{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T14:55:56Z","timestamp":1791298556527,"version":"4.1.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T00:00:00Z","timestamp":1791244800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T00:00:00Z","timestamp":1791244800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Pediatr"],"DOI":"10.1007\/s00431-026-07490-5","type":"journal-article","created":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T14:48:10Z","timestamp":1791298090000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy of non-invasive smartphone bilirubin measurements on neonates before and during phototherapy"],"prefix":"10.1007","volume":"185","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5318-9554","authenticated-orcid":false,"given":"Nikolina","family":"Zdraveska","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aco","family":"Kostovski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thilo","family":"Reich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deborah K.","family":"Hill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lobke M.","family":"Gierman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy M.","family":"Bahr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,6]]},"reference":[{"issue":"3","key":"7490_CR1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2022-058859","volume":"150","author":"AR Kemper","year":"2022","unstructured":"Kemper AR, Newman TB, Slaughter JL, Maisels MJ, Watchko JF, Downs SM et al (2022) Clinical practice guideline revision: management of hyperbilirubinemia in the neonate 35 or more weeks of gestation. Pediatrics 150(3):e2022058859","journal-title":"Pediatrics"},{"issue":"1","key":"7490_CR2","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1080\/20469047.2019.1598126","volume":"40","author":"SM Johnson","year":"2020","unstructured":"Johnson SM, Vasu V, Marseille C, Hill C, Janvier L, Toussaint P, Battersby C (2020) Validation of transcutaneous bilirubinometry during phototherapy for detection and monitoring of neonatal jaundice in a low-income setting. Paediatr Int Child Health 40(1):25\u201329","journal-title":"Paediatr Int Child Health"},{"issue":"5","key":"7490_CR3","first-page":"CD012660","volume":"5","author":"CI Okwundu","year":"2023","unstructured":"Okwundu CI, Olowoyeye A, Uthman OA, Smith J, Wiysonge CS, Bhutani VK et al (2023) Transcutaneous bilirubinometry versus total serum bilirubin measurement for newborns. Cochrane Database Syst Rev 5(5):CD012660","journal-title":"Cochrane Database Syst Rev"},{"issue":"9","key":"7490_CR4","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1038\/jp.2015.34","volume":"35","author":"MJ Maisels","year":"2015","unstructured":"Maisels MJ, Coffey MP, Kring E (2015) Transcutaneous bilirubin levels in newborns <35 weeks\u2019 gestation. J Perinatol 35(9):739\u2013744","journal-title":"J Perinatol"},{"issue":"12","key":"7490_CR5","doi-asserted-by":"publisher","first-page":"2532","DOI":"10.1111\/apa.15287","volume":"109","author":"A Aune","year":"2020","unstructured":"Aune A, Vartdal G, Bergseng H, Randeberg LL, Darj E (2020) Bilirubin estimates from smartphone images of neonates\u2019 skin correlated highly to serum bilirubin levels. Acta Paediatr 109(12):2532\u20132538","journal-title":"Acta Paediatr"},{"issue":"3","key":"7490_CR6","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2017-0312","volume":"140","author":"JA Taylor","year":"2017","unstructured":"Taylor JA, Stout JW, de Greef L, de Greef L, Goel M, Patel S et al (2017) Use of a smartphone app to assess neonatal jaundice. Pediatrics 140(3):e20170312","journal-title":"Pediatrics"},{"key":"7490_CR7","doi-asserted-by":"publisher","DOI":"10.2196\/40463","volume":"6","author":"A Aune","year":"2023","unstructured":"Aune A, Vartdal G, Jim\u00e9nez-D\u00edaz G, Gierman LM, Bergseng H, Darj E (2023) Iterative development, validation, and certification of a smartphone system to assess neonatal jaundice: development and usability study. JMIR Pediatr Parent 6:e40463","journal-title":"JMIR