{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T22:35:09Z","timestamp":1793054109866,"version":"4.5.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T00:00:00Z","timestamp":1788307200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T00:00:00Z","timestamp":1788307200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Anesth"],"DOI":"10.1007\/s00540-026-03887-6","type":"journal-article","created":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T15:58:24Z","timestamp":1788364704000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The predictive performance of the Marsh model for propofol target-controlled infusion during laparoscopic surgery with liver retraction"],"prefix":"10.1007","author":[{"given":"Takuya","family":"Ogawa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8619-2864","authenticated-orcid":false,"given":"Shinju","family":"Obara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keisuke","family":"Kuwana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoki","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,2]]},"reference":[{"key":"3887_CR1","doi-asserted-by":"publisher","first-page":"1170","DOI":"10.1097\/00000542-199805000-00006","volume":"88","author":"TW Schnider","year":"1998","unstructured":"Schnider TW, Minto CF, Gambus PL, Andresen C, Goodale DB, Shafer SL, Youngs EJ. The influence of method of administration and covariates on the pharmacokinetics of propofol in adult volunteers. Anesthesiology. 1998;88:1170\u201382.","journal-title":"Anesthesiology"},{"key":"3887_CR2","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1093\/bja\/aeq195","volume":"105","author":"LI Cortinez","year":"2010","unstructured":"Cortinez LI, Anderson BJ, Penna A, Olivares L, Munoz HR, Holford NH, Struys MM, Sepulveda P. Influence of obesity on propofol pharmacokinetics: derivation of a pharmacokinetic model. Br J Anaesth. 2010;105:448\u201356.","journal-title":"Br J Anaesth"},{"key":"3887_CR3","doi-asserted-by":"publisher","first-page":"1498","DOI":"10.1097\/00000542-200206000-00033","volume":"96","author":"T Kurita","year":"2002","unstructured":"Kurita T, Morita K, Kazama T, Sato S. Influence of cardiac output on plasma propofol concentrations during constant infusion in swine. Anesthesiology. 2002;96:1498\u2013503.","journal-title":"Anesthesiology"},{"key":"3887_CR4","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1213\/00000539-199305000-00027","volume":"76","author":"JL Joris","year":"1993","unstructured":"Joris JL, Noirot DP, Legrand MJ, Jacquet NJ, Lamy ML. Hemodynamic changes during laparoscopic cholecystectomy. Anesth Analg. 1993;76:1067\u201371.","journal-title":"Anesth Analg"},{"key":"3887_CR5","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1016\/S0039-6060(97)90291-9","volume":"121","author":"T Junghans","year":"1997","unstructured":"Junghans T, B\u00f6hm B, Gr\u00fcndel K, Schwenk W, M\u00fcller JM. Does pneumoperitoneum with different gases, body positions, and intraperitoneal pressures influence renal and hepatic blood flow? Surgery. 1997;121:206\u201311.","journal-title":"Surgery"},{"key":"3887_CR6","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1213\/01.ANE.0000143566.60213.0A","volume":"100","author":"R Meierhenrich","year":"2005","unstructured":"Meierhenrich R, Gauss A, Vandenesch P, Georgieff M, Poch B, Schutz W. The effects of intraabdominally insufflated carbon dioxide on hepatic blood flow during laparoscopic surgery assessed by transesophageal echocardiography. Anesth Analg. 2005;100:340\u20137.","journal-title":"Anesth Analg."},{"key":"3887_CR7","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1007\/BF01143186","volume":"20","author":"JR Varvel","year":"1992","unstructured":"Varvel JR, Donoho DL, Shafer SL. Measuring the predictive performance of computer-controlled infusion pumps. J Pharmacokinet Biopharm. 1992;20:63\u201394.","journal-title":"J Pharmacokinet Biopharm"},{"key":"3887_CR8","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1093\/bja\/aep043","volume":"102","author":"JB Glen","year":"2009","unstructured":"Glen JB, Servin F. Evaluation of the predictive performance of four pharmacokinetic models for propofol. Br J Anaesth. 