{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T03:11:33Z","timestamp":1740107493118,"version":"3.37.3"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,11,1]],"date-time":"2022-11-01T00:00:00Z","timestamp":1667260800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,11,1]],"date-time":"2022-11-01T00:00:00Z","timestamp":1667260800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Cooperation Program between Tokyo Medical and Dental University (TMDU) and Sony IP&S, Inc."}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Anesth"],"published-print":{"date-parts":[[2023,2]]},"DOI":"10.1007\/s00540-022-03131-x","type":"journal-article","created":{"date-parts":[[2022,11,1]],"date-time":"2022-11-01T03:02:46Z","timestamp":1667271766000},"page":"56-63","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Evaluation of fibrinogen concentration by clot firmness using a dielectric blood coagulation test system"],"prefix":"10.1007","volume":"37","author":[{"given":"Yulin","family":"Zeng","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yudai","family":"Yamamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshihito","family":"Hayashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9474-0020","authenticated-orcid":false,"given":"Tokujiro","family":"Uchida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,11,1]]},"reference":[{"issue":"3","key":"3131_CR1","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1111\/jth.15195","volume":"19","author":"J Bartoszko","year":"2021","unstructured":"Bartoszko J, Karkouti K. Managing the coagulopathy associated with cardiopulmonary bypass. J Thromb Haemost. 2021;19(3):617\u201332. https:\/\/doi.org\/10.1111\/jth.15195.","journal-title":"J Thromb Haemost"},{"issue":"12","key":"3131_CR2","doi-asserted-by":"publisher","first-page":"1589","DOI":"10.1111\/anae.14842","volume":"74","author":"G Erdoes","year":"2019","unstructured":"Erdoes G, Koster A, Meesters MI, Ortmann E, Bolliger D, Baryshnikova E, Ahmed A, Lance MD, Ravn HB, Ranucci M, von Heymann C, Agarwal S. The role of fibrinogen and fibrinogen concentrate in cardiac surgery: an international consensus statement from the haemostasis and transfusion scientific subcommittee of the european association of cardiothoracic anaesthesiology. Anaesthesia. 2019;74(12):1589\u2013600. https:\/\/doi.org\/10.1111\/anae.14842.","journal-title":"Anaesthesia"},{"issue":"2","key":"3131_CR3","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1097\/00000539-199508000-00026","volume":"81","author":"ST Hiippala","year":"1995","unstructured":"Hiippala ST, Myllyla GJ, Vahtera EM. Hemostatic factors and replacement of major blood loss with plasma-poor red cell concentrates. Anesth Analg. 1995;81(2):360\u20135. https:\/\/doi.org\/10.1097\/00000539-199508000-00026","journal-title":"Anesth Analg"},{"issue":"7","key":"3131_CR4","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1111\/jth.12988","volume":"13","author":"E Ortmann","year":"2015","unstructured":"Ortmann E, Rubino A, Altemimi B, Collier T, Besser MW, Klein AA. Validation of viscoelastic coagulation tests during cardiopulmonary bypass. J Thromb Haemost. 2015;13(7):1207\u201316. https:\/\/doi.org\/10.1111\/jth.12988.","journal-title":"J Thromb Haemost"},{"issue":"1","key":"3131_CR5","doi-asserted-by":"publisher","first-page":"25","DOI":"10.3233\/bir-16118","volume":"54","author":"Y Hayashi","year":"2017","unstructured":"Hayashi Y, Brun MA, Machida K, Lee S, Murata A, Omori S, Uchiyama H, Inoue Y, Kudo T, Toyofuku T, Nagasawa M, Uchimura I, Nakamura T, Muneta T. Simultaneous assessment of blood coagulation and hematocrit levels in dielectric blood coagulometry. Biorheology. 