{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T08:16:27Z","timestamp":1791101787466,"version":"4.1.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2008,8,1]],"date-time":"2008-08-01T00:00:00Z","timestamp":1217548800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2008,8]]},"DOI":"10.1007\/s00586-008-0657-2","type":"journal-article","created":{"date-parts":[[2008,6,26]],"date-time":"2008-06-26T08:55:35Z","timestamp":1214470535000},"page":"1049-1056","source":"Crossref","is-referenced-by-count":188,"title":["Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure"],"prefix":"10.1007","volume":"17","author":[{"given":"Hans-Joachim","family":"Wilke","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Drumm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"H\u00e4ussler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Mack","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W. -I.","family":"Steudel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Kettler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2008,8,1]]},"reference":[{"issue":"11","key":"657_CR1","doi-asserted-by":"publisher","first-page":"1424","DOI":"10.1097\/00007632-200006010-00016","volume":"25","author":"T Amundsen","year":"2000","unstructured":"Amundsen T, Weber H, Nordal HJ, Magnaes B, Abdelnoor M, Lilleas F (2000) Lumbar spinal stenosis: conservative or surgical management?: A prospective 10-year study. Spine 25(11):1424\u20131435 (discussion 1435\u20131436)","journal-title":"Spine"},{"issue":"16 Suppl","key":"657_CR2","doi-asserted-by":"publisher","first-page":"S73","DOI":"10.1097\/01.brs.0000174532.58468.6c","volume":"30","author":"SD Christie","year":"2005","unstructured":"Christie SD, Song JK, Fessler RG (2005) Dynamic interspinous process technology. Spine 30(16 Suppl):S73\u2013S78","journal-title":"Spine"},{"issue":"5","key":"657_CR3","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1097\/00002517-200010000-00013","volume":"13","author":"A Fujiwara","year":"2000","unstructured":"Fujiwara A, Tamai K, An HS, Kurihashi T, Lim TH, Yoshida H, Saotome K (2000) The relationship between disc degeneration, facet joint osteoarthritis, and stability of the degenerative lumbar spine. J Spinal Disord 13(5):444\u2013500","journal-title":"J Spinal Disord"},{"issue":"5","key":"657_CR4","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1007\/s00586-005-0953-z","volume":"15","author":"T Guehring","year":"2006","unstructured":"Guehring T, Unglaub F, Lorenz H, Omlor G, Wilke HJ, Kroeber MW (2006) Intradiscal pressure measurements in normal discs, compressed discs and compressed discs treated with axial posterior disc distraction: an experimental study on the rabbit lumbar spine model. Eur Spine J 15(5):597\u2013604","journal-title":"Eur Spine J"},{"key":"657_CR5","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1117\/12.336921","volume":"3570","author":"S H\u00f6jer","year":"1999","unstructured":"H\u00f6jer S, Krantz M, Ekstr\u00f6m L, Kaigle A, Holm S (1999) A microstructure based fiberoptic pressure sensor for measurements in lumbar intervertebral discs. Proc SPIE (in revision) 3570:115\u2013122","journal-title":"Proc SPIE (in revision)"},{"issue":"12","key":"657_CR6","doi-asserted-by":"publisher","first-page":"2186","DOI":"10.1007\/s00586-007-0485-9","volume":"16","author":"A Kettler","year":"2007","unstructured":"Kettler A, Liakos L, Haegele B, and Wilke HJ (2007) Are the spines of calf, pig and sheep suitable models for pre-clinical implant tests? Eur Spine J 16(12):2186\u20132192","journal-title":"Eur Spine J"},{"issue":"19","key":"657_CR7","doi-asserted-by":"publisher","first-page":"2192","DOI":"10.1097\/01.BRS.0000084877.88192.8E","volume":"28","author":"DP Lindsey","year":"2003","unstructured":"Lindsey DP, Swanson KE, Fuchs P, Hsu KY, Zucherman JF, Yerby SA (2003) The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine. Spine 28(19):2192\u20132197","journal-title":"Spine"},{"issue":"16","key":"657_CR8","doi-asserted-by":"publisher","first-page":"1819","DOI":"10.1097\/00007632-199708150-00004","volume":"22","author":"RJ Minns","year":"1997","unstructured":"Minns RJ, Walsh WK (1997) Preliminary design and experimental studies of a novel soft implant for correcting sagittal plane instability in the lumbar spine. Spine 22(16):1819\u20131825 (discussion 