{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T02:18:22Z","timestamp":1789611502246,"version":"build-2803163510"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2022,12,27]],"date-time":"2022-12-27T00:00:00Z","timestamp":1672099200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,12,27]],"date-time":"2022-12-27T00:00:00Z","timestamp":1672099200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Pediatr"],"DOI":"10.1007\/s00431-022-04777-1","type":"journal-article","created":{"date-parts":[[2022,12,27]],"date-time":"2022-12-27T15:04:10Z","timestamp":1672153450000},"page":"1083-1087","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Accuracy to detect neonatal hyperglycaemia using real-time continuous glucose monitoring during postoperative period"],"prefix":"10.1007","volume":"182","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8920-6819","authenticated-orcid":false,"given":"Mohammed Abdul","family":"Wasiq","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6061-6814","authenticated-orcid":false,"given":"Sushree Smita","family":"Behura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2742-6592","authenticated-orcid":false,"given":"Swaranjika","family":"Sahoo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0421-8747","authenticated-orcid":false,"given":"Santosh Kumar","family":"Panda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,12,27]]},"reference":[{"key":"4777_CR1","doi-asserted-by":"publisher","unstructured":"Arsenault D, Brenn M, Kim S, Gura K, Compher C, Simpser E (2012)\u00a0American Society for Parenteral and Enteral Nutrition Board of Directors, Puder M.\u00a0A.S.P.E.N. Clinical Guidelines: hyperglycemia and hypoglycemia in the neonate receiving parenteral nutrition. JPEN J Parenter Enteral Nutr 36(1):81\u201395.\u00a0https:\/\/doi.org\/10.1177\/0148607111418980","DOI":"10.1177\/0148607111418980"},{"issue":"9","key":"4777_CR2","first-page":"550","volume":"44","author":"VD Funtanilla","year":"2019","unstructured":"Funtanilla VD, Candidate P, Caliendo T, Hilas O (2019) Continuous glucose monitoring: a review of available systems. P T 44(9):550\u2013553","journal-title":"P T"},{"issue":"4","key":"4777_CR3","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1016\/j.jpedsurg.2012.10.003","volume":"48","author":"Y Wu","year":"2013","unstructured":"Wu Y, Pei J, Yang XD, Cheng ZD, Zhao YY, Xiang B (2013) Hyperglycemia and its association with clinical outcomes for patients in the pediatric intensive care unit after abdominal surgery. J Pediatr Surg 48(4):801\u2013805. https:\/\/doi.org\/10.1016\/j.jpedsurg.2012.10.003","journal-title":"J Pediatr Surg"},{"issue":"2","key":"4777_CR4","doi-asserted-by":"publisher","first-page":"183","DOI":"10.3233\/NPM-200535","volume":"14","author":"AR Bischoff","year":"2021","unstructured":"Bischoff AR, Grass B, Fan CS, Tomlinson C, Lee KS (2021) Risk factors for postoperative hyperglycemia in neonates. J Neonatal Perinatal Med 14(2):183\u2013191. https:\/\/doi.org\/10.3233\/NPM-200535","journal-title":"J Neonatal Perinatal Med"},{"issue":"8","key":"4777_CR5","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1007\/s13312-022-2575-5","volume":"59","author":"MA Wasiq","year":"2022","unstructured":"Wasiq MA, Behura SS, Sahoo S, Panda SK (2022) Comparison of continuous real time blood glucose measurement with venous laboratory blood glucose level in neonates during perioperative period. Indian Pediatr 59(8):620\u2013622","journal-title":"Indian Pediatr"},{"issue":"11","key":"4777_CR6","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1089\/dia.2014.0378","volume":"17","author":"T Bailey","year":"2015","unstructured":"Bailey T, Bode BW, Christiansen MP, Klaff LJ, Alva S (2015) The performance and usability of a factory-calibrated flash glucose monitoring system. Diabetes Technol Ther 17(11):787\u2013794. https:\/\/doi.org\/10.1089\/dia.2014.0378","journal-title":"Diabetes Technol Ther"},{"issue":"Suppl 1","key":"4777_CR7","doi-asserted-by":"publisher","first-page":"S234","DOI":"10.5152\/TurkPediatriArs.2018.01821","volume":"53","author":"DG \u015eim\u015fek","year":"2018","unstructured":"\u015eim\u015fek DG, Ecevit A, Hatipo\u011flu N, \u00c7oban A, Ar\u0131soy AE, Ba\u015f F, Mutlu GY, Bideci A, \u00d6zek E (2018) Neonatal hyperglycemia, which threshold value, diagnostic approach and treatment? Turkish Neonatal and Pediatric Endocrinology and Diabetes Societies consensus report. Turk Pediatri Ars 53(Suppl 1):S234\u2013S238. https:\/\/doi.org\/10.5152\/TurkPediatriArs.2018.01821","journal-title":"Turk Pediatri Ars"},{"issue":"2","key":"4777_CR8","doi-asserted-by":"publisher","first-page":"115","DOI":"10.5152\/TurkArchPediatr.2020.20183","volume":"56","author":"E Nishimura","year":"2021","unstructured":"Nishimura E, Oka S, Ozawa J, Tanaka K, Momose T, Kabe K, Namba F (2021) Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia. Turk