{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T15:54:46Z","timestamp":1790956486107,"version":"4.1.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Surg Endosc"],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Previous work has examined the ergonomics of surgical procedures and the effect exoskeletons may have to support surgeons. However, hernia repair procedures are often dynamic, and current literature has yet to deduce physical demands across key segments of these procedures and examine how exoskeletons support surgeons across each of these segments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Four surgeons completed a total of 45 open and laparoscopic hernia repair procedures with and without a shoulder-support exoskeleton. Muscle activity and posture during control conditions (i.e., no exoskeleton) were used to characterize the physical demands of hernia repair procedures and were compared to the shoulder-support condition using a linear mixed effects model and t-test respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Mesh deployment was identified as the most demanding segment for open hernia repair procedures and Preparing mesh was the most demanding for laparoscopic procedures. It was found that the shoulder-support exoskeleton reduced muscle activity in the upper trapezius at the expense of increased erector spinae muscle activity and increased neck flexion. During open procedures the shoulder-support exoskeleton largely increased muscle activity across each segment during laparoscopic procedures, but reduced trunk, shoulder, and neck flexion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The most demanding segments of hernia repair procedures were identified which may be targeted in future interventions to support the physical demands experienced by surgeons. Shoulder-support exoskeletons may be more appropriate for open hernia repair procedures and potentially detrimental for laparoscopic hernia repair procedures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00464-026-13097-6","type":"journal-article","created":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T15:20:57Z","timestamp":1784647257000},"page":"8585-8601","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Physical demands of hernia repair segments and the effect of exoskeleton support"],"prefix":"10.1007","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6747-1179","authenticated-orcid":false,"given":"Alec","family":"Gonzales","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuvangee","family":"Dhar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Ball","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alfredo M.","family":"Carbonell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jackie S.","family":"Cha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,21]]},"reference":[{"key":"13097_CR1","doi-asserted-by":"publisher","DOI":"10.7717\/peerj.7824","volume":"7","author":"G Bivi\u00e1-Roig","year":"2019","unstructured":"Bivi\u00e1-Roig G, Lis\u00f3n JF, S\u00e1nchez-Zuriaga D (2019) Determining the optimal maximal and submaximal voluntary contraction tests for normalizing the erector spinae muscles. PeerJ 7:e7824. https:\/\/doi.org\/10.7717\/peerj.7824","journal-title":"PeerJ"},{"key":"13097_CR2","first-page":"4","volume":"189","author":"J Brooke","year":"1995","unstructured":"Brooke J (1995) SUS: a quick and dirty usability scale. Usability Eval Ind 189:4\u20137","journal-title":"Usability Eval Ind"},{"key":"13097_CR3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsr.2024.02.003","author":"JS Cha","year":"2024","unstructured":"Cha JS, Athanasiadis DI, Asadi H, Stefanidis D, Nussbaum MA, Yu D (2024) Evaluation of a passive arm-support exoskeleton for surgical team members: results from live surgeries. J Safety Res. https:\/\/doi.org\/10.1016\/j.jsr.2024.02.003","journal-title":"J Safety Res"},{"key":"13097_CR4","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2024.1418148","volume":"12","author":"HS Choi","year":"2024","unstructured":"Choi HS, Lee SJ, In H (2024) Development and clinical validation of passive shoulder exoskeleton with novel gravity compensation mechanism for stabilizing arm tremor of surgeons during minimally invasive surgery. Front Bioeng Biotechnol 12:1418148. https:\/\/doi.org\/10.3389\/fbioe.2024.1418148","journal-title":"Front Bioeng Biotechnol"},{"issue":"5","key":"13097_CR5","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1016\/j.jelekin.2009.10.002","volume":"20","author":"JN Chopp","year":"2010","unstructured":"Chopp JN, Fischer SL, Dickerson CR (2010) On the feasibility of obtaining multiple muscular