{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T00:56:02Z","timestamp":1775868962213,"version":"3.50.1"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2021,3,26]],"date-time":"2021-03-26T00:00:00Z","timestamp":1616716800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,3,26]],"date-time":"2021-03-26T00:00:00Z","timestamp":1616716800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2021,10]]},"DOI":"10.1007\/s00586-021-06819-y","type":"journal-article","created":{"date-parts":[[2021,3,26]],"date-time":"2021-03-26T18:02:27Z","timestamp":1616781747000},"page":"2852-2856","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Percutaneous wide bore needle biopsy for spinal lesions using the kyphoplasty cannula\u2014a technical note"],"prefix":"10.1007","volume":"30","author":[{"given":"Saumyajit","family":"Basu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7807-0242","authenticated-orcid":false,"given":"Rohan B.","family":"Gala","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anil M.","family":"Solanki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,3,26]]},"reference":[{"key":"6819_CR1","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1038\/sc.2008.108","volume":"47","author":"BR Dave","year":"2009","unstructured":"Dave BR, Nanda A, Anandjiwala JV (2009) Transpedicular percutaneous biopsy of vertebral body lesions: a series of 71 cases. Spinal Cord 47:384\u2013389","journal-title":"Spinal Cord"},{"key":"6819_CR2","doi-asserted-by":"publisher","first-page":"1985","DOI":"10.1097\/00007632-199409000-00021","volume":"19","author":"DR Stringham","year":"1994","unstructured":"Stringham DR, Hadjipavlou A, Dzioba RB et al (1994) Percutaneous transpedicular biopsy of the spine. Spine (Phila Pa 1976) 19:1985\u20131991","journal-title":"Spine (Phila Pa 1976)"},{"key":"6819_CR3","doi-asserted-by":"publisher","first-page":"813","DOI":"10.2214\/ajr.158.4.1546598","volume":"158","author":"MA Fraser-Hill","year":"1992","unstructured":"Fraser-Hill MA, Renfrew DL, Hilsenrath PE (1992) Percutaneous needle biopsy of musculoskeletal lesions. 2. Cost-effectiveness. AJR Am J Roentgenol 158:813\u2013818","journal-title":"Cost-effectiveness. AJR Am J Roentgenol"},{"key":"6819_CR4","first-page":"477","volume":"28","author":"VB Shidham","year":"1984","unstructured":"Shidham VB, Dravid NV, Kher AV (1984) Role of scrape cytology in intraoperative diagnosis values and limitations. Acta Cytol 28:477\u2013482","journal-title":"Acta Cytol"},{"key":"6819_CR5","doi-asserted-by":"publisher","first-page":"759","DOI":"10.2214\/ajr.171.3.ajronline_171_3_001","volume":"171","author":"DE Dupuy","year":"1998","unstructured":"Dupuy DE, Rosenberg AE, Punyaratabandhu T (1998) Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms. Am J Roentgenol 171:759\u2013762","journal-title":"Am J Roentgenol"},{"key":"6819_CR6","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.2106\/00004623-198264080-00002","volume":"64","author":"HJ Mankin","year":"1982","unstructured":"Mankin HJ, Lange TA, Spanier SS (1982) The hazards of biopsy in patients with malignant primary bone and soft-tissue tumors. J Bone Joint Surg Am 64:1121\u20131127","journal-title":"J Bone Joint Surg Am"},{"issue":"7","key":"6819_CR7","doi-asserted-by":"publisher","first-page":"759","DOI":"10.5858\/2004-128-759-CONCBA","volume":"128","author":"YJ Yang","year":"2004","unstructured":"Yang YJ, Damron TA (2004) Comparison of needle core biopsy and fine needle aspiration for diagnostic accuracy in musculoskeletal lesions. Arch of Pathol Lab Med 128(7):759\u2013764","journal-title":"Arch of Pathol Lab Med"},{"key":"6819_CR8","first-page":"351","volume":"18","author":"P Brugieres","year":"1991","unstructured":"Brugieres P, Revel MP, Dumas JL et al (1991) CT-guided vertebral biopsy: a report of 89 cases. J Neuroradiol 18:351\u2013359","journal-title":"J Neuroradiol"},{"key":"6819_CR9","doi-asserted-by":"publisher","first-page":"1722","DOI":"10.2106\/JBJS.G.00646","volume":"90","author":"A Nourbakhsh","year":"2008","unstructured":"Nourbakhsh A, Grady JJ, Garges KJ (2008) Percutaneous spine biopsy: a meta-analysis. J Bone Joint Surg Am 90:1722\u20131725","journal-title":"J Bone Joint Surg Am"},{"key":"6819_CR10","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1097\/00007632-199801010-00018","volume":"23","author":"MB Kornblum","year":"1998","unstructured":"Kornblum MB, Wesolowski DP, Fischgrund JS et al (1998) Computed tomography guided biopsy of the spine. Spine 23:81\u201385","journal-title":"Spine"},{"issue":"7","key":"6819_CR11","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1007\/s00586-008-0678-x","volume":"17","author":"E Rimondi","year":"2008","unstructured":"Rimondi E, Staals EL, Errani C (2008) Percutaneous CT-guided biopsy of the spine: results of 430 biopsies. Eur Spine J 17(7):975\u2013981","journal-title":"Eur Spine J"},{"issue":"1","key":"6819_CR12","doi-asserted-by":"publisher","first-page":"5","DOI":"10.5005\/jp-journals-10028-1135","volume":"49","author":"S Basu","year":"2015","unstructured":"Basu S, Tikoo A, Malik FH et al (2015) Percutaneous C-arm-guided wide bore needle biopsy for intraosseous spinal lesions. J Postgrad Med Edu Res 49(1):5\u20139","journal-title":"J Postgrad Med Edu Res"},{"key":"6819_CR13","doi-asserted-by":"publisher","first-page":"2320","DOI":"10.1016\/j.spinee.2014.01.033","volume":"14","author":"J Naresh-Babu","year":"2014","unstructured":"Naresh-Babu J, Neelima G, Reshma-Begum SK (2014) Increasing the specimen adequacy of transpedicular vertebral body biopsies. Role of intraoperative scrape cytology. Spine J 14:2320\u20132325","journal-title":"Spine J"},{"issue":"4","key":"6819_CR14","doi-asserted-by":"publisher","first-page":"427","DOI":"10.4103\/0019-5413.98831","volume":"46","author":"S Basu","year":"2012","unstructured":"Basu S, Ghosh JD, Malik FH et al (2012) Postoperative discitis following single-level lumbar discectomy: Our experience of 17 cases. Indian J Orthop 46(4):427\u2013433","journal-title":"Indian J Orthop"},{"issue":"S1","key":"6819_CR15","doi-asserted-by":"publisher","first-page":"16","DOI":"10.4103\/joas.joas_57_17","volume":"6","author":"A Krishnan","year":"2018","unstructured":"Krishnan A, Barot MP, Dave BR et al (2018) Percutaneous transforaminal endoscopic discectomy and drainage for spondylodiscitis: A technical note and review of literature. J Orthop Allied Sci 6(S1):16\u201320","journal-title":"J Orthop Allied Sci"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-021-06819-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-021-06819-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-021-06819-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,24]],"date-time":"2021-09-24T02:29:23Z","timestamp":1632450563000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-021-06819-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,26]]},"references-count":15,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["6819"],"URL":"https:\/\/doi.org\/10.1007\/s00586-021-06819-y","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,26]]},"assertion":[{"value":"30 June 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 March 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 March 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declaration"}},{"value":"The authors declare that there is no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}