{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T11:19:51Z","timestamp":1761823191130},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2009,9,11]],"date-time":"2009-09-11T00:00:00Z","timestamp":1252627200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2010,1]]},"DOI":"10.1007\/s00586-009-1157-8","type":"journal-article","created":{"date-parts":[[2009,9,10]],"date-time":"2009-09-10T16:47:26Z","timestamp":1252601246000},"page":"78-84","source":"Crossref","is-referenced-by-count":18,"title":["Safety of thoracic pedicle screw application using the funnel technique in Asians: a cadaveric evaluation"],"prefix":"10.1007","volume":"19","author":[{"given":"Chris Yin Wei","family":"Chan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mun Keong","family":"Kwan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lim Beng","family":"Saw","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2009,9,11]]},"reference":[{"key":"1157_CR1","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1097\/01.BRS.0000106979.54651.D6","volume":"29","author":"HS An","year":"2004","unstructured":"An HS, Singh K, Vaccaro AR et al (2004) Biomechanical evaluation of contemporary posterior spinal internal fixation configurations in an unstable burst-fracture calf spine model: special references of hook configurations and pedicle screws. Spine 29:257\u2013262","journal-title":"Spine"},{"key":"1157_CR2","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.1097\/01.ta.0000215949.95089.18","volume":"60","author":"R Bransford","year":"2006","unstructured":"Bransford R, Bellabarba C, Thompson JH et al (2006) The safety of fluoroscopically-assisted thoracic pedicle screw instrumentation for spine trauma. J Trauma 60:1047\u20131052","journal-title":"J Trauma"},{"key":"1157_CR3","doi-asserted-by":"crossref","first-page":"S93","DOI":"10.1016\/j.spinee.2004.05.189","volume":"4","author":"P Cahill","year":"2004","unstructured":"Cahill P, Rinella AS, Ghanayem A et al (2004) Thoracic pedicle expansion after pedicle screw insertion in a pediatric cadaveric spine: a biomechanical analysis. Spine J 4:S93","journal-title":"Spine J"},{"key":"1157_CR4","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1097\/00007632-199901150-00003","volume":"24","author":"G Cinotti","year":"1999","unstructured":"Cinotti G, Stefano G, Ripani M et al (1999) Pedicle instrumentation in the thoracic spine: a morphometric and cadaveric study for placement of screws. Spine 24:114\u2013119","journal-title":"Spine"},{"key":"1157_CR5","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1097\/00007632-200406010-00004","volume":"29","author":"SP Datir","year":"2004","unstructured":"Datir SP, Mitra SR (2004) Morphometric study of the thoracic vertebral pedicle in an indian population. Spine 29:1174\u20131181","journal-title":"Spine"},{"key":"1157_CR6","doi-asserted-by":"crossref","first-page":"S2266","DOI":"10.1097\/00007632-199410151-00003","volume":"19","author":"CA Dickman","year":"1994","unstructured":"Dickman CA, Yahiro MA, Lu HT et al (1994) Surgical treatment alternatives for fixation of unstable fractures of the thoracic and lumbar spine. A meta-analysis. Spine 19:S2266\u2013S2273","journal-title":"Spine"},{"key":"1157_CR7","doi-asserted-by":"crossref","first-page":"2400","DOI":"10.1097\/01.brs.0000240212.31241.8e","volume":"31","author":"MB Dobbs","year":"2006","unstructured":"Dobbs MB, Lenke LG, Kim YJ et al (2006) Selective posterior thoracic fusions for adolescent idiopathic scoliosis: comparison of hooks versus pedicle screws. Spine 31:2400\u20132404","journal-title":"Spine"},{"key":"1157_CR8","doi-asserted-by":"crossref","first-page":"1458","DOI":"10.2106\/00004623-200010000-00013","volume":"82","author":"RW Gaines","year":"2000","unstructured":"Gaines RW (2000) Current concepts review: the use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82:1458\u20131476","journal-title":"J Bone Joint Surg Am"},{"key":"1157_CR9","doi-asserted-by":"crossref","first-page":"2040","DOI":"10.1097\/01.brs.0000138268.12324.1a","volume":"29","author":"YJ Kim","year":"2004","unstructured":"Kim YJ, Lenke LG, Cho SK et al (2004) Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis. Spine 29:2040\u20132048","journal-title":"Spine"},{"key":"1157_CR10","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1097\/01.brs.0000197865.20803.d4","volume":"31","author":"YJ Kim","year":"2006","unstructured":"Kim YJ, Lenke LG, Kim J et al (2006) Comparative analysis of pedicle screw versus hybrid instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis. Spine 31:291\u2013298","journal-title":"Spine"},{"key":"1157_CR11","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1097\/01.brs.0000209251.65417.16","volume":"31","author":"P Korovessis","year":"2006","unstructured":"Korovessis P, Baikousis A, Zacharatos S et al (2006) Combined anterior plus posterior stabilization versus posterior short-segment instrumentation and fusion for mid-lumbar (L2\u2013L4) burst fractures. Spine 31:859\u2013868","journal-title":"Spine"},{"key":"1157_CR12","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1097\/00007632-199108000-00006","volume":"16","author":"MM Panjabi","year":"1991","unstructured":"Panjabi MM, Takata K, Goel V et al (1991) Thoracic human vertebrae: quantitative three-dimensional