{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T02:42:58Z","timestamp":1773196978378,"version":"3.50.1"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2022,3,30]],"date-time":"2022-03-30T00:00:00Z","timestamp":1648598400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,3,30]],"date-time":"2022-03-30T00:00:00Z","timestamp":1648598400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Langenbecks Arch Surg"],"DOI":"10.1007\/s00423-022-02504-w","type":"journal-article","created":{"date-parts":[[2022,3,30]],"date-time":"2022-03-30T20:03:01Z","timestamp":1648670581000},"page":"2105-2113","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["A negative pressure\u2013based visualization technique for abdominal Veress needle insertion"],"prefix":"10.1007","volume":"407","author":[{"given":"Takanobu","family":"Onoda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1532-6743","authenticated-orcid":false,"given":"Masanori","family":"Sato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kakeru","family":"Torii","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Inamori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eisaku","family":"Okada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Nozawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norihiko","family":"Shiiya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hidetoshi","family":"Wada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,3,30]]},"reference":[{"key":"2504_CR1","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1002\/bjs.4203","volume":"90","author":"TL Merlin","year":"2003","unstructured":"Merlin TL, Hiller JE, Maddern GJ, Jamieson GG, Brown AR, Kolbe A (2003) Systematic review of the safety and effectiveness of methods used to establish pneumoperitoneum in laparoscopic surgery. Br J Surg 90:668\u2013679","journal-title":"Br J Surg"},{"key":"2504_CR2","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1111\/j.0004-8666.2002.00246.x","volume":"42","author":"D Molloy","year":"2002","unstructured":"Molloy D, Kaloo PD, Cooper M, Nguyen TV (2002) Laparoscopic entry: a literature review and analysis of techniques and complications of primary port entry. Aust N Z J Obstet Gynaecol 42:246\u2013254","journal-title":"Aust N Z J Obstet Gynaecol"},{"key":"2504_CR3","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1016\/j.ajog.2003.09.035","volume":"190","author":"FW Jansen","year":"2004","unstructured":"Jansen FW, Kolkman W, Bakkum EA, de Kroon CD, Trimbos-Kemper TC, Trimbos JB (2004) Complications of laparoscopy: an inquiry about closed- versus open-entry technique. Am J Obstet Gynecol 190:634\u2013638","journal-title":"Am J Obstet Gynecol"},{"key":"2504_CR4","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1007\/s004640000381","volume":"15","author":"M Catarci","year":"2001","unstructured":"Catarci M, Carlini M, Gentileschi P, Santoro E (2001) Major and minor injuries during the creation of pneumoperitoneum. A multicenter study on 12,919 cases. Surg Endosc 15:566\u2013569","journal-title":"Surg Endosc"},{"key":"2504_CR5","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.jmig.2005.01.011","volume":"12","author":"B Teoh","year":"2005","unstructured":"Teoh B, Sen R, Abbott J (2005) An evaluation of four tests used to ascertain Veres needle placement at closed laparoscopy. J Minim Invasive Gynecol 12:153\u2013158","journal-title":"J Minim Invasive Gynecol"},{"key":"2504_CR6","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1590\/S0102-86502006000600006","volume":"21","author":"OC Azevedo","year":"2006","unstructured":"Azevedo OC, Azevedo JL, Sorbello AA, Miguel GP, Wilson Junior JL, Godoy AC (2006) Evaluation of tests performed to confirm the position of the Veress needle for creation of pneumoperitoneum in selected patients: a prospective clinical trial. Acta Cirurgica Brasileira 21:385\u2013391","journal-title":"Acta Cirurgica Brasileira"},{"key":"2504_CR7","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.gmit.2013.07.003","volume":"2","author":"J Thepsuwana","year":"2013","unstructured":"Thepsuwana J, Huang