{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T12:41:11Z","timestamp":1790685671388,"version":"4.1.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2022,10,15]],"date-time":"2022-10-15T00:00:00Z","timestamp":1665792000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,10,15]],"date-time":"2022-10-15T00:00:00Z","timestamp":1665792000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Knowledge about spinal length and subsequently growth of each individual patient with adolescent idiopathic scoliosis (AIS) helps with accurate timing of both conservative and surgical treatment. Radiographs taken by a biplanar low-dose X-ray device (EOS) have no divergence in the vertical plane and can provide three-dimensional (3D) measurements. Therefore, this study investigated the criterion validity and reliability of EOS spinal length measurements in AIS patients.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Prior to routine EOS radiograph, a radiographic calibrated metal beads chain (MBC) was attached on the back of 120 patients with AIS to calibrate the images. Spinal lengths were measured from vertebra to vertebra on EOS anteroposterior (AP), lateral view and on the combined 3D EOS view (EOS 3D). These measurements were compared with MBC length measurements. Secondly, intra- and interobserver reliability of length measurements on EOS-images were determined.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>50 patients with accurately positioned MBC were included for analysis. The correlations between EOS and MBC were highest for the 3D length measurements. Compared to EOS 3D measurements, the total spinal length was systematically measured 4.3% (mean difference\u2009=\u20091.97\u2009\u00b1\u20091.12\u00a0cm) and 1.9% (mean difference\u2009=\u20090.86\u2009\u00b1\u20090.63\u00a0cm) smaller on individual EOS two-dimensional (2D) AP and lateral view images, respectively. Both intra- and interobserver reliability were excellent for all length measurements on EOS-images.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The results of this study indicate a good validity and reliability for spinal length measurements on EOS radiographs in AIS patients. EOS 3D length measure method is preferred above spinal length measurements on individual EOS AP or lateral view images.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00586-022-07326-4","type":"journal-article","created":{"date-parts":[[2022,10,15]],"date-time":"2022-10-15T07:02:32Z","timestamp":1665817352000},"page":"3527-3535","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Assessment of spine length in scoliosis patients using EOS imaging: a validity and reliability study"],"prefix":"10.1007","volume":"31","author":[{"given":"C. M. M.","family":"Peeters","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. J. F. J.","family":"Bos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D. H. R.","family":"Kempen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. C.","family":"Jutte","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Faber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F. H.","family":"Wapstra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,10,15]]},"reference":[{"issue":"16","key":"7326_CR1","doi-asserted-by":"publisher","first-page":"1512","DOI":"10.1056\/NEJMoa1307337","volume":"369","author":"SL Weinstein","year":"2013","unstructured":"Weinstein SL, Dolan LA, Wright JG et al (2013) Effects of bracing in adolescents with idiopathic scoliosis. N Engl J Med 369(16):1512\u20131521. https:\/\/doi.org\/10.1056\/NEJMoa1307337","journal-title":"N Engl J Med"},{"key":"7326_CR2","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1186\/1748-7161-7-3","volume":"7","author":"S Negrini","year":"2012","unstructured":"Negrini S, Aulisa AG, Aulisa L et al (2012) 2011 SOSORT guidelines: orthopaedic and rehabilitation treatment of idiopathic scoliosis during growth. Scoliosis 7:3. https:\/\/doi.org\/10.1186\/1748-7161-7-3","journal-title":"Scoliosis"},{"key":"7326_CR3","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1186\/1471-2474-11-93","volume":"11","author":"I Busscher","year":"2010","unstructured":"Busscher I, Wapstra FH, Veldhuizen AG (2010) Predicting growth and curve progression in the individual patient with adolescent idiopathic scoliosis: design of a prospective longitudinal cohort study. BMC Musculoskelet Disord 11:93. https:\/\/doi.org\/10.1186\/1471-2474-11-93","journal-title":"BMC Musculoskelet Disord"},{"key":"7326_CR4","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1007\/s00586-010-1584-6","volume":"20","author":"I Busscher","year":"2011","unstructured":"Busscher I, Gerver WJ, Kingma I et al (2011) The growth of different body length dimensions is not predictive for the peak growth velocity of sitting height in the individual child. Eur Spine J 20:791\u2013797. https:\/\/doi.org\/10.1007\/s00586-010-1584-6","journal-title":"Eur Spine J"},{"key":"7326_CR5","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1186\/s12891-016-1221-6","volume":"17","author":"B Shi","year":"2016","unstructured":"Shi B, Mao S, Liu Z et al (2016) Spinal growth velocity versus height velocity in predicting curve progression in peri-pubertal girls with idiopathic scoliosis. BMC Musculoskelet Disord 17:368. https:\/\/doi.org\/10.1186\/s12891-016-1221-6","journal-title":"BMC Musculoskelet Disord"},{"key":"7326_CR6","doi-asserted-by":"publisher","unstructured":"Heemskerk JL, Wijdicks SPJ, Altena MC et al. (2020) Spinal growth in patients with juvenile idiopathic scoliosis