{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T13:38:48Z","timestamp":1790861928210,"version":"4.1.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2009,6,6]],"date-time":"2009-06-06T00:00:00Z","timestamp":1244246400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2009,10]]},"DOI":"10.1007\/s00586-009-1052-3","type":"journal-article","created":{"date-parts":[[2009,6,6]],"date-time":"2009-06-06T00:57:30Z","timestamp":1244249850000},"page":"1478-1485","source":"Crossref","is-referenced-by-count":49,"title":["Non-fusion instrumentation of the lumbar spine with a hinged pedicle screw rod system: an in vitro experiment"],"prefix":"10.1007","volume":"18","author":[{"given":"Werner","family":"Schmoelz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"U.","family":"Onder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Martin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"von Strempel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2009,6,6]]},"reference":[{"key":"1052_CR1","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1097\/00007632-198105000-00006","volume":"6","author":"MA Adams","year":"1981","unstructured":"Adams MA, Hutton WC (1981) The relevance of torsion to the mechanical derangement of the lumbar spine. Spine 6:241\u2013248. doi: 10.1097\/00007632-198105000-00006","journal-title":"Spine"},{"key":"1052_CR2","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s10143-007-0101-9","volume":"31","author":"M Bothmann","year":"2008","unstructured":"Bothmann M, Kast E, Boldt GJ, Oberle J (2008) Dynesys fixation for lumbar spine degeneration. Neurosurg Rev 31:189\u2013196. doi: 10.1007\/s10143-007-0101-9","journal-title":"Neurosurg Rev"},{"key":"1052_CR3","doi-asserted-by":"crossref","first-page":"2551","DOI":"10.1097\/BRS.0b013e318158cdbe","volume":"32","author":"BC Cheng","year":"2007","unstructured":"Cheng BC, Gordon J, Cheng J, Welch WC (2007) Immediate biomechanical effects of lumbar posterior dynamic stabilization above a circumferential fusion. Spine 32:2551\u20132557. doi: 10.1097\/BRS.0b013e318158cdbe","journal-title":"Spine"},{"key":"1052_CR4","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1097\/00007632-200001150-00006","volume":"25","author":"PA Cripton","year":"2000","unstructured":"Cripton PA, Jain GM, Wittenberg RH, Nolte LP (2000) Load-sharing characteristics of stabilized lumbar spine segments. Spine 25:170\u2013179. doi: 10.1097\/00007632-200001150-00006","journal-title":"Spine"},{"key":"1052_CR5","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1007\/s00586-008-0588-y","volume":"17","author":"AC Disch","year":"2008","unstructured":"Disch AC, Schaser KD, Melcher I, Luzzati A, Feraboli F, Schmoelz W (2008) En bloc spondylectomy reconstructions in a biomechanical in-vitro study. Eur Spine J 17:715\u2013725. doi: 10.1007\/s00586-008-0588-y","journal-title":"Eur Spine J"},{"key":"1052_CR6","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1097\/BSD.0b013e3180577259","volume":"21","author":"AC Disch","year":"2008","unstructured":"Disch AC, Schmoelz W, Matziolis G, Schneider SV, Knop C, Putzier M (2008) Higher risk of adjacent segment degeneration after floating fusions: long-term outcome after low lumbar spine fusions. J Spinal Disord Tech 21:79\u201385. doi: 10.1097\/BSD.0b013e3180577259","journal-title":"J Spinal Disord Tech"},{"key":"1052_CR7","doi-asserted-by":"crossref","first-page":"1266","DOI":"10.1097\/01.brs.0000164152.32734.d2","volume":"30","author":"PD Fuchs","year":"2005","unstructured":"Fuchs PD, Lindsey DP, Hsu KY, Zucherman JF, Yerby SA (2005) The use of an interspinous implant in conjunction with a graded facetectomy procedure. Spine 30:1266\u20131272. doi: 10.1097\/01.brs.0000164152.32734.d2 discussion 1273\u20131274","journal-title":"Spine"},{"key":"1052_CR8","doi-asserted-by":"crossref","first-page":"3036","DOI":"10.1097\/00007632-200012010-00011","volume":"25","author":"A