{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T23:52:32Z","timestamp":1781740352028,"version":"3.54.5"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2013,3,11]],"date-time":"2013-03-11T00:00:00Z","timestamp":1362960000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Anesth"],"published-print":{"date-parts":[[2013,10]]},"DOI":"10.1007\/s00540-013-1588-6","type":"journal-article","created":{"date-parts":[[2013,3,10]],"date-time":"2013-03-10T06:55:41Z","timestamp":1362898541000},"page":"663-670","source":"Crossref","is-referenced-by-count":32,"title":["Clinical evaluation of C-MAC videolaryngoscope with or without use of stylet for endotracheal intubation in patients with cervical spine immobilization"],"prefix":"10.1007","volume":"27","author":[{"given":"Nidhi","family":"Gupta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Girija Prasad","family":"Rath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hemanshu","family":"Prabhakar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2013,3,11]]},"reference":[{"key":"1588_CR1","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1093\/bja\/84.6.705","volume":"84","author":"AD McLeod","year":"2000","unstructured":"McLeod AD, Calder I. Spinal cord injury and direct laryngoscopy\u2014the legend lives on. Br J Anaesth. 2000;84:705\u20139.","journal-title":"Br J Anaesth"},{"key":"1588_CR2","doi-asserted-by":"crossref","first-page":"1274","DOI":"10.1213\/00000539-200011000-00041","volume":"91","author":"J Brimacombe","year":"2000","unstructured":"Brimacombe J, Keller C, K\u00fcnzel KH, Gaber O, Boehler M, P\u00fchringer F. Cervical spine motion during airway management: a cinefluoroscopic study of the posteriorly destabilized third cervical vertebrae in human cadavers. Anesth Analg. 2000;91:1274\u20138.","journal-title":"Anesth Analg"},{"key":"1588_CR3","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1097\/00000542-200606000-00026","volume":"104","author":"ET Crosby","year":"2006","unstructured":"Crosby ET. Airway management in adults after cervical spine trauma. Anesthesiology. 2006;104:1293\u2013318.","journal-title":"Anesthesiology"},{"key":"1588_CR4","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1111\/j.1365-2044.1994.tb04254.x","volume":"49","author":"KJ Heath","year":"1994","unstructured":"Heath KJ. The effect on laryngoscopy of different cervical spine immobilization techniques. Anaesthesia. 1994;49:843\u20135.","journal-title":"Anaesthesia"},{"key":"1588_CR5","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1007\/s12630-009-9089-7","volume":"56","author":"F Thiboutot","year":"2009","unstructured":"Thiboutot F, Nicole PC, Tr\u00e9panier CA, Turgeon AF, Lessard MR. Effect of manual in-line stabilization of the cervical spine in adults on the rate of difficult orotracheal intubation by direct laryngoscopy: a randomized controlled trial. Can J Anaesth. 2009;56:412\u20138.","journal-title":"Can J Anaesth"},{"key":"1588_CR6","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1097\/ALN.0b013e318246e866","volume":"116","author":"T Asai","year":"2012","unstructured":"Asai T. Videolaryngoscopes: do they truly have roles in difficult airways? Anesthesiology. 2012;116:515\u20137.","journal-title":"Anesthesiology"},{"key":"1588_CR7","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/01.anes.0000267529.71756.f0","volume":"107","author":"CH Maharaj","year":"2007","unstructured":"Maharaj CH, Buckley E, Harte BH, Laffey JG. Endotracheal intubation in patients with cervical spine immobilization: a comparison of Macintosh and Airtraq\u2122 laryngoscopes. Anesthesiology. 2007;107:53\u20139.","journal-title":"Anesthesiology"},{"key":"1588_CR8","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1093\/bja\/aen002","volume":"100","author":"Y Enomoto","year":"2008","unstructured":"Enomoto Y, Asai T, Arai T, Kamishima K, Okuda Y. Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study. Br J Anaesth. 2008;100:544\u20138.","journal-title":"Br J Anaesth"},{"key":"1588_CR9","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1093\/bja\/aen231","volume":"101","author":"MA Malik","year":"2008","unstructured":"Malik MA, Maharaj CH, Harte BH, Laffey JG. Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization. Br J Anaesth. 2008;101:723\u201330.","journal-title":"Br J Anaesth"},{"key":"1588_CR10","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1093\/bja\/aep056","volume":"102","author":"MA Malik","year":"2009","unstructured":"Malik MA, Subramaniam R, Churasia S, Maharaj CH, Harte BH, Laffey JG. Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope, LMA CTrach, and the Macintosh laryngoscopes. Br J Anaesth. 2009;102:654\u201361.","journal-title":"Br J Anaesth"},{"key":"1588_CR11","first-page":"577","volume":"76","author":"C Byhahn","year":"2010","unstructured":"Byhahn C, Iber T, Zacharowski K, Weber CF, Ruesseler M, Schalk R, Meininger D. Tracheal intubation using the mobile C-MAC video laryngoscope or direct laryngoscopy for patients with a simulated difficult airway. Minerva Anestesiol. 2010;76:577\u201383.","journal-title":"Minerva Anestesiol"},{"key":"1588_CR12","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1111\/j.1365-2044.2010.06307.x","volume":"65","author":"J McElwain","year":"2010","unstructured":"McElwain J, Malik MA, Harte BH, Flynn NM, Laffey JG. Comparison of the C-MAC videolaryngoscope with the Macintosh, Glidescope, and Airtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins. Anaesthesia. 2010;65:483\u20139.","journal-title":"Anaesthesia"},{"key":"1588_CR13","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1093\/bja\/aer099","volume":"107","author":"J McElwain","year":"2011","unstructured":"McElwain J, Laffey JG. Comparison of the C-MAC\u00ae, Airtraq\u00ae, and Macintosh laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization. Br J Anaesth. 2011;107:258\u201364.","journal-title":"Br J Anaesth"},{"key":"1588_CR14","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1097\/ALN.0b013e318246ea34","volume":"116","author":"MF Aziz","year":"2012","unstructured":"Aziz MF, Dillman D, Fu R, Brambrink AM. Comparative effectiveness of the C-MAC video laryngoscope versus direct laryngoscopy in the setting of the predicted difficult airway. Anesthesiology. 2012;116:629\u201336.","journal-title":"Anesthesiology"},{"key":"1588_CR15","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1016\/j.annemergmed.2012.03.031","volume":"60","author":"JC Sakles","year":"2012","unstructured":"Sakles JC, Mosier J, Chiu S, Cosentino M, Kalin L. A comparison of the C-MAC video laryngoscope to the Macintosh direct laryngoscope for intubation in the emergency department. Ann Emerg Med. 2012;60:739\u201348.","journal-title":"Ann Emerg Med"},{"key":"1588_CR16","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1016\/j.resuscitation.2011.11.024","volume":"83","author":"WA Wetsch","year":"2012","unstructured":"Wetsch WA, Spelten O, Hellmich M, Carlitscheck M, Padosch SA, Lier H, B\u00f6ttiger BW, Hinkelbein J. Comparison of different video laryngoscopes for emergency intubation in a standardized airway manikin with immobilized cervical spine by experienced anaesthetists. A randomized, controlled crossover trial. Resuscitation. 2012;83:740\u20135.","journal-title":"Resuscitation"},{"key":"1588_CR17","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1007\/BF03026792","volume":"54","author":"TP Turkstra","year":"2007","unstructured":"Turkstra TP, Harle CC, Armstrong KP, Armstrong PM, Cherry RA, Hoogstra J, Jones PM. The GlideScope-specific rigid stylet and standard malleable stylet are equally effective for GlideScope use. Can J Anaesth. 2007;54:891\u20136.","journal-title":"Can J Anaesth"},{"key":"1588_CR18","doi-asserted-by":"crossref","first-page":"1560","DOI":"10.1213\/ANE.0b013e3181b7303a","volume":"109","author":"R Maassen","year":"2009","unstructured":"Maassen R, Lee R, Hermans B, Marcus M, van Zundert A. A comparison of three videolaryngoscopes: the Macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients. Anesth Analg. 2009;109:1560\u20135.","journal-title":"Anesth Analg"},{"key":"1588_CR19","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1111\/j.1365-2044.1996.tb14961.x","volume":"51","author":"PS Gataure","year":"1996","unstructured":"Gataure PS, Vaughan RS, Latto IP. Simulated difficult intubation. Comparison of the gum elastic bougie and the stylet. Anaesthesia. 