{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,21]],"date-time":"2026-03-21T09:14:10Z","timestamp":1774084450696,"version":"3.50.1"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,8,14]],"date-time":"2019-08-14T00:00:00Z","timestamp":1565740800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,8,14]],"date-time":"2019-08-14T00:00:00Z","timestamp":1565740800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100003359","name":"Scoliosis Research Society","doi-asserted-by":"publisher","award":["New Investigator Grant"],"award-info":[{"award-number":["New Investigator Grant"]}],"id":[{"id":"10.13039\/100003359","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2020,1]]},"DOI":"10.1007\/s00586-019-06087-x","type":"journal-article","created":{"date-parts":[[2019,8,14]],"date-time":"2019-08-14T22:02:31Z","timestamp":1565820151000},"page":"36-44","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Biomechanical in vitro comparison between anterior column realignment and pedicle subtraction osteotomy for severe sagittal imbalance correction"],"prefix":"10.1007","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9822-2116","authenticated-orcid":false,"given":"Luigi","family":"La Barbera","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hans-Joachim","family":"Wilke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Liebsch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomaso","family":"Villa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Luca","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fabio","family":"Galbusera","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marco","family":"Brayda-Bruno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,8,14]]},"reference":[{"issue":"6","key":"6087_CR1","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1007\/s00586-014-3227-9","volume":"23","author":"C Lamartina","year":"2014","unstructured":"Lamartina C, Berjano P (2014) Classification of sagittal imbalance based on spinal alignment and compensatory mechanisms. Eur Spine J 23(6):1177\u20131189. \nhttps:\/\/doi.org\/10.1007\/s00586-014-3227-9","journal-title":"Eur Spine J"},{"issue":"Suppl 6","key":"6087_CR2","doi-asserted-by":"publisher","first-page":"S853","DOI":"10.1007\/s00586-013-3024-x","volume":"22","author":"P Berjano","year":"2013","unstructured":"Berjano P, Bassani R, Casero G, Sinigaglia A, Cecchinato R, Lamartina C (2013) Failures and revisions in surgery for sagittal imbalance: analysis of factors influencing failure. Eur Spine J 22(Suppl 6):S853\u2013S858. \nhttps:\/\/doi.org\/10.1007\/s00586-013-3024-x","journal-title":"Eur Spine J"},{"issue":"10","key":"6087_CR3","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1097\/BRS.0b013e3181e21783","volume":"36","author":"JS Smith","year":"2011","unstructured":"Smith JS, Shaffrey CI, Glassman SD, Berven SH, Schwab FJ, Hamill CL, Horton WC, Ondra SL, Sansur CA, Bridwell KH, Spinal Deformity Study Group (2011) Risk-benefit assessment of surgery for adult scoliosis: an analysis based on patient age. Spine (Phila Pa 1976) 36(10):817\u2013824. \nhttps:\/\/doi.org\/10.1097\/BRS.0b013e3181e21783","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"6087_CR4","doi-asserted-by":"publisher","first-page":"E4","DOI":"10.3171\/2009.12.FOCUS09259","volume":"28","author":"IG Dorward","year":"2010","unstructured":"Dorward IG, Lenke LG (2010) Osteotomies in the posterior-only treatment of complex adult spinal deformity: a comparative review. Neurosurg Focus 28(3):E4. \nhttps:\/\/doi.org\/10.3171\/2009.12.FOCUS09259","journal-title":"Neurosurg Focus"},{"issue":"9","key":"6087_CR5","doi-asserted-by":"publisher","first-page":"2357","DOI":"10.1007\/s00586-018-5623-z","volume":"27","author":"L La Barbera","year":"2018","unstructured":"La Barbera L, Brayda-Bruno M, Liebsch C, Villa T, Luca A, Galbusera F, Wilke HJ (2018) Biomechanical