2009;102:626\u201332.","journal-title":"Br J Anaesth"},{"key":"3887_CR9","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1093\/bja\/aer198","volume":"107","author":"P Sepulveda","year":"2011","unstructured":"Sepulveda P, Cortinez LI, Saez C, Penna A, Solari S, Guerra I, Absalom AR. Performance evaluation of paediatric propofol pharmacokinetic models in healthy young children. Br J Anaesth. 2011;107:593\u2013600.","journal-title":"Br J Anaesth"},{"key":"3887_CR10","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1093\/bja\/aex007","volume":"118","author":"M Hara","year":"2017","unstructured":"Hara M, Masui K, Eleveld DJ, Struys M, Uchida O. Predictive performance of eleven pharmacokinetic models for propofol infusion in children for long-duration anaesthesia. Br J Anaesth. 2017;118:415\u201323.","journal-title":"Br J Anaesth"},{"key":"3887_CR11","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1093\/bja\/76.2.313","volume":"76","author":"TG Short","year":"1996","unstructured":"Short TG, Lim TA, Tam YH. Prospective evaluation of pharmacokinetic model-controlled infusion of propofol in adult patients. Br J Anaesth. 1996;76:313\u20135.","journal-title":"Br J Anaesth"},{"key":"3887_CR12","doi-asserted-by":"publisher","first-page":"2349","DOI":"10.1002\/(SICI)1097-0258(19971030)16:20<2349::AID-SIM667>3.0.CO;2-E","volume":"16","author":"A Cnaan","year":"1997","unstructured":"Cnaan A, Laird NM, Slasor P. Using the general linear mixed model to analyse unbalanced repeated measures and longitudinal data. Stat Med. 1997;16:2349\u201380.","journal-title":"Stat Med"},{"key":"3887_CR13","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1109\/TAC.1974.1100705","volume":"19","author":"H Akaike","year":"1974","unstructured":"Akaike H. A new look at the statistical model identification. IEEE Trans Autom Control. 1974;19:716\u201323.","journal-title":"IEEE Trans Autom Control"},{"key":"3887_CR14","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1214\/aos\/1176344136","volume":"6","author":"G Schwarz","year":"1978","unstructured":"Schwarz G. Estimating the dimension of a model. Ann Stat. 1978;6:461\u20134.","journal-title":"Ann Stat"},{"key":"3887_CR15","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1007\/s10928-013-9313-5","volume":"40","author":"E Colby","year":"2013","unstructured":"Colby E, Bair E. Cross-validation for nonlinear mixed effects models. J Pharmacokinet Pharmacodyn. 2013;40:243\u201352.","journal-title":"J Pharmacokinet Pharmacodyn"},{"key":"3887_CR16","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1007\/s00540-020-02765-z","volume":"34","author":"T Ogawa","year":"2020","unstructured":"Ogawa T, Obara S, Akino M, Hanayama C, Ishido H, Murakawa M. The predictive performance of propofol target-controlled infusion during robotic-assisted laparoscopic prostatectomy with CO(2) pneumoperitoneum in the head-down position. J Anesth. 2020;34:397\u2013403.","journal-title":"J Anesth"},{"key":"3887_CR17","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1007\/s00540-017-2358-7","volume":"31","author":"T Imaizumi","year":"2017","unstructured":"Imaizumi T, Obara S, Mogami M, Iseki Y, Hasegawa M, Murakawa M. Population pharmacokinetics of intravenous acetaminophen in Japanese patients undergoing elective surgery. J Anesth. 2017;31:380\u20138.","journal-title":"J Anesth"},{"key":"3887_CR18","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1007\/s00540-017-2424-1","volume":"32","author":"S Obara","year":"2018","unstructured":"Obara S, Imaizumi T, Hakozaki T, Hosono A, Iseki Y, Sanbe N, Murakawa M. Evaluation of pharmacokinetic models of intravenous dexmedetomidine in sedated patients under spinal anesthesia. J Anesth. 2018;32:33\u201340.","journal-title":"J Anesth"},{"key":"3887_CR19","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1186\/s12871-024-02461-5","volume":"24","author":"S Lee","year":"2024","unstructured":"Lee S, Kang D, Song E, Yoo S, Jeong S. External validation of the modified Marsh and Schnider models for medium-chain triglyceride propofol in target-controlled infusion anesthesia. BMC Anesthesiol. 2024;24:70.","journal-title":"BMC Anesthesiol"},{"key":"3887_CR20","doi-asserted-by":"publisher","first-page":"942","DOI":"10.1016\/j.bja.2018.01.018","volume":"120","author":"DJ Eleveld","year":"2018","unstructured":"Eleveld DJ, Colin P, Absalom AR, Struys M. Pharmacokinetic-pharmacodynamic model for propofol for broad application in anaesthesia and sedation. Br J Anaesth. 