{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T20:24:33Z","timestamp":1789071873172,"version":"build-2803163510"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T00:00:00Z","timestamp":1755216000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T00:00:00Z","timestamp":1755216000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100015068","name":"Universidade de Santiago de Compostela","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100015068","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Pediatr"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Diabetic ketoacidosis (DKA) is a life-threatening complication of diabetes and a leading cause of Pediatric Intensive Care Unit (PICU) admissions. The use of continuous glucose monitoring (CGM) during the acute and critical phase of DKA has been rarely explored and remains uncertain due to concerns about accuracy and utility in a setting where frequent capillary glucose measurements are standard practice. Data was collected from medical records of patients admitted to the PICU with new-onset DKA as the initial presentation of type 1 diabetes (T1D). Mean absolute relative difference (MARD) and Clarke Error Grid (CEG) analysis were used to assess CGM accuracy. Data from 19 patients (mean age 9.9\u2009\u00b1\u20093.4\u00a0years) were included. Within the first 48\u00a0h, 16 hypoglycemic episodes were recorded, with CGM detecting 14 episodes and capillary glucose detecting two. A total of 238 matched pairs of\u00a0capillary and CGM interstitial glucose values were analyzed. Statistical analysis found capillary glucose values significantly higher than interstitial values (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.001). The overall MARD was 14.5% and CEG analysis indicated 89.1% of matched pairs within zones A and B.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:italic>Conclusions<\/jats:italic>\n                    : CGM might be a useful point-of-care tool that provides valuable information that may help clinicians to make timely management decisions. The ability of CGM to indicate trends in glucose fluctuations could be its main clinical advantage, particularly in anticipating and preventing potentially dangerous hypoglycemic events, thereby optimizing patient management and safety.\n                    <jats:table-wrap>\n                      <jats:table>\n                        <jats:tbody>\n                          <jats:tr>\n                            <jats:td align=\"left\">\n                              <jats:bold>What is Known:<\/jats:bold>\n                            <\/jats:td>\n                          <\/jats:tr>\n                          <jats:tr>\n                            <jats:td align=\"left\">\n                              \u2022\n                              <jats:italic>DKA emergencies require close glucose monitoring. Standard methods, such as capillary glucose monitoring or venous blood glucose measurements, have some limitations in terms of comfort, frequency, and trend detection.<\/jats:italic>\n                              \u2022\n                              <jats:italic>CGM is currently rarely used in PICU or DKA due to a lack of clinical trials, resulting in uncertainty about its accuracy in pediatric DKA. Additionally, CGM has not been FDA-approved for use in inpatients and to manage diabetes emergencies.<\/jats:italic>\n                            <\/jats:td>\n                          <\/jats:tr>\n                          <jats:tr>\n                            <jats:td align=\"left\">\n                              <jats:bold>What is New:<\/jats:bold>\n                            <\/jats:td>\n                          <\/jats:tr>\n                          <jats:tr>\n                            <jats:td align=\"left\">\n                              \u2022\n                              <jats:italic>CGM may benefit children with DKA from the onset.<\/jats:italic>\n                              \u2022\n                              <jats:italic>DKA management in PICUs by showing glucose trends and enabling hypoglycemia to be detected early, supporting timely interventions, reducing workload, and minimizing patient discomfort through fewer capillary punctures.