KG, Wilamarta M, Adlan A, Manvelyan V, Lee C (2013) Principles of safe abdominal entry in laparoscopic gynecologic surgery. J Minim Invasive Gynecol 2:105","journal-title":"J Minim Invasive Gynecol"},{"key":"2504_CR8","doi-asserted-by":"publisher","first-page":"4","DOI":"10.4103\/0974-1216.51902","volume":"1","author":"S Krishnakumar","year":"2009","unstructured":"Krishnakumar S, Tambe P (2009) Entry complications in laparoscopic surgery. Journal of Gynecological Endoscopy and Surgery 1:4\u201311","journal-title":"Journal of Gynecological Endoscopy and Surgery"},{"key":"2504_CR9","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1007\/s10397-008-0428-4","volume":"6","author":"C Burke","year":"2009","unstructured":"Burke C, Nathan E, Karthigasu K, Garry R, Hart R (2009) Laparoscopic entry\u2014the experience of a range of gynaecological surgeons. Gynecol Surg 6:125\u2013133","journal-title":"Gynecol Surg"},{"key":"2504_CR10","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1308\/rcsann.2017.0135","volume":"100","author":"A Pratap","year":"2018","unstructured":"Pratap A, Oleynikov D, Kothari V (2018) Real time ultrasound guided insertion of Veress needle in obese patients. Ann R Coll Surg Engl 100:158\u2013159","journal-title":"Ann R Coll Surg Engl"},{"key":"2504_CR11","doi-asserted-by":"publisher","first-page":"1376","DOI":"10.1089\/end.2013.0054","volume":"27","author":"MS Silay","year":"2013","unstructured":"Silay MS, Tepeler A, Sancaktutar AA, Kilincaslan H, Altay B, Erdem MR, Hatipoglu NK, Akcay M, Akman T, Armagan A (2013) The all-seeing needle instead of the Veress needle in pediatric urologic laparoscopy. J Endourol 27:1376\u20131380","journal-title":"J Endourol"},{"key":"2504_CR12","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1515\/cdbme-2019-0093","volume":"5","author":"A Schaufler","year":"2019","unstructured":"Schaufler A, S\u00fchn T, Esmaeili N, Boese A, Wex C, Croner R, Friebe M, Illanes A (2019) Automatic differentiation between Veress needle events in laparoscopic access using proximally attached audio signal characterization. Current Directions in Biomedical Engineering 5:369\u2013371","journal-title":"Current Directions in Biomedical Engineering"},{"key":"2504_CR13","doi-asserted-by":"publisher","first-page":"5857","DOI":"10.1007\/s00464-021-08603-x","volume":"35","author":"RR Postema","year":"2021","unstructured":"Postema RR, Cefai D, van Straten B, Miedema R, Hardjo LL, Dankelman J, Nickel F, Horeman-Franse T (2021) A novel Veress needle mechanism that reduces overshooting after puncturing the abdominal wall. Surg Endosc 35:5857\u20135866","journal-title":"Surg Endosc"},{"key":"2504_CR14","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/1749-7922-8-6","volume":"8","author":"F Coccolini","year":"2013","unstructured":"Coccolini F, Ansaloni L, Manfredi R, Campanati L, Poiasina E, Bertoli P, Capponi MG, Sartelli M, Di Saverio S, Cucchi M, Lazzareschi D, Pisano M, Catena F (2013) Peritoneal adhesion index (PAI): proposal of a score for the \u201cignored iceberg\u201d of medicine and surgery. World Journal of Emergency Surgery: WJES 8:6","journal-title":"World Journal of Emergency Surgery: WJES"},{"key":"2504_CR15","doi-asserted-by":"publisher","first-page":"1898","DOI":"10.1007\/s00464-011-2122-2","volume":"26","author":"H Wada","year":"2012","unstructured":"Wada H, Kimura T, Kawabe A, Sato M, Miyaki Y, Tochikubo J, Inamori K, Shiiya N (2012) Laparoscopic transabdominal preperitoneal inguinal hernia repair using needlescopic instruments: a 15-year, single-center experience in 317 patients. Surg Endosc 26:1898\u20131902","journal-title":"Surg Endosc"},{"key":"2504_CR16","first-page":"69","volume":"24","author":"MM Mukaka","year":"2012","unstructured":"Mukaka MM (2012) Statistics corner: a guide to appropriate use of correlation coefficient in medical research. Malawi Medical Journal: The Journal of Medical Association of Malawi 24:69\u201371","journal-title":"Malawi Medical Journal: The Journal of Medical Association of Malawi"},{"key":"2504_CR17","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1002\/pst.433","volume":"10","author":"PC