advantages of supplemental accessory and satellite rods with and without interbody cages implantation for the stabilization of pedicle subtraction osteotomy. Eur Spine J 27(9):2357\u20132366. \nhttps:\/\/doi.org\/10.1007\/s00586-018-5623-z","journal-title":"Eur Spine J"},{"issue":"4","key":"6087_CR6","doi-asserted-by":"publisher","first-page":"444","DOI":"10.3171\/2016.10.SPINE16849","volume":"27","author":"JS Smith","year":"2017","unstructured":"Smith JS, Shaffrey CI, Klineberg E et al (2017) Complication rates associated with 3-column osteotomy in 82 adult spinal deformity patients: retrospective review of a prospectively collected multicenter consecutive series with 2-year follow-up. J Neurosurg Spine 27(4):444\u2013457. \nhttps:\/\/doi.org\/10.3171\/2016.10.SPINE16849","journal-title":"J Neurosurg Spine"},{"key":"6087_CR7","doi-asserted-by":"publisher","first-page":"454","DOI":"10.2106\/00004623-200303000-00009","volume":"85","author":"KH Bridwell","year":"2003","unstructured":"Bridwell KH, Lewis SJ, Lenke LG (2003) Pedicle subtraction osteotomy for the treatment of fixed sagittal imbalance. J Bone Jt Surg Am 85:454\u2013463","journal-title":"J Bone Jt Surg Am"},{"issue":"4","key":"6087_CR8","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1227\/NEU.0b013e3182672aab","volume":"71","author":"JS Smith","year":"2012","unstructured":"Smith JS, Shaffrey CI, Ames CP, Demakakos J, Fu KMG, Keshavarzi S, Li CMY, Deviren V, Schwab FJ, Lafage V, Bess S (2012) Assessment of symptomatic rod fracture after posterior instrumented fusion for adult spinal deformity. Neurosurgery 71(4):862\u2013867. \nhttps:\/\/doi.org\/10.1227\/NEU.0b013e3182672aab","journal-title":"Neurosurgery"},{"issue":"6","key":"6087_CR9","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1007\/s00586-014-3555-9","volume":"23","author":"A Luca","year":"2014","unstructured":"Luca A, Lovi A, Galbusera F, Brayda-Bruno M (2014) Revision surgery after PSO failure with rod breakage: a comparison of different techniques. Eur Spine J 23(6):610\u2013615. \nhttps:\/\/doi.org\/10.1007\/s00586-014-3555-9","journal-title":"Eur Spine J"},{"key":"6087_CR10","doi-asserted-by":"publisher","DOI":"10.1093\/ons\/opx151","author":"S Gupta","year":"2017","unstructured":"Gupta S, Eksi MS, Ames CP, Deviren V, Durbin-Johnson B, Smith JS, Gupta MC (2017) A novel 4-rod technique offers potential to reduce rod breakage and pseudarthrosis in pedicle subtraction osteotomies for adult spinal deformity correction. Oper Neurosurg (Hagerstown). \nhttps:\/\/doi.org\/10.1093\/ons\/opx151","journal-title":"Oper Neurosurg (Hagerstown)"},{"issue":"22","key":"6087_CR11","doi-asserted-by":"publisher","first-page":"1899","DOI":"10.1097\/BRS.0000000000000556","volume":"39","author":"SJ Hyun","year":"2014","unstructured":"Hyun SJ, Lenke LG, Kim YC, Koester L, Blanke KM (2014) Comparison of standard 2-rod constructs to multiple-rod constructs for fixation across 3-column spinal osteotomies. Spine 39(22):1899\u20131904. \nhttps:\/\/doi.org\/10.1097\/BRS.0000000000000556","journal-title":"Spine"},{"issue":"20","key":"6087_CR12","doi-asserted-by":"publisher","first-page":"2189","DOI":"10.1097\/BRS.0b013e31814b8371","volume":"32","author":"YJ Kim","year":"2007","unstructured":"Kim YJ, Bridwell KH, Lenke LG, Cheh G, Baldus C (2007) Results of lumbar pedicle subtraction osteotomies for fixed sagittal imbalance: a minimum 5-year follow-up study. Spine 32(20):2189\u20132197. \nhttps:\/\/doi.org\/10.1097\/BRS.0b013e31814b8371","journal-title":"Spine"},{"issue":"Suppl. 8","key":"6087_CR13","doi-asserted-by":"publisher","first-page":"S66","DOI":"10.1097\/BRS.0000000000001483","volume":"41","author":"R Saigal","year":"2016","unstructured":"Saigal R, Mundis GM Jr, Eastlack R, Uribe JS, Phillips FM, Akbarnia BA (2016) Anterior column realignment (ACR) in adult sagittal deformity correction: technique and review of the literature. Spine (Phila Pa 1976) 41(Suppl. 