Fujiwara","year":"2000","unstructured":"Fujiwara A, Lim TH, An HS, Tanaka N, Jeon CH, Andersson GB, Haughton VM (2000) The effect of disc degeneration and facet joint osteoarthritis on the segmental flexibility of the lumbar spine. Spine 25:3036\u20133044. doi: 10.1097\/00007632-200012010-00011","journal-title":"Spine"},{"key":"1052_CR9","doi-asserted-by":"crossref","first-page":"1497","DOI":"10.2106\/00004623-200407000-00020","volume":"86A","author":"G Ghiselli","year":"2004","unstructured":"Ghiselli G, Wang JC, Bhatia NN, Hsu WK, Dawson EG (2004) Adjacent segment degeneration in the lumbar spine. J Bone Joint Surg Am 86A:1497\u20131503","journal-title":"J Bone Joint Surg Am"},{"issue":"Suppl 2","key":"1052_CR10","first-page":"103","volume":"88","author":"VK Goel","year":"2006","unstructured":"Goel VK, Panjabi MM, Patwardhan AG, Dooris AP, Serhan H (2006) Test protocols for evaluation of spinal implants. J Bone Joint Surg Am 88(Suppl 2):103\u2013109. doi: 10.2106\/JBJS.E.01363","journal-title":"J Bone Joint Surg Am"},{"key":"1052_CR11","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1097\/01.brs.0000152584.46266.25","volume":"30","author":"D Grob","year":"2005","unstructured":"Grob D, Benini A, Junge A, Mannion AF (2005) Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: surgical and patient-oriented outcome in 50 cases after an average of 2 years. Spine 30:324\u2013331. doi: 10.1097\/01.brs.0000152584.46266.25","journal-title":"Spine"},{"key":"1052_CR12","doi-asserted-by":"crossref","first-page":"190S","DOI":"10.1016\/j.spinee.2004.07.007","volume":"4","author":"AS Hilibrand","year":"2004","unstructured":"Hilibrand AS, Robbins M (2004) Adjacent segment degeneration and adjacent segment disease: the consequences of spinal fusion? Spine J 4:190S\u2013194S. doi: 10.1016\/j.spinee.2004.07.007","journal-title":"Spine J"},{"key":"1052_CR13","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.clinbiomech.2007.09.004","volume":"23","author":"A Kettler","year":"2008","unstructured":"Kettler A, Drumm J, Heuer F, Haeussler K, Mack C, Claes L, Wilke HJ (2008) Can a modified interspinous spacer prevent instability in axial rotation and lateral bending? A biomechanical in vitro study resulting in a new idea. Clin Biomech (Bristol, Avon) 23:242\u2013247. doi: 10.1016\/j.clinbiomech.2007.09.004","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"1052_CR14","doi-asserted-by":"crossref","first-page":"E3","DOI":"10.3171\/foc.2007.22.1.3","volume":"22","author":"P Khoueir","year":"2007","unstructured":"Khoueir P, Kim KA, Wang MY (2007) Classification of posterior dynamic stabilization devices. Neurosurg Focus 22:E3. doi: 10.3171\/foc.2007.22.1.3","journal-title":"Neurosurg Focus"},{"key":"1052_CR15","doi-asserted-by":"crossref","first-page":"101","DOI":"10.3171\/spi.2004.1.1.0101","volume":"1","author":"SM Kim","year":"2004","unstructured":"Kim SM, Lim TJ, Paterno J, Kim DH (2004) A biomechanical comparison of supplementary posterior translaminar facet and transfacetopedicular screw fixation after anterior lumbar interbody fusion. J Neurosurg Spine 1:101\u2013107","journal-title":"J Neurosurg Spine"},{"key":"1052_CR16","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1007\/s005860000185","volume":"9","author":"C Knop","year":"2000","unstructured":"Knop C, Lange U, Bastian L, Blauth M (2000) Three-dimensional motion analysis with Synex. Comparative biomechanical test series with a new vertebral body replacement for the thoracolumbar spine. Eur Spine J 9:472\u2013485. doi: 10.1007\/s005860000185","journal-title":"Eur Spine J"},{"key":"1052_CR17","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1016\/j.spinee.2007.08.008","volume":"8","author":"K Meyers","year":"2008","unstructured":"Meyers K, Tauber