Austin","year":"2011","unstructured":"Austin PC (2011) Optimal caliper widths for propensity-score matching when estimating differences in means and differences in proportions in observational studies. Pharm Stat 10:150\u2013161","journal-title":"Pharm Stat"},{"key":"2504_CR18","doi-asserted-by":"publisher","first-page":"3083","DOI":"10.1002\/sim.3697","volume":"28","author":"PC Austin","year":"2009","unstructured":"Austin PC (2009) Balance diagnostics for comparing the distribution of baseline covariates between treatment groups in propensity-score matched samples. Stat Med 28:3083\u20133107","journal-title":"Stat Med"},{"key":"2504_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.18637\/jss.v042.i07","volume":"42","author":"JS Sekhon","year":"2011","unstructured":"Sekhon JS (2011) Multivariate and propensity score matching software with automated balance optimization: the matching package for R. J Stat Softw 42:1\u201352","journal-title":"J Stat Softw"},{"key":"2504_CR20","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1038\/bmt.2012.244","volume":"48","author":"Y Kanda","year":"2013","unstructured":"Kanda Y (2013) Investigation of the freely available easy-to-use software \u201cEZR\u201d for medical statistics. Bone Marrow Transplant 48:452\u2013458","journal-title":"Bone Marrow Transplant"},{"key":"2504_CR21","first-page":"CD006583","volume":"1","author":"G Ahmad","year":"2019","unstructured":"Ahmad G, Baker J, Finnerty J, Phillips K, Watson A (2019) Laparoscopic entry techniques. The Cochrane Database of Systematic Reviews 1:CD006583","journal-title":"The Cochrane Database of Systematic Reviews"},{"key":"2504_CR22","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.ejogrb.2013.09.012","volume":"171","author":"R Angioli","year":"2013","unstructured":"Angioli R, Terranova C, De Cicco NC, Cafa EV, Damiani P, Portuesi R, Muzii L, Plotti F, Zullo MA, Panici PB (2013) A comparison of three different entry techniques in gynecological laparoscopic surgery: a randomized prospective trial. Eur J Obstet Gynecol Reprod Biol 171:339\u2013342","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"2504_CR23","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1007\/s00464-004-9010-y","volume":"18","author":"F Agresta","year":"2004","unstructured":"Agresta F, De Simone P, Ciardo LF, Bedin N (2004) Direct trocar insertion vs Veress needle in nonobese patients undergoing laparoscopic procedures: a randomized prospective single-center study. Surg Endosc 18:1778\u20131781","journal-title":"Surg Endosc"},{"key":"2504_CR24","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1111\/j.1471-0528.1997.tb11539.x","volume":"104","author":"FW Jansen","year":"1997","unstructured":"Jansen FW, Kapiteyn K, Trimbos-Kemper T, Hermans J, Trimbos JB (1997) Complications of laparoscopy: a prospective multicentre observational study. Br J Obstet Gynaecol 104:595\u2013600","journal-title":"Br J Obstet Gynaecol"},{"key":"2504_CR25","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1016\/S1074-3804(05)60277-0","volume":"10","author":"GA Vilos","year":"2003","unstructured":"Vilos GA, Vilos AG (2003) Safe laparoscopic entry guided by Veress needle CO2 insufflation pressure. J Am Assoc Gynecol Laparosc 10:415\u2013420","journal-title":"J Am Assoc Gynecol Laparosc"},{"key":"2504_CR26","first-page":"433","volume":"29","author":"GA Vilos","year":"2007","unstructured":"Vilos GA, Ternamian A, Dempster J, Laberge PY (2007) Laparoscopic entry: a review of techniques, technologies, and complications. Journal of Obstetrics and Gynaecology Canada: JOGC = Journal d\u2019Obstetrique et Gynecologie du Canada: JOGC 29:433\u2013447","journal-title":"Journal of Obstetrics and Gynaecology Canada: JOGC = Journal d'Obstetrique et Gynecologie du Canada: JOGC"},{"key":"2504_CR27","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1007\/s004640000105","volume":"14","author":"JW Briel","year":"2000","unstructured":"Briel JW, Plaisier PW, Meijer WS, Lange JF (2000) Is it necessary to lift the abdominal wall when