1996;51:935\u20138.","journal-title":"Anaesthesia"},{"key":"1588_CR20","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1007\/BF03011357","volume":"32","author":"SR Mallampati","year":"1985","unstructured":"Mallampati SR, Gatt SP, Gugino LD, Desai SP, Waraksa B, Freiberger D, Liu PL. A clinical sign to predict difficult tracheal intubation: a prospective study. Can Anaesth Soc J. 1985;32:429\u201334.","journal-title":"Can Anaesth Soc J"},{"key":"1588_CR21","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1111\/j.1365-2044.1987.tb04039.x","volume":"42","author":"GL Samsoon","year":"1987","unstructured":"Samsoon GL, Young JR. Difficult tracheal intubation: a retrospective study. Anaesthesia. 1987;42:487\u201390.","journal-title":"Anaesthesia"},{"key":"1588_CR22","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1097\/00000542-199712000-00005","volume":"87","author":"F Adnet","year":"1997","unstructured":"Adnet F, Borron SW, Racine SX, Clemessy JL, Fournier JL, Plaisance P, Lapandry C. The Intubation Difficulty Scale (IDS): proposal and evaluation of a new score characterizing the complexity of endotracheal intubation. Anesthesiology. 1997;87:1290\u20137.","journal-title":"Anesthesiology"},{"key":"1588_CR23","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1111\/j.1365-2044.1984.tb08932.x","volume":"39","author":"RS Cormack","year":"1984","unstructured":"Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia. 1984;39:1105\u201311.","journal-title":"Anaesthesia"},{"key":"1588_CR24","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1213\/01.ANE.0000122825.04923.15","volume":"99","author":"TC Mort","year":"2004","unstructured":"Mort TC. Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts. Anesth Analg. 2004;99:607\u201313.","journal-title":"Anesth Analg"},{"key":"1588_CR25","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.bpa.2011.02.007","volume":"25","author":"J Metzner","year":"2011","unstructured":"Metzner J, Posner KL, Lam MS, Domino KB. Closed claims\u2019 analysis. Best Pract Res Clin Anaesthesiol. 2011;25:263\u201376.","journal-title":"Best Pract Res Clin Anaesthesiol"},{"key":"1588_CR26","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.annemergmed.2010.05.035","volume":"57","author":"RM Levitan","year":"2011","unstructured":"Levitan RM, Heitz JW, Sweeney M, Cooper RM. The complexities of tracheal intubation with direct laryngoscopy and alternative intubation devices. Ann Emerg Med. 2011;57:240\u20137.","journal-title":"Ann Emerg Med"},{"key":"1588_CR27","first-page":"857","volume":"20","author":"MM Magboul","year":"2010","unstructured":"Magboul MM, Joel S. The video laryngoscopes blind spots and possible lingual nerve injury by the Gliderite rigid stylet: case presentation and review of literature. Middle East J Anesthesiol. 2010;20:857\u201360.","journal-title":"Middle East J Anesthesiol"},{"key":"1588_CR28","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1111\/j.1365-2044.2010.06245.x","volume":"65","author":"J McElwain","year":"2010","unstructured":"McElwain J, Malik MA, Harte BH, Flynn NH, Laffey JG. Determination of the optimal stylet strategy for the C-MAC videolaryngoscope. Anaesthesia. 2010;65:369\u201378.","journal-title":"Anaesthesia"}],"container-title":["Journal of Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-013-1588-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00540-013-1588-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-013-1588-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T02:47:44Z","timestamp":1559098064000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00540-013-1588-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,3,11]]},"references-count":28,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2013,10]]}},"alternative-id":["1588"],"URL":"https:\/\/doi.org\/10.1007\/s00540-013-1588-6","relation":{},"ISSN":["0913-8668","1438-8359"],"issn-type":[{"value":"0913-8668","type":"print"},{"value":"1438-8359","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,3,11]]}}}