M, Sudin Y, Fleischer S, Arnin U, Girardi F, Wright T (2008) Use of instrumented pedicle screws to evaluate load sharing in posterior dynamic stabilization systems. Spine J 8:926\u2013932. doi: 10.1016\/j.spinee.2007.08.008","journal-title":"Spine J"},{"key":"1052_CR18","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1007\/s00586-005-0948-9","volume":"15","author":"CA Niosi","year":"2006","unstructured":"Niosi CA, Zhu QA, Wilson DC, Keynan O, Wilson DR, Oxland TR (2006) Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study. Eur Spine J 15:913\u2013922. doi: 10.1007\/s00586-005-0948-9","journal-title":"Eur Spine J"},{"key":"1052_CR19","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1097\/00007632-198810000-00013","volume":"13","author":"MM Panjabi","year":"1988","unstructured":"Panjabi MM (1988) Biomechanical evaluation of spinal fixation devices: I. A conceptual framework. Spine 13:1129\u20131134","journal-title":"Spine"},{"key":"1052_CR20","doi-asserted-by":"crossref","first-page":"2159","DOI":"10.1007\/s00586-007-0444-5","volume":"16","author":"MM Panjabi","year":"2007","unstructured":"Panjabi MM, Henderson G, James Y, Timm JP (2007) StabilimaxNZ\u00ae versus simulated fusion: evaluation of adjacent-level effects. Eur Spine J 16:2159\u20132165. doi: 10.1007\/s00586-007-0444-5","journal-title":"Eur Spine J"},{"key":"1052_CR21","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1002\/jor.1100030305","volume":"3","author":"MM Panjabi","year":"1985","unstructured":"Panjabi MM, Krag M, Summers D, Videman T (1985) Biomechanical time-tolerance of fresh cadaveric human spine specimens. J Orthop Res 3:292\u2013300. doi: 10.1002\/jor.1100030305","journal-title":"J Orthop Res"},{"key":"1052_CR22","doi-asserted-by":"crossref","first-page":"413","DOI":"10.2106\/00004623-199403000-00012","volume":"76","author":"MM Panjabi","year":"1994","unstructured":"Panjabi MM, Oxland TR, Yamamoto I, Crisco JJ (1994) Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves. J Bone Joint Surg Am 76:413\u2013424","journal-title":"J Bone Joint Surg Am"},{"key":"1052_CR23","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1016\/j.spinee.2006.02.003","volume":"6","author":"FM Phillips","year":"2006","unstructured":"Phillips FM, Voronov LI, Gaitanis IN, Carandang G, Havey RM, Patwardhan AG (2006) Biomechanics of posterior dynamic stabilizing device (DIAM) after facetectomy and discectomy. Spine J 6:714\u2013722. doi: 10.1016\/j.spinee.2006.02.003","journal-title":"Spine J"},{"key":"1052_CR24","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1007\/s005860050062","volume":"7","author":"U Quint","year":"1998","unstructured":"Quint U, Wilke HJ, Loer F, Claes L (1998) Laminectomy and functional impairment of the lumbar spine: the importance of muscle forces in flexible and rigid instrumented stabilization\u2014a biomechanical study in vitro. Eur Spine J 7:229\u2013238. doi: 10.1007\/s005860050062","journal-title":"Eur Spine J"},{"key":"1052_CR25","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1097\/00024720-200308000-00015","volume":"16","author":"W Schmoelz","year":"2003","unstructured":"Schmoelz W, Huber JF, Nydegger T, Claes L, Wilke HJ (2003) Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech 16:418\u2013423","journal-title":"J Spinal Disord Tech"},{"key":"1052_CR26","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1007\/s00586-008-0667-0","volume":"17","author":"TL Schulte","year":"2008","unstructured":"Schulte TL, Hurschler C, Haversath M, Liljenqvist U, Bullmann V, Filler TJ, Osada N, Fallenberg EM, Hackenberg L (2008) The effect of dynamic, semi-rigid implants on the range of motion of lumbar motion segments after decompression. Eur Spine J 17:1057\u20131065. doi: 10.1007\/s00586-008-0667-0","journal-title":"Eur Spine