{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T03:11:30Z","timestamp":1740107490490,"version":"3.37.3"},"reference-count":60,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2022,7,6]],"date-time":"2022-07-06T00:00:00Z","timestamp":1657065600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,7,6]],"date-time":"2022-07-06T00:00:00Z","timestamp":1657065600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Anesth"],"published-print":{"date-parts":[[2022,8]]},"DOI":"10.1007\/s00540-022-03087-y","type":"journal-article","created":{"date-parts":[[2022,7,6]],"date-time":"2022-07-06T14:02:36Z","timestamp":1657116156000},"page":"564-571","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["An unusual foreign body in the oral cavity: a case report from a patient safety point of view and literature review"],"prefix":"10.1007","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9263-737X","authenticated-orcid":false,"given":"Mariko","family":"Ito","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Natsuko","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuko","family":"Sawado","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kumiko","family":"Ishida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuki","family":"Yoshiyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Ishida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Fuseya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mikito","family":"Kawamata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,6]]},"reference":[{"key":"3087_CR1","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1177\/0310057X9902700116","volume":"27","author":"MJ Foreman","year":"1999","unstructured":"Foreman MJ, Moyes DG. Anaesthetic breathing circuit obstruction due to blockage of tracheal tube connector by a foreign body-two cases. Anaesth Intensive Care. 1999;27:73\u20135.","journal-title":"Anaesth Intensive Care"},{"key":"3087_CR2","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1111\/anae.14197","volume":"73","author":"V Athanassoglou","year":"2018","unstructured":"Athanassoglou V, Patel A, McGuire B, Higgs A, Dover MS, Brennan PA, Banerjee A, Bingham B, Pandit JJ. Systematic review of benefits or harms of routine anaesthetist-inserted throat packs in adults: practice recommendations for inserting and counting throat packs: An evidence-based consensus statement by the Difficult Airway Society (DAS), the British Association of Oral and Maxillofacial Surgery (BAOMS) and the British Association of Otorhinolaryngology, Head and Neck Surgery (ENT-UK). Anaesthesia. 2018;73:612\u20138.","journal-title":"Anaesthesia"},{"key":"3087_CR3","doi-asserted-by":"publisher","first-page":"1223","DOI":"10.1007\/s00101-009-1641-x","volume":"58","author":"L Schaffraniets","year":"2019","unstructured":"Schaffraniets L, Graz F, Tamke A. Intratracheal foreign body caused by a sheared endotracheal intubation stylet. Anaesthesist. 2019;58:1223\u20135.","journal-title":"Anaesthesist"},{"key":"3087_CR4","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1007\/s12055-012-0156-2","volume":"28","author":"YA Karamustafaoglu","year":"2012","unstructured":"Karamustafaoglu YA, Yanik F, Yoruk Y. A rare cause of cough: An unnoticed broken metallic stylet in trachea. Indian J Thorac Cardiovasc Surg. 2012;28:270\u20131.","journal-title":"Indian J Thorac Cardiovasc Surg"},{"key":"3087_CR5","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1016\/j.jemermed.2012.11.004","volume":"44","author":"V Chalhoub","year":"2013","unstructured":"Chalhoub V, Richa F, El-Rassi I, Dagher C, Yazbeck P. Pulmonary migration of a fragment of plastic coating sheared from a stylet. J Emerg Med. 