Arch Pediatr 56(2):115\u2013120. https:\/\/doi.org\/10.5152\/TurkArchPediatr.2020.20183","journal-title":"Turk Arch Pediatr"},{"issue":"12","key":"4777_CR9","doi-asserted-by":"publisher","first-page":"1631","DOI":"10.2337\/dc17-1600","volume":"40","author":"T Danne","year":"2017","unstructured":"Danne T, Nimri R, Battelino T, Bergenstal RM, Close KL, DeVries JH et al (2017) International consensus on use of continuous glucose monitoring. Diabetes Care 40(12):1631\u20131640. https:\/\/doi.org\/10.2337\/dc17-1600","journal-title":"Diabetes Care"},{"issue":"5","key":"4777_CR10","doi-asserted-by":"publisher","first-page":"622","DOI":"10.2337\/diacare.10.5.622","volume":"10","author":"WL Clarke","year":"1987","unstructured":"Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL (1987) Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 10(5):622\u2013628. https:\/\/doi.org\/10.2337\/diacare.10.5.622","journal-title":"Diabetes Care"},{"issue":"8","key":"4777_CR11","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.2337\/diacare.23.8.1143","volume":"23","author":"JL Parkes","year":"2000","unstructured":"Parkes JL, Slatin SL, Pardo S, Ginsberg BH (2000) A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care 23(8):1143\u20131148. https:\/\/doi.org\/10.2337\/diacare.23.8.1143","journal-title":"Diabetes Care"},{"key":"4777_CR12","doi-asserted-by":"publisher","unstructured":"Mondal H (2021) Clarke Error Grid Analysis Template, figshare. Online resource.\u00a0https:\/\/doi.org\/10.6084\/m9.figshare.17166620.v1","DOI":"10.6084\/m9.figshare.17166620.v1"},{"key":"4777_CR13","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1136\/archdischild-2019-316871","volume":"105","author":"K Beardsall","year":"2020","unstructured":"Beardsall K, Thomson L, Elleri D et al (2020) Feasibility of automated insulin delivery guided by continuous glucose monitoring in preterm infants. Arch Dis Child Fetal Neonatal Ed 105:279\u2013284. https:\/\/doi.org\/10.1136\/archdischild-2019-316871","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"issue":"12","key":"4777_CR14","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2020-045335","volume":"10","author":"C Nava","year":"2020","unstructured":"Nava C, Modiano Hedenmalm A, Borys F, Hooft L, Bruschettini M, Jenniskens K (2020) Accuracy of continuous glucose monitoring in preterm infants: a systematic review and meta-analysis. BMJ Open 10(12):e045335. https:\/\/doi.org\/10.1136\/bmjopen-2020-045335","journal-title":"BMJ Open"},{"key":"4777_CR15","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1159\/000165980","volume":"95","author":"I Iglesias Platas","year":"2009","unstructured":"Iglesias Platas I, Thio Lluch M, Pociello Alminana N et al (2009) Continuous glucose monitoring in infants of very low birth weight. Neonatology 95:217\u2013223. https:\/\/doi.org\/10.1159\/000165980","journal-title":"Neonatology"},{"key":"4777_CR16","doi-asserted-by":"publisher","first-page":"1001","DOI":"10.1111\/ped.13961","volume":"61","author":"S Tomotaki","year":"2019","unstructured":"Tomotaki S, Toyoshima K, Shimokaze T et al (2019) Reliability of real-time continuous glucose monitoring in infants. Pediatr Int 61:1001\u20131006. https:\/\/doi.org\/10.1111\/ped.13961","journal-title":"Pediatr Int"},{"key":"4777_CR17","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1002\/14651858","volume":"2020","author":"A Galderisi","year":"2020","unstructured":"Galderisi A, Bruschettini M, Russo C et al (2020) Continuous glucose monitoring for the prevention of morbidity and mortality in preterm infants. Cochrane Database Syst Rev 2020:2. https:\/\/doi.org\/10.1002\/14651858","journal-title":"Cochrane Database Syst Rev"}],"container-title":["European Journal of Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00431-022-04777-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00431-022-04777-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00431-022-04777-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,17]],"date-time":"2023-03-17T12:05:12Z","timestamp":1679054712000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00431-022-04777-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,27]]},"references-count":17,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,3]]}},"alternative-id":["4777"],"URL":"https:\/\/doi.org\/10.1007\/s00431-022-04777-1","relation":{},"ISSN":["1432-1076"],"issn-type":[{"value":"1432-1076","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,27]]},"assertion":[{"value":"23 November 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Institutional Ethics Committee of the Kalinga Institute of Medical Sciences, KIIT University, has approved the study (KIMS\/KIIT\/IEC\/799\/2022). The patient identity is not exposed in this study; hence, individual patient consent was not taken for publication.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}