8):S66\u2013S73. \nhttps:\/\/doi.org\/10.1097\/BRS.0000000000001483","journal-title":"Spine (Phila Pa 1976)"},{"issue":"5","key":"6087_CR14","doi-asserted-by":"publisher","first-page":"565","DOI":"10.3171\/2018.4.SPINE171206","volume":"29","author":"JS Uribe","year":"2019","unstructured":"Uribe JS, Schwab F, Mundis GM, Xu DS, Januszewski J, Kanter AS, Okonkwo DO, Hu SS, Vedat D, Eastlack R, Berjano P, Mummaneni PV (2019) The comprehensive anatomical spinal osteotomy and anterior column realignment classification. J Neurosurg Spine 29(5):565\u2013575. \nhttps:\/\/doi.org\/10.3171\/2018.4.SPINE171206","journal-title":"J Neurosurg Spine"},{"key":"6087_CR15","doi-asserted-by":"publisher","first-page":"e379","DOI":"10.1016\/j.wneu.2018.11.174","volume":"123","author":"ZB Cheung","year":"2019","unstructured":"Cheung ZB, Chen DH, White SJW, Kim JS, Cho SK (2019) Anterior column realignment in adult spinal deformity: a case report and review of the literature. World Neurosurg 123:e379\u2013e386. \nhttps:\/\/doi.org\/10.1016\/j.wneu.2018.11.174","journal-title":"World Neurosurg"},{"key":"6087_CR16","doi-asserted-by":"publisher","first-page":"789698","DOI":"10.1100\/2012\/789698","volume":"2012","author":"AR Deukmedjian","year":"2012","unstructured":"Deukmedjian AR, Dakwar E, Ahmadian A, Smith DA, Uribe JS (2012) Early outcomes of minimally invasive anterior longitudinal ligament release for correction of sagittal imbalance in patients with adult spinal deformity. Sci World J 2012:789698. \nhttps:\/\/doi.org\/10.1100\/2012\/789698","journal-title":"Sci World J"},{"key":"6087_CR17","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1016\/j.wneu.2017.05.122","volume":"105","author":"GM Mundis Jr","year":"2017","unstructured":"Mundis GM Jr, Turner JD, Kabirian N, Pawelek J, Eastlack RK, Uribe J, Klineberg E, Bess S, Ames C, Deviren V, Nguyen S, Lafage V, Akbarnia BA, International Spine Study Group (2017) Anterior column realignment has similar results to pedicle subtraction osteotomy in treating adults with sagittal plane deformity. World Neurosurg 105:249\u2013256. \nhttps:\/\/doi.org\/10.1016\/j.wneu.2017.05.122","journal-title":"World Neurosurg"},{"issue":"6","key":"6087_CR18","doi-asserted-by":"publisher","first-page":"530539","DOI":"10.3171\/2012.8.SPINE12432","volume":"17","author":"AR Deukmedjian","year":"2012","unstructured":"Deukmedjian AR, Le TV, Baaj AA, Dakwar E, Smith DA, Uribe JS (2012) Anterior longitudinal ligament release using the minimally invasive lateral retroperitoneal transpsoas approach: a cadaveric feasibility study and report of 4 clinical cases. J Neurosurg Spine 17(6):530539. \nhttps:\/\/doi.org\/10.3171\/2012.8.SPINE12432","journal-title":"J Neurosurg Spine"},{"issue":"6","key":"6087_CR19","doi-asserted-by":"publisher","first-page":"E6","DOI":"10.3171\/2017.8.FOCUS17423","volume":"43","author":"P Hosseini","year":"2017","unstructured":"Hosseini P, Mundis GM Jr, Eastlack RK, Bagheri R, Vargas E, Tran S, Akbarnia BA (2017) Preliminary results of anterior lumbar interbody fusion, anterior column realignment for the treatment of sagittal malalignment. Neurosurg Focus 43(6):E6. \nhttps:\/\/doi.org\/10.3171\/2017.8.FOCUS17423","journal-title":"Neurosurg Focus"},{"issue":"Suppl 3","key":"6087_CR20","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1007\/s00586-015-3930-1","volume":"24","author":"P Berjano","year":"2015","unstructured":"Berjano P, Cecchinato R, Sinigaglia A, Damilano M, Ismael MF, Martini C, Villafa\u00f1e JH, Lamartina C (2015) Anterior column realignment from a lateral approach for the treatment of severe sagittal imbalance: a retrospective radiographic study. Eur Spine J 24(Suppl 3):433\u2013438. \nhttps:\/\/doi.org\/10.1007\/s00586-015-3930-1","journal-title":"Eur Spine