maximal voluntary excitation levels from test exertions: a shoulder example. J Electromyogr Kinesiol 20(5):896\u2013902. https:\/\/doi.org\/10.1016\/j.jelekin.2009.10.002","journal-title":"J Electromyogr Kinesiol"},{"issue":"5","key":"13097_CR6","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1080\/00140139.2023.2240045","volume":"67","author":"A Gonzales","year":"2024","unstructured":"Gonzales A, Barbieri DF, Carbonell AM, Joseph A, Srinivasan D, Cha J (2024) The compatibility of exoskeletons in perioperative environments and workflows: an analysis of surgical team members\u2019 perspectives and workflow simulation. Ergonomics 67(5):674\u2013694. https:\/\/doi.org\/10.1080\/00140139.2023.2240045","journal-title":"Ergonomics"},{"key":"13097_CR7","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.jelekin.2017.07.001","volume":"37","author":"JA Jackson","year":"2017","unstructured":"Jackson JA, Mathiassen SE, Callaghan JP, Dempsey PG (2017) Precision based guidelines for sub-maximal normalisation task selection for trunk extensor EMG. J Electromyogr Kinesiol 37:41\u201351. https:\/\/doi.org\/10.1016\/j.jelekin.2017.07.001","journal-title":"J Electromyogr Kinesiol"},{"key":"13097_CR8","doi-asserted-by":"publisher","DOI":"10.1097\/SLA.0000000000006723","author":"JY Kim","year":"2025","unstructured":"Kim JY, Norasi H, Cassivi SD, Black DM, Hallbeck MS (2025) Use of an intraoperative head, neck, and back support exoskeleton on surgeons\u2019 pain and posture. Ann Surg. https:\/\/doi.org\/10.1097\/SLA.0000000000006723","journal-title":"Ann Surg"},{"key":"13097_CR9","doi-asserted-by":"publisher","DOI":"10.1097\/SLA.0000000000006617","author":"LC LaMonica","year":"2024","unstructured":"LaMonica LC, Farha MW, Mullen CR, Hughes TM, Kozlow JH, Chrouser KL (2024) Musculoskeletal disorders among surgeons and attitudes towards wearable devices for ergonomic optimization. Ann Surg. https:\/\/doi.org\/10.1097\/SLA.0000000000006617","journal-title":"Ann Surg"},{"issue":"1","key":"13097_CR10","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1007\/s00464-017-5667-x","volume":"32","author":"S Liu","year":"2018","unstructured":"Liu S, Hemming D, Luo RB, Reynolds J, Delong JC, Sandler BJ, Jacobsen GR, Horgan S (2018) Solving the surgeon ergonomic crisis with surgical exosuit. Surg Endosc 32(1):236\u2013244. https:\/\/doi.org\/10.1007\/s00464-017-5667-x","journal-title":"Surg Endosc"},{"issue":"11","key":"13097_CR11","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2020-038952","volume":"10","author":"T Luger","year":"2020","unstructured":"Luger T, Rieger MA, Bonsch R, Kr\u00e4mer B, Seibt R, Steinhilber B (2020) Active and passive work breaks during simulated laparoscopy among laparoscopic surgeons: study protocol for a controlled, randomised cross-over laboratory trial. BMJ Open 10(11):e038952. https:\/\/doi.org\/10.1136\/bmjopen-2020-038952","journal-title":"BMJ Open"},{"issue":"1","key":"13097_CR12","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1007\/s00423-024-03241-y","volume":"409","author":"MR Martins","year":"2024","unstructured":"Martins MR, Santos-Sousa H, do Vale MA, Bou\u00e7a-Machado R, Barbosa E, Sousa-Pinto B (2024) Comparison between the open and the laparoscopic approach in the primary ventral hernia repair: a systematic review and meta-analysis. Langenbecks Arch Surg 409(1):52. https:\/\/doi.org\/10.1007\/s00423-024-03241-y","journal-title":"Langenbecks Arch Surg"},{"issue":"4","key":"13097_CR13","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/1050-6411(94)00014-x","volume":"5","author":"SE Mathiassen","year":"1995","unstructured":"Mathiassen SE, Winkel J, H\u00e4gg GM (1995) Normalization of surface EMG amplitude from the upper trapezius muscle in ergonomic studies\u2014A review. J Electromyogr Kinesiol 5(4):197\u2013226. https:\/\/doi.org\/10.1016\/1050-6411(94)00014-x","journal-title":"J Electromyogr Kinesiol: Off J Int Soc Electrophysiol Kinesiol"},{"issue":"2","key":"13097_CR14","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/0003-6870(93)90080-S","volume":"24","author":"L McAtamney","year":"1993","unstructured":"McAtamney L, Nigel Corlett E (1993) RULA: a survey method for the investigation of work-related upper limb disorders. Appl Ergon 24(2):91\u201399. https:\/\/doi.org\/10.1016\/0003-6870(93)90080-S","journal-title":"Appl Ergon"},{"issue":"1","key":"13097_CR15","doi-asserted-by":"publisher","DOI":"10.1093\/joccuh\/uiae020","volume":"66","author":"E Nutz","year":"2024","unstructured":"Nutz E, Jarvers J-S, Theopold J, Kleber C, Osterhoff G (2024) Effect of an upper body exoskeleton for surgeons on postoperative neck, back, and shoulder