{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T11:17:54Z","timestamp":1776943074843,"version":"3.51.4"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2021,1,3]],"date-time":"2021-01-03T00:00:00Z","timestamp":1609632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,1,3]],"date-time":"2021-01-03T00:00:00Z","timestamp":1609632000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2021,5]]},"DOI":"10.1007\/s00586-020-06673-4","type":"journal-article","created":{"date-parts":[[2021,1,3]],"date-time":"2021-01-03T01:02:37Z","timestamp":1609635757000},"page":"1303-1313","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Impact of mechanical stability on the progress of bone ongrowth on the frame surfaces of a titanium-coated PEEK cage and a 3D porous titanium alloy cage: in vivo analysis using CT color mapping"],"prefix":"10.1007","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5652-1919","authenticated-orcid":false,"given":"Takahiro","family":"Makino","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9956-5914","authenticated-orcid":false,"given":"Shota","family":"Takaneka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7896-7639","authenticated-orcid":false,"given":"Yusuke","family":"Sakai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7697-8035","authenticated-orcid":false,"given":"Hideki","family":"Yoshikawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4882-2997","authenticated-orcid":false,"given":"Takashi","family":"Kaito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,1,3]]},"reference":[{"key":"6673_CR1","doi-asserted-by":"publisher","first-page":"1250","DOI":"10.1016\/j.spinee.2018.02.018","volume":"18","author":"KC McGilvray","year":"2018","unstructured":"McGilvray KC, Easley J, Seim HB, Regan D, Berven SH, Hsu WK, Mroz TE, Puttlitz CM (2018) Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model. Spine J 18:1250\u20131260. https:\/\/doi.org\/10.1016\/j.spinee.2018.02.018","journal-title":"Spine J"},{"key":"6673_CR2","doi-asserted-by":"publisher","first-page":"1907","DOI":"10.1016\/j.spinee.2017.06.034","volume":"17","author":"KC McGilvray","year":"2017","unstructured":"McGilvray KC, Waldorff EI, Easley J, Seim HB, Zhang N, Linovitz RJ, Ryaby JT, Puttlitz CM (2017) Evaluation of a polyetheretherketone (PEEK) titanium composite interbody spacer in an ovine lumbar interbody fusion model: biomechanical, microcomputed tomographic, and histologic analyses. Spine J 17:1907\u20131916. https:\/\/doi.org\/10.1016\/j.spinee.2017.06.034","journal-title":"Spine J"},{"key":"6673_CR3","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.1016\/j.spinee.2014.12.018","volume":"15","author":"WR Walsh","year":"2015","unstructured":"Walsh WR, Bertollo N, Christou C, Schaffner D, Mobbs RJ (2015) Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface. Spine J 15:1041\u20131049. https:\/\/doi.org\/10.1016\/j.spinee.2014.12.018","journal-title":"Spine J"},{"key":"6673_CR4","doi-asserted-by":"publisher","first-page":"1231","DOI":"10.1016\/j.spinee.2018.02.017","volume":"18","author":"WR Walsh","year":"2018","unstructured":"Walsh WR, Pelletier MH, Christou C, He J, Vizesi F, Boden SD (2018) The in vivo response to a novel Ti coating compared with polyether ether ketone: evaluation of the periphery and inner surfaces of an implant. Spine J 18:1231\u20131240. https:\/\/doi.org\/10.1016\/j.spinee.2018.02.017","journal-title":"Spine J"},{"key":"6673_CR5","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1007\/s00256-009-0733-7","volume":"39","author":"J Shinbo","year":"2010","unstructured":"Shinbo J, Mainil-Varlet P, Watanabe A, Pippig S, Koener J, Anderson SE (2010) Evaluation of early tissue reactions after lumbar intertransverse process fusion using CT in a rabbit. Skeletal Radiol 39:369\u2013373. https:\/\/doi.org\/10.1007\/s00256-009-0733-7","journal-title":"Skeletal Radiol"},{"key":"6673_CR6","doi-asserted-by":"publisher","first-page":"e12379","DOI":"10.1097\/MD.0000000000012379","volume":"97","author":"T Makino","year":"2018","unstructured":"Makino T, Kaito T, Sakai Y, Takenaka S, Yoshikawa H (2018) Computed tomography color mapping for evaluation of bone ongrowth on the surface of a titanium-coated polyetheretherketone cage in vivo: a pilot study. Medicine 