2013;44:1097\u2013100.","journal-title":"J Emerg Med"},{"key":"3087_CR6","first-page":"624","volume":"22","author":"ML Sharma","year":"1994","unstructured":"Sharma ML, Bhardwaj N, Chari P. Broken metal intubating stylet. Anaesth Intensive Care. 1994;22:624.","journal-title":"Anaesth Intensive Care"},{"key":"3087_CR7","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1097\/00000542-199901000-00054","volume":"90","author":"PK Sinha","year":"1999","unstructured":"Sinha PK, Dubey PK. Shearing of plastic coating of stylet with double lumen tube: another incident. Anesthesiology. 1999;90:326.","journal-title":"Anesthesiology"},{"key":"3087_CR8","first-page":"126","volume":"10","author":"PK Sharma","year":"2010","unstructured":"Sharma PK, Khan RM, Kaul N. An unnoticed broken sheathed metallic stylet in an endotracheal tube. Sultan Qaboos Univ Med J. 2010;10:126\u20138.","journal-title":"Sultan Qaboos Univ Med J"},{"key":"3087_CR9","first-page":"927","volume":"47","author":"JG Paterson","year":"2000","unstructured":"Paterson JG. Laryngoscope breakage. Can. J Anesth. 2000;47:927.","journal-title":"J Anesth"},{"key":"3087_CR10","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1017\/S0265021508004547","volume":"25","author":"S Nithianandan","year":"2008","unstructured":"Nithianandan S, George S. Potential for foreign body going unnoticed with disposable fibreoptic laryngoscope. Eur J Anaesthesiol. 2008;25:1036\u20137.","journal-title":"Eur J Anaesthesiol"},{"key":"3087_CR11","doi-asserted-by":"publisher","first-page":"1134","DOI":"10.1177\/0310057X1003800626","volume":"38","author":"IR Cox","year":"2010","unstructured":"Cox IR. Oral foreign body from defective laryngoscope blade. Anaesth Intensive Care. 2010;38:1134\u20135.","journal-title":"Anaesth Intensive Care"},{"key":"3087_CR12","first-page":"73","volume":"86","author":"N Manohar","year":"2018","unstructured":"Manohar N, Fultambkar G, Bandishte S, Rao KS, Srinivas D. Lost and found: the story of a laryngoscope bulb. AANA J. 2018;86:73\u20134.","journal-title":"AANA J"},{"key":"3087_CR13","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1111\/j.1365-2044.2005.04523_1.x","volume":"61","author":"H Vlachtsis","year":"2006","unstructured":"Vlachtsis H, Veltman M. Shearing of a Frova intubating introducer by a Bronchocath double lumen tube. Anaesthesia. 2006;61:197\u20139.","journal-title":"Anaesthesia"},{"key":"3087_CR14","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.jclinane.2010.05.011","volume":"23","author":"HF Huang","year":"2011","unstructured":"Huang HF, Lu DV, Chen TI, Chau SW, Shieh CF. Successful difficult airway management for rare case of iatrogenic tracheal foreign body. J Clin Anesth. 2011;23:343\u20134.","journal-title":"J Clin Anesth"},{"key":"3087_CR15","doi-asserted-by":"publisher","first-page":"926","DOI":"10.1111\/j.1365-2044.2012.07242.x","volume":"67","author":"JM Huitink","year":"2012","unstructured":"Huitink JM, Bisschops M. A complication with an intubating introducer and a double-lumen tube: tip of the iceberg? Anaesthesia. 2012;67:926\u20137.","journal-title":"Anaesthesia"},{"key":"3087_CR16","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.jclinane.2015.12.044","volume":"32","author":"P Schober","year":"2016","unstructured":"Schober P, Loer SA, Schwarte LA. Airway obstruction by an unexpected equipment damage. J Clin Anesth. 2016;32:59\u201361.","journal-title":"J Clin Anesth"},{"key":"3087_CR17","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1007\/BF03016356","volume":"55","author":"YM Zhang","year":"2008","unstructured":"Zhang YM, Xue FS, Lial X. Foreign body from the lightbulb sheath of a Trachlight\u2122 in the endotracheal tube. Can J Anesth. 