1826\u20131827)","journal-title":"Spine"},{"issue":"4","key":"657_CR9","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1097\/00024720-200308000-00015","volume":"16","author":"W Schmoelz","year":"2003","unstructured":"Schmoelz W, Huber JF, Nydegger T, Dipl I, Claes L, Wilke HJ (2003) Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech 16(4):418\u2013423","journal-title":"J Spinal Disord Tech"},{"issue":"2","key":"657_CR10","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1097\/00007632-200001150-00009","volume":"25","author":"AC Simotas","year":"2000","unstructured":"Simotas AC, Dorey FJ, Hansraj KK, Cammisa F Jr (2000) Nonoperative treatment for lumbar spinal stenosis. Clinical and outcome results and a 3-year survivorship analysis. Spine 25(2):197\u2013203 (discussions 203\u2013204)","journal-title":"Spine"},{"issue":"1","key":"657_CR11","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1097\/00007632-200301010-00008","volume":"28","author":"KE Swanson","year":"2003","unstructured":"Swanson KE, Lindsey DP, Hsu KY, Zucherman JF, Yerby SA (2003) The effects of an interspinous implant on intervertebral disc pressures. Spine 28(1):26\u201332","journal-title":"Spine"},{"issue":"1","key":"657_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/00007632-199201000-00001","volume":"17","author":"JA Turner","year":"1992","unstructured":"Turner JA, Ersek M, Herron L, Deyo R (1992) Surgery for lumbar spinal stenosis. Attempted meta-analysis of the literature. Spine 17(1):1\u20138","journal-title":"Spine"},{"issue":"16","key":"657_CR13","doi-asserted-by":"publisher","first-page":"1906","DOI":"10.1097\/01.BRS.0000084662.02029.B2","volume":"28","author":"TE Whitesides Jr","year":"2003","unstructured":"Whitesides TE Jr (2003) The effect of an interspinous implant on intervertebral disc pressures. Spine 28(16):1906\u20131907 (author reply 1907\u20131908)","journal-title":"Spine"},{"issue":"2","key":"657_CR14","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1007\/s005860050045","volume":"7","author":"HJ Wilke","year":"1998","unstructured":"Wilke HJ, Wenger K, Claes L (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 7(2):148\u2013154","journal-title":"Eur Spine J"},{"issue":"8","key":"657_CR15","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1097\/00007632-199904150-00005","volume":"24","author":"HJ Wilke","year":"1999","unstructured":"Wilke HJ, Neef P, Caimi M, Hoogland T, Claes LE (1999) New in vivo measurements of pressures in the intervertebral disc in daily life. Spine 24(8):755\u2013762","journal-title":"Spine"},{"issue":"6","key":"657_CR16","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1007\/s00586-005-1029-9","volume":"15","author":"HJ Wilke","year":"2006","unstructured":"Wilke HJ, Rohlmann F, Neidlinger-Wilke C, Werner K, Claes L, Kettler A (2006) Validity and interobserver agreement of a new radiographic grading system for intervertebral disc degeneration: part I. Lumbar spine. Eur Spine J 15(6):720\u2013730","journal-title":"Eur Spine J"},{"issue":"8","key":"657_CR17","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1097\/01.brs.0000158876.51771.f8","volume":"30","author":"CM Wiseman","year":"2005","unstructured":"Wiseman CM, Lindsey DP, Fredrick AD, Yerby SA (2005) The effect of an interspinous process implant on facet loading during extension. Spine 30(8):903\u2013907","journal-title":"Spine"},{"key":"657_CR18","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1097\/00003086-198602000-00012","volume":"203","author":"MR Zindrick","year":"1986","unstructured":"Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field BT, Spencer CW (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop 203:99\u2013112","journal-title":"Clin Orthop"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-008-0657-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00586-008-0657-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-008-0657-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-008-0657-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,19]],"date-time":"2023-05-19T00:04:37Z","timestamp":1684454677000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00586-008-0657-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,8]]},"references-count":18,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2008,8]]}},"alternative-id":["657"],"URL":"https:\/\/doi.org\/10.1007\/s00586-008-0657-2","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,8]]}}}