97:e12379. https:\/\/doi.org\/10.1097\/MD.0000000000012379","journal-title":"Medicine"},{"key":"6673_CR7","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.2106\/jbjs.j.00160","volume":"93","author":"JJ Schreiber","year":"2011","unstructured":"Schreiber JJ, Anderson PA, Rosas HG, Buchholz AL, Au AG (2011) Hounsfield units for assessing bone mineral density and strength: a tool for osteoporosis management. J Bone Joint Surg Am 93:1057\u20131063. https:\/\/doi.org\/10.2106\/jbjs.j.00160","journal-title":"J Bone Joint Surg Am"},{"key":"6673_CR8","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159\u2013174","journal-title":"Biometrics"},{"key":"6673_CR9","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.jocn.2015.07.017","volume":"24","author":"K Phan","year":"2016","unstructured":"Phan K, Hogan JA, Assem Y, Mobbs RJ (2016) PEEK-Halo effect in interbody fusion. J Clin Neurosci 24:138\u2013140. https:\/\/doi.org\/10.1016\/j.jocn.2015.07.017","journal-title":"J Clin Neurosci"},{"key":"6673_CR10","first-page":"253","volume":"7","author":"R Dimitriou","year":"2007","unstructured":"Dimitriou R, Babis GC (2007) Biomaterial osseointegration enhancement with biophysical stimulation. J Musculoskelet Neuronal Interact 7:253\u2013265","journal-title":"J Musculoskelet Neuronal Interact"},{"key":"6673_CR11","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1016\/j.micron.2005.07.008","volume":"36","author":"F Marco","year":"2005","unstructured":"Marco F, Milena F, Gianluca G, Vittoria O (2005) Peri-implant osteogenesis in health and osteoporosis. Micron 36:630\u2013644. https:\/\/doi.org\/10.1016\/j.micron.2005.07.008 (Oxford, England: 1993)","journal-title":"Micron"},{"key":"6673_CR12","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.spinee.2012.02.002","volume":"12","author":"R Olivares-Navarrete","year":"2012","unstructured":"Olivares-Navarrete R, Gittens RA, Schneider JM, Hyzy SL, Haithcock DA, Ullrich PF, Schwartz Z, Boyan BD (2012) Osteoblasts exhibit a more differentiated phenotype and increased bone morphogenetic protein production on titanium alloy substrates than on poly-ether-ether-ketone. Spine J 12:265\u2013272. https:\/\/doi.org\/10.1016\/j.spinee.2012.02.002","journal-title":"Spine J"},{"key":"6673_CR13","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1016\/j.spinee.2016.05.017","volume":"16","author":"BJ Yoon","year":"2016","unstructured":"Yoon BJ, Xavier F, Walker BR, Grinberg S, Cammisa FP, Abjornson C (2016) Optimizing surface characteristics for cell adhesion and proliferation on titanium plasma spray coatings on polyetheretherketone. Spine J 16:1238\u20131243. https:\/\/doi.org\/10.1016\/j.spinee.2016.05.017","journal-title":"Spine J"},{"key":"6673_CR14","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1111\/os.12098","volume":"6","author":"PJ Rao","year":"2014","unstructured":"Rao PJ, Pelletier MH, Walsh WR, Mobbs RJ (2014) Spine interbody implants: material selection and modification, functionalization and bioactivation of surfaces to improve osseointegration. Orthop Surg 6:81\u201389. https:\/\/doi.org\/10.1111\/os.12098","journal-title":"Orthop Surg"},{"key":"6673_CR15","doi-asserted-by":"publisher","first-page":"77","DOI":"10.3389\/fbioe.2017.00077","volume":"5","author":"D Tang","year":"2017","unstructured":"Tang D, Yang LY, Ou KL, Oreffo ROC (2017) Repositioning titanium: an in vitro evaluation of laser-generated microporous, microrough titanium templates as a potential bridging interface for enhanced osseointegration and durability of implants. Front Bioeng Biotechnol 5:77. https:\/\/doi.org\/10.3389\/fbioe.2017.00077","journal-title":"Front Bioeng Biotechnol"},{"key":"6673_CR16","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.spinee.2015.09.038","volume":"16","author":"A Kienle","year":"2016","unstructured":"Kienle A, Graf N, Wilke HJ (2016) Does impaction of titanium-coated interbody fusion cages into the disc space cause wear debris or delamination? Spine J 16:235\u2013242. https:\/\/doi.org\/10.1016\/j.spinee.2015.09.038","journal-title":"Spine J"},{"key":"6673_CR17","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1016\/j.spinee.2018.01.003","volume":"18","author":"FB Torstrick","year":"2018","unstructured":"Torstrick FB, Klosterhoff BS, Westerlund LE, Foley KT, Gochuico