2008;55:789\u201390.","journal-title":"Can J Anesth"},{"key":"3087_CR18","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1097\/ALN.0b013e31817fb3f2","volume":"109","author":"K Hosokawa","year":"2008","unstructured":"Hosokawa K, Nakajima Y, Hashimoto S. Chipped rail gear of a lightwand device: A potentail complication of tracheal intubation. Anesthesiology. 2008;109:355.","journal-title":"Anesthesiology"},{"key":"3087_CR19","doi-asserted-by":"publisher","first-page":"514","DOI":"10.1097\/00000542-200308000-00045","volume":"99","author":"BA Stalter","year":"2003","unstructured":"Stalter BA, Currier DS. Endotracheal tube foreign body after intubation with a vital signs Inc, lightwand. Anesthesiology. 2003;99:514\u20135.","journal-title":"Anesthesiology"},{"key":"3087_CR20","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1111\/j.1365-2044.1979.tb04896.x","volume":"34","author":"J Pogulanik","year":"1979","unstructured":"Pogulanik J, Castro BA. A dangerous local anaesthetic spray. Anaesthesia. 1979;34:87\u20138.","journal-title":"Anaesthesia"},{"key":"3087_CR21","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1093\/bja\/68.1.115-a","volume":"68","author":"T Gin","year":"1992","unstructured":"Gin T, Lew JKL. Iatrogenic foreign body after laryngoscopy. Br J Anaesth. 1992;68:115\u20136.","journal-title":"Br J Anaesth"},{"key":"3087_CR22","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1097\/00000542-198602000-00050","volume":"64","author":"MH Zornow","year":"1986","unstructured":"Zornow MH, Mitchell MM. Foreign body aspiration during fiberoptic-assisted intubation. Anesthesiology. 1986;64:303.","journal-title":"Anesthesiology"},{"key":"3087_CR23","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1111\/j.1365-2044.1982.tb01028.x","volume":"37","author":"DDC Howat","year":"1982","unstructured":"Howat DDC. Disposable nasopharyngeal airways-a potential hazard. Anaesthesia. 1982;37:101.","journal-title":"Anaesthesia"},{"key":"3087_CR24","doi-asserted-by":"publisher","first-page":"e46","DOI":"10.1016\/j.ijsu.2007.01.004","volume":"6","author":"V Dhar","year":"2008","unstructured":"Dhar V, Al-Reefy H, Dilkes M. Case report-An iatrogenic foreign body in the airway. Int J Surg. 2008;6:e46-47.","journal-title":"Int J Surg"},{"key":"3087_CR25","first-page":"147","volume":"65","author":"SL Walton","year":"1997","unstructured":"Walton SL. Postextubation foreign body aspiration: a case report. AANA J. 1997;65:147\u20139.","journal-title":"AANA J"},{"key":"3087_CR26","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1046\/j.1365-2044.2001.01976-19.x","volume":"56","author":"EW To","year":"2001","unstructured":"To EW, Tsang WM, Yiu F, Chan M. A missing throat pack. Anaesthesia. 2001;56:383\u20134.","journal-title":"Anaesthesia"},{"key":"3087_CR27","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1111\/j.1365-2044.1989.tb11356.x","volume":"44","author":"BL Smith","year":"1989","unstructured":"Smith BL. Retained nasopharyngeal airway. Anaesthesia. 1989;44:447.","journal-title":"Anaesthesia"},{"key":"3087_CR28","doi-asserted-by":"publisher","first-page":"1596","DOI":"10.1097\/00000542-199812000-00048","volume":"89","author":"T Harioka","year":"1998","unstructured":"Harioka T, Hosoi S, Nomura K. Foreign body in the trachea originated from the inner wall of the Univent tube. Anesthesiology. 1998;89:1596.","journal-title":"Anesthesiology"},{"key":"3087_CR29","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1046\/j.1365-2044.2002.2470_12.x","volume":"57","author":"D Cameron","year":"2002","unstructured":"Cameron D, Onslow J. Obstruction of airway equipment. Anaesthesia. 