{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T20:49:33Z","timestamp":1768250973500,"version":"3.49.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,11,5]],"date-time":"2019-11-05T00:00:00Z","timestamp":1572912000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2019,11,5]],"date-time":"2019-11-05T00:00:00Z","timestamp":1572912000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"The study received a research grant from the \u201cWetenschappelijk Fonds Willy Gepts\u201d of the University Hospital, Vrije Universiteit Brussels.","award":["71091"],"award-info":[{"award-number":["71091"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Anesth"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1007\/s00540-019-02707-4","type":"journal-article","created":{"date-parts":[[2019,11,5]],"date-time":"2019-11-05T18:03:00Z","timestamp":1572976980000},"page":"144-148","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["An endotracheal tube providing \u201cpressurized sealing\u201d prevents fluid leakage in mechanically ventilated critically ill patients: a pilot study"],"prefix":"10.1007","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7724-886X","authenticated-orcid":false,"given":"Herbert","family":"Spapen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emiel","family":"Suys","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jouke","family":"De Regt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joris","family":"Troubleyn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joop","family":"Jonckheer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elisabeth","family":"De Waele","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,11,5]]},"reference":[{"key":"2707_CR1","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1186\/cc10352","volume":"15","author":"PS Zolfaghari","year":"2011","unstructured":"Zolfaghari PS, Wyncoll DLA. The tracheal tube gateway to ventilator-associated pneumonia. Crit Care. 2011;15:310.","journal-title":"Crit Care."},{"key":"2707_CR2","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1186\/1471-2334-14-119","volume":"14","author":"SI Blot","year":"2014","unstructured":"Blot SI, Poelaert J, Kollef M. How to avoid microaspiration? A key element for the prevention of ventilator-associated pneumonia in intubated ICU patients. BMC Infect Dis. 2014;14:119.","journal-title":"BMC Infect Dis."},{"key":"2707_CR3","doi-asserted-by":"publisher","first-page":"933","DOI":"10.4187\/respcare.02868","volume":"59","author":"CF Haas","year":"2014","unstructured":"Haas CF, Eakin RM, Konkle MA, Blank R. Endotracheal tubes: old and new. Respir Care. 2014;59:933\u201352.","journal-title":"Respir Care."},{"key":"2707_CR4","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1097\/EJA.0000000000000493","volume":"34","author":"HD Spapen","year":"2017","unstructured":"Spapen HD, Suys E, Diltoer M, Stiers W, Desmet G, Honor\u00e9 PM. A newly developed tracheal tube offering 'pressurised sealing' outperforms currently available tubes in preventing cuff leakage: a benchtop study. Eur J Anaesthesiol. 2017;34:411\u20136.","journal-title":"Eur J Anaesthesiol."},{"key":"2707_CR5","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1097\/ALN.0b013e31819868e0","volume":"110","author":"IA Pneumatikos","year":"2009","unstructured":"Pneumatikos IA, Dragoumanis CK, Bouros DE. Ventilator-associated pneumonia or endotracheal tube-associated pneumonia? An approach to the pathogenesis and preventive strategies emphasizing the importance of endotracheal tube. Anesthesiology. 2009;110:673\u201380.","journal-title":"Anesthesiology"},{"key":"2707_CR6","doi-asserted-by":"publisher","first-page":"1072","DOI":"10.1007\/s001340051014","volume":"25","author":"CG Adair","year":"1999","unstructured":"Adair CG, Gorman SP, Feron BM, Byers LM, Jones DS, Goldsmith CE, Moore JE, Kerr JR, Curran MD, Hogg G, Webb CH, McCarthy GJ, Milligan KR. Implications of endotracheal tube biofilm for ventilator-associated pneumonia. Intensive Care Med. 1999;25:1072\u20136.","journal-title":"Intensive Care Med."},{"key":"2707_CR7","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.4187\/respcare.05492","volume":"62","author":"A Rouz\u00e9","year":"2017","unstructured":"Rouz\u00e9 A, Jaillette E, Poissy J, Pr\u00e9au S, Nseir S. Tracheal tube design and ventilator-associated pneumonia. Respir Care. 2017;62:1316\u201323.","journal-title":"Respir Care."},{"key":"2707_CR8","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1111\/j.1756-5391.2012.01165.x","volume":"5","author":"X Li","year":"2012","unstructured":"Li X, Yuan Q, Wang L, Du L, Deng L. Silver-coated endotracheal tube versus non-coated endotracheal tube for preventing ventilator-associated pneumonia among adults: a systematic review of randomized controlled trials. J Evid Based Med. 2012;5:25\u201330.","journal-title":"J Evid Based Med."},{"key":"2707_CR9","doi-asserted-by":"crossref","unstructured":"Tokmaji G, Vermeulen H, M\u00fcller MC, Kwakman PH, Schultz MJ, Zaat SA. Silver-coated endotracheal tubes for prevention of ventilator-associated pneumonia in critically ill patients. Cochrane Database Syst Rev. 2015;8:CD009201.","DOI":"10.1002\/14651858.CD009201.pub2"},{"key":"2707_CR10","doi-asserted-by":"publisher","first-page":"1985","DOI":"10.1097\/CCM.0b013e318218a4d9","volume":"39","author":"J Muscedere","year":"2011","unstructured":"Muscedere J, Rewa O, McKechnie K, Jiang X, Laporta D, Heyland DK. Subglottic secretion drainage for the prevention of ventilator-associated pneumonia: a systematic review and meta-analysis. Crit Care Med. 2011;39:1985\u201391.","journal-title":"Crit Care Med."