{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T07:46:42Z","timestamp":1789544802868,"version":"build-2803163510"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T00:00:00Z","timestamp":1770336000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T00:00:00Z","timestamp":1770336000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Surg Endosc"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1007\/s00464-026-12584-0","type":"journal-article","created":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T17:14:05Z","timestamp":1770398045000},"page":"1866-1875","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["The efficacy and safety of magnetic compression anastomosis in the management of biliary obstruction: a systematic review and meta-analysis"],"prefix":"10.1007","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-6538-0870","authenticated-orcid":false,"given":"Marwan","family":"Desouky","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-4907-3791","authenticated-orcid":false,"given":"Laith","family":"Altawil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7261-6002","authenticated-orcid":false,"given":"Mohammad","family":"Al Hayek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6406-4212","authenticated-orcid":false,"given":"Muhammed","family":"Elhadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,6]]},"reference":[{"key":"12584_CR1","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1067\/mge.2001.116876","volume":"54","author":"G Costamagna","year":"2001","unstructured":"Costamagna G, Pandolfi M, Mutignani M, Spada C, Perri V (2001) Long-term results of endoscopic management of postoperative bile duct strictures with increasing numbers of stents. Gastrointest Endosc 54:162\u2013168","journal-title":"Gastrointest Endosc"},{"key":"12584_CR2","doi-asserted-by":"publisher","first-page":"405","DOI":"10.14309\/ajg.0000000000002190","volume":"118","author":"BJ Elmunzer","year":"2023","unstructured":"Elmunzer BJ, Maranki JL, G\u00f3mez V, Tavakkoli A, Sauer BG, Limketkai BN, Brennan EA, Attridge EM, Brigham TJ, Wang AY (2023) ACG clinical guideline: diagnosis and management of biliary strictures. Am J Gastroenterol 118:405\u2013426","journal-title":"Am J Gastroenterol"},{"key":"12584_CR3","doi-asserted-by":"publisher","first-page":"4039","DOI":"10.1007\/s00268-018-4710-y","volume":"42","author":"XM Liu","year":"2018","unstructured":"Liu XM, Yan XP, Zhang HK, Ma F, Guo YG, Fan C, Wang SP, Shi AH, Wang B, Wang HH (2018) Magnetic anastomosis for biliojejunostomy: first prospective clinical trial. World J Surg 42:4039\u20134045","journal-title":"World J Surg"},{"key":"12584_CR4","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1016\/j.jss.2020.08.044","volume":"258","author":"Y Li","year":"2021","unstructured":"Li Y, Liu XM, Zhang HK, Zhang XF, Tang B, Ma F, Lv Y (2021) Magnetic compression anastomosis in laparoscopic pancreatoduodenectomy: a preliminary study. J Surg Res 258:162\u2013169","journal-title":"J Surg Res"},{"key":"12584_CR5","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-025-11634-w","author":"E \u00dcnal","year":"2025","unstructured":"\u00dcnal E, Esen \u00dc, Uysal A, Ciftci TT, Akinci D, Parlak E (2025) Combined endoscopic-percutaneous approach for magnetic compression anastomosis in post-transplant anastomotic biliary strictures. Eur Radiol. https:\/\/doi.org\/10.1007\/s00330-025-11634-w","journal-title":"Eur Radiol"},{"key":"12584_CR6","doi-asserted-by":"publisher","first-page":"2541","DOI":"10.1007\/s00464-019-07063-8","volume":"34","author":"Y Li","year":"2020","unstructured":"Li Y, Sun H, Yan XP, Wang SP, Dong DH, Liu XM, Wang B, Su MS, Lv Y (2020) Magnetic compression anastomosis for the treatment of benign biliary strictures: a clinical study from China. Surg Endosc Other Interv Tech 34:2541\u20132550","journal-title":"Surg Endosc Other Interv Tech"},{"key":"12584_CR7","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1016\/j.gie.2016.08.047","volume":"85","author":"SI Jang","year":"2017","unstructured":"Jang SI, Lee K-H, Yoon HJ, Lee DK (2017) Treatment of completely obstructed benign biliary strictures with magnetic compression anastomosis: follow-up results after recanalization. Gastrointest Endosc 85:1057\u20131066","journal-title":"Gastrointest