2018;120:942\u201359.","journal-title":"Br J Anaesth"},{"issue":"Suppl 1","key":"3887_CR21","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1111\/j.1365-2044.1998.53s115.x","volume":"53","author":"JB Glen","year":"1998","unstructured":"Glen JB. The development of \u201cDiprifusor\u201d: a TCI system for propofol. Anaesthesia. 1998;53(Suppl 1):13\u201321.","journal-title":"Anaesthesia"},{"key":"3887_CR22","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1093\/bja\/67.1.41","volume":"67","author":"B Marsh","year":"1991","unstructured":"Marsh B, White M, Morton N, Kenny GN. Pharmacokinetic model driven infusion of propofol in children. Br J Anaesth. 1991;67:41\u20138.","journal-title":"Br J Anaesth"},{"key":"3887_CR23","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1007\/BF03016523","volume":"52","author":"D Takizawa","year":"2005","unstructured":"Takizawa D, Nishikawa K, Sato E, Hiraoka H, Yamamoto K, Saito S, Horiuchi R, Goto F. A dopamine infusion decreases propofol concentration during epidural blockade under general anesthesia. Can J Anaesth. 2005;52:463\u20136.","journal-title":"Can J Anaesth"},{"key":"3887_CR24","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1007\/s00228-007-0399-9","volume":"64","author":"MY Peeters","year":"2008","unstructured":"Peeters MY, Aarts LP, Boom FA, Bras LJ, Tibboel D, Danhof M, Knibbe CA. Pilot study on the influence of liver blood flow and cardiac output on the clearance of propofol in critically ill patients. Eur J Clin Pharmacol. 2008;64:329\u201334.","journal-title":"Eur J Clin Pharmacol"},{"key":"3887_CR25","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1161\/01.CIR.43.2.205","volume":"43","author":"RE Stenson","year":"1971","unstructured":"Stenson RE, Constantino RT, Harrison DC. Interrelationships of hepatic blood flow, cardiac output, and blood levels of lidocaine in man. Circulation. 1971;43:205\u201311.","journal-title":"Circulation"},{"key":"3887_CR26","doi-asserted-by":"publisher","first-page":"2804","DOI":"10.1093\/eurheartj\/eht246","volume":"34","author":"S Moller","year":"2013","unstructured":"Moller S, Bernardi M. Interactions of the heart and the liver. Eur Heart J. 2013;34:2804\u201311.","journal-title":"Eur Heart J"},{"key":"3887_CR27","doi-asserted-by":"publisher","first-page":"1250","DOI":"10.1111\/j.1365-2044.2004.04020.x","volume":"59","author":"D Takizawa","year":"2004","unstructured":"Takizawa D, Hiraoka H, Nakamura K, Yamamoto K, Horiuchi R. Influence of the prone position on propofol pharmacokinetics. Anaesthesia. 2004;59:1250\u20131.","journal-title":"Anaesthesia"},{"key":"3887_CR28","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1007\/s00540-005-0355-8","volume":"20","author":"D Takizawa","year":"2006","unstructured":"Takizawa D, Hiraoka H, Sato E, Aso T, Aso C, Kunimoto F, Goto F. The effect of gynecologic laparoscopy on propofol concentrations administered by the target-controlled infusion system. J Anesth. 2006;20:57\u20139.","journal-title":"J Anesth"},{"key":"3887_CR29","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s42077-021-00135-9","volume":"13","author":"S Tokimura","year":"2021","unstructured":"Tokimura S, Obara S, Hosono A, Hakozaki T, Kurosawa S. Severe liver dysfunction that required transfusion therapy after laparoscopic antireflux surgery. Ain-Shams J Anesthesiol. 2021;13:12.","journal-title":"Ain-Shams J Anesthesiol"},{"key":"3887_CR30","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1089\/lap.2011.0161","volume":"21","author":"M Takemura","year":"2011","unstructured":"Takemura M, Ikebe T, Mayumi K, Nishioka T, Hori T. A novel liver retraction technique for lateral lobe of the liver during laparoscopic surgery using silicone disk. J Laparoendosc Adv Surg Tech A. 2011;21:729\u201332.","journal-title":"J Laparoendosc Adv Surg Tech A"},{"key":"3887_CR31","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1089\/lap.2018.0379","volume":"29","author":"O Hachiya","year":"2019","unstructured":"Hachiya O, Sato T, Toda M, Kimura W. An easy and safe method of liver retraction using a silicone disc and needle forceps for