J"},{"key":"1052_CR27","doi-asserted-by":"crossref","first-page":"2206","DOI":"10.1097\/00007632-199911010-00006","volume":"24","author":"JL Scifert","year":"1999","unstructured":"Scifert JL, Sairyo K, Goel VK, Grobler LJ, Grosland NM, Spratt KF, Chesmel KD (1999) Stability analysis of an enhanced load sharing posterior fixation device and its equivalent conventional device in a calf spine model. Spine 24:2206\u20132213. doi: 10.1097\/00007632-199911010-00006","journal-title":"Spine"},{"issue":"Suppl 2","key":"1052_CR28","doi-asserted-by":"crossref","first-page":"S170","DOI":"10.1007\/s00586-002-0438-2","volume":"11","author":"TM Stoll","year":"2002","unstructured":"Stoll TM, Dubois G, Schwarzenbach O (2002) The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 11(Suppl 2):S170\u2013S178","journal-title":"Eur Spine J"},{"key":"1052_CR29","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1007\/s00586-008-0657-2","volume":"17","author":"HJ Wilke","year":"2008","unstructured":"Wilke HJ, Drumm J, Haussler K, Mack C, Steudel WI, Kettler A (2008) Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure. Eur Spine J 17:1049\u20131056","journal-title":"Eur Spine J"},{"issue":"Suppl 1","key":"1052_CR30","doi-asserted-by":"crossref","first-page":"S313","DOI":"10.1016\/S0021-9290(08)70312-9","volume":"41","author":"HJ Wilke","year":"2008","unstructured":"Wilke HJ, Heuer F, Schmidt H (2008) Design optimization of a new posterior dynamic stabilization system. J Biomech 41(Suppl 1):S313. doi: 10.1016\/S0021-9290(08)70312-9","journal-title":"J Biomech"},{"key":"1052_CR31","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1002\/(SICI)1097-0185(199805)251:1<15::AID-AR4>3.0.CO;2-D","volume":"251","author":"HJ Wilke","year":"1998","unstructured":"Wilke HJ, Jungkunz B, Wenger K, Claes LE (1998) Spinal segment range of motion as a function of in vitro test conditions: effects of exposure period, accumulated cycles, angular-deformation rate, and moisture condition. Anat Rec 251:15\u201319. doi: 10.1002\/(SICI)1097-0185(199805)251:1<15::AID-AR4>3.0.CO;2-D","journal-title":"Anat Rec"},{"key":"1052_CR32","doi-asserted-by":"crossref","first-page":"2790","DOI":"10.1097\/01.brs.0000245872.45554.c0","volume":"31","author":"HJ Wilke","year":"2006","unstructured":"Wilke HJ, Schmidt H, Werner K, Schmolz W, Drumm J (2006) Biomechanical evaluation of a new total posterior-element replacement system. Spine 31:2790\u20132796. doi: 10.1097\/01.brs.0000245872.45554.c0 discussion 2797","journal-title":"Spine"},{"key":"1052_CR33","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1007\/s005860050045","volume":"7","author":"HJ Wilke","year":"1998","unstructured":"Wilke HJ, Wenger K, Claes L (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 7:148\u2013154. doi: 10.1007\/s005860050045","journal-title":"Eur Spine J"},{"key":"1052_CR34","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1007\/s00586-003-0540-0","volume":"12","author":"T Zander","year":"2003","unstructured":"Zander T, Rohlmann A, Klockner C, Bergmann G (2003) Influence of graded facetectomy and laminectomy on spinal biomechanics. Eur Spine J 12:427\u2013434. doi: 10.1007\/s00586-003-0540-0","journal-title":"Eur Spine J"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-009-1052-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00586-009-1052-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-009-1052-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,19]],"date-time":"2020-05-19T08:39:55Z","timestamp":1589877595000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00586-009-1052-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,6,6]]},"references-count":34,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2009,10]]}},"alternative-id":["1052"],"URL":"https:\/\/doi.org\/10.1007\/s00586-009-1052-3","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,6,6]]}}}