Endosc"},{"key":"12584_CR8","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1016\/j.gie.2016.07.068","volume":"85","author":"E Parlak","year":"2017","unstructured":"Parlak E, K\u00f6ksal AS, K\u00fc\u00e7\u00fckay F, Eminler AT, Toka B, Uslan MI (2017) A novel technique for the endoscopic treatment of complete biliary anastomosis obstructions after liver transplantation: through-the-scope magnetic compression anastomosis. Gastrointest Endosc 85:841\u2013847","journal-title":"Gastrointest Endosc"},{"key":"12584_CR9","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1111\/den.12319","volume":"27","author":"SI Jang","year":"2015","unstructured":"Jang SI, Choi J, Lee DK (2015) Magnetic compression anastomosis for treatment of benign biliary stricture. Dig Endosc 27:239\u2013249","journal-title":"Dig Endosc"},{"key":"12584_CR10","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1016\/j.jvir.2009.01.019","volume":"20","author":"M Avaliani","year":"2009","unstructured":"Avaliani M, Chigogidze N, Nechipa\u01d0 A, Dolgushin B (2009) Magnetic compression biliary-enteric anastomosis for palliation of obstructive jaundice: initial clinical results. J Vasc Interv Radiol 20:614\u2013623","journal-title":"J Vasc Interv Radiol"},{"key":"12584_CR11","doi-asserted-by":"publisher","first-page":"4906","DOI":"10.1007\/s10620-022-07381-3","volume":"67","author":"B \u00d6demis","year":"2022","unstructured":"\u00d6demis B, Baspinar B, Tola M, Torun S (2022) Magnetic compression anastomosis is a good treatment option for patients with completely obstructed benign biliary strictures: a case series study. Dig Dis Sci 67:4906\u20134918","journal-title":"Dig Dis Sci"},{"key":"12584_CR12","volume":"372","author":"MJ Page","year":"2021","unstructured":"Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, Shamseer L, Tetzlaff JM, Akl EA, Brennan SE, Chou R, Glanville J, Grimshaw JM, Hr\u00f3bjartsson A, Lalu MM, Li T, Loder EW, Mayo-Wilson E, McDonald S, McGuinness LA, Stewart LA, Thomas J, Tricco AC, Welch VA, Whiting P, Moher D (2021) The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ (Clinical research ed) 372:n71","journal-title":"BMJ (Clinical research ed)"},{"key":"12584_CR13","doi-asserted-by":"publisher","first-page":"1256","DOI":"10.1111\/jgh.16574","volume":"39","author":"G Zhang","year":"2024","unstructured":"Zhang G, Liang Z, Zhao G, Zhang S (2024) Endoscopic application of magnetic compression anastomosis: a review. J Gastroenterol Hepatol 39:1256\u20131266","journal-title":"J Gastroenterol Hepatol"},{"key":"12584_CR14","doi-asserted-by":"publisher","first-page":"266","DOI":"10.5946\/ce.2020.095","volume":"53","author":"SI Jang","year":"2020","unstructured":"Jang SI, Cho JH, Lee DK (2020) Magnetic compression anastomosis for the treatment of post-transplant biliary stricture. Clin Endosc 53:266\u2013275","journal-title":"Clin Endosc"},{"key":"12584_CR15","unstructured":"National Heart, Lung, and Blood Institute (2014) Quality assessement tool for before-after studies with no control group."},{"key":"12584_CR16","unstructured":"Wells G, Shea B, O'Connell D, Peterson j, Welch V, Losos M, Tugwell P (2000) The Newcastle\u2013Ottawa Scale (NOS) for assessing the quality of non-randomized studies in meta-analysis."},{"key":"12584_CR17","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1186\/1471-2288-14-135","volume":"14","author":"X Wan","year":"2014","unstructured":"Wan X, Wang W, Liu J, Tong T (2014) Estimating the sample mean and standard deviation from the sample size, median, range and\/or interquartile range. BMC Med Res Methodol 14:135","journal-title":"BMC Med Res Methodol"},{"key":"12584_CR18","first-page":"35","volume":"17","author":"Z Fan","year":"2022","unstructured":"Fan Z, Zhao X, Ji R, Li J, Shi Y (2022) Endoscopic treatment of benign biliary stricture using different stents: a systematic review and meta-analysis Wideochirurgia i inne techniki maloinwazyjne. Videosurgery and Other Miniinvasive Tech 17:35\u201360","journal-title":"Videosurgery and Other Miniinvasive Tech"},{"key":"12584_CR19","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0260223","volume":"16","author":"B Kokas","year":"2021","unstructured":"Kokas B, Szij\u00e1rt\u00f3 A, Farkas N, Ujv\u00e1ry M, M\u00f3ri S, Kalocsai