2002;57:188\u20139.","journal-title":"Anaesthesia"},{"key":"3087_CR30","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1111\/j.1365-2044.2004.03920.x","volume":"59","author":"AM Chalmers","year":"2004","unstructured":"Chalmers AM, McKee L, Anderson G. Risk of airway obstruction by disk from Murphy\u2019s eye. Anaesthesia. 2004;59:924.","journal-title":"Anaesthesia"},{"key":"3087_CR31","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1213\/00000539-197605000-00036","volume":"55","author":"TM Chiu","year":"1976","unstructured":"Chiu TM, Meyers EF. Defective disposable endotracheal tube. Anesth Analg. 1976;55:437.","journal-title":"Anesth Analg"},{"key":"3087_CR32","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1046\/j.1365-2044.2002.2470_14.x","volume":"57","author":"K Srikanth","year":"2002","unstructured":"Srikanth K. Yet another foreign body in a laryngeal airway. Anaesthesia. 2002;57:189\u201390.","journal-title":"Anaesthesia"},{"key":"3087_CR33","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1111\/j.1365-2044.1978.tb08309.x","volume":"33","author":"D Wright","year":"1978","unstructured":"Wright D. Airway obstruction during anaesthesia. Anaesthesia. 1978;33:77.","journal-title":"Anaesthesia"},{"key":"3087_CR34","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1111\/j.1365-2044.1996.tb13657.x","volume":"51","author":"RH Riley","year":"1996","unstructured":"Riley RH, Browning FS. Another foreign body in a laryngeal mask airway. Anaesthesia. 1996;51:286\u20137.","journal-title":"Anaesthesia"},{"key":"3087_CR35","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1111\/j.1365-2044.1982.tb01837.x","volume":"37","author":"FW Wittmann","year":"1982","unstructured":"Wittmann FW. Airway obstruction due to a foreign body. Anaesthesia. 1982;37:865\u20136.","journal-title":"Anaesthesia"},{"key":"3087_CR36","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1111\/j.1365-2044.1991.tb09397.x","volume":"46","author":"ID Conacher","year":"1991","unstructured":"Conacher ID. Foreign body in a laryngeal mask airway. Anaesthesia. 1991;46:164.","journal-title":"Anaesthesia"},{"key":"3087_CR37","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1111\/aas.12510","volume":"59","author":"KS Olsen","year":"2015","unstructured":"Olsen KS. Aspiration of a plastic disk from the Murphy\u2019s eye of an endotracheal tube. Acta Anaesthesiol Scand. 2015;59:813\u20135.","journal-title":"Acta Anaesthesiol Scand"},{"key":"3087_CR38","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/0952-8180(93)90022-7","volume":"5","author":"BK Bevacqua","year":"1993","unstructured":"Bevacqua BK, Cleary WF. An unusual case of endotracheal tube cuff dysfunction. J Clin Anesth. 1993;5:237\u20139.","journal-title":"J Clin Anesth"},{"key":"3087_CR39","doi-asserted-by":"publisher","first-page":"1127","DOI":"10.1046\/j.1365-2044.1999.01200.x","volume":"54","author":"JM Cupitt","year":"1999","unstructured":"Cupitt JM, Roye SE. A sticky situation. Anaesthesia. 1999;54:1127\u20138.","journal-title":"Anaesthesia"},{"key":"3087_CR40","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1007\/s00540-008-0662-y","volume":"22","author":"E Haftoura","year":"2008","unstructured":"Haftoura E, Pourzitaki C, Logotheti H, Aroni F, Arambatzis P. Preoperative chewing gum and foreign body airway obstruction. J Anesth. 2008;22:479\u201380.","journal-title":"J Anesth"},{"key":"3087_CR41","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1213\/00000539-198409000-00017","volume":"63","author":"MB Ehrenpreis","year":"1984","unstructured":"Ehrenpreis MB, Oliverio RM. Endtracheal tube obstruction secondary to oral preoperative medication. Anesth Analg. 