<\/jats:italic>\n                            <\/jats:td>\n                          <\/jats:tr>\n                        <\/jats:tbody>\n                      <\/jats:table>\n                    <\/jats:table-wrap>\n                  <\/jats:p>","DOI":"10.1007\/s00431-025-06368-2","type":"journal-article","created":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T03:11:24Z","timestamp":1755227484000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Feasibility of continuous glucose monitoring in children with diabetic ketoacidosis: an exploratory observational study"],"prefix":"10.1007","volume":"184","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7257-6904","authenticated-orcid":false,"given":"Ver\u00f3nica","family":"Izquierdo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-3104-3595","authenticated-orcid":false,"given":"Nerea","family":"Afonso-Bouza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-9364-5550","authenticated-orcid":false,"given":"Eva Mar\u00eda","family":"Montoto-M\u00e9ndez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1806-5761","authenticated-orcid":false,"given":"Graciela","family":"G\u00f3mez-Silva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2841-4232","authenticated-orcid":false,"given":"Marcos","family":"Pazos-Couselo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3414-2771","authenticated-orcid":false,"given":"Antonio","family":"Rodr\u00edguez-Nu\u00f1ez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,15]]},"reference":[{"key":"6368_CR1","doi-asserted-by":"publisher","first-page":"1573","DOI":"10.2337\/dc20-0389","volume":"44","author":"ET Jensen","year":"2021","unstructured":"Jensen ET, Stafford JM, Saydah S, D\u2019agostino RB, Dolan LM, Lawrence JM, Marcovina S, Mayer-Davis EJ, Pihoker C, Rewers A, Dabelea D (2021) Increase in prevalence of diabetic ketoacidosis at diagnosis among youth with type 1 diabetes: the SEARCH for diabetes in youth study. Diabetes Care 44:1573\u20131578. https:\/\/doi.org\/10.2337\/dc20-0389","journal-title":"Diabetes Care"},{"key":"6368_CR2","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1111\/pedi.13406","volume":"23","author":"N Glaser","year":"2022","unstructured":"Glaser N, Fritsch M, Priyambada L, Rewers A, Cherubini V, Estrada S, Wolfsdorf JI, Codner E (2022) ISPAD clinical practice consensus guidelines 2022: diabetic ketoacidosis and hyperglycemic hyperosmolar state. Pediatr Diabetes 23:835\u2013856. https:\/\/doi.org\/10.1111\/pedi.13406","journal-title":"Pediatr Diabetes"},{"key":"6368_CR3","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1177\/1932296820959315","volume":"16","author":"E Tsotridou","year":"2022","unstructured":"Tsotridou E, Kotzapanagiotou E, Violaki A, Dimitriadou M, Svirkos M, Mantzafleri PE, Papadopoulou V, Sdougka M, Christoforidis A (2022) The effect of various, everyday practices on glucose levels in critically ill children. J Diabetes Sci Technol 16:81\u201387. https:\/\/doi.org\/10.1177\/1932296820959315","journal-title":"J Diabetes Sci Technol"},{"key":"6368_CR4","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1016\/j.pcl.2008.02.015","volume":"55","author":"J Orlowski","year":"2008","unstructured":"Orlowski J, Cramer C, Fiallos M (2008) Diabetic ketoacidosis in the pediatric ICU. Pediatr Clin North Am 55:577\u2013587. https:\/\/doi.org\/10.1016\/j.pcl.2008.02.015","journal-title":"Pediatr Clin North Am"},{"key":"6368_CR5","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1089\/DIA.2023.0012","volume":"25","author":"E Park","year":"2023","unstructured":"Park E, Kim M (2023) Clinical use of continuous glucose monitoring in critically ill pediatric patients with diabetic ketoacidosis. Diabetes Technol Ther 25:529\u2013537. https:\/\/doi.org\/10.1089\/DIA.2023.0012","journal-title":"Diabetes Technol Ther"},{"key":"6368_CR6","doi-asserted-by":"publisher","unstructured":"Barberena Moraes R, Vilaverde Perez A, Alegre P (2025) Continuous glucose monitor in adult diabetic ketoacidosis: a promising tool, CHEST Critical Care 