A, Sz\u00fccs \u00c1 (2021) Percutaneous transhepatic drainage is safe and effective in biliary obstruction-a single-center experience of 599 patients. PLoS ONE 16:e0260223","journal-title":"PLoS ONE"},{"key":"12584_CR20","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2023.1105728","volume":"13","author":"C Bian","year":"2023","unstructured":"Bian C, Fang Y, Xia J, Shi L, Huang H, Xiong Q, Wu R, Zeng Z (2023) Is percutaneous drainage better than endoscopic drainage in the management of patients with malignant obstructive jaundice? A meta-analysis of RCTs. Front Oncol 13:1105728","journal-title":"Front Oncol"},{"key":"12584_CR21","doi-asserted-by":"publisher","first-page":"1040","DOI":"10.1016\/j.gie.2011.06.026","volume":"74","author":"SI Jang","year":"2011","unstructured":"Jang SI, Kim JH, Won JY, Lee KH, Kim HW, You JW, Itoi T, Lee D (2011) Magnetic compression anastomosis is useful in biliary anastomotic strictures after living donor liver transplantation. Gastrointest Endosc 74:1040\u20131048","journal-title":"Gastrointest Endosc"},{"key":"12584_CR22","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.1016\/j.gie.2024.05.009","volume":"100","author":"SI Jang","year":"2024","unstructured":"Jang SI, Do MY, Lee SY, Cho JH, Joo SM, Lee KH, Chung MJ, Lee DK (2024) Magnetic compression anastomosis for the treatment of complete biliary obstruction after cholecystectomy. Gastrointest Endosc 100:1053-1060.e1054","journal-title":"Gastrointest Endosc"},{"key":"12584_CR23","doi-asserted-by":"publisher","first-page":"1933","DOI":"10.4240\/wjgs.v16.i6.1933","volume":"16","author":"MM Zhang","year":"2024","unstructured":"Zhang MM, Tao J, Sha HC, Li Y, Song XG, Muensterer OJ, Dong FF, Zhang L, Lyu Y, Yan XP (2024) Magnetic compression anastomosis to restore biliary tract continuity after obstruction following major abdominal trauma: a case report. World J Gastrointest Surg 16:1933\u20131938","journal-title":"World J Gastrointest Surg"},{"key":"12584_CR24","doi-asserted-by":"publisher","first-page":"3338","DOI":"10.1007\/s00261-021-03207-4","volume":"47","author":"AS Turan","year":"2022","unstructured":"Turan AS, Jenniskens S, Martens JM, Rutten M, Yo LSF, van Strijen MJL, Drenth JPH, Siersema PD, van Geenen EJM (2022) Complications of percutaneous transhepatic cholangiography and biliary drainage, a multicenter observational study. Abdom Radiol 47:3338\u20133344","journal-title":"Abdom Radiol"}],"container-title":["Surgical Endoscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00464-026-12584-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00464-026-12584-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00464-026-12584-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T19:35:36Z","timestamp":1773084936000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00464-026-12584-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,6]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["12584"],"URL":"https:\/\/doi.org\/10.1007\/s00464-026-12584-0","relation":{},"ISSN":["0930-2794","1432-2218"],"issn-type":[{"value":"0930-2794","type":"print"},{"value":"1432-2218","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,6]]},"assertion":[{"value":"1 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Dr. Marwan Desouky has no conflicts of interest or financial ties to disclose. Dr. Laith Altawil has no conflicts of interest or financial ties to disclose. Dr. Mohammad Al Hayek has no conflicts of interest or financial ties to disclose. Dr. Muhammed Elhadi has no conflicts of interest or financial ties to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Disclosures"}},{"value":"Artificial intelligence tools (OpenAI ChatGPT, August 2025 release) were used exclusively to refine the language, clarity, and readability of this manuscript. They played no role in the study\u2019s conception, design, data collection, statistical analysis, creation of figures or tables, interpretation of results, or generation of scientific content. The contribution was strictly limited to enhancing the presentation and style of writing. All content was thoroughly reviewed, verified, and approved by the authors to ensure accuracy and preserve scientific integrity.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"AI use declaration"}}]}}