{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T07:02:06Z","timestamp":1790665326342,"version":"4.1.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2009,6,2]],"date-time":"2009-06-02T00:00:00Z","timestamp":1243900800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2009,9]]},"DOI":"10.1007\/s00586-009-1032-7","type":"journal-article","created":{"date-parts":[[2009,6,1]],"date-time":"2009-06-01T11:55:53Z","timestamp":1243857353000},"page":"1293-1299","source":"Crossref","is-referenced-by-count":158,"title":["Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope"],"prefix":"10.1007","volume":"18","author":[{"given":"Yasutsugu","family":"Yukawa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fumihiko","family":"Kato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keigo","family":"Ito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yumiko","family":"Horie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsurou","family":"Hida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroaki","family":"Nakashima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masaaki","family":"Machino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2009,6,2]]},"reference":[{"issue":"1","key":"1032_CR1","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/00002517-199407010-00003","volume":"7","author":"K Abumi","year":"1994","unstructured":"Abumi K, Itoh H, Taneichi H, Kaneda K (1994) Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7(1):19\u201328. doi: 10.1097\/00002517-199407010-00003","journal-title":"J Spinal Disord"},{"issue":"16","key":"1032_CR2","doi-asserted-by":"crossref","first-page":"1853","DOI":"10.1097\/00007632-199708150-00010","volume":"22","author":"K Abumi","year":"1997","unstructured":"Abumi K, Kaneda K (1997) Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine 22(16):1853\u20131863. doi: 10.1097\/00007632-199708150-00010","journal-title":"Spine"},{"issue":"8","key":"1032_CR3","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1097\/00007632-200004150-00011","volume":"25","author":"K Abumi","year":"2000","unstructured":"Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine 25(8):962\u2013969. doi: 10.1097\/00007632-200004150-00011","journal-title":"Spine"},{"issue":"1","key":"1032_CR4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/00007632-198201000-00001","volume":"7","author":"BL Allen Jr","year":"1982","unstructured":"Allen BL Jr, Ferguson RL, Lehmann TR, O\u2019Brien RP (1982) A mechanistic classification of closed, indirect fractures and dislocations of the lower cervical spine. Spine 7(1):1\u201327. doi: 10.1097\/00007632-198200710-00001","journal-title":"Spine"},{"issue":"19","key":"1032_CR5","doi-asserted-by":"crossref","first-page":"2160","DOI":"10.1097\/00007632-200110010-00024","volume":"26","author":"R Assaker","year":"2001","unstructured":"Assaker R, Reyns N, Vinchon M, Demondion X, Louis E (2001) Transpedicular screw placement: image-guided versus lateral-view fluoroscopy: in vitro simulation. Spine 26(19):2160\u20132164. doi: 10.1097\/00007632-200110010-00024","journal-title":"Spine"},{"issue":"6","key":"1032_CR6","doi-asserted-by":"crossref","first-page":"893","DOI":"10.3171\/jns.1989.70.6.0893","volume":"70","author":"EC Benzel","year":"1989","unstructured":"Benzel EC, Kesterson L (1989) Posterior cervical interspinous compression wiring and fusion for mid to low cervical spinal injuries. J Neurosurg 70(6):893\u2013899","journal-title":"J Neurosurg"},{"issue":"1","key":"1032_CR7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/00007632-199701010-00001","volume":"22","author":"NA Ebraheim","year":"1997","unstructured":"Ebraheim NA, Xu R, Knight T, Yeasting RA (1997) Morphometric evaluation of lower cervical pedicle and its projection. Spine 22(1):1\u20136. doi: 10.1097\/00007632-199701010-00001","journal-title":"Spine"},{"issue":"3","key":"1032_CR8","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1097\/00002517-199407030-00004","volume":"7","author":"B Jeanneret","year":"1994","unstructured":"Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7(3):222\u2013229. doi: 10.1097\/00002517-199407030-00004","journal-title":"J Spinal Disord"},{"issue":"9","key":"1032_CR9","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1097\/00007632-199705010-00009","volume":"22","author":"EL Jones","year":"1997","unstructured":"Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws: anatomic feasibility and biomechanical comparison. Spine 22(9):977\u2013982. doi: 10.1097\/00007632-199705010-00009","journal-title":"Spine"},{"issue":"5","key":"1032_CR10","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1097\/00007632-199703010-00005","volume":"22","author":"EE Karaikovic","year":"1997","unstructured":"Karaikovic EE, Daubs MD, Madsen RW, Gaines RW Jr (1997) Morphologic characteristics of human cervical pedicles. Spine 22(5):493\u2013500. doi: 10.1097\/00007632-199703010-00005","journal-title":"Spine"},{"issue":"1","key":"1032_CR11","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1097\/00002517-200002000-00013","volume":"13","author":"EE