complaints. J Occup Health 66(1):uiae020. https:\/\/doi.org\/10.1093\/joccuh\/uiae020","journal-title":"J Occup Health"},{"issue":"5","key":"13097_CR16","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1001\/jamasurg.2020.0034","volume":"155","author":"AS Prabhu","year":"2020","unstructured":"Prabhu AS, Carbonell A, Hope W, Warren J, Higgins R, Jacob B, Blatnik J, Haskins I, Alkhatib H, Tastaldi L, Fafaj A, Tu C, Rosen MJ (2020) Robotic Inguinal vs transabdominal laparoscopic inguinal hernia repair: the RIVAL randomized clinical trial. JAMA Surg 155(5):380\u2013387. https:\/\/doi.org\/10.1001\/jamasurg.2020.0034","journal-title":"JAMA Surg"},{"issue":"11","key":"13097_CR17","doi-asserted-by":"publisher","first-page":"1453","DOI":"10.1080\/00140139.2024.2338268","volume":"67","author":"RN Raghuraman","year":"2024","unstructured":"Raghuraman RN, Barbieri DF, Aviles J, Srinivasan D (2024) Age and gender differences in the perception and use of soft vs. rigid exoskeletons for manual material handling. Ergonomics 67(11):1453\u20131470. https:\/\/doi.org\/10.1080\/00140139.2024.2338268","journal-title":"Ergonomics"},{"issue":"1","key":"13097_CR18","doi-asserted-by":"publisher","first-page":"e19","DOI":"10.1016\/j.jss.2011.08.004","volume":"172","author":"GPY Szeto","year":"2012","unstructured":"Szeto GPY, Cheng SWK, Poon JTC, Ting ACW, Tsang RCC, Ho P (2012) Surgeons\u2019 static posture and movement repetitions in open and laparoscopic surgery. J Surg Res 172(1):e19\u2013e31. https:\/\/doi.org\/10.1016\/j.jss.2011.08.004","journal-title":"J Surg Res"},{"issue":"7","key":"13097_CR19","doi-asserted-by":"publisher","first-page":"1712","DOI":"10.1007\/s00464-009-0834-3","volume":"24","author":"GPY Szeto","year":"2010","unstructured":"Szeto GPY, Ho P, Ting ACW, Poon JTC, Tsang RCC, Cheng SWK (2010) A study of surgeons\u2019 postural muscle activity during open, laparoscopic, and endovascular surgery. Surg Endosc 24(7):1712\u20131721. https:\/\/doi.org\/10.1007\/s00464-009-0834-3","journal-title":"Surg Endosc"},{"key":"13097_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.apergo.2021.103646","volume":"100","author":"E Tetteh","year":"2022","unstructured":"Tetteh E, Hallbeck MS, Mirka GA (2022) Effects of passive exoskeleton support on EMG measures of the neck, shoulder and trunk muscles while holding simulated surgical postures and performing a simulated surgical procedure. Appl Ergon 100:103646. https:\/\/doi.org\/10.1016\/j.apergo.2021.103646","journal-title":"Appl Ergon"},{"issue":"6","key":"13097_CR21","doi-asserted-by":"publisher","first-page":"2355","DOI":"10.1007\/s10029-024-03168-9","volume":"28","author":"KR Tieken","year":"2024","unstructured":"Tieken KR, Siu K-C, Ma J, Murante A, Tanner TN, Kothari VM, Haskins IN (2024) Ergonomic differences in mesh placement and mesh fixation between laparoscopic and robotic inguinal hernia repair with mesh. Hernia 28(6):2355\u20132365. https:\/\/doi.org\/10.1007\/s10029-024-03168-9","journal-title":"Hernia"},{"key":"13097_CR22","unstructured":"Xsens Technologies B.V. (2021) MVN user manual"},{"issue":"11","key":"13097_CR23","doi-asserted-by":"publisher","first-page":"6335","DOI":"10.1007\/s00464-020-08085-3","volume":"35","author":"L Yang","year":"2021","unstructured":"Yang L, Wang T, Weidner TK, Madura JA, Morrow MM, Hallbeck MS (2021) Intraoperative musculoskeletal discomfort and risk for surgeons during open and laparoscopic surgery. Surg Endosc 35(11):6335\u20136343. https:\/\/doi.org\/10.1007\/s00464-020-08085-3","journal-title":"Surg Endosc"}],"container-title":["Surgical Endoscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00464-026-13097-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00464-026-13097-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00464-026-13097-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T15:13:06Z","timestamp":1790953986000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00464-026-13097-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,21]]},"references-count":23,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["13097"],"URL":"https:\/\/doi.org\/10.1007\/s00464-026-13097-6","relation":{},"ISSN":["0930-2794","1432-2218"],"issn-type":[{"value":"0930-2794","type":"print"},{"value":"1432-2218","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,21]]},"assertion":[{"value":"20 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Jackie Cha, Alfredo Carbonell, Alec Gonzales, Matthew Ball, and Shuvangee Dhar have no conflicts of interest or financial ties to disclose.","order":1,"name":"Ethics","label":"Disclosures","group":{"name":"EthicsHeading","label":"Declarations"}}]}}