J"},{"issue":"1","key":"6087_CR21","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1097\/BSD.0b013e318287bdc1","volume":"27","author":"BA Akbarnia","year":"2014","unstructured":"Akbarnia BA, Mundis GM Jr, Moazzaz P, Kabirian N, Bagheri R, Eastlack RK, Pawelek JB (2014) Anterior column realignment (ACR) for focal kyphotic spinal deformity using a lateral transpsoas approach and ALL release. J Spinal Disord Tech 27(1):29\u201339. \nhttps:\/\/doi.org\/10.1097\/BSD.0b013e318287bdc1","journal-title":"J Spinal Disord Tech"},{"issue":"14","key":"6087_CR22","doi-asserted-by":"publisher","first-page":"1268","DOI":"10.1097\/BRS.0b013e3182458b2f","volume":"37","author":"TV Le","year":"2012","unstructured":"Le TV, Baaj AA, Dakwar E, Burkett CJ, Murray G, Smith DA, Uribe JS (2012) Subsidence of polyetheretherketone intervertebral cages in minimally invasive lateral retroperitoneal transpsoas lumbar interbody fusion. Spine (Phila Pa 1976) 37(14):1268\u20131273. \nhttps:\/\/doi.org\/10.1097\/BRS.0b013e3182458b2f","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"6087_CR23","doi-asserted-by":"publisher","first-page":"764","DOI":"10.1007\/s00586-016-4859-8","volume":"26","author":"A Luca","year":"2017","unstructured":"Luca A, Ottardi C, Sasso M, Prosdocimo L, La Barbera L, Brayda-Bruno M, Galbusera F, Villa T (2017) Instrumentation failure following pedicle subtraction osteotomy: the role of rod material, diameter, and multi-rod constructs. Eur Spine J 26(3):764\u2013770. \nhttps:\/\/doi.org\/10.1007\/s00586-016-4859-8","journal-title":"Eur Spine J"},{"issue":"Suppl 4","key":"6087_CR24","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1007\/s00586-017-5084-9","volume":"26","author":"A Luca","year":"2017","unstructured":"Luca A, Ottardi C, Lovi A, Brayda-Bruno M, Villa T, Galbusera F (2017) Anterior support reduces the stresses on the posterior instrumentation after pedicle subtraction osteotomy: a finite-element study. Eur Spine J 26(Suppl 4):450\u2013456. \nhttps:\/\/doi.org\/10.1007\/s00586-017-5084-9","journal-title":"Eur Spine J"},{"key":"6087_CR25","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1016\/j.clinbiomech.2017.02.006","volume":"43","author":"C Kim","year":"2017","unstructured":"Kim C, Harris JA, Muzumdar A, Khalil S, Sclafani JA, Raiszadeh K, Bucklen BS (2017) The effect of anterior longitudinal ligament resection on lordosis correction during minimally invasive lateral lumbar interbody fusion: biomechanical and radiographic feasibility of an integrated spacer\/plate interbody reconstruction device. Clin Biomech (Bristol Avon) 43:102\u2013108. \nhttps:\/\/doi.org\/10.1016\/j.clinbiomech.2017.02.006","journal-title":"Clin Biomech (Bristol Avon)"},{"issue":"5","key":"6087_CR26","doi-asserted-by":"publisher","first-page":"476","DOI":"10.3171\/2012.8.SPINE111121","volume":"17","author":"JS Uribe","year":"2012","unstructured":"Uribe JS, Smith DA, Dakwar E, Baaj AA, Mundis GM, Turner AW, Cornwall GB, Akbarnia BA (2012) Lordosis restoration after anterior longitudinal ligament release and placement of lateral hyperlordotic interbody cages during the minimally invasive lateral transpsoas approach: a radiographic study in cadavers. J Neurosurg Spine 17(5):476\u2013485. \nhttps:\/\/doi.org\/10.3171\/2012.8.SPINE111121","journal-title":"J Neurosurg Spine"},{"issue":"Suppl 3","key":"6087_CR27","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1007\/s00586-015-3872-7","volume":"24","author":"JS Uribe","year":"2015","unstructured":"Uribe JS, Harris JE, Beckman JM, Turner AW, Mundis GM, Akbarnia BA (2015) Finite element analysis of lordosis restoration with anterior longitudinal ligament release and lateral hyperlordotic cage placement. Eur Spine J 24(Suppl 3):420\u2013426. \nhttps:\/\/doi.org\/10.1007\/s00586-015-3872-7","journal-title":"Eur Spine J"},{"issue":"1","key":"6087_CR28","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.spinee.2012.11.013","volume":"13","author":"MB