laparoscopic gastrectomy. J Laparoendosc Adv Surg Tech A. 2019;29:484\u20138.","journal-title":"J Laparoendosc Adv Surg Tech A"},{"key":"3887_CR32","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1136\/gut.33.1.92","volume":"33","author":"KM Carlisle","year":"1992","unstructured":"Carlisle KM, Halliwell M, Read AE, Wells PN. Estimation of total hepatic blood flow by duplex ultrasound. Gut. 1992;33:92\u20137.","journal-title":"Gut"},{"key":"3887_CR33","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1023\/A:1009948128543","volume":"14","author":"T Imai","year":"1998","unstructured":"Imai T, Takahashi K, Goto F, Morishita Y. Measurement of blood concentration of indocyanine green by pulse dye densitometry--comparison with the conventional spectrophotometric method. J Clin Monit Comput. 1998;14:477\u201384.","journal-title":"J Clin Monit Comput"},{"key":"3887_CR34","doi-asserted-by":"publisher","first-page":"1361","DOI":"10.1053\/j.jvca.2014.02.020","volume":"28","author":"K Suehiro","year":"2014","unstructured":"Suehiro K, Tanaka K, Matsuura T, Funao T, Yamada T, Mori T, Nishikawa K. The Vigileo-FloTrac\u2122 system: arterial waveform analysis for measuring cardiac output and predicting fluid responsiveness: a clinical review. J Cardiothorac Vasc Anesth. 2014;28:1361\u201374.","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"3887_CR35","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.jclinane.2016.07.036","volume":"35","author":"M Nakasuji","year":"2016","unstructured":"Nakasuji M, Okutani A, Miyata T, Imanaka N, Tanaka M, Nakasuji K, Nagai M. Disagreement between fourth-generation FloTrac and LiDCOrapid measurements of cardiac output and stroke volume variation during laparoscopic colectomy. J Clin Anesth. 2016;35:150\u20136.","journal-title":"J Clin Anesth"},{"key":"3887_CR36","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1053\/j.jvca.2014.07.022","volume":"29","author":"K Suehiro","year":"2015","unstructured":"Suehiro K, Tanaka K, Mikawa M, Uchihara Y, Matsuyama T, Matsuura T, Funao T, Yamada T, Mori T, Nishikawa K. Improved performance of the fourth-generation FloTrac\/Vigileo system for tracking cardiac output changes. J Cardiothorac Vasc Anesth. 2015;29:656\u201362.","journal-title":"J Cardiothorac Vasc Anesth"}],"updated-by":[{"DOI":"10.1007\/s00540-026-03906-6","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T00:00:00Z","timestamp":1792972800000}}],"container-title":["Journal of Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-026-03887-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00540-026-03887-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00540-026-03887-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T22:01:21Z","timestamp":1793052081000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00540-026-03887-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,2]]},"references-count":36,"alternative-id":["3887"],"URL":"https:\/\/doi.org\/10.1007\/s00540-026-03887-6","relation":{},"ISSN":["0913-8668","1438-8359"],"issn-type":[{"value":"0913-8668","type":"print"},{"value":"1438-8359","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,2]]},"assertion":[{"value":"17 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2026","order":5,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":6,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The original online version of this article was revised: figure 2 has been updated.","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 October 2026","order":8,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":9,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":10,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1007\/s00540-026-03906-6","URL":"https:\/\/doi.org\/10.1007\/s00540-026-03906-6","order":11,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Shinju Obara is Section Editor of the Journal of Anesthesia. All authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Research Ethics Committee (approval number: 2023-087) and registered in the Japan Registry of Clinical Trials (jRCT; jRCT1021230068). Written informed consent was obtained from all participants.","order":2,"name":"Ethics","label":"Ethical approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}}]}}