1984;63:867\u20138.","journal-title":"Anesth Analg"},{"key":"3087_CR42","doi-asserted-by":"publisher","first-page":"1535","DOI":"10.1097\/00000542-200206000-00055","volume":"96","author":"WP Bagley","year":"2002","unstructured":"Bagley WP. An unusual presentation of an airway foreign body involving dentures. Anesthesiology. 2002;96:1535.","journal-title":"Anesthesiology"},{"key":"3087_CR43","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1016\/j.jclinane.2013.01.005","volume":"25","author":"HT Lin","year":"2013","unstructured":"Lin HT, Day YJ, Sum DC, Liu FC, Liou JT. Displaced nasal silicone implant: an unusual cause of nasotracheal tube obstruction. J Clin Anesth. 2013;25:344\u20135.","journal-title":"J Clin Anesth"},{"key":"3087_CR44","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1213\/01.ANE.0000156220.26900.B8","volume":"101","author":"K Roy","year":"2005","unstructured":"Roy K, Kundra P, Ravishankar M. Unusual foreign body airway obstruction after laryngeal mask airway insertion. Anesth Analg. 2005;101:294\u20135.","journal-title":"Anesth Analg"},{"key":"3087_CR45","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1046\/j.1365-2044.2003.03005_7.x","volume":"58","author":"K Ramachandran","year":"2003","unstructured":"Ramachandran K, Chadwick S, Robson G. A \u201cforeign body\u201d in the circuit filter. Anaesthesia. 2003;58:186.","journal-title":"Anaesthesia"},{"key":"3087_CR46","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1111\/j.1365-2044.2004.04059.x","volume":"60","author":"SA Razvi","year":"2005","unstructured":"Razvi SA. A live \u201cforeign body\u201d in an anaesthetic circuit. Anaesthesia. 2005;60:102\u20133.","journal-title":"Anaesthesia"},{"key":"3087_CR47","first-page":"27","volume":"38","author":"DP Bandy","year":"1991","unstructured":"Bandy DP, Theberge DM, Richardson DD. Obstruction of naso-endotracheal tube by inferior turbinate. Anesth Prog. 1991;38:27\u20138.","journal-title":"Anesth Prog"},{"key":"3087_CR48","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1111\/j.1365-2044.1971.tb04799.x","volume":"26","author":"EA Shaw","year":"1971","unstructured":"Shaw EA. Airway obstruction. Anaesthesia. 1971;26:368\u20139.","journal-title":"Anaesthesia"},{"key":"3087_CR49","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1046\/j.1365-2044.2002.2470_13.x","volume":"57","author":"JA Lack","year":"2002","unstructured":"Lack JA. Another airway foreign body. Anaesthesia. 2002;57:189.","journal-title":"Anaesthesia"},{"key":"3087_CR50","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1007\/s00540-008-0628-0","volume":"22","author":"D Yapici","year":"2008","unstructured":"Yapici D, Atici S, Birbicer H, Oral U. Manufacturing defect in an endotracheal tube connector: risk of foreign body aspiration. J Anesth. 2008;22:333\u20134.","journal-title":"J Anesth"},{"key":"3087_CR51","first-page":"249","volume":"68","author":"Y Ogawara","year":"2014","unstructured":"Ogawara Y, Tachibana T, Orita Y, Uchidno K, Wani Y, Nagahiro I, Matsuyama Y, Abe I, Fujisawa M, Nishizakia K. Tracheal stenosis caused by unnoticed foreign bodies. Acta Med Okayama. 2014;68:249\u201352.","journal-title":"Acta Med Okayama"},{"key":"3087_CR52","doi-asserted-by":"publisher","first-page":"172","DOI":"10.4103\/mamcjms.mamcjms_44_17","volume":"3","author":"B Wadhwa","year":"2017","unstructured":"Wadhwa B, Gandotra S, Bansal V, Saxena KN. A potentially devastating unexpected complication of intubation. MAMC Med J Sci. 2017;3:172\u20133.","journal-title":"MAMC Med J Sci"},{"key":"3087_CR53","doi-asserted-by":"publisher","first-page":"111","DOI":"10.2344\/anpr-65-01-07","volume":"65","author":"M Tsukamoto","year":"2018","unstructured":"Tsukamoto M, Hirokawa J, Yokoyama T. Retained foreign body in the nasal cavity after oral maxillofacial surgery. Anesth Prog. 2018;65:111\u20132.","journal-title":"Anesth Prog"},{"key":"3087_CR54","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.jclinane.2007.02.007","volume":"19","author":"MC Newland","year":"2007","unstructured":"Newland MC, Ellis SJ, Peters KR, Simonson JA, Durham TM, Ullrich FA, Tinker JH. Dental injury associated with anesthesia; a report of 161,687 anesthetics given over 14 years. J Clin Anesth. 