Kornblum","year":"2013","unstructured":"Kornblum MB, Turner AW, Cornwall GB, Zatushevsky MA, Phillips FM (2013) Biomechanical evaluation of stand-alone lumbar polyether-ether-ketone interbody cage with integrated screws. Spine J 13(1):77\u201384. \nhttps:\/\/doi.org\/10.1016\/j.spinee.2012.11.013","journal-title":"Spine J"},{"issue":"10","key":"6087_CR29","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1097\/BRS.0b013e31823551aa","volume":"37","author":"CJ Laws","year":"2012","unstructured":"Laws CJ, Coughlin DG, Lotz JC, Serhan HA, Hu SS (2012) Direct lateral approach to lumbar fusion is a biomechanically equivalent alternative to the anterior approach: an in vitro study. Spine (Phila Pa 1976) 37(10):819\u2013825. \nhttps:\/\/doi.org\/10.1097\/BRS.0b013e31823551aa","journal-title":"Spine (Phila Pa 1976)"},{"issue":"26 Suppl","key":"6087_CR30","doi-asserted-by":"publisher","first-page":"S361","DOI":"10.1097\/BRS.0b013e318202308b","volume":"35","author":"A Cappuccino","year":"2010","unstructured":"Cappuccino A, Cornwall GB, Turner AW, Fogel GR, Duong HT, Kim KD, Brodke DS (2010) Biomechanical analysis and review of lateral lumbar fusion constructs. Spine (Phila Pa 1976) 35(26 Suppl):S361\u2013S367. \nhttps:\/\/doi.org\/10.1097\/BRS.0b013e318202308b","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"6087_CR31","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1097\/BSD.0b013e318060092f","volume":"21","author":"A Ploumis","year":"2008","unstructured":"Ploumis A, Wu C, Fischer G, Mehbod AA, Wu W, Faundez A, Transfeldt EE (2008) Biomechanical comparison of anterior lumbar interbody fusion and transforaminal lumbar interbody fusion. J Spinal Disord Tech 21(2):120\u2013125. \nhttps:\/\/doi.org\/10.1097\/BSD.0b013e318060092f","journal-title":"J Spinal Disord Tech"},{"key":"6087_CR32","doi-asserted-by":"publisher","first-page":"207","DOI":"10.4103\/sni.sni_44_17.eCollection","volume":"8","author":"J Januszewski","year":"2017","unstructured":"Januszewski J, Beckman JM, Harris JE, Turner AW, Yen CP (2017) Uribe JS (2017) Biomechanical study of rod stress after pedicle subtraction osteotomy versus anterior column reconstruction: a finite element study. Surg Neurol Int 8:207. \nhttps:\/\/doi.org\/10.4103\/sni.sni_44_17","journal-title":"Surg Neurol Int"},{"issue":"10","key":"6087_CR33","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1097\/BRS.0b013e31816f5f23","volume":"33","author":"K Watanabe","year":"2008","unstructured":"Watanabe K, Lenke LG, Daubs MD, Kim YW, Kim YB, Watanabe K, Stobbs G (2008) A central hook-rod construct for osteotomy closure: a technical note. Spine (Phila Pa 1976) 33(10):1149\u20131155. \nhttps:\/\/doi.org\/10.1097\/BRS.0b013e31816f5f23","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"6087_CR34","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1007\/BF02221446","volume":"3","author":"H-J Wilke","year":"1994","unstructured":"Wilke H-J, Claes L, Schmitt H, Wolf S (1994) A universal spine tester for in vitro experiments with muscle force simulation. Eur Spine J 3(2):91\u201397","journal-title":"Eur Spine J"},{"issue":"2","key":"6087_CR35","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1177\/0954411916684365","volume":"231","author":"L La Barbera","year":"2017","unstructured":"La Barbera L, Villa T (2017) Toward the definition of a new worst-case paradigm for the preclinical evaluation of posterior spine stabilization devices. Proc Inst Mech Eng H 231(2):176\u2013185. \nhttps:\/\/doi.org\/10.1177\/0954411916684365","journal-title":"Proc Inst Mech Eng H"},{"issue":"2","key":"6087_CR36","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1177\/0954411915621587","volume":"230","author":"L La Barbera","year":"2016","unstructured":"La Barbera L, Villa T (2016) ISO 12189 standard for the preclinical evaluation of posterior