{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T10:55:09Z","timestamp":1782471309099,"version":"3.54.5"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2019,12,10]],"date-time":"2019-12-10T00:00:00Z","timestamp":1575936000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,12,10]],"date-time":"2019-12-10T00:00:00Z","timestamp":1575936000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Grupo de patolog\u00eda RESPIratoria y SURFactante de la SENeo","award":["IX Ayuda a la Investigaci\u00f3n Respisurf \/ Adolfo-Valls (2015)"],"award-info":[{"award-number":["IX Ayuda a la Investigaci\u00f3n Respisurf \/ Adolfo-Valls (2015)"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Pediatr"],"published-print":{"date-parts":[[2020,3]]},"DOI":"10.1007\/s00431-019-03503-8","type":"journal-article","created":{"date-parts":[[2019,12,10]],"date-time":"2019-12-10T18:03:53Z","timestamp":1576001033000},"page":"499-506","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["DCO2\/PaCO2 correlation on high-frequency oscillatory ventilation combined with volume guarantee using increasing frequencies in an animal model"],"prefix":"10.1007","volume":"179","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5654-0642","authenticated-orcid":false,"given":"Noelia","family":"Gonz\u00e1lez-Pacheco","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel","family":"S\u00e1nchez-Luna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristina","family":"Arribas-S\u00e1nchez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mart\u00edn","family":"Santos-Gonz\u00e1lez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristina","family":"Orden-Quinto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Tendillo-Cortijo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,12,10]]},"reference":[{"issue":"10","key":"3503_CR1","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.1002\/ppul.23759","volume":"52","author":"G Belteki","year":"2017","unstructured":"Belteki G, Lin B, Morley CJ (2017) Weight-correction of carbon dioxide diffusion coefficient (DCO2) reduces its inter-individual variability and improves its correlation with blood carbon dioxide levels in neonates receiving high-frequency oscillatory ventilation. Pediatr Pulmonol 52(10):1316\u20131322","journal-title":"Pediatr Pulmonol"},{"issue":"3","key":"3503_CR2","doi-asserted-by":"publisher","first-page":"1343","DOI":"10.1152\/jappl.1989.66.3.1343","volume":"66","author":"BR Boynton","year":"1989","unstructured":"Boynton BR, Hammond MD, Fredberg JJ, Buckley BG, Villanueva D, Frantz ID (1989) Gas exchange in healthy rabbits during high-frequency oscillatory ventilation. J Appl Physiol 66(3):1343\u20131351","journal-title":"J Appl Physiol"},{"issue":"3","key":"3503_CR3","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1002\/ppul.1950150310","volume":"15","author":"V Chan","year":"1993","unstructured":"Chan V, Greenough A, Milner AD (1993) The effect of frequency and mean airway pressure on volumen delivery during high-frequency oscillation. Pediatr Pulmonol 15(3):183\u2013186","journal-title":"Pediatr Pulmonol"},{"issue":"3","key":"3503_CR4","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1172\/JCI111061","volume":"72","author":"HL Dorkin","year":"1983","unstructured":"Dorkin HL, Stark AR, Werthammer JW, Strieder DJ, Fredberg JJ, Frantz ID 3rd (1983) Respiratory system impedance from 4 to 40 Hz in paralyzed intubated infants with respiratory disease. J Clin Invest 72(3):903\u2013910","journal-title":"J Clin Invest"},{"key":"3503_CR5","doi-asserted-by":"publisher","first-page":"S115","DOI":"10.1097\/01.CCM.0000155923.97849.6D","volume":"33","author":"AB Froese","year":"2005","unstructured":"Froese AB, Kinsella JP (2005) High-frequency oscillatory ventilation: lessons from the neonatal\/pediatric experience. Crit Care Med 33:S115\u2013S121","journal-title":"Crit Care Med"},{"issue":"4","key":"3503_CR6","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1038\/jp.2015.197","volume":"36","author":"N