{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,2]],"date-time":"2026-08-02T12:45:08Z","timestamp":1785674708724,"version":"3.56.0"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2010,12,24]],"date-time":"2010-12-24T00:00:00Z","timestamp":1293148800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Surg Endosc"],"published-print":{"date-parts":[[2011,7]]},"DOI":"10.1007\/s00464-010-1527-7","type":"journal-article","created":{"date-parts":[[2010,12,23]],"date-time":"2010-12-23T20:49:22Z","timestamp":1293137362000},"page":"2382-2386","source":"Crossref","is-referenced-by-count":74,"title":["The importance of precompression time for secure stapling with a linear stapler"],"prefix":"10.1007","volume":"25","author":[{"given":"Shinya","family":"Nakayama","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suguru","family":"Hasegawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Nagayama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeru","family":"Kato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koya","family":"Hida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eiji","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsushi","family":"Itami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hajime","family":"Kubo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiharu","family":"Sakai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2010,12,24]]},"reference":[{"key":"1527_CR1","first-page":"97","volume":"46","author":"MM Ravitch","year":"1959","unstructured":"Ravitch MM, Brown IW, Daviglus GF (1959) Experimental and clinical use of the Soviet bronchus stapling instruments. Surgery 46:97\u2013108","journal-title":"Surgery"},{"key":"1527_CR2","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1378\/chest.44.6.590","volume":"44","author":"PI Androsov","year":"1963","unstructured":"Androsov PI (1963) New instruments for thoracic surgery. Dis Chest 44:590\u2013597","journal-title":"Dis Chest"},{"key":"1527_CR3","unstructured":"Manufacturer\u2019s instruction for use by Ethicon Endo-Surgery Inc., Cincinnati, OH, USA"},{"key":"1527_CR4","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1007\/s10350-008-9305-5","volume":"51","author":"J Wind","year":"2008","unstructured":"Wind J, Safiruddin F, van Berge Henegouwen MI, Slors JF, Bemelman WA (2008) Staple line failure using the Proximate 100-mm linear cutter. Dis Colon Rectum 51:1275\u20131278","journal-title":"Dis Colon Rectum"},{"key":"1527_CR5","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.jamcollsurg.2009.11.007","volume":"210","author":"AC Offodile II","year":"2010","unstructured":"Offodile AC II, Feingold DL, Nasar A, Whelan RL, Arnell TD (2010) High incidence of technical errors involving the EEA circular stapler: a single institution experience. J Am Coll Surg 210:331\u2013335","journal-title":"J Am Coll Surg"},{"key":"1527_CR6","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1007\/s00464-007-9481-8","volume":"22","author":"K Morita","year":"2008","unstructured":"Morita K, Maeda N, Kawaoka T, Hiraki S, Kudo A, Fukuda S, Oka M (2008) Effects of the time interval between clamping and linear stapling for resection of porcine small intestine. Surg Endosc 22:750\u2013756","journal-title":"Surg Endosc"},{"key":"1527_CR7","doi-asserted-by":"crossref","first-page":"1796","DOI":"10.1007\/s00464-007-9265-1","volume":"21","author":"K Kawasaki","year":"2007","unstructured":"Kawasaki K, Fujino Y, Kanemitsu K, Goto T, Kamigaki T, Kuroda D, Kuroda Y (2007) Experimental evaluation of the mechanical strength of stapling techniques. Surg Endosc 21:1796\u20131799","journal-title":"Surg Endosc"},{"key":"1527_CR8","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1007\/s00464-006-9131-6","volume":"21","author":"T Goto","year":"2007","unstructured":"Goto T, Kawasaki K, Fujino Y, Kanemitsu K, Kamigaki T, Kuroda D, Suzuki Y, Kuroda Y (2007) Evaluation of the mechanical strength and patency of functional end-to-end anastomoses. Surg Endosc 21:1508\u20131511","journal-title":"Surg Endosc"},{"key":"1527_CR9","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1159\/000096648","volume":"23","author":"LS Yo","year":"2006","unstructured":"Yo LS, Consten EC, Quarles van Ufford HM, Gooszen HG, Gagner M (2006) Buttressing of the staple line in gastrointestinal anastomoses: overview of new technology designed to reduce perioperative complications. Dig Surg 23:283\u2013291","journal-title":"Dig Surg"},{"key":"1527_CR10","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1001\/archsurg.139.1.89","volume":"139","author":"S Ahmed","year":"2004","unstructured":"Ahmed S, Hanna GB, Cuschieri A (2004) Optimal angle between instrument shaft and handle for laparoscopic bowel suturing. Arch Surg 139:89\u201392","journal-title":"Arch Surg"},{"key":"1527_CR11","first-page":"805","volume":"162","author":"AA Memon","year":"1996","unstructured":"Memon AA, Marks CG (1996) Stapled anastomoses in colorectal surgery: a prospective study. Eur J Surg 162:805\u2013810","journal-title":"Eur J Surg"},{"key":"1527_CR12","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/S0960-7404(98)00020-6","volume":"7","author":"JM Wheeler","year":"1998","unstructured":"Wheeler JM, McC Mortensen NJ (1998) Reconstructive rectal surgery. Surg Oncol 7:13\u201323","journal-title":"Surg Oncol"}],"container-title":["Surgical Endoscopy"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00464-010-1527-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00464-010-1527-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00464-010-1527-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T00:10:50Z","timestamp":1559088650000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00464-010-1527-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,12,24]]},"references-count":12,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2011,7]]}},"alternative-id":["1527"],"URL":"https:\/\/doi.org\/10.1007\/s00464-010-1527-7","relation":{},"ISSN":["0930-2794","1432-2218"],"issn-type":[{"value":"0930-2794","type":"print"},{"value":"1432-2218","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,12,24]]}}}