3. https:\/\/doi.org\/10.1016\/j.chstcc.2024.100122","DOI":"10.1016\/j.chstcc.2024.100122"},{"key":"6368_CR7","doi-asserted-by":"publisher","first-page":"100109","DOI":"10.1016\/j.chstcc.2024.100109","volume":"3","author":"NL Haas","year":"2025","unstructured":"Haas NL, Ang L, Esfandiari NH, Khan AM, Cranford JA, Cohen A, Sell J, Abdel-Hamid M, Romanchik KE, Korley FK (2025) Analytical accuracy of a continuous glucose monitor in adult diabetic ketoacidosis. CHEST Critical Care 3:100109. https:\/\/doi.org\/10.1016\/j.chstcc.2024.100109","journal-title":"CHEST Critical Care"},{"key":"6368_CR8","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1089\/dia.2023.0375","volume":"26","author":"EC Cobry","year":"2024","unstructured":"Cobry EC, Pyle L, Waterman LA, Forlenza GP, Towers L, Karami AJ, Jost E, Berget C, Wadwa RP (2024) Accuracy of a continuous glucose monitor during pediatric type 1 diabetes inpatient admissions. Diabetes Technol Ther 26:119\u2013124. https:\/\/doi.org\/10.1089\/dia.2023.0375","journal-title":"Diabetes Technol Ther"},{"key":"6368_CR9","doi-asserted-by":"publisher","first-page":"924","DOI":"10.2337\/dci24-0020","volume":"47","author":"B Patham","year":"2024","unstructured":"Patham B, Kansara A, Sadhu AR (2024) Real-time continuous glucose monitoring in the intensive care unit: the fifth vital sign. Diabetes Care 47:924\u2013926. https:\/\/doi.org\/10.2337\/dci24-0020","journal-title":"Diabetes Care"},{"key":"6368_CR10","doi-asserted-by":"publisher","DOI":"10.1177\/19322968221140430","author":"T Pott","year":"2022","unstructured":"Pott T, Jimenez-Vega J, Parker J, Fitzgerald R (2022) Continuous glucose monitoring in pediatric diabetic ketoacidosis. J Diabetes Sci Technol. https:\/\/doi.org\/10.1177\/19322968221140430","journal-title":"J Diabetes Sci Technol"},{"issue":"1234","key":"6368_CR11","doi-asserted-by":"publisher","first-page":"2650","DOI":"10.1007\/s00125-024-06250-0","volume":"67","author":"MY O\u2019Connor","year":"2024","unstructured":"O\u2019Connor MY, Flint KL, Sabean A, Ashley A, Zheng H, Yan J, Steiner BA, Anandakugan N, Calverley M, Bartholomew R, Greaux E (2024) Accuracy of continuous glucose monitoring in the hospital setting: an observational study. Diabetologia 67(1234):2650\u20132659. https:\/\/doi.org\/10.1007\/s00125-024-06250-0","journal-title":"Diabetologia"},{"key":"6368_CR12","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1177\/19322968241241005","volume":"18","author":"L Ang","year":"2024","unstructured":"Ang L, Lin YK, Schroeder LF, Huang Y, DeGeorge CA, Arnold P, Akanbi F, Knotts S, DuBois E, Desbrough N, Qu Y, Freeman R, Esfandiari NH, Pop-Busui R, Gianchandani R (2024) Feasibility and performance of continuous glucose monitoring to guide computerized insulin infusion therapy in cardiovascular intensive care unit. J Diabetes Sci Technol 18:562\u2013569. https:\/\/doi.org\/10.1177\/19322968241241005","journal-title":"J Diabetes Sci Technol"},{"issue":"5","key":"6368_CR13","doi-asserted-by":"publisher","first-page":"953","DOI":"10.1007\/s10877-017-0086-z","volume":"32","author":"S Rijkenberg","year":"2018","unstructured":"Rijkenberg S, Van Steen SC, Devries JH, Van Der Voort PHJ (2018) Accuracy and reliability of a subcutaneous continuous glucose monitoring device in critically ill patients. J Clin Monit Comput 32:953\u2013964. https:\/\/doi.org\/10.1007\/s10877-017-0086-z","journal-title":"J Clin Monit Comput"},{"key":"6368_CR14","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1007\/S12020-022-03216-3","volume":"78","author":"W Huang","year":"2022","unstructured":"Huang W, Li S, Lu J, Shen Y, Wang Y, Wang Y, Feng K, Huang X, Zou Y, Hu L, Lu Y, Zhou J, Li Y (2022) Accuracy of the intermittently scanned continuous glucose monitoring system in critically ill patients: a prospective, multicenter, observational study. Endocrine 78:470\u2013475. https:\/\/doi.org\/10.1007\/S12020-022-03216-3","journal-title":"Endocrine"},{"key":"6368_CR15","doi-asserted-by":"publisher","first-page":"467","DOI":"10.2337\/dc09-1352","volume":"33","author":"U Holzinger","year":"2010","unstructured":"Holzinger U, Warszawska J, Kitzberger R, Wewalka M, Miehsler W, Herkner H, Madl C (2010) Real-time continuous glucose monitoring in critically ill patients: a prospective randomized trial. Diabetes Care 