Pediatr Parent"},{"issue":"12","key":"7490_CR8","doi-asserted-by":"publisher","first-page":"e2450260","DOI":"10.1001\/jamanetworkopen.2024.50260","volume":"7","author":"AJH Ngeow","year":"2024","unstructured":"Ngeow AJH, Moosa AS, Tan MG, Zou L, Goh MMR, Lim GH et al (2024) Development and validation of a smartphone application for neonatal jaundice screening. JAMA Netw Open 7(12):e2450260","journal-title":"JAMA Netw Open"},{"key":"7490_CR9","doi-asserted-by":"publisher","first-page":"305022252513205","DOI":"10.1177\/30502225251320544","volume":"12","author":"G Jim\u00e9nez-D\u00edaz","year":"2025","unstructured":"Jim\u00e9nez-D\u00edaz G, Gierman LM, Keitsch M, Elizarrar\u00e1s-Rivas J, Silva-M\u00e9ndez RM, Infanti JJ, Marcuzzi A (2025) Validation of a mobile health device for neonatal jaundice screening: a cross-sectional study in a resource-limited setting in Mexico. Sage Open Pediatr 12:30502225251320544. https:\/\/doi.org\/10.1177\/30502225251320544","journal-title":"Sage Open Pediatr"},{"key":"7490_CR10","doi-asserted-by":"publisher","DOI":"10.3389\/fped.2026.1852961","volume":"14","author":"Y Zhao","year":"2026","unstructured":"Zhao Y, Xu A, Suo T, Zhang F, Chen M (2026) Agreement and diagnostic performance of a smartphone-based bilirubin assessment tool for screening neonatal hyperbilirubinemia. Front Pediatr 14:1852961. https:\/\/doi.org\/10.3389\/fped.2026.1852961","journal-title":"Front Pediatr"},{"issue":"11","key":"7490_CR11","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2022-061897","volume":"12","author":"LEH Westenberg","year":"2022","unstructured":"Westenberg LEH, van der Geest BAM, Lingsma HF, Nieboer D, Groen H, Vis JY et al (2022) Better assessment of neonatal jaundice at home (BEAT Jaundice @home): protocol for a prospective, multicentre diagnostic study. BMJ Open 12(11):e061897","journal-title":"BMJ Open"},{"issue":"1","key":"7490_CR12","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1186\/s12913-024-11141-6","volume":"24","author":"G Jim\u00e9nez-D\u00edaz","year":"2024","unstructured":"Jim\u00e9nez-D\u00edaz G, Aune A, Elizarrar\u00e1s-Rivas J, Gierman LM, Keitsch M, Marcuzzi A et al (2024) Neonatal jaundice detection in low-resource Mexican settings: possibilities and barriers for innovation with mobile health. BMC Health Serv Res 24(1):671","journal-title":"BMC Health Serv Res"},{"issue":"1","key":"7490_CR13","doi-asserted-by":"publisher","DOI":"10.1136\/bmjpo-2023-002242","volume":"9","author":"A Aune","year":"2025","unstructured":"Aune A, Jim\u00e9nez-D\u00edaz G, Gierman LM, Vartdal G, Reyes Berlanga M, Tusoy J et al (2025) Smartphone-based screening of neonatal jaundice in three populations in low- and middle-income countries: a cross-sectional study. BMJ Paediatr Open 9(1):e002242","journal-title":"BMJ Paediatr Open"},{"issue":"3","key":"7490_CR14","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1159\/000442195","volume":"109","author":"G Nagar","year":"2016","unstructured":"Nagar G, Vandermeer B, Campbell S, Kumar M (2016) Effect of phototherapy on the reliability of transcutaneous bilirubin devices in term and near-term infants: a systematic review and meta-analysis. Neonatology 109(3):203\u2013212","journal-title":"Neonatology"},{"key":"7490_CR15","doi-asserted-by":"publisher","first-page":"2819","DOI":"10.1007\/s00431-024-05516-4","volume":"183","author":"J Candel Pau","year":"2024","unstructured":"Candel Pau J, Maya Enero S, Garcia Garcia J, L\u00f3pez V\u00edlchez MA (2024) Transcutaneous bilirubin reliability during and after phototherapy depending on skin color. Eur J Pediatr 183:2819\u20132830. https:\/\/doi.org\/10.1007\/s00431-024-05516-4","journal-title":"Eur J Pediatr"},{"issue":"2","key":"7490_CR16","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1038\/s41372-019-0557-9","volume":"40","author":"U Costa Posada","year":"2020","unstructured":"Costa Posada U, Concheiro Guis\u00e1n A, T\u00e1boas Ledo MF et al (2020) Accuracy of transcutaneous bilirubin on covered skin in preterm and term newborns receiving phototherapy using a JM 