preparing a pneumoperitoneum? A randomized study. Surg Endosc 14:862\u2013864","journal-title":"Surg Endosc"},{"key":"2504_CR28","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1016\/S1074-3804(05)60614-7","volume":"8","author":"GM Roy","year":"2001","unstructured":"Roy GM, Bazzurini L, Solima E, Luciano AA (2001) Safe technique for laparoscopic entry into the abdominal cavity. J Am Assoc Gynecol Laparosc 8:519\u2013528","journal-title":"J Am Assoc Gynecol Laparosc"},{"key":"2504_CR29","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/j.gmit.2017.04.001","volume":"6","author":"A Sakamoto","year":"2017","unstructured":"Sakamoto A, Kikuchi I, Shimanuki H, Tejima K, Saito J, Sakai K, Kumakiri J, Kitade M, Takeda S (2017) Initial closed trocar entry for laparoscopic surgery: technique, umbilical cosmesis, and patient satisfaction. Gynecology and Minimally Invasive Therapy 6:167\u2013172","journal-title":"Gynecology and Minimally Invasive Therapy"},{"key":"2504_CR30","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1177\/000313480106700308","volume":"67","author":"NC Sanchez","year":"2001","unstructured":"Sanchez NC, Tenofsky PL, Dort JM, Shen LY, Helmer SD, Smith RS (2001) What is normal intra-abdominal pressure? Am Surg 67:243\u2013248","journal-title":"Am Surg"},{"key":"2504_CR31","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1007\/s00464-008-9920-1","volume":"23","author":"A Shamiyeh","year":"2009","unstructured":"Shamiyeh A, Glaser K, Kratochwill H, Hormandinger K, Fellner F, Wayand WU, Zehetner J (2009) Lifting of the umbilicus for the installation of pneumoperitoneum with the Veress needle increases the distance to the retroperitoneal and intraperitoneal structures. Surg Endosc 23:313\u2013317","journal-title":"Surg Endosc"},{"key":"2504_CR32","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1007\/s00534-005-1024-x","volume":"13","author":"T Cakir","year":"2006","unstructured":"Cakir T, Tuney D, Esmaeilzadem S, Aktan AO (2006) Safe Veress needle insertion. J Hepatobiliary Pancreat Surg 13:225\u2013227","journal-title":"J Hepatobiliary Pancreat Surg"},{"key":"2504_CR33","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1007\/s00464-001-9166-7","volume":"16","author":"J Neudecker","year":"2002","unstructured":"Neudecker J, Sauerland S, Neugebauer E, Bergamaschi R, Bonjer HJ, Cuschieri A, Fuchs KH, Jacobi C, Jansen FW, Koivusalo AM, Lacy A, McMahon MJ, Millat B, Schwenk W (2002) The European Association for Endoscopic Surgery clinical practice guideline on the pneumoperitoneum for laparoscopic surgery. Surg Endosc 16:1121\u20131143","journal-title":"Surg Endosc"}],"container-title":["Langenbeck's Archives of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00423-022-02504-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00423-022-02504-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00423-022-02504-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,31]],"date-time":"2023-01-31T00:17:15Z","timestamp":1675124235000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00423-022-02504-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,30]]},"references-count":33,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2022,8]]}},"alternative-id":["2504"],"URL":"https:\/\/doi.org\/10.1007\/s00423-022-02504-w","relation":{},"ISSN":["1435-2451"],"issn-type":[{"value":"1435-2451","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,30]]},"assertion":[{"value":"15 November 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 March 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Hamamatsu University School of Medicine Independent Ethics Committee (Permission number: 20\u2013294). The requirement for patient consent was waived by the committee. Patient permission was requested on the institute\u2019s website, and opt-out consent was obtained from the patients.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors affirm that the participant provided informed consent for publication of the images in Fig.\u00a0and the supplemental movie.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}