33:467\u2013472. https:\/\/doi.org\/10.2337\/dc09-1352","journal-title":"Diabetes Care"},{"key":"6368_CR16","doi-asserted-by":"publisher","first-page":"956","DOI":"10.2337\/dc23-1663","volume":"6","author":"B Voglov\u00e1Hagerf","year":"2024","unstructured":"Voglov\u00e1Hagerf B, Protus M, Nemetova L, Mraz M, Kieslichova E, Uchytilova E, Indrova V, Lelito J, Girman P, Haluz\u0131k M, Franekova J, Svirlochova V, Klonoff DC, Kohn MA, Jabor A (2024) Accuracy and feasibility of real-time continuous glucose monitoring in critically ill patients after abdominal surgery and solid organ transplantation. Diabetes Care 6:956\u2013963. https:\/\/doi.org\/10.2337\/dc23-1663","journal-title":"Diabetes Care"},{"key":"6368_CR17","doi-asserted-by":"publisher","first-page":"847","DOI":"10.2337\/DC20-2219","volume":"44","author":"S Agarwal","year":"2021","unstructured":"Agarwal S, Mathew J, Davis GM, Shephardson A, Levine A, Louard R, Urrutia A, Perez-Guzman C, Umpierrez GE, Peng L, Pasquel FJ (2021) Continuous glucose monitoring in the intensive care unit during the COVID-19 pandemic. Diabetes Care 44:847\u2013849. https:\/\/doi.org\/10.2337\/DC20-2219","journal-title":"Diabetes Care"},{"key":"6368_CR18","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1089\/dia.2023.0542","volume":"26","author":"LA Waterman","year":"2024","unstructured":"Waterman LA, Pyle L, Forlenza GP, Towers L, Karami AJ, Jost E, Berget C, Paul Wadwa R, Cobry EC (2024) Accuracy of a real-time continuous glucose monitor in pediatric diabetic ketoacidosis admissions. Diabetes Technol Ther 26:626\u2013632. https:\/\/doi.org\/10.1089\/dia.2023.0542","journal-title":"Diabetes Technol Ther"},{"key":"6368_CR19","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1097\/01.CCM.0000474737.88012.C0","volume":"43","author":"S Gangu","year":"2015","unstructured":"Gangu S, Tinsley C, Abd-Allah S (2015) 909: a study comparing the accuracy of CGM device to FSBG levels among PICU patients in DKA. Crit Care Med 43:229. https:\/\/doi.org\/10.1097\/01.CCM.0000474737.88012.C0","journal-title":"Crit Care Med"},{"key":"6368_CR20","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/S2352-4642(20)30367-9","volume":"5","author":"K Beardsall","year":"2021","unstructured":"Beardsall K, Thomson L, Guy C, Iglesias-Platas I, van Weissenbruch MM, Bond S, Allison A, Kim S, Petrou S, Pantaleo B, Hovorka R, Dunger D, Molnar Z, Barlow S, Baugh S, Johnson K, Uryn L, Spencer C, Hubbard M, Somisetty S, Adesiyan O, Kapadia J, Millar Y, Gurusamy K, Bibb L, Jones K, Heaver R, Muthukumar P, Nichols A, Johnson M, Pond J, Crowley P, Mellish C, Shah DD, Abraham M, Vincent P, Anil kumar S, Iringan A, Aninakwa B, Dalangin-Chalmers RA, de Lange A (2021) Real-time continuous glucose monitoring in preterm infants (REACT): an international, open-label, randomised controlled trial. Lancet Child Adolesc Health 5:265\u2013273. https:\/\/doi.org\/10.1016\/S2352-4642(20)30367-9","journal-title":"Lancet Child Adolesc Health"},{"key":"6368_CR21","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1097\/MOP.0000000000000592","volume":"30","author":"R Shah","year":"2018","unstructured":"Shah R, McKinlay CJD, Harding JE (2018) Neonatal hypoglycemia: continuous glucose monitoring. Curr Opin Pediatr 30:204\u2013208. https:\/\/doi.org\/10.1097\/MOP.0000000000000592","journal-title":"Curr Opin Pediatr"},{"key":"6368_CR22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.2337\/DB20181-1","volume":"2018","author":"IB Hirsch","year":"2018","unstructured":"Hirsch IB (2018) Introduction: History of glucose monitoring. Am Diabetes Assoc 2018:1\u20131. https:\/\/doi.org\/10.2337\/DB20181-1","journal-title":"Am Diabetes Assoc"},{"key":"6368_CR23","doi-asserted-by":"publisher","first-page":"S-45","DOI":"10.1089\/DIA.2008.0138","volume":"11","author":"W Clarke","year":"2009","unstructured":"Clarke W, Kovatchev B (2009) Statistical tools to analyze continuous glucose monitor data. Diabetes Technol Ther 11:S-45. https:\/\/doi.org\/10.1089\/DIA.2008.0138","journal-title":"Diabetes Technol Ther"},{"key":"6368_CR24","doi-asserted-by":"publisher","first-page":"622","DOI":"10.2337\/DIACARE.10.5.622","volume":"10","author":"WL