Gonz\u00e1lez-Pacheco","year":"2016","unstructured":"Gonz\u00e1lez-Pacheco N, S\u00e1nchez-Luna M, Ramos-Navarro C, Navarro-Pati\u00f1o N, de la Blanca AR (2016) Using very high frequencies with very low lung volumes during high frequency oscillatory ventilation to protect the immature lung. A pilot study. J Perinatol 36(4):306\u2013310","journal-title":"J Perinatol"},{"issue":"5","key":"3503_CR7","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1038\/s41372-019-0338-5","volume":"39","author":"N Gonz\u00e1lez-Pacheco","year":"2019","unstructured":"Gonz\u00e1lez-Pacheco N, S\u00e1nchez-Luna M, Chimenti-Camacho P, Santos-Gonz\u00e1lez M, Palau-Concejo P, Tendillo-Cortijo F (2019) Use of very low tidal volumes during high-frequency ventilation reduces ventilator lung injury. J Perinatol 39(5):730\u2013736","journal-title":"J Perinatol"},{"issue":"5","key":"3503_CR8","doi-asserted-by":"publisher","first-page":"e234","DOI":"10.1097\/PCC.0000000000000111","volume":"15","author":"ER Harcourt","year":"2014","unstructured":"Harcourt ER, John J, Dargaville PA, Zannin E, Davis PG, Tingay DG (2014) Pressure and flow waveform characteristics of eight high-frequency oscillators. Pediatr Crit Care Med 15(5):e234\u2013e240","journal-title":"Pediatr Crit Care Med"},{"issue":"6","key":"3503_CR9","doi-asserted-by":"publisher","first-page":"1306","DOI":"10.1152\/japplphysiol.00097.2016","volume":"121","author":"J Herrmann","year":"2016","unstructured":"Herrmann J, Tawhai MH, Kaczka DW (2016) Regional gas transport in the heterogeneous lung during oscillatory ventilation. J Appl Physiol 121(6):1306\u20131318","journal-title":"J Appl Physiol"},{"issue":"4","key":"3503_CR10","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1159\/000437204","volume":"108","author":"B Iscan","year":"2015","unstructured":"Iscan B, Duman N, Tuzun F, Kumral A, Ozkan H (2015) Impact of volume guarantee on high-frequency oscillatory ventilation in preterm infants: a randomized crossover clinical trial. Neonatology 108(4):277\u2013282","journal-title":"Neonatology"},{"issue":"9","key":"3503_CR11","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1097\/00003246-198409000-00003","volume":"12","author":"MJ Jaeger","year":"1984","unstructured":"Jaeger MJ, Kurzweg UH, Banner MJ (1984) Transport of gases in high-frequency ventilation. Crit Care Med 12(9):708\u2013710","journal-title":"Crit Care Med"},{"issue":"3","key":"3503_CR12","doi-asserted-by":"publisher","first-page":"F198","DOI":"10.1136\/fn.80.3.F198","volume":"80","author":"S Lee","year":"1999","unstructured":"Lee S, Alexander J, Blowes R, Ingram D, Milner AD (1999) Determination of resonance frequency of the respiratory system in respiratory distress s\u00edndrome. Arch Dis Child Fetal Neonatal Ed 80(3):F198\u2013F202","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"3503_CR13","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1038\/jp.2014.39","volume":"34","author":"A Mukerji","year":"2014","unstructured":"Mukerji A, Belik J, Sanchez-Luna M (2014) Bringing back the old: time to reevaluate the high-frequency ventilation strategy. J Perinatol 34:464\u2013467","journal-title":"J Perinatol"},{"key":"3503_CR14","doi-asserted-by":"publisher","first-page":"S135","DOI":"10.1097\/01.CCM.0000155789.52984.B7","volume":"33","author":"JJ Pillow","year":"2005","unstructured":"Pillow JJ (2005) High-frequency oscillatory ventilation: mechanisms of gas exchange and lung mechanics. Crit Care Med 33:S135\u2013S141","journal-title":"Crit Care Med"},{"issue":"23","key":"3503_CR15","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1056\/NEJM198112033052303","volume":"305","author":"TH Rossing","year":"1981","unstructured":"Rossing TH, Slutsky AS, Lehr JL, Drinker PA, Kamm R, Drazen JM (1981) Tidal volume and frequency dependence of carbon dioxide elimination by high-frequency ventilation. N Engl J Med 305(23):1375\u20131379","journal-title":"N Engl J Med"},{"key":"3503_CR16","doi-asserted-by":"publisher","unstructured":"S\u00e1nchez Luna M, Santos Gonz\u00e1lez M, Tendillo Cortijo F (2013) High-frequency oscillatory ventilation combined with volume guarantee in a neonatal animal model of respiratory distress syndrome. Crit Care Res Pract. https:\/\/doi.org\/10.1155\/2013\/593915","DOI":"10.1155\/2013\/593915"},{"issue":"10","key":"3503_CR17","doi-asserted-by":"publisher","first-page":"1343","DOI":"10.1007\/s00431-016-2770-2","volume":"175","author":"M S\u00e1nchez-Luna","year":"2016","unstructured":"S\u00e1nchez-Luna M, Gonz\u00e1lez-Pacheco N, Santos M, Blanco A, Orden C, Belik J, Tendillo FJ (2016) Effect of the I\/E ratio on CO2 removal during high-frequency oscillatory ventilation with volumen guarantee in a neonatal animal model of RDS. Eur J Pediatr 175(10):1343\u20131351","journal-title":"Eur J Pediatr"},{"issue":"4","key":"3503_CR18","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1002\/ppul.1950110410","volume":"11","author":"M Schindler","year":"1991","unstructured":"Schindler M, Seear M (1991) The effect of lung mechanics on gas transport during high-frequency oscillation. Pediatr Pulmonol 11(4):335\u2013339","journal-title":"Pediatr Pulmonol"},{"issue":"4456","key":"3503_CR19","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1126\/science.6771872","volume":"209","author":"AS Slutsky","year":"1980","unstructured":"Slutsky AS, Drazen FM, Ingram RH Jr, Kamm RD, Shapiro AH, Fredberg JJ, Lohring SH, Lehr J (1980) Effective pulmonary ventilation with small-volume oscillations at high frequency. Science 209(4456):609\u2013611","journal-title":"Science"},{"issue":"2","key":"3503_CR20","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/0034-5687(84)90151-8","volume":"58","author":"JW Watson","year":"1984","unstructured":"Watson JW, Jackson AC, Gillespie JR (1984) CO2 elimination and airway opening pressure during high frequency oscillation in dogs. Respir Physiol 58(2):235\u2013244","journal-title":"Respir Physiol"},{"issue":"6","key":"3503_CR21","doi-asserted-by":"publisher","first-page":"994","DOI":"10.1038\/pr.2017.151","volume":"82","author":"E Zannin","year":"2017","unstructured":"Zannin E, Dellaca RL, Dognini G, Marconi L, Perego M, Pillow JJ (2017) Effect of frequency on pressure cost of ventilation and gas exchange in newborns receiving high-frequency oscillatory ventilation. Pediatr Res 82(6):994\u2013999","journal-title":"Pediatr Res"}],"container-title":["European Journal of Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00431-019-03503-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00431-019-03503-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00431-019-03503-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,9]],"date-time":"2020-12-09T01:05:48Z","timestamp":1607475948000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00431-019-03503-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,10]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,3]]}},"alternative-id":["3503"],"URL":"https:\/\/doi.org\/10.1007\/s00431-019-03503-8","relation":{},"ISSN":["0340-6199","1432-1076"],"issn-type":[{"value":"0340-6199","type":"print"},{"value":"1432-1076","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,10]]},"assertion":[{"value":"14 May 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 September 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 October 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 December 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Manuel S\u00e1nchez-Luna declares receiving advisory board consulting fees from Dr\u00e4ger. The remaining authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All applicable international, national, and institutional guidelines for the care and use of animals were followed (2010\/63\/UE and RD 53\/2013). All procedures performed in studies involving animals were in accordance with the ethical standards of the institution or practice at which the studies were conducted (Ethics committee for animal research, Hospital Universitario Puerta de Hierro, Majadahonda, Madrid; CEEA: 004P\/2017).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}