{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T13:59:28Z","timestamp":1753883968029,"version":"3.37.3"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2021,6,24]],"date-time":"2021-06-24T00:00:00Z","timestamp":1624492800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,6,24]],"date-time":"2021-06-24T00:00:00Z","timestamp":1624492800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Anesth"],"published-print":{"date-parts":[[2021,8]]},"DOI":"10.1007\/s00540-021-02965-1","type":"journal-article","created":{"date-parts":[[2021,6,24]],"date-time":"2021-06-24T20:02:16Z","timestamp":1624564936000},"page":"586-590","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Glucose control using an artificial pancreas in a severe COVID-19 patient on extracorporeal membrane oxygenation: a case report"],"prefix":"10.1007","volume":"35","author":[{"given":"Takuya","family":"Hinoue","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3522-6857","authenticated-orcid":false,"given":"Tomoaki","family":"Yatabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Himuro","family":"Fujiwara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Osamu","family":"Nishida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,6,24]]},"reference":[{"key":"2965_CR1","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1056\/NEJMoa2021436","volume":"384","author":"P Horby","year":"2021","unstructured":"Horby P, Lim WS, Emberson JR, Mafham M, Bell JL, Linsell L, Staplin N, Brightling C, Ustianowski A, Elamahi E, Prudon B, Green C, Felton T, Chadwick D, Rege K, Fegan C, Chappell LC, Faust SN, Jaki T, Jeffery K, Montgomery A, Rowan K, Juszczak E, Baillie K, Haynes R, Landray MJ. Dexamethasone in hospitalized patients with Covid-19. N Engl J Med. 2021;384:693\u2013704.","journal-title":"N Engl J Med"},{"key":"2965_CR2","doi-asserted-by":"publisher","first-page":"1068","DOI":"10.1016\/j.cmet.2020.04.021","volume":"31","author":"L Zhu","year":"2020","unstructured":"Zhu L, She ZG, Cheng X, Qin JJ, Zhang XJ, Cai J, Lei F, Wang H, Xie J, Wang W, Li H, Zhang P, Song X, Chen X, Xiang M, Zhang C, Bai L, Xiang D, Chen MM, Liu Y, Yan Y, Liu M, Mao W, Zou J, Liu L, Chen G, Luo P, Xiao B, Zhang C, Zhang Z, Lu Z, Wang J, Lu H, Xia X, Wang D, Liao X, Peng G, Ye P, Yang P, Yuan Y, Huang X, Guo J, Zhang BH, Li H. Association of Blood Glucose Control and Outcomes in Patients with COVID-19 and Pre-existing Type 2 Diabetes. Cell Metab. 2020;31:1068\u201377.","journal-title":"Cell Metab"},{"doi-asserted-by":"crossref","unstructured":"Sadhu AR, Serrano IA, Xu J, T Nisar T, Lucier J, Pandya AR, Patham B. Continuous glucose monitoring in critically Ill patients with COVID-19: results of an emergent pilot study. J Diabetes Sci Technol. 2020;14:1065-73","key":"2965_CR3","DOI":"10.1177\/1932296820964264"},{"key":"2965_CR4","doi-asserted-by":"publisher","first-page":"847","DOI":"10.2337\/dc20-2219","volume":"44","author":"S Agarwal","year":"2021","unstructured":"Agarwal S, Mathew J, Davis GM, Shephardson A, Levine A, Louard R, Urrutia A, Perez-Guzman C, Umpierrez CE, Peng L, Pasquel FJ. Continuous glucose monitoring in the intensive care unit during the COVID-19 pandemic. Diabetes Care. 2021;44:847\u20139.","journal-title":"Diabetes Care"},{"key":"2965_CR5","doi-asserted-by":"publisher","first-page":"1055","DOI":"10.2337\/dc20-2085","volume":"44","author":"GM Davis","year":"2021","unstructured":"Davis GM, Faulds E, Walker T, Vigliotti D, Rabinovich M, Hester J, Peng L, McLean B, Hannon P, Poindexter N, Saunders P, Perez-Guzman C, Tekwani SS, Martin GS, Umpierrez G, Agarwal S, Dungan K, Pasquel FJ. Remote continuous glucose monitoring with a computerized insulin infusion protocol for critically Ill patients in a COVID-19 medical ICU: proof of concept. Diabetes Care. 2021;44:1055\u20138.","journal-title":"Diabetes Care"},{"key":"2965_CR6","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1002\/jpen.2032","volume":"45","author":"KW Chow","year":"2021","unstructured":"Chow KW, Kelly DJ, Gupta R, Miller JD. Use of continuous glucose monitoring to assess parenteral nutrition-induced hyperglycemia in an adult patient with severe COVID-19. JPEN J Parenter Enteral Nutr. 2021;45:208\u201311.","journal-title":"JPEN J Parenter Enteral Nutr"},{"key":"2965_CR7","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1089\/dia.2020.0237","volume":"23","author":"E Ushigome","year":"2021","unstructured":"Ushigome E, Yamazaki M, Hamaguchi M, Ito T, Matsubara S, Tsuchido Y, Kasamatsu Y, Nakanishi M, Fujita N, Fukui M. Usefulness and safety of remote continuous glucose monitoring for a severe COVID-19 patient with diabetes. Diabetes Technol Ther. 2021;23:78\u201380.","journal-title":"Diabetes Technol Ther"},{"key":"2965_CR8","doi-asserted-by":"publisher","first-page":"173","DOI":"10.11648\/j.cmr.20170606.12","volume":"6","author":"LA Scrimgeour","year":"2017","unstructured":"Scrimgeour LA, Potz BA, Sellke FW, Abid MR. Continuous glucose monitoring in the cardiac ICU: current use and future directions. Clin Med Res (N Y). 