{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T13:58:18Z","timestamp":1793195898171,"version":"4.5.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2022,8,6]],"date-time":"2022-08-06T00:00:00Z","timestamp":1659744000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,8,6]],"date-time":"2022-08-06T00:00:00Z","timestamp":1659744000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"CDMI\/NSF"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2022,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Multi-rod constructs are used commonly to stabilize pedicle subtraction osteotomies (PSO). This study aimed to evaluate biomechanical properties of different satellite rod configurations and effects of screw-type spanning a PSO.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A validated 3D spinopelvic finite element model with a L3 PSO (30\u00b0) was used to evaluate 5 models: (1) Control (T10\u2013pelvis\u2009+\u20092 rods); (2) lateral satellite rods connected via offsets to monoaxial screws (LatSat-Mono) or (3) polyaxial screws (LatSat-Poly); (4) in-line satellite rods connected to monoaxial screws (InSat-Mono) or (4) polyaxial screws (InSat-Poly). Global and PSO range of motions (ROM) were recorded. Rods\u2019 von Mises stresses and PSO forces were recorded and the percent differences from Control were calculated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>All satellite rods (save InSat-Mono) increased PSO ROM and decreased primary rods\u2019 von Mises stresses at the PSO. Lateral rods increased PSO forces (LatSat-Mono:347.1\u00a0N; LatSat-Poly:348.6\u00a0N; Control:336\u00a0N) and had relatively lower stresses, while in-line rods decreased PSO forces (InSat-Mono:280.1\u00a0N; InSat-Poly:330.7\u00a0N) and had relatively higher stresses. Relative to polyaxial screws, monoaxial screws further decreased PSO ROM, increased satellite rods\u2019 stresses, and decreased PSO forces for in-line rods, but did not change PSO forces for lateral rods.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Multi-rod constructs using in-line and lateral satellite rods across a PSO reduced primary rods' stresses. Subtle differences in biomechanics suggest lateral satellite rods, irrespective of screw type, increase PSO forces and lower rod stresses compared to in-line satellite rods, which had a high degree of posterior instrumentation stress shielding and lower PSO forces. Clinical studies are warranted to determine if these findings influence clinical outcomes.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00586-022-07331-7","type":"journal-article","created":{"date-parts":[[2022,8,6]],"date-time":"2022-08-06T14:02:48Z","timestamp":1659794568000},"page":"3050-3059","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Biomechanical comparison of multi-rod constructs by satellite rod configurations (in-line vs. lateral) and screw types (monoaxial vs. polyaxial) spanning a lumbar pedicle subtraction osteotomy (PSO): is there an optimal configuration?"],"prefix":"10.1007","volume":"31","author":[{"given":"Niloufar","family":"Shekouhi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ardalan S.","family":"Vosoughi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph M.","family":"Zavatsky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vijay K.","family":"Goel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alekos A.","family":"Theologis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,8,6]]},"reference":[{"key":"7331_CR1","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1055\/s-0035-1570088","volume":"6","author":"MD Daubs","year":"2016","unstructured":"Daubs MD, Brodke DS, Annis P, Lawrence BD (2016) Perioperative complications of pedicle subtraction osteotomy. Glob Spine J 6:630\u2013635","journal-title":"Glob Spine J"},{"key":"7331_CR2","first-page":"S67","volume":"16","author":"P Annis","year":"2016","unstructured":"Annis P, Dheerendra S, Daubs M, Brodke D (2016) Perioperative complications of pedicle subtraction osteotomy. Spine J 16:S67","journal-title":"Spine J"},{"key":"7331_CR3","doi-asserted-by":"publisher","first-page":"444","DOI":"10.3171\/2016.10.SPINE16849","volume":"27","author":"JS Smith","year":"2017","unstructured":"Smith JS, Shaffrey CI, Klineberg E, Lafage V, Schwab F, Lafage R, Kim HJ, Hostin R, Mundis GM, Gupta M (2017) Complication rates associated with 3-column osteotomy in 82 adult spinal deformity patients: retrospective review of a prospectively collected multicenter consecutive series with 2-year follow-up. J Neurosurg Spine 27:444\u2013457","journal-title":"J Neurosurg Spine"},{"key":"7331_CR4","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1093\/ons\/opx151","volume":"14","author":"S Gupta","year":"2018","unstructured":"Gupta S, Eksi MS, Ames CP, Deviren V, Durbin-Johnson B, Smith JS, Gupta MC (2018) A novel 4-rod technique offers potential to reduce rod breakage and pseudarthrosis in pedicle subtraction osteotomies for adult spinal deformity correction. Oper Neurosurg (Hagerstown) 14:449\u2013456. https:\/\/doi.org\/10.1093\/ons\/opx151","journal-title":"Oper Neurosurg (Hagerstown)"},{"key":"7331_CR5","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1227\/NEU.0b013e3182672aab","volume":"71","author":"JS Smith","year":"2012","unstructured":"Smith JS, Shaffrey CI, Ames CP, Demakakos J, Fu K-MG, Keshavarzi S, Li CM, Deviren V, Schwab FJ, Lafage V (2012) Assessment of symptomatic rod fracture after posterior instrumented fusion for adult spinal deformity. Neurosurgery 71:862\u2013868","journal-title":"Neurosurgery"},{"key":"7331_CR6","doi-asserted-by":"publisher","first-page":"994","DOI":"10.3171\/2014.9.SPINE131176","volume":"21","author":"JS Smith","year":"2014","unstructured":"Smith JS, Shaffrey E, Klineberg E, Shaffrey CI, Lafage V, Schwab FJ, Protopsaltis T, Scheer JK, Mundis GM, Fu K-MG (2014) Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity. J Neurosurg Spine 21:994\u20131003","journal-title":"J Neurosurg Spine"},{"key":"7331_CR7","doi-asserted-by":"publisher","first-page":"567","DOI":"10.3340\/jkns.2018.0191","volume":"62","author":"YC Kim","year":"2019","unstructured":"Kim YC, Kim KT, Kim CK, Hwang IY, Jin WY, Lenke LG, Cha JR (2019) Outcomes of non-operative management for Pseudarthrosis after pedicle subtraction osteotomies at minimum 5 years follow-up. J Korean Neurosurg Soc 62:567\u2013576. https:\/\/doi.org\/10.3340\/jkns.2018.0191","journal-title":"J Korean Neurosurg Soc"},{"key":"7331_CR8","doi-asserted-by":"publisher","first-page":"2189","DOI":"10.1097\/BRS.0b013e31814b8371","volume":"32","author":"YJ Kim","year":"2007","unstructured":"Kim YJ, Bridwell KH, Lenke LG, Cheh G, Baldus C (2007) Results of lumbar pedicle subtraction osteotomies for fixed sagittal imbalance: a minimum 5-year follow-up study. Spine 32:2189\u20132197","journal-title":"Spine"},{"key":"7331_CR9","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1007\/s00586-014-3555-9","volume":"23","author":"A Luca","year":"2014","unstructured":"Luca A, Lovi A, Galbusera F, Brayda-Bruno M (2014) Revision surgery after PSO failure with rod breakage: a comparison of different techniques. Eur Spine J 23:610\u2013615","journal-title":"Eur Spine J"},{"key":"7331_CR10","doi-asserted-by":"publisher","first-page":"1899","DOI":"10.1097\/brs.0000000000000556","volume":"39","author":"SJ Hyun","year":"2014","unstructured":"Hyun SJ, Lenke LG, Kim YC, Koester LA, Blanke KM (2014) Comparison of standard 2-rod constructs to multiple-rod constructs for fixation across 3-column spinal osteotomies. Spine (Phila Pa 1976) 39:1899\u20131904. https:\/\/doi.org\/10.1097\/brs.0000000000000556","journal-title":"Spine (Phila Pa 1976)"},{"key":"7331_CR11","doi-asserted-by":"publisher","first-page":"3595","DOI":"10.1038\/s41598-021-83251-8","volume":"11","author":"L La Barbera","year":"2021","unstructured":"La Barbera L, Wilke HJ, Ruspi ML, Palanca M, Liebsch C, Luca A, Brayda-Bruno M, Galbusera F, Cristofolini L (2021) Load-sharing biomechanics of lumbar fixation and fusion with pedicle subtraction osteotomy. Sci Rep 11:3595. https:\/\/doi.org\/10.1038\/s41598-021-83251-8","journal-title":"Sci Rep"},{"key":"7331_CR12","doi-asserted-by":"publisher","first-page":"764","DOI":"10.1007\/s00586-016-4859-8","volume":"26","author":"A Luca","year":"2017","unstructured":"Luca A, Ottardi C, Sasso M, Prosdocimo L, La Barbera L, Brayda-Bruno M, Galbusera F, Villa T (2017) Instrumentation failure following pedicle subtraction osteotomy: the role of rod material, diameter, and multi-rod constructs. Eur Spine J 26:764\u2013770. https:\/\/doi.org\/10.1007\/s00586-016-4859-8","journal-title":"Eur Spine J"},{"key":"7331_CR13","doi-asserted-by":"publisher","first-page":"E388","DOI":"10.1097\/brs.0000000000001282","volume":"41","author":"DW Hallager","year":"2016","unstructured":"Hallager DW, Gehrchen M, Dahl B, Harris