J, Lee CSD, Gall K, Safranski DL (2018) Impaction durability of porous polyether-ether-ketone (PEEK) and titanium-coated PEEK interbody fusion devices. Spine J 18:857\u2013865. https:\/\/doi.org\/10.1016\/j.spinee.2018.01.003","journal-title":"Spine J"},{"key":"6673_CR18","doi-asserted-by":"publisher","first-page":"2963","DOI":"10.3389\/fimmu.2018.02963","volume":"9","author":"M Eger","year":"2018","unstructured":"Eger M, Hiram-Bab S, Liron T, Sterer N, Carmi Y, Kohavi D, Gabet Y (2018) Mechanism and prevention of titanium particle-induced inflammation and osteolysis. Front Immunol 9:2963. https:\/\/doi.org\/10.3389\/fimmu.2018.02963","journal-title":"Front Immunol"},{"key":"6673_CR19","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1097\/RCT.0b013e3181568b27","volume":"32","author":"SG Moon","year":"2008","unstructured":"Moon SG, Hong SH, Choi JY, Jun WS, Kang HG, Kim HS, Kang HS (2008) Metal artifact reduction by the alteration of technical factors in multidetector computed tomography: a 3-dimensional quantitative assessment. J Comput Assist Tomogr 32:630\u2013633. https:\/\/doi.org\/10.1097\/RCT.0b013e3181568b27","journal-title":"J Comput Assist Tomogr"},{"key":"6673_CR20","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.ejrad.2018.08.010","volume":"107","author":"RHH Wellenberg","year":"2018","unstructured":"Wellenberg RHH, Hakvoort ET, Slump CH, Boomsma MF, Maas M, Streekstra GJ (2018) Metal artifact reduction techniques in musculoskeletal CT-imaging. Eur J Radiol 107:60\u201369. https:\/\/doi.org\/10.1016\/j.ejrad.2018.08.010","journal-title":"Eur J Radiol"},{"key":"6673_CR21","doi-asserted-by":"publisher","first-page":"1553","DOI":"10.1016\/s0021-9290(02)00187-2","volume":"35","author":"M Lengsfeld","year":"2002","unstructured":"Lengsfeld M, Gunther D, Pressel T, Leppek R, Schmitt J, Griss P (2002) Validation data for periprosthetic bone remodelling theories. J Biomech 35:1553\u20131564. https:\/\/doi.org\/10.1016\/s0021-9290(02)00187-2","journal-title":"J Biomech"},{"key":"6673_CR22","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1097\/01.rct.0000250117.18080.d8","volume":"31","author":"IS Lee","year":"2007","unstructured":"Lee IS, Kim HJ, Choi BK, Jeong YJ, Lee TH, Moon TY, Won Kang D (2007) A pragmatic protocol for reduction in the metal artifact and radiation dose in multislice computed tomography of the spine: cadaveric evaluation after cervical pedicle screw placement. J Comput Assist Tomogr 31:635\u2013641. https:\/\/doi.org\/10.1097\/01.rct.0000250117.18080.d8","journal-title":"J Comput Assist Tomogr"},{"key":"6673_CR23","doi-asserted-by":"publisher","unstructured":"Ito K, Horiuchi T, Arai Y, Kawahara I, Hongo K (2014) Histological, mechanical, and radiological study of osteoformation in titanium foam implants. Acta Neurochir, 156: 2165\u20132172. Discussion 2172. https:\/\/doi.org\/10.1007\/s00701-014-2122-9","DOI":"10.1007\/s00701-014-2122-9"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-020-06673-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-020-06673-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-020-06673-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,24]],"date-time":"2021-05-24T15:11:52Z","timestamp":1621869112000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-020-06673-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,3]]},"references-count":23,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021,5]]}},"alternative-id":["6673"],"URL":"https:\/\/doi.org\/10.1007\/s00586-020-06673-4","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,3]]},"assertion":[{"value":"16 June 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 November 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 November 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 January 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}},{"value":"All procedures performed were in accordance with the HELSINKI declaration 1964. This research has been approved by the IRB of the authors\u2019 affiliated institutions.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The research protocol was approved and publicized by the authors\u2019 affiliated institution, and the patients were given the right to opt out of the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}