2017;6:173\u20136.","journal-title":"Clin Med Res (N Y)"},{"key":"2965_CR9","doi-asserted-by":"publisher","first-page":"E67","DOI":"10.1111\/aor.12068","volume":"37","author":"Y Tsukamoto","year":"2013","unstructured":"Tsukamoto Y, Kinoshita Y, Kitagawa H, Munekage M, Munekage E, Takezaki Y, Yatabe T, Yamashita K, Yamazaki R, Okabayashi T, Tarumi M, Kobayashi M, Mishina S, Hanazaki K. Evaluation of a novel artificial pancreas: closed loop glycemic control system with continuous blood glucose monitoring. Artif Organs. 2013;37:E67-73.","journal-title":"Artif Organs"},{"unstructured":"U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health. Enforcement Policy for Non-Invasive Remote Monitoring Devices Used to Support Patient Monitoring During the Coronavirus Disease 2019 (COVID-19) Public Health Emergency (Revised) Guidance for Industry and Food and Drug Administration Staff. https:\/\/www.fda.gov\/media\/136290\/download. Accessed June 14, 2021.","key":"2965_CR10"},{"doi-asserted-by":"crossref","unstructured":"van Hooijdonk RT, Leopold JH, Winters T, Binnekade JM, Juffermans NP, Horn J, Fischer, van Dongen-Lases EC, Schultz MJ. Point accuracy and reliability of an interstitial continuous glucose-monitoring device in critically ill patients: a prospective study. Crit Care. 2015;19:34.","key":"2965_CR11","DOI":"10.1186\/s13054-015-0757-4"},{"key":"2965_CR12","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1007\/s00134-017-4683-6","volume":"43","author":"A Rhodes","year":"2017","unstructured":"Rhodes A, Evans LE, Alhazzani W, Levy MM, Antonelli M, Ferrer R, Kumar A, Sevransky JE, Sprung CL, Nunnally ME, Rochwerg B. Surviving sepsis campaign: international guidelines for management of sepsis and septic shock: 2016. Intensive Care Med. 2017;43:304\u201377.","journal-title":"Intensive Care Med"},{"key":"2965_CR13","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1186\/s40560-017-0270-8","volume":"6","author":"O Nishida","year":"2018","unstructured":"Nishida O, Ogura H, Egi M, Fujishima S, Hayashi Y, Iba T, Imaizumi H, Inoue S, Kakihana Y, Kotani J, Kushimoto S. The Japanese clinical practice guidelines for management of sepsis and septic shock 2016 (J-SSCG 2016). J Intensive Care. 2018;6:7.","journal-title":"J Intensive Care"},{"key":"2965_CR14","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1007\/s10047-015-0818-0","volume":"18","author":"K Mibu","year":"2015","unstructured":"Mibu K, Yatabe T, Yamasaki F, Kitagawa H, Munekage M, Namikawa T, Hanazaki K. Questionnaire survey on the use of a novel artificial pancreas by intensive care unit nurses. J Artif Organs. 2015;18:162\u20135.","journal-title":"J Artif Organs"},{"key":"2965_CR15","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1007\/s11748-020-01415-1","volume":"69","author":"K Aizawa","year":"2021","unstructured":"Aizawa K, Muraoka A, Kurumisawa S, Akutsu H, Sugaya A, Uesugi S, Kawahito K. Artificial endocrine pancreas with a closed-loop system effectively suppresses the accelerated hyperglycemic status after reperfusion during aortic surgery. Gen Thorac Cardiovasc Surg. 2021;69:14\u20138.","journal-title":"Gen Thorac Cardiovasc Surg"},{"unstructured":"Shin U, Naoko H, Michinori T, Yuya K, Yuka S, Yuki N, Motoharu K, Soichiro H, Mitsuo K, Yu Y, Tokito K, Satoru K, Kazuki D, Tetsuya O, Hirohisa M, Nobuhiko M, Takeshi O. Utility of bedside artificial pancreas for postoperative glycemic control in cardiac surgery. J Artif Organs. (in press)","key":"2965_CR16"},{"key":"2965_CR17","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/s10047-011-0611-7","volume":"15","author":"K Mibu","year":"2012","unstructured":"Mibu K, Yatabe T, Hanazaki K. Blood glucose control using an artificial pancreas reduces the workload of ICU nurses. J Artif Organs. 2012;15:71\u20136.","journal-title":"J Artif Organs"},{"doi-asserted-by":"crossref","unstructured":"Yatabe T, Yamazaki R, Kitagawa H, Okabayashi T, Yamashita K, Hanazaki K, Yokoyama M. The evaluation of the ability of closed-loop glycemic control device to maintain the blood glucose concentration in intensive care unit patients. Crit Care Med. 2011;39:575-8","key":"2965_CR18","DOI":"10.1097\/CCM.0b013e318206b9ad"}],"container-title":["Journal of Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-021-02965-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00540-021-02965-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-021-02965-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,24]],"date-time":"2021-07-24T04:20:26Z","timestamp":1627100426000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00540-021-02965-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,24]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,8]]}},"alternative-id":["2965"],"URL":"https:\/\/doi.org\/10.1007\/s00540-021-02965-1","relation":{},"ISSN":["0913-8668","1438-8359"],"issn-type":[{"type":"print","value":"0913-8668"},{"type":"electronic","value":"1438-8359"}],"subject":[],"published":{"date-parts":[[2021,6,24]]},"assertion":[{"value":"18 May 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 June 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}