{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T07:40:12Z","timestamp":1780731612313,"version":"3.54.1"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T00:00:00Z","timestamp":1560211200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T00:00:00Z","timestamp":1560211200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"NIHR Biomedical Research Centre based at Guy's and St Thomas NHS Foundation Trust and King's College London","award":["N\/A"],"award-info":[{"award-number":["N\/A"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Pediatr"],"published-print":{"date-parts":[[2019,8]]},"DOI":"10.1007\/s00431-019-03401-z","type":"journal-article","created":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T14:51:11Z","timestamp":1560264671000},"page":"1237-1242","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Diaphragm electromyography results at different high flow nasal cannula flow rates"],"prefix":"10.1007","volume":"178","author":[{"given":"Eleanor","family":"Jeffreys","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katie A","family":"Hunt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theodore","family":"Dassios","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8672-5349","authenticated-orcid":false,"given":"Anne","family":"Greenough","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,6,11]]},"reference":[{"key":"3401_CR1","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1111\/jpc.12277","volume":"49","author":"CL Collins","year":"2013","unstructured":"Collins CL, Hoberton JR, Konig K (2013) Comparison of the pharyngeal pressure provided by two heated humidified high flow nasal cannulae devices in premature infants. J Pediatr Child Health 49:554\u2013556","journal-title":"J Pediatr Child Health"},{"key":"3401_CR2","doi-asserted-by":"publisher","first-page":"F434","DOI":"10.1136\/archdischild-2016-312300","volume":"102","author":"CG de Waal","year":"2017","unstructured":"de Waal CG, Hutten GJ, Kraaijenga JV, de Jongh FH, van Kaam AH (2017) Electrical activity of the diaphragm during nCPAP and high flow nasal cannula. Arch Dis Child Fetal Neonatal Ed 102:F434\u2013F438","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"3401_CR3","doi-asserted-by":"publisher","first-page":"e29","DOI":"10.1097\/PCC.0b013e3181d9076d","volume":"12","author":"RA Hasan","year":"2011","unstructured":"Hasan RA, Habib RH (2011) Effects of flow rate and airleak at the nares and mouth opening on positive distending pressure delivery using commercially available high flow nasal cannula systems: a lung model study. Pediatr Crit Care Med 12:e29\u2013e33","journal-title":"Pediatr Crit Care Med"},{"key":"3401_CR4","doi-asserted-by":"crossref","first-page":"187","DOI":"10.3233\/NPM-2010-0114","volume":"3","author":"O Hochwald","year":"2010","unstructured":"Hochwald O, Osiovich H (2010) The use of high flow nasal cannulae in neonatal intensive care units: is clinical practice consistent with the evidence? J Neonatal-Perinatal Med 3:187\u2013191","journal-title":"J Neonatal-Perinatal Med"},{"key":"3401_CR5","doi-asserted-by":"publisher","first-page":"285","DOI":"10.4187\/respcare.04317","volume":"61","author":"NP Iyer","year":"2016","unstructured":"Iyer NP, Mhanna MJ (2016) Association between high flow nasal cannula and end expiratory esophageal pressures in premature infants. Respir Care 61:285\u2013290","journal-title":"Respir Care"},{"key":"3401_CR6","doi-asserted-by":"publisher","first-page":"1723","DOI":"10.1164\/ajrccm.163.7.2011060","volume":"163","author":"AH Jobe","year":"2001","unstructured":"Jobe AH, Bancalari E (2001) Bronchopulmonary dysplasia. Am J Respir Crit Care Med 163:1723\u20131729","journal-title":"Am J Respir Crit Care Med"},{"key":"3401_CR7","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1002\/ppul.23116","volume":"50","author":"JV Kraaijenga","year":"2015","unstructured":"Kraaijenga JV, Hutten GJ, de Jongh FH, van Kaam AH (2015) Transcutaneous electromyography of the diaphragm: a cardio-respiratory monitor for preterm infants. Pediatr Pulmonol 50:889\u2013895","journal-title":"Pediatr Pulmonol"},{"key":"3401_CR8","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.jpeds.2015.04.040","volume":"167","author":"JV Kraaijenga","year":"2015","unstructured":"Kraaijenga JV, Hutten GJ, de Jongh FH, van Kaam AH (2015) The effect of caffeine on diaphragmatic activity and tidal volume in preterm infants. J Pediatr 167:70\u201375","journal-title":"J Pediatr"},{"key":"3401_CR9","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1542\/peds.2007-0957","volume":"121","author":"ZJ Kubicka","year":"2008","unstructured":"Kubicka ZJ, Limauro J, Darnall RA (2008) Heated, humidified high-flow nasal cannula therapy: yet another way to deliver continuous positive airway pressure? Pediatrics 121:82\u201388","journal-title":"Pediatrics"},{"key":"3401_CR10","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.jpeds.2008.07.021","volume":"154","author":"AL Lampland","year":"2009","unstructured":"Lampland AL, Plumm B, Meyers PA, Worwa CT, Mammel MC (2009) Observational study of humidified high flow nasal cannula compared with nasal continuous positive airway pressure. J Pediatr 154:177\u2013182","journal-title":"J Pediatr"},{"key":"3401_CR11","doi-asserted-by":"publisher","first-page":"F315","DOI":"10.1136\/archdischild-2013-305855","volume":"99","author":"A Lavizzari","year":"2014","unstructured":"Lavizzari A, Veneroni C, Colnaghi M, Ciuffini F, Zannin E, Fumagalli M, Mosca F, Dellaca RL (2014) Respiratory