JA, Gudipally M, Jenkins S, Wu AM, Bucklen BS (2016) Use of supplemental short pre-contoured accessory rods and cobalt chrome alloy posterior rods reduces primary rod strain and range of motion across the pedicle subtraction osteotomy level: an in vitro biomechanical study. Spine (Phila Pa 1976) 41:E388-395. https:\/\/doi.org\/10.1097\/brs.0000000000001282","journal-title":"Spine (Phila Pa 1976)"},{"key":"7331_CR14","doi-asserted-by":"publisher","first-page":"2357","DOI":"10.1007\/s00586-018-5623-z","volume":"27","author":"L La Barbera","year":"2018","unstructured":"La Barbera L, Brayda-Bruno M, Liebsch C, Villa T, Luca A, Galbusera F, Wilke HJ (2018) Biomechanical advantages of supplemental accessory and satellite rods with and without interbody cages implantation for the stabilization of pedicle subtraction osteotomy. Eur Spine J 27:2357\u20132366. https:\/\/doi.org\/10.1007\/s00586-018-5623-z","journal-title":"Eur Spine J"},{"key":"7331_CR15","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1016\/j.spinee.2018.11.003","volume":"19","author":"A Seyed Vosoughi","year":"2019","unstructured":"Seyed Vosoughi A, Joukar A, Kiapour A, Parajuli D, Agarwal AK, Goel VK, Zavatsky J (2019) Optimal satellite rod constructs to mitigate rod failure following pedicle subtraction osteotomy (PSO): a finite element study. Spine J 19:931\u2013941. https:\/\/doi.org\/10.1016\/j.spinee.2018.11.003","journal-title":"Spine J"},{"key":"7331_CR16","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1055\/s-0032-1331460","volume":"2","author":"V Deviren","year":"2012","unstructured":"Deviren V, Tang JA, Scheer JK, Buckley JM, Pekmezci M, McClellan RT, Ames CP (2012) Construct Rigidity after Fatigue Loading in Pedicle Subtraction Osteotomy with or without Adjacent Interbody Structural Cages. Global Spine J 2:213\u2013220. https:\/\/doi.org\/10.1055\/s-0032-1331460","journal-title":"Global Spine J"},{"key":"7331_CR17","doi-asserted-by":"publisher","first-page":"E12","DOI":"10.1097\/brs.0000000000003720","volume":"46","author":"E Jazini","year":"2021","unstructured":"Jazini E, Gelb DE, Tareen J, Ludwig SC, Harris JA, Amin DB, Wang W, Van Horn MR, Patel PD, Mirabile BA, Bucklen BS (2021) Comprehensive in silico evaluation of accessory rod position, rod material and diameter, use of cross-connectors, and anterior column support in a pedicle subtraction osteotomy model: part II: effects on lumbosacral rod and screw strain. Spine (Phila Pa 1976) 46:E12\u2013E22. https:\/\/doi.org\/10.1097\/brs.0000000000003720","journal-title":"Spine (Phila Pa 1976)"},{"key":"7331_CR18","doi-asserted-by":"publisher","first-page":"103","DOI":"10.3171\/2020.6.SPINE20678","volume":"34","author":"MH El Dafrawy","year":"2020","unstructured":"El Dafrawy MH, Adogwa O, Wegner AM, Pallotta NA, Kelly MP, Kebaish KM, Bridwell KH, Gupta MC (2020) Comprehensive classification system for multirod constructs across three-column osteotomies: a reliability study. J Neurosurg Spine 34:103\u2013109","journal-title":"J Neurosurg Spine"},{"key":"7331_CR19","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1097\/00007632-200101150-00019","volume":"26","author":"WT Edwards","year":"2001","unstructured":"Edwards WT, Zheng Y, Ferrara LA, Yuan HA (2001) Structural features and thickness of the vertebral cortex in the thoracolumbar spine. Spine 26:218\u2013225","journal-title":"Spine"},{"key":"7331_CR20","doi-asserted-by":"publisher","first-page":"69","DOI":"10.3389\/fbioe.2015.00069","volume":"3","author":"N Momeni Shahraki","year":"2015","unstructured":"Momeni Shahraki N, Fatemi A, Goel VK, Agarwal A (2015) On the use of biaxial properties in modeling annulus as a Holzapfel\u2013Gasser\u2013Ogden material. Front Bioeng Biotechnol 3:69","journal-title":"Front Bioeng Biotechnol"},{"key":"7331_CR21","doi-asserted-by":"publisher","first-page":"64","DOI":"10.14444\/2064","volume":"9","author":"DP Lindsey","year":"2015","unstructured":"Lindsey DP, Kiapour A, Yerby SA, Goel VK (2015) Sacroiliac joint fusion minimally affects adjacent lumbar segment motion: a finite element study. Int J Spine Surg 9:64","journal-title":"Int J Spine Surg"},{"key":"7331_CR22","doi-asserted-by":"publisher","first-page":"609","DOI":"10.6061\/clinics\/2017(10)04","volume":"72","author":"H Wang","year":"2017","unstructured":"Wang H, Zhao Y, Mo Z, Han J, Chen Y, Yu H, Wang Q, Liu J, Li C, Zhou Y (2017) Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review. Clinics 