105 bilirubinometer. J Perinatol 40(2):226\u2013231. https:\/\/doi.org\/10.1038\/s41372-019-0557-9","journal-title":"J Perinatol"},{"key":"7490_CR17","doi-asserted-by":"publisher","DOI":"10.3389\/fped.2024.1434770","volume":"12","author":"A Kallimath","year":"2024","unstructured":"Kallimath A, Patnaik S, Suryawanshi P, Deshmukh R, Malshe N (2024) The use of a simple and affordable skin patch for measurement of transcutaneous bilirubin levels in neonates during phototherapy. Front Pediatr 12:1434770. https:\/\/doi.org\/10.3389\/fped.2024.1434770","journal-title":"Front Pediatr"},{"issue":"6","key":"7490_CR18","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2023-062335","volume":"152","author":"L Ten Kate","year":"2023","unstructured":"Ten Kate L, van Oorschot T, Woolderink J, Teklenburg-Roord S, Bekhof J (2023) Transcutaneous bilirubin accuracy before, during, and after phototherapy: a meta-analysis. Pediatrics 152(6):e2023062335. https:\/\/doi.org\/10.1542\/peds.2023-062335","journal-title":"Pediatrics"},{"issue":"11","key":"7490_CR19","doi-asserted-by":"publisher","first-page":"5037","DOI":"10.1007\/s00431-024-05724-y","volume":"183","author":"N Thamwiriyakul","year":"2024","unstructured":"Thamwiriyakul N, Siripattanapipong P, Bowornkitiwong W, Chaweerat R, Ngerncham S (2024) Validity of transcutaneous bilirubin measurements during and after phototherapy in term and late preterm infants. Eur J Pediatr 183(11):5037\u20135041. https:\/\/doi.org\/10.1007\/s00431-024-05724-y","journal-title":"Eur J Pediatr"},{"issue":"5","key":"7490_CR20","doi-asserted-by":"publisher","first-page":"e1324","DOI":"10.1542\/peds.2014-1677","volume":"134","author":"J Grabenhenrich","year":"2014","unstructured":"Grabenhenrich J, Grabenhenrich L, B\u00fchrer C, Berns M (2014) Transcutaneous bilirubin after phototherapy in term and preterm infants. Pediatrics 134(5):e1324\u2013e1329. https:\/\/doi.org\/10.1542\/peds.2014-1677","journal-title":"Pediatrics"}],"container-title":["European Journal of Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00431-026-07490-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00431-026-07490-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00431-026-07490-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T14:48:11Z","timestamp":1791298091000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00431-026-07490-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,6]]},"references-count":20,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2026,11]]}},"alternative-id":["7490"],"URL":"https:\/\/doi.org\/10.1007\/s00431-026-07490-5","relation":{},"ISSN":["1432-1076"],"issn-type":[{"value":"1432-1076","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,6]]},"assertion":[{"value":"31 August 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 September 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 October 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 October 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Institutional Ethics Committee of the University Children\u2019s Hospital in Skopje, reference number 03\u20131671\/1, from 26.03.2025.","order":1,"name":"Ethics","label":"Ethics approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Written informed consent was obtained from the parents or legal guardians of all participants included in the study.","order":2,"name":"Ethics","label":"Consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable. This manuscript does not contain any individual person\u2019s identifiable data, images, or videos.","order":3,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"TR, DKH and LMG are employees of Picterus AS, the manufacturer of the Picterus JP device evaluated in this study. Picterus AS provided the Picterus JP application and calibration cards for research use and had input during study design, but had no role in data collection, analysis, or manuscript preparation. The remaining authors declare they have no competing interests.","order":4,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"807"}}