Clarke","year":"1987","unstructured":"Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL (1987) Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 10:622\u2013628. https:\/\/doi.org\/10.2337\/DIACARE.10.5.622","journal-title":"Diabetes Care"},{"issue":"8","key":"6368_CR25","doi-asserted-by":"publisher","first-page":"1455","DOI":"10.1007\/S00125-024-06183-8","volume":"67","author":"GE Umpierrez","year":"2024","unstructured":"Umpierrez GE, Davis GM, ElSayed NA, Fadini GP, Galindo RJ, Hirsch IB, Klonoff DC, McCoy RG, Misra S, Gabbay RA, Bannuru RR, Dhatariya KK (2024) Hyperglycaemic crises in adults with diabetes: a consensus report. Diabetologia 67(8):1455\u20131479. https:\/\/doi.org\/10.1007\/S00125-024-06183-8","journal-title":"Diabetologia"},{"key":"6368_CR26","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.2337\/DIACARE.23.8.1143","volume":"23","author":"JL Parkes","year":"2000","unstructured":"Parkes JL, Slatin SL, Pardo S, Ginsberg BH (2000) A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care 23:1143\u20131148. https:\/\/doi.org\/10.2337\/DIACARE.23.8.1143","journal-title":"Diabetes Care"},{"key":"6368_CR27","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-024-07663-6","author":"CG Nielsen","year":"2024","unstructured":"Nielsen CG, Grigonyte-Daraskeviciene M, Olsen MT, M\u00f8ller MH, N\u00f8rgaard K, Perner A, M\u00e5rtensson J, Pedersen-Bjergaard U, Kristensen PL, Bestle MH (2024) Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review. Intensive Care Med. https:\/\/doi.org\/10.1007\/s00134-024-07663-6","journal-title":"Intensive Care Med"},{"key":"6368_CR28","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1177\/1932296820964264","volume":"14","author":"AR Sadhu","year":"2020","unstructured":"Sadhu AR, Serrano IA, Xu J, Nisar T, Lucier J, Pandya AR, Patham B (2020) Continuous glucose monitoring in critically ill patients with COVID-19: results of an emergent pilot study. J Diabetes Sci Technol 14:1065\u20131073. https:\/\/doi.org\/10.1177\/1932296820964264","journal-title":"J Diabetes Sci Technol"},{"key":"6368_CR29","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1097\/PCC.0B013E3181C59144","volume":"11","author":"RG Branco","year":"2010","unstructured":"Branco RG, Chavan A, Tasker RC (2010) Pilot evaluation of continuous subcutaneous glucose monitoring in children with multiple organ dysfunction syndrome. Pediatr Crit Care Med 11:415\u2013419. https:\/\/doi.org\/10.1097\/PCC.0B013E3181C59144","journal-title":"Pediatr Crit Care Med"},{"key":"6368_CR30","doi-asserted-by":"publisher","first-page":"1176","DOI":"10.1542\/PEDS.2006-0347","volume":"118","author":"HG Piper","year":"2006","unstructured":"Piper HG, Alexander JL, Shukla A, Pigula F, Costello JM, Laussen PC, Jaksic T, Agus MSD (2006) Real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery. Pediatrics 118:1176\u20131184. https:\/\/doi.org\/10.1542\/PEDS.2006-0347","journal-title":"Pediatrics"}],"container-title":["European Journal of Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00431-025-06368-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00431-025-06368-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00431-025-06368-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T14:04:49Z","timestamp":1765548289000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00431-025-06368-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,15]]},"references-count":30,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2025,9]]}},"alternative-id":["6368"],"URL":"https:\/\/doi.org\/10.1007\/s00431-025-06368-2","relation":{},"ISSN":["1432-1076"],"issn-type":[{"value":"1432-1076","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,15]]},"assertion":[{"value":"26 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 July 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 July 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 August 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was performed in line with the principles of the Declaration of Helsinki and was approved by the Ethics Committee for Research with Medicinal Products of Galicia (CEIm-G) (reference number 2024\/321).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"555"}}