spinal stabilization devices\u2014I: assembly procedure and validation. Proc Inst Mech Eng H 230(2):122\u2013133. \nhttps:\/\/doi.org\/10.1177\/0954411915621587","journal-title":"Proc Inst Mech Eng H"},{"issue":"10","key":"6087_CR37","doi-asserted-by":"publisher","first-page":"2290","DOI":"10.1016\/j.spinee.2015.07.461","volume":"15","author":"L La Barbera","year":"2015","unstructured":"La Barbera L, Ottardi C, Villa T (2015) Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems: the importance of preload in ISO 12189. Spine J 15(10):2290\u20132296. \nhttps:\/\/doi.org\/10.1016\/j.spinee.2015.07.461","journal-title":"Spine J"},{"key":"6087_CR38","doi-asserted-by":"publisher","first-page":"1629","DOI":"10.1016\/j.spinee.2015.03.010","volume":"15","author":"RA Lehman","year":"2015","unstructured":"Lehman RA, Kang DG, Wagner SC, Paik H, Cardoso MJ, Bernstock JD, Dmitriev AE (2015) Biomechanical stability of transverse connectors in the setting of a thoracic pedicle subtraction osteotomy. Spine J 15:1629\u20131635. \nhttps:\/\/doi.org\/10.1016\/j.spinee.2015.03.010","journal-title":"Spine J"},{"issue":"2","key":"6087_CR39","doi-asserted-by":"publisher","first-page":"184","DOI":"10.3171\/2010.9.SPINE10129","volume":"14","author":"V Lafage","year":"2011","unstructured":"Lafage V, Schwab F, Vira S, Hart R, Burton D, Smith JS, Boachie-Adjei O, Shelokov A, Hostin R, Shaffrey CI, Gupta M, Akbarnia BA, Bess S, Farcy JP (2011) Does vertebral level of pedicle subtraction osteotomy correlate with degree of spinopelvic parameter correction? J Neurosurg Spine 14(2):184\u2013191. \nhttps:\/\/doi.org\/10.3171\/2010.9.SPINE10129","journal-title":"J Neurosurg Spine"},{"issue":"Suppl 1","key":"6087_CR40","doi-asserted-by":"publisher","first-page":"S49","DOI":"10.1007\/s00586-014-3670-7","volume":"24","author":"P Berjano","year":"2015","unstructured":"Berjano P, Aebi M (2015) Pedicle subtraction osteotomies (PSO) in the lumbar spine for sagittal deformities. Eur Spine J 24(Suppl 1):S49\u201357. \nhttps:\/\/doi.org\/10.1007\/s00586-014-3670-7","journal-title":"Eur Spine J"},{"key":"6087_CR41","doi-asserted-by":"publisher","DOI":"10.1115\/1.4040451","author":"F Berti","year":"2018","unstructured":"Berti F, La Barbera L, Piovesan A, Allegretti D, Ottardi C, Villa T, Pennati G (2018) Residual stresses in titanium spinal rods: effects of two contouring methods and material plastic properties. J Biomech Eng. \nhttps:\/\/doi.org\/10.1115\/1.4040451","journal-title":"J Biomech Eng"},{"key":"6087_CR42","doi-asserted-by":"publisher","DOI":"10.1115\/1.4042767","author":"A Piovesan","year":"2019","unstructured":"Piovesan A, Berti F, Villa T, Pennati G, La Barbera L (2019) Computational and experimental fatigue analysis of contoured spinal rods. J Biomech Eng. \nhttps:\/\/doi.org\/10.1115\/1.4042767","journal-title":"J Biomech Eng"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-019-06087-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00586-019-06087-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-019-06087-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,8,12]],"date-time":"2020-08-12T23:09:10Z","timestamp":1597273750000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00586-019-06087-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,14]]},"references-count":42,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,1]]}},"alternative-id":["6087"],"URL":"https:\/\/doi.org\/10.1007\/s00586-019-06087-x","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,14]]},"assertion":[{"value":"22 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 June 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 July 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 August 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest related to the content of the current study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}