Karaikovic","year":"2000","unstructured":"Karaikovic EE, Kunakornsawat S, Daubs MD, Madsen TW, Gaines RW Jr (2000) Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization. J Spinal Disord 13(1):63\u201372. doi: 10.1097\/00002517-200002000-00013","journal-title":"J Spinal Disord"},{"issue":"22","key":"1032_CR12","doi-asserted-by":"crossref","first-page":"2529","DOI":"10.1097\/00007632-199411001-00007","volume":"19","author":"Y Kotani","year":"1994","unstructured":"Kotani Y, Cunningham BW, Abumi K, McAfee PC (1994) Biomechanical analysis of cervical stabilization systems: an assessment of transpedicular screw fixation in the cervical spine. Spine 19(22):2529\u20132539","journal-title":"Spine"},{"key":"1032_CR13","doi-asserted-by":"crossref","unstructured":"Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg Spine 99(3 Suppl):257\u2013263","DOI":"10.3171\/spi.2003.99.3.0257"},{"issue":"17","key":"1032_CR14","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1097\/01.brs.0000137287.67388.0b","volume":"29","author":"R Kothe","year":"2004","unstructured":"Kothe R, Ruther W, Schneider E, Linke B (2004) Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine. Spine 29(17):1869\u20131875. doi: 10.1097\/01.brs.0000137287.67388.0b","journal-title":"Spine"},{"key":"1032_CR15","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1097\/00003086-199902000-00009","volume":"359","author":"SC Ludwig","year":"1999","unstructured":"Ludwig SC, Kramer DL, Vaccaro AR, Albert TJ (1999) Transpedicle screw fixation of the cervical spine. Clin Orthop Relat Res 359:77\u201388. doi: 10.1097\/00003086-199902000-00009 (Review)","journal-title":"Clin Orthop Relat Res"},{"issue":"13","key":"1032_CR16","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1097\/00007632-200007010-00009","volume":"25","author":"SC Ludwig","year":"2000","unstructured":"Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ (2000) Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine 25(13):1655\u20131667. doi: 10.1097\/00007632-200007010-00009","journal-title":"Spine"},{"issue":"10","key":"1032_CR17","doi-asserted-by":"crossref","first-page":"1197","DOI":"10.1097\/00007632-200005150-00002","volume":"25","author":"MM Panjabi","year":"2000","unstructured":"Panjabi MM, Shin EK, Chen NC, Wang JL (2000) Internal morphology of human cervical pedicles. Spine 25(10):1197\u20131205. doi: 10.1097\/00007632-200005150-00002","journal-title":"Spine"},{"key":"1032_CR18","first-page":"163","volume-title":"Spinal trauma","author":"R Roy-Camille","year":"1991","unstructured":"Roy-Camille R (1991) Rationale and techniques of internal fixation in trauma of the cervical spine. In: Errico T, Bauer RD, Waugh T (eds) Spinal trauma. JB Lippincott, Philadelphia, pp 163\u2013191"},{"key":"1032_CR19","doi-asserted-by":"crossref","unstructured":"Roy-Camille R, Saillant G, Laville C, Benazet JP (1992) Treatment of lower cervical spinal injuries\u2014C3 to C7. Spine 17(10 Suppl):S442\u2013S446. doi: 10.1097\/00007632-199210001-00017","DOI":"10.1097\/00007632-199210001-00017"},{"issue":"22","key":"1032_CR20","doi-asserted-by":"crossref","first-page":"2510","DOI":"10.1097\/01.brs.0000144404.68486.85","volume":"29","author":"T Sakamoto","year":"2004","unstructured":"Sakamoto T, Neo M, Nakamura T (2004) Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle. Spine 29(22):2510\u20132514. doi: 10.1097\/01.brs.0000144404.68486.85 discussion 2515","journal-title":"Spine"},{"issue":"3","key":"1032_CR21","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1097\/00007632-199702010-00009","volume":"22","author":"ML Swank","year":"1997","unstructured":"Swank ML, Sutterlin CE 3rd, Bossons CR, Dials BE (1997) Rigid internal fixation with lateral mass plates in multilevel anterior and posterior reconstruction of the cervical spine. Spine 22(3):274\u2013282. doi: 10.1097\/00007632-199702010-00009","journal-title":"Spine"},{"issue":"6","key":"1032_CR22","doi-asserted-by":"crossref","first-page":"488","DOI":"10.3171\/spi.2006.5.6.488","volume":"5","author":"Y Yukawa","year":"2006","unstructured":"Yukawa Y, Kato F, Yoshihara H, Yanase M, Ito K (2006) Cervical pedicle screw fixation for 100 cases of unstable cervical injuries using pedicle axis views by fluoroscopy. J Neurosurg Spine 5(6):488\u2013493. doi: 10.3171\/spi.2006.5.6.488","journal-title":"J Neurosurg Spine"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-009-1032-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00586-009-1032-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-009-1032-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T03:24:09Z","timestamp":1559100249000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00586-009-1032-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,6,2]]},"references-count":22,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2009,9]]}},"alternative-id":["1032"],"URL":"https:\/\/doi.org\/10.1007\/s00586-009-1032-7","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,6,2]]}}}