},{"key":"2707_CR11","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1097\/CCM.0000000000002889","volume":"46","author":"B Maertens","year":"2018","unstructured":"Maertens B, Blot K, Blot S. Prevention of ventilator-associated and early postoperative pneumonia through tapered endotracheal tube cuffs: a systematic review and meta-analysis of randomized controlled trials. Crit Care Med. 2018;46:316\u201323.","journal-title":"Crit Care Med."},{"key":"2707_CR12","doi-asserted-by":"publisher","first-page":"830","DOI":"10.1097\/CCM.0000000000001414","volume":"44","author":"DA Caroff","year":"2016","unstructured":"Caroff DA, Li L, Muscedere J, Klompas M. Subglottic secretion drainage and objective outcomes: a systematic review and meta-analysis. Crit Care Med. 2016;44:830\u201340.","journal-title":"Crit Care Med."},{"key":"2707_CR13","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1186\/s13054-016-1527-7","volume":"20","author":"Z Mao","year":"2016","unstructured":"Mao Z, Gao L, Wang G, Liu C, Zhao Y, Gu W, Kang H, Zhou F. Subglottic secretion suction for preventing ventilator-associated pneumonia: an updated meta-analysis and trial sequential analysis. Crit Care. 2016;20:353.","journal-title":"Crit Care."},{"key":"2707_CR14","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1097\/01.CCM.0000297888.82492.31","volume":"36","author":"U Lucangelo","year":"2008","unstructured":"Lucangelo U, Zin WA, Antonaglia V, Petrucci L, Viviani M, Buscema G, Borelli M, Berlot G. Effect of positive expiratory pressure and type of tracheal cuff on the incidence of aspiration in mechanically ventilated patients in an intensive care unit. Crit Care Med. 2008;36:409\u201313.","journal-title":"Crit Care Med."},{"key":"2707_CR15","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/j.iccn.2013.02.007","volume":"29","author":"E Suys","year":"2013","unstructured":"Suys E, Nieboer K, Stiers W, De Regt J, Huyghens L, Spapen H. Intermittent subglottic secretion drainage may cause tracheal damage in patients with few oropharyngeal secretions. Intensive Crit Care Nurs. 2013;29:317\u201320.","journal-title":"Intensive Crit Care Nurs."},{"key":"2707_CR16","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1007\/s00540-014-1849-z","volume":"28","author":"H Spapen","year":"2014","unstructured":"Spapen H, Moeyersons W, Stiers W, Desmet G, Suys E. Condensation of humidified air in the inflation line of a polyurethane cuff precludes correct continuous pressure monitoring during mechanical ventilation. J Anesth. 2014;28:949\u201351.","journal-title":"J Anesth."},{"issue":"5773","key":"2707_CR17","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1136\/bmj.3.5773.525","volume":"3","author":"PD Salpekar","year":"1971","unstructured":"Salpekar PD. Double-cuff endotracheal tube. Br Med J. 1971;3(5773):525.","journal-title":"Br Med J."},{"key":"2707_CR18","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1002\/lsm.1900110315","volume":"11","author":"MP Fried","year":"1991","unstructured":"Fried MP, Mallampati SR, Liu FC, Kaplan S, Caminear DS, Samonte BR. Laser resistant stainless steel endotracheal tube: experimental and clinical evaluation. Lasers Surg Med. 1991;11:301\u20136.","journal-title":"Lasers Surg Med."},{"key":"2707_CR19","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1093\/bja\/aet152","volume":"111","author":"JY Hwang","year":"2013","unstructured":"Hwang JY, Han SH, Park SH, Park SJ, Park S, Oh SH, Kim JH. Interrupting gel layer between double cuffs prevents fluid leakage past tracheal tube cuffs. Br J Anaesth. 2013;111:496\u2013504.","journal-title":"Br J Anaesth."},{"key":"2707_CR20","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1186\/s12871-018-0643-0","volume":"18","author":"HM Sohn","year":"2018","unstructured":"Sohn HM, Baik JS, Hwang JY, Kim SY, Han SH, Kim JH. Devising negative pressure within intercuff space reduces microaspiration. BMC Anesthesiol. 2018;18:181.","journal-title":"BMC Anesthesiol."},{"issue":"11","key":"2707_CR21","doi-asserted-by":"publisher","first-page":"1562","DOI":"10.1007\/s00134-017-4736-x","volume":"43","author":"Emmanuelle Jaillette","year":"2017","unstructured":"Jaillette E, Girault C, Brunin G, Zerimech F, Behal H, Chiche A, Broucqsault-Dedrie C, Fayolle C, Minacori F, Alves I, Barrailler S, Labreuche J, Robriquet L, Tamion F, Delaporte E, Thellier D, Delcourte C, Duhamel A, Nseir S, BestCuff Study Group and the BoR\u00e9al Network. Impact of tapered-cuff tracheal tube on microaspiration of gastric contents in intubated critically ill patients: a multicenter cluster-randomized cross-over controlled trial. Intensive Care Med. 2017;43:1562\u201371.","journal-title":"Intensive Care Medicine"}],"container-title":["Journal of Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-019-02707-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00540-019-02707-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-019-02707-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T22:22:22Z","timestamp":1744150942000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00540-019-02707-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,5]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["2707"],"URL":"https:\/\/doi.org\/10.1007\/s00540-019-02707-4","relation":{},"ISSN":["0913-8668","1438-8359"],"issn-type":[{"value":"0913-8668","type":"print"},{"value":"1438-8359","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,5]]},"assertion":[{"value":"16 August 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 October 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}