mechanics during nCPAP and HHHFNC at equal distending pressures. Arch Dis Child Fetal Neonatal Ed 99:F315\u2013F320","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"3401_CR12","doi-asserted-by":"publisher","first-page":"1955","DOI":"10.1152\/jappl.2000.88.6.1955","volume":"88","author":"EJ Maarsingh","year":"2000","unstructured":"Maarsingh EJ, van Eykern L, Sprikkelman AB, Hoekstra MO, van Aalderen WM (2000) Respiratory muscle activity measured with a noninvasive EMG technique: technical aspects and reproducibility. J Appl Physiol 88:1955\u20131961","journal-title":"J Appl Physiol"},{"key":"3401_CR13","first-page":"131","volume":"2","author":"MJ O\u2019Brien","year":"1983","unstructured":"O\u2019Brien MJ, van Eykern LA, Prechtl H (1983) Monitoring respiratory activity in infants: a nonintrusive diaphragm EMG technique. Noninvasive Physiological Measurements, London, Academic 2:131\u2013177","journal-title":"Noninvasive Physiological Measurements, London, Academic"},{"key":"3401_CR14","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1111\/apa.14485","volume":"108","author":"A Oda","year":"2019","unstructured":"Oda A, Parikka V, Lehtonen L, Porres I, Soukka H (2019) Nasal high flow therapy decreased electrical activity of the diaphragm in preterm infants during the weaning phase. Acta Paediatr 108:253\u2013257","journal-title":"Acta Paediatr"},{"key":"3401_CR15","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1038\/sj.jp.7211530","volume":"26","author":"JG Saslow","year":"2006","unstructured":"Saslow JG, Aghai ZH, Nakhla TA, Hart JJ, Lawrysh R, Stahl GE, Pyon KH (2006) Work of breathing using high-flow nasal cannula in preterm infants. J Perinatol 26:476\u2013480","journal-title":"J Perinatol"},{"key":"3401_CR16","doi-asserted-by":"publisher","first-page":"F371","DOI":"10.1136\/archdischild-2016-310497","volume":"101","author":"S Shetty","year":"2016","unstructured":"Shetty S, Sundaresan A, Hunt K, Desai P, Greenough A (2016) Changes in the use of humidified high flow nasal cannula oxygen. Arch Dis Child Fetal Neonatal Ed 101:F371\u2013F372","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"3401_CR17","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1002\/ppul.22636","volume":"48","author":"EM Sivieri","year":"2013","unstructured":"Sivieri EM, Gerdes JS, Abbasi S (2013) Effect of HFNC flow rate, cannula size and nares diameter on generated airway pressures: an in vitro study. Pediatr Pulmonol 48:506\u2013514","journal-title":"Pediatr Pulmonol"},{"key":"3401_CR18","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1038\/sj.jp.7211828","volume":"27","author":"KL Spence","year":"2007","unstructured":"Spence KL, Murphy D, Kilian C, McGonigle R, Kilani RA (2007) High flow nasal cannula as a device to provide continuous positive airway pressure in infants. J Perinatol 27:772\u2013775","journal-title":"J Perinatol"},{"key":"3401_CR19","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1113\/jphysiol.1960.sp006446","volume":"151","author":"A Taylor","year":"1960","unstructured":"Taylor A (1960) The contribution of the intercostal muscles to the effort of respiration in man. J Physiol 151:390\u2013402","journal-title":"J Physiol"},{"key":"3401_CR20","doi-asserted-by":"crossref","unstructured":"Wilkinson D, Andersen C, O\u2019Donnell CP, De Paoli AG, Manley BJ (2016) High flow nasal cannula for respiratory support in preterm infants. Cochrane Database Syst Rev (2):CD006405","DOI":"10.1002\/14651858.CD006405.pub3"},{"key":"3401_CR21","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1038\/sj.jp.7211879","volume":"28","author":"DJ Wilkinson","year":"2008","unstructured":"Wilkinson DJ, Andersen CC, Smith K, Holberton J (2008) Pharyngeal pressure with high-flow nasal cannulae in premature infants. J Perinatol 28:42\u201347","journal-title":"J Perinatol"}],"container-title":["European Journal of Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00431-019-03401-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00431-019-03401-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00431-019-03401-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,9]],"date-time":"2020-06-09T23:13:36Z","timestamp":1591744416000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00431-019-03401-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,11]]},"references-count":21,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2019,8]]}},"alternative-id":["3401"],"URL":"https:\/\/doi.org\/10.1007\/s00431-019-03401-z","relation":{},"ISSN":["0340-6199","1432-1076"],"issn-type":[{"value":"0340-6199","type":"print"},{"value":"1432-1076","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,11]]},"assertion":[{"value":"10 April 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 May 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"AG has held grants from various manufacturers (Abbot Laboratories, MedImmune) and ventilator manufacturers (SLE). Professor Greenough has received honoraria for giving lectures and advising various manufacturers (Abbot Laboratories, MedImmune) and ventilator manufacturers (SLE). Professor Greenough is currently receiving a non-conditional educational grant from SLE.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Parents gave informed written consent.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"The views expressed are those of the author(s) and not necessarily those of the NHS, the NIHR, or the Department of Health.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Disclaimer"}}]}}