2007;19:339\u201345.","journal-title":"J Clin Anesth"},{"key":"3087_CR55","doi-asserted-by":"publisher","DOI":"10.1136\/bcr-2014-207145","author":"A Tammara","year":"2014","unstructured":"Tammara A, Reed RM, Verceles AC. A missing tooth after intubation. BMJ Case Rep. 2014. https:\/\/doi.org\/10.1136\/bcr-2014-207145.","journal-title":"BMJ Case Rep"},{"key":"3087_CR56","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.bjan.2013.04.009","volume":"65","author":"JM de Sousa","year":"2015","unstructured":"de Sousa JM, Mour\u00e3o JI. Tooth injury in anaesthesiology. Braz J Anesthesiol. 2015;65:511\u20138.","journal-title":"Braz J Anesthesiol"},{"key":"3087_CR57","doi-asserted-by":"publisher","first-page":"1564","DOI":"10.1213\/ane.0b013e31819d1db5","volume":"108","author":"JS Yasny","year":"2009","unstructured":"Yasny JS. Perioperative dental considerations for the anesthesiologist. Anesth Analg. 2009;108:1564\u201373.","journal-title":"Anesth Analg"},{"key":"3087_CR58","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1177\/021849230501300116","volume":"13","author":"M Er","year":"2005","unstructured":"Er M. An unusual foreign body of the esophagus. Asian Cardiovasc Thorac Ann. 2005;13:70\u20131.","journal-title":"Asian Cardiovasc Thorac Ann"},{"key":"3087_CR59","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1016\/j.annemergmed.2003.11.018","volume":"43","author":"GZ Shlamovitz","year":"2004","unstructured":"Shlamovitz GZ, Halpern P. Delayed obstruction of endotracheal tubes by aspirated foreign bodies: report of two cases. Ann Emerg Med. 2004;43:630\u20133.","journal-title":"Ann Emerg Med"},{"key":"3087_CR60","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1097\/ALN.0b013e318201c415","volume":"114","author":"LD Martin","year":"2011","unstructured":"Martin LD, Mhyre JM, Shanks AM, Tremper KK, Kheterpal S. 3,423 emergency tracheal intubations at a university hospital: airway outcomes and complications. Anesthesiology. 2011;114:42\u20138.","journal-title":"Anesthesiology"}],"container-title":["Journal of Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-022-03087-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00540-022-03087-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-022-03087-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,30]],"date-time":"2022-07-30T06:04:06Z","timestamp":1659161046000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00540-022-03087-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,6]]},"references-count":60,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,8]]}},"alternative-id":["3087"],"URL":"https:\/\/doi.org\/10.1007\/s00540-022-03087-y","relation":{},"ISSN":["0913-8668","1438-8359"],"issn-type":[{"type":"print","value":"0913-8668"},{"type":"electronic","value":"1438-8359"}],"subject":[],"published":{"date-parts":[[2022,7,6]]},"assertion":[{"value":"1 April 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable due to patient privacy concerns.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Data availability"}},{"value":"Written informed consent was obtained from the patient to publish this case report and literature review.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}