72:609\u2013617","journal-title":"Clinics"},{"key":"7331_CR23","doi-asserted-by":"publisher","first-page":"2749","DOI":"10.3390\/ma8052749","volume":"8","author":"MA Hussein","year":"2015","unstructured":"Hussein MA, Mohammed AS, Al-Aqeeli N (2015) Wear characteristics of metallic biomaterials: a review. Materials 8:2749\u20132768","journal-title":"Materials"},{"key":"7331_CR24","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1007\/s00586-017-5084-9","volume":"26","author":"A Luca","year":"2017","unstructured":"Luca A, Ottardi C, Lovi A, Brayda-Bruno M, Villa T, Galbusera F (2017) Anterior support reduces the stresses on the posterior instrumentation after pedicle subtraction osteotomy: a finite-element study. Eur Spine J 26:450\u2013456. https:\/\/doi.org\/10.1007\/s00586-017-5084-9","journal-title":"Eur Spine J"},{"key":"7331_CR25","doi-asserted-by":"publisher","first-page":"2198","DOI":"10.1007\/s00586-019-06012-2","volume":"28","author":"P Berjano","year":"2019","unstructured":"Berjano P, Xu M, Damilano M, Scholl T, Lamartina C, Jekir M, Galbusera F (2019) Supplementary delta-rod configurations provide superior stiffness and reduced rod stress compared to traditional multiple-rod configurations after pedicle subtraction osteotomy: a finite element study. Eur Spine J 28:2198\u20132207. https:\/\/doi.org\/10.1007\/s00586-019-06012-2","journal-title":"Eur Spine J"},{"key":"7331_CR26","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1227\/NEU.0b013e31820f362a","volume":"69","author":"JK Scheer","year":"2011","unstructured":"Scheer JK, Tang JA, Deviren V, Buckley JM, Pekmezci M, McClellan RT, Ames CP (2011) Biomechanical analysis of revision strategies for rod fracture in pedicle subtraction osteotomy. Neurosurgery 69:164\u2013172","journal-title":"Neurosurgery"},{"key":"7331_CR27","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1007\/s00586-019-06087-x","volume":"29","author":"L La Barbera","year":"2020","unstructured":"La Barbera L, Wilke HJ, Liebsch C, Villa T, Luca A, Galbusera F, Brayda-Bruno M (2020) Biomechanical in vitro comparison between anterior column realignment and pedicle subtraction osteotomy for severe sagittal imbalance correction. Eur Spine J 29:36\u201344. https:\/\/doi.org\/10.1007\/s00586-019-06087-x","journal-title":"Eur Spine J"},{"key":"7331_CR28","doi-asserted-by":"publisher","first-page":"E1","DOI":"10.1097\/brs.0000000000003723","volume":"46","author":"DE Gelb","year":"2021","unstructured":"Gelb DE, Tareen J, Jazini E, Ludwig SC, Harris JA, Amin DB, Wang W, Van Horn MR, Patel PD, Mirabile BA, Bucklen BS (2021) Comprehensive evaluation of accessory rod position, rod material and diameter, use of cross-connectors, and anterior column support in a pedicle subtraction osteotomy model: part I: effects on apical rod strain: an in vitro and in silico biomechanical study. Spine (Phila Pa 1976) 46:E1\u2013E11. https:\/\/doi.org\/10.1097\/brs.0000000000003723","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-022-07331-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-022-07331-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-022-07331-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,5]],"date-time":"2022-11-05T17:20:00Z","timestamp":1667668800000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-022-07331-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,6]]},"references-count":28,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2022,11]]}},"alternative-id":["7331"],"URL":"https:\/\/doi.org\/10.1007\/s00586-022-07331-7","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,6]]},"assertion":[{"value":"19 October 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 April 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 July 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 August 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no conflicts of interest to declare that are relevant to the content of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}},{"value":"As the study involved no patient or clinical data, no ethical approval was required.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"As the study involved no patient or clinical data, consent to participate was not required.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"As the study involved no patient or clinical data, consent for publication was not required.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}