treated with boston brace: a retrospective study. Spine (Phila Pa 1976) 45:976\u2013982. https:\/\/doi.org\/10.1097\/BRS.0000000000003435","DOI":"10.1097\/BRS.0000000000003435"},{"key":"7326_CR7","doi-asserted-by":"publisher","first-page":"3366","DOI":"10.1007\/s00586-016-4747-2","volume":"25","author":"A Simony","year":"2016","unstructured":"Simony A, Hansen EJ, Christensen SB et al (2016) Incidence of cancer in adolescent idiopathic scoliosis patients treated 25 years previously. Eur Spine J 25:3366\u20133370. https:\/\/doi.org\/10.1007\/s00586-016-4747-2","journal-title":"Eur Spine J"},{"key":"7326_CR8","doi-asserted-by":"publisher","first-page":"1052","DOI":"10.1016\/j.spinee.2012.10.002","volume":"12","author":"S Somoskeoy","year":"2012","unstructured":"Somoskeoy S, Tunyogi-Csapo M, Bogyo C et al (2012) Accuracy and reliability of coronal and sagittal spinal curvature data based on patient-specific three-dimensional models created by the EOS 2D\/3D imaging system. Spine J 12:1052\u20131059. https:\/\/doi.org\/10.1016\/j.spinee.2012.10.002","journal-title":"Spine J"},{"key":"7326_CR9","doi-asserted-by":"publisher","first-page":"1362","DOI":"10.1007\/s00586-013-2752-2","volume":"22","author":"C Vidal","year":"2013","unstructured":"Vidal C, Ilharreborde B, Azoulay R et al (2013) Reliability of cervical lordosis and global sagittal spinal balance measurements in adolescent idiopathic scoliosis. Eur Spine J 22:1362\u20131367. https:\/\/doi.org\/10.1007\/s00586-013-2752-2","journal-title":"Eur Spine J"},{"key":"7326_CR10","doi-asserted-by":"publisher","first-page":"2894","DOI":"10.1007\/s00167-016-4031-3","volume":"25","author":"MF Meijer","year":"2017","unstructured":"Meijer MF, Boerboom AL, Bulstra SK et al (2017) Do CAS measurements correlate with EOS 3D alignment measurements in primary TKA? Knee Surg Sports Traumatol Arthrosc 25:2894\u20132903. https:\/\/doi.org\/10.1007\/s00167-016-4031-3","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"7326_CR11","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-021-06839-8","author":"CMM Peeters","year":"2021","unstructured":"Peeters CMM, van Houten L, Kempen DHR et al (2021) Assessment of pedicle size in patients with scoliosis using EOS 2D imaging: a validity and reliability study. Eur Spine J. https:\/\/doi.org\/10.1007\/s00586-021-06839-8","journal-title":"Eur Spine J"},{"key":"7326_CR12","unstructured":"Domholdt E (2000) Physical therapy research In: Principles and applications. WB Saunders, Philadelphia."},{"key":"7326_CR13","doi-asserted-by":"crossref","unstructured":"Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307\u2013310. S0140-6736(86)90837-8","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"7326_CR14","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1191\/026921598672178340","volume":"12","author":"G Rankin","year":"1998","unstructured":"Rankin G, Stokes M (1998) Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses. Clin Rehabil 12:187\u2013199. https:\/\/doi.org\/10.1191\/026921598672178340","journal-title":"Clin Rehabil"},{"key":"7326_CR15","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15:155\u2013163. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012","journal-title":"J Chiropr Med"},{"key":"7326_CR16","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0104613","volume":"9","author":"MF Meijer","year":"2014","unstructured":"Meijer MF, Boerboom AL, Stevens M et al (2014) Assessment of prosthesis alignment after revision total knee arthroplasty using EOS 2D and 3D imaging: a reliability study. PLoS ONE 9:e104613. https:\/\/doi.org\/10.1371\/journal.pone.0104613","journal-title":"PLoS ONE"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-022-07326-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-022-07326-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-022-07326-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,9]],"date-time":"2022-12-09T13:25:27Z","timestamp":1670592327000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-022-07326-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,15]]},"references-count":16,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["7326"],"URL":"https:\/\/doi.org\/10.1007\/s00586-022-07326-4","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,15]]},"assertion":[{"value":"25 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 March 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 July 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 October 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no relevant financial or non-financial interests to disclose. The authors have no conflicts of interest to declare that are relevant to the content of this article. All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest or non-financial interest in the subject matter or materials discussed in this manuscript. The authors have no financial or proprietary interests in any material discussed in this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All authors have made direct contributions to the intellectual content of the paper and have approved the final version of the paper. The material in this paper has not been previously published or submitted elsewhere for publication. Each author believes that the manuscript represents honest work. All authors have nothing to disclose. This study was approved by the Medical Ethical Review Board (RR-number: 201800763). The Manuscript submitted does not contain information about medical device(s)\/drug(s).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}