2017;54(1):25\u201335. https:\/\/doi.org\/10.3233\/bir-16118.","journal-title":"Biorheology"},{"issue":"19","key":"3131_CR6","doi-asserted-by":"publisher","first-page":"10072","DOI":"10.1021\/acs.analchem.5b02723","volume":"87","author":"Y Hayashi","year":"2015","unstructured":"Hayashi Y, Brun M-A\u00ce, Machida K, Nagasawa M. Principles of dielectric blood coagulometry as a comprehensive coagulation test. Anal Chem. 2015;87(19):10072\u20139. https:\/\/doi.org\/10.1021\/acs.analchem.5b02723.","journal-title":"Anal Chem"},{"issue":"23","key":"3131_CR7","doi-asserted-by":"publisher","first-page":"9769","DOI":"10.1021\/ac101927n","volume":"82","author":"Y Hayashi","year":"2010","unstructured":"Hayashi Y, Katsumoto Y, Omori S, Yasuda A, Asami K, Kaibara M, Uchimura I. Dielectric coagulometry: a new approach to estimate venous thrombosis risk. Anal Chem. 2010;82(23):9769\u201374. https:\/\/doi.org\/10.1021\/ac101927n.","journal-title":"Anal Chem"},{"issue":"1","key":"3131_CR8","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1053\/j.jvca.2017.06.026","volume":"32","author":"C Boer","year":"2018","unstructured":"Boer C, Meesters MI, Milojevic M, Benedetto U, Bolliger D, von Heymann C, Jeppsson A, Koster A, Osnabrugge RL, Ranucci M, Ravn HB, Vonk ABA, Wahba A, Pagano D. 2017 EACTS\/EACTA guidelines on patient blood management for adult cardiac surgery. J Cardiothorac Vasc Anesth. 2018;32(1):88\u2013120. https:\/\/doi.org\/10.1053\/j.jvca.2017.06.026.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"6","key":"3131_CR9","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1111\/bjh.13580","volume":"170","author":"BJ Hunt","year":"2015","unstructured":"Hunt BJ, Allard S, Keeling D, Norfolk D, Stanworth SJ, Pendry K. A practical guideline for the haematological management of major haemorrhage. Br J Haematol. 2015;170(6):788\u2013803. https:\/\/doi.org\/10.1111\/bjh.13580.","journal-title":"Br J Haematol"},{"issue":"7","key":"3131_CR10","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1111\/anae.13489","volume":"71","author":"AA Klein","year":"2016","unstructured":"Klein AA, Arnold P, Bingham RM, Brohi K, Clark R, Collis R, Gill R, McSporran W, Moor P, Rao Baikady R, Richards T, Shinde S, Stanworth S, Walsh TS. AAGBI guidelines: the use of blood components and their alternatives 2016. Anaesthesia. 2016;71(7):829\u201342. https:\/\/doi.org\/10.1111\/anae.13489.","journal-title":"Anaesthesia"},{"issue":"1","key":"3131_CR11","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1213\/ANE.0b013e318292efa4","volume":"117","author":"K Karkouti","year":"2013","unstructured":"Karkouti K, Callum J, Crowther MA, McCluskey SA, Pendergrast J, Tait G, Yau TM, Beattie WS. The relationship between fibrinogen levels after cardiopulmonary bypass and large volume red cell transfusion in cardiac surgery: an observational study. Anesth Analg. 2013;117(1):14\u201322. https:\/\/doi.org\/10.1213\/ANE.0b013e318292efa4.","journal-title":"Anesth Analg"},{"issue":"2","key":"3131_CR12","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.thromres.2014.05.008","volume":"134","author":"M Kindo","year":"2014","unstructured":"Kindo M, Hoang Minh T, Gerelli S, Perrier S, Meyer N, Schaeffer M, Bentz J, Announe T, Mommerot A, Collange O, Pottecher J, Cristinar M, Thiranos JC, Gros H, Mertes PM, Billaud P, Mazzucotelli JP. Plasma fibrinogen level on admission to the intensive care unit is a powerful predictor of postoperative bleeding after cardiac surgery with cardiopulmonary bypass. Thromb Res. 2014;134(2):360\u20138. https:\/\/doi.org\/10.1016\/j.thromres.2014.05.008.","journal-title":"Thromb Res"},{"key":"3131_CR13","doi-asserted-by":"publisher","unstructured":"Raicu V, Feldman Y, editors. Dielectric relaxation in biological systems: physical principles, methods, and applications. Oxford: Oxford University Press; 2015. https:\/\/doi.org\/10.1093\/acprof:oso\/9780199686513.001.0001","DOI":"10.1093\/acprof:oso\/9780199686513.001.0001"},{"issue":"5","key":"3131_CR14","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1213\/ane.0000000000002864","volume":"126","author":"P Schober","year":"2018","unstructured":"Schober P, Boer C, Schwarte LA. Correlation coefficients: appropriate use and interpretation. Anesth Analg. 