anatomy. Spine 16:888\u2013901","journal-title":"Spine"},{"key":"1157_CR13","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1097\/00007632-200005010-00018","volume":"25","author":"JW Parker","year":"2000","unstructured":"Parker JW, Lane JR, Karaikovic E et al (2000) Successful short-segment instrumentation and fusion for thoracolumbar spine fractures: a consecutive 4\u00bd-year series. Spine 25:1157\u20131170","journal-title":"Spine"},{"key":"1157_CR14","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.jocn.2004.11.006","volume":"12","author":"M Payer","year":"2005","unstructured":"Payer M (2005) Unstable upper and middle thoracic fractures. Preliminary experience with a posterior transpedicular correction-fixation method. J Clin Neurochir 12:529\u2013533","journal-title":"J Clin Neurochir"},{"key":"1157_CR15","doi-asserted-by":"crossref","first-page":"E56","DOI":"10.1097\/01.brs.0000252094.64857.ab","volume":"32","author":"S Rajasekaran","year":"2007","unstructured":"Rajasekaran S, Vidyadhara S, Perumal M et al (2007) Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine 32:E56\u2013E64","journal-title":"Spine"},{"key":"1157_CR16","first-page":"223s","volume":"97","author":"G Rao","year":"2002","unstructured":"Rao G, Brodke DS, Rondina M et al (2002) Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement. J Neurosurg 97:223s\u2013226s","journal-title":"J Neurosurg"},{"key":"1157_CR17","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1097\/00007632-198810000-00002","volume":"13","author":"PV Scoles","year":"1988","unstructured":"Scoles PV, Linton AE, Latimer B et al (1988) Vertebral body and posterior element morphology: the normal spine in middle life. Spine 13:1082\u20131086","journal-title":"Spine"},{"key":"1157_CR18","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1007\/s00586-003-0586-z","volume":"13","author":"SH Tan","year":"2004","unstructured":"Tan SH, Teo EC, Chua HC (2004) Quantitative three dimensional anatomy of cervical, thoracic and lumbar vertebrae in Chinese Singaporean. Eur Spine J 13:137\u2013146","journal-title":"Eur Spine J"},{"key":"1157_CR19","first-page":"5","volume":"10","author":"S Thanapipatsiri","year":"1996","unstructured":"Thanapipatsiri S, Meknavin S, Chavisiri C et al (1996) Pedicle sizes of the thoracic vertebrae from T1 to T12 in Thai adults. J Asian Orthop Assoc 10:5\u20138","journal-title":"J Asian Orthop Assoc"},{"key":"1157_CR20","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.2106\/00004623-199508000-00008","volume":"77","author":"AR Vaccaro","year":"1995","unstructured":"Vaccaro AR, Rizzolo SJ, Allardyce TJ et al (1995) Placement of pedicle screws in the thoracic spine. Part 1. Morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 77:1193\u20131199","journal-title":"J Bone Joint Surg Am"},{"key":"1157_CR21","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.2106\/00004623-199508000-00009","volume":"77","author":"AR Vaccaro","year":"1995","unstructured":"Vaccaro AR, Rizzolo S, Balderston RA et al (1995) Placement of pedicle screws in the thoracic spine. Part 2. An anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200\u20131206","journal-title":"J Bone Joint Surg Am"},{"key":"1157_CR22","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1097\/00024720-200212000-00002","volume":"15","author":"M Viau","year":"2002","unstructured":"Viau M, Tarbox BB, Wonglertsiri S et al (2002) Thoracic pedicle screw instrumentation using the \u201cfunnel technique\u201d. Part 2. Clinical experience. J Spinal Disord 15:450\u2013453","journal-title":"J Spinal Disord"},{"key":"1157_CR23","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1097\/00024720-200212000-00001","volume":"15","author":"W Yingsakmonkol","year":"2002","unstructured":"Yingsakmonkol W, Karaikovic E, Gaines RW (2002) The accuracy of pedicle screw placement in the thoracic spine using the \u201cfunnel technique\u201d. Part 1. A cadaveric study. J Spinal Disord 15:445\u2013449","journal-title":"J Spinal Disord"},{"key":"1157_CR24","doi-asserted-by":"crossref","first-page":"2782","DOI":"10.1097\/00007632-200212150-00008","volume":"27","author":"JJ Yue","year":"2002","unstructured":"Yue JJ, Sossan A, Selgrath C et al (2002) The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: a 3-year consecutive series. Spine 27:2782\u20132787","journal-title":"Spine"},{"key":"1157_CR25","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1097\/00007632-198703000-00012","volume":"12","author":"MR Zindrick","year":"1987","unstructured":"Zindrick MR, Wiltse LL, Doornik A et al (1987) Analysis of morphometric characteristics of the thoracic and lumbar pedicles. Spine 12:160\u2013166","journal-title":"Spine"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-009-1157-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00586-009-1157-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-009-1157-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T03:24:13Z","timestamp":1559100253000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00586-009-1157-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,9,11]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,1]]}},"alternative-id":["1157"],"URL":"https:\/\/doi.org\/10.1007\/s00586-009-1157-8","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,9,11]]}}}