, Lambert E, Corcoran SJ, Esler MD (2007) Postural syncope: mechanisms and management. Med J Aust 187:299\u2013304","journal-title":"Med J Aust"},{"key":"3197_CR29","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1097\/MBP.0b013e3280b083bd","volume":"12","author":"N Velde Van der","year":"2007","unstructured":"Van der Velde N, van den Meiracker AH, Stricker BHC, van der Cammen TJM (2007) Measuring orthostatic hypotension with the Finometer device: is a blood pressure drop of one heartbeat clinically relevant? Blood Press Monit 12:167\u2013171","journal-title":"Blood Press Monit"},{"key":"3197_CR30","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1113\/jphysiol.1996.sp021518","volume":"494","author":"W Wieling","year":"1996","unstructured":"Wieling W, Harms M, ten Harkel A, van Lieshout J, Sprangers R (1996) Circulatory response evoked by a 3\u00a0s bout of dynamic leg exercise in humans. J Physiol 494:601\u2013611","journal-title":"J Physiol"},{"key":"3197_CR31","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1042\/CS20060091","volume":"112","author":"W Wieling","year":"2007","unstructured":"Wieling W, Krediet CTP, van Dijk N, Linzer M, Tschakovsky ME (2007) Initial orthostatic hypotension: review of a forgotten condition. Clin Sci (Lond) 112:157\u2013165","journal-title":"Clin Sci (Lond)"},{"key":"3197_CR32","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1111\/j.1651-2227.1996.tb14090.x","volume":"85","author":"H Yamaguchi","year":"1996","unstructured":"Yamaguchi H, Tanaka H, Adachi K, Mino M (1996) Beat-to-beat blood pressure and heart rate responses to active standing in Japanese children. Acta Paediatr 85:577\u2013583","journal-title":"Acta Paediatr"}],"container-title":["European Journal of Applied Physiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00421-015-3197-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00421-015-3197-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00421-015-3197-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,9]],"date-time":"2024-06-09T10:06:00Z","timestamp":1717927560000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00421-015-3197-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,6,4]]},"references-count":32,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2015,10]]}},"alternative-id":["3197"],"URL":"https:\/\/doi.org\/10.1007\/s00421-015-3197-6","relation":{},"ISSN":["1439-6319","1439-6327"],"issn-type":[{"value":"1439-6319","type":"print"},{"value":"1439-6327","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,6,4]]}}}