2018;126(5):1763\u20138. https:\/\/doi.org\/10.1213\/ane.0000000000002864.","journal-title":"Anesth Analg"},{"key":"3131_CR15","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.thromres.2016.06.030","volume":"145","author":"Y Otaki","year":"2016","unstructured":"Otaki Y, Ebana Y, Yoshikawa S, Isobe M. Dielectric permittivity change detects the process of blood coagulation: comparative study of dielectric coagulometry with rotational thromboelastometry. Thromb Res. 2016;145:3\u201311. https:\/\/doi.org\/10.1016\/j.thromres.2016.06.030.","journal-title":"Thromb Res"},{"issue":"5","key":"3131_CR16","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1080\/17434440.2017.1308822","volume":"14","author":"T Sasano","year":"2017","unstructured":"Sasano T, Hasegawa Y, Hamada S. Novel measurements of blood coagulability for assessing the risk of thrombosis. Expert Rev Med Device. 2017;14(5):321\u20133. https:\/\/doi.org\/10.1080\/17434440.2017.1308822.","journal-title":"Expert Rev Med Device"},{"key":"3131_CR17","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1016\/j.avsg.2016.05.099","volume":"38","author":"H Uchiyama","year":"2017","unstructured":"Uchiyama H, Inoue Y, Uchimura I, Nakamura T, Kudo T, Muneta T, Kawano T. Prediction of venous thromboembolism after total knee arthroplasty using dielectric blood coagulometry. Ann Vasc Surg. 2017;38:286\u201392. https:\/\/doi.org\/10.1016\/j.avsg.2016.05.099.","journal-title":"Ann Vasc Surg"},{"issue":"1","key":"3131_CR18","doi-asserted-by":"publisher","first-page":"16129","DOI":"10.1038\/s41598-018-34229-6","volume":"8","author":"S Hamada","year":"2018","unstructured":"Hamada S, Hasegawa Y, Oono A, Suzuki A, Takahashi N, Nishimura T, Koyama T, Hagihara M, Tohda S, Furukawa T, Hirao K, Sasano T. Differential assessment of factor Xa activity and global blood coagulability utilizing novel dielectric coagulometry. Sci Rep. 2018;8(1):16129. https:\/\/doi.org\/10.1038\/s41598-018-34229-6.","journal-title":"Sci Rep"},{"issue":"1","key":"3131_CR19","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1213\/ANE.0b013e31824d523b","volume":"115","author":"S Ogawa","year":"2012","unstructured":"Ogawa S, Szlam F, Bolliger D, Nishimura T, Chen EP, Tanaka KA. The impact of hematocrit on fibrin clot formation assessed by rotational thromboelastometry. Anesth Analg. 2012;115(1):16\u201321. https:\/\/doi.org\/10.1213\/ANE.0b013e31824d523b.","journal-title":"Anesth Analg"},{"issue":"6","key":"3131_CR20","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1053\/j.jvca.2010.11.020","volume":"25","author":"R Gertler","year":"2011","unstructured":"Gertler R, Wiesner G, Tassani-Prell P, Braun SL, Martin K. Are the point-of-care diagnostics MULTIPLATE and ROTEM valid in the setting of high concentrations of heparin and its reversal with protamine? J Cardiothorac Vasc Anesth. 2011;25(6):981\u20136. https:\/\/doi.org\/10.1053\/j.jvca.2010.11.020.","journal-title":"J Cardiothorac Vasc Anesth"}],"container-title":["Journal of Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-022-03131-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00540-022-03131-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-022-03131-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,23]],"date-time":"2023-01-23T08:06:49Z","timestamp":1674461209000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00540-022-03131-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,1]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,2]]}},"alternative-id":["3131"],"URL":"https:\/\/doi.org\/10.1007\/s00540-022-03131-x","relation":{},"ISSN":["0913-8668","1438-8359"],"issn-type":[{"type":"print","value":"0913-8668"},{"type":"electronic","value":"1438-8359"}],"subject":[],"published":{"date-parts":[[2022,11,1]]},"assertion":[{"value":"19 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 October 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 November 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"TU was supported by the Cooperation Program between Tokyo Medical and Dental University (TMDU) and Sony IP&S, Inc. TU declares this study was funded by this cooperation program. YH was an employee of Sony IP&S, Inc., and now an employee of Sony Group Corporation. YH supported the technological instruction of the prototype device and contributed to the explanation of the methodology in this manuscript. YZ and YY have no conflicts of interest directly relevant to the content of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}