{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,18]],"date-time":"2026-07-18T09:58:41Z","timestamp":1784368721750,"version":"3.55.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,11,23]],"date-time":"2022-11-23T00:00:00Z","timestamp":1669161600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,11,23]],"date-time":"2022-11-23T00:00:00Z","timestamp":1669161600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100011852","name":"Paracelsus Medical University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100011852","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Measurement of neck rotation is currently reliant on radiologic imaging. Given the radiation exposure for CT imaging and the additional inconvenience for the patients, an alternative assessment is needed. Goniometers are comfortably to use and easy to access, also for private consulting. The aim of this study was the assessment of whether a handheld goniometer can be used for accurately measuring the rotation of C1-C2.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Clinical measurement of rotation was taken in flexed position of the neck. As comparison functional MRI was used. The measured rotation of C1-C2 was compared to identify the accuracy of the goniometer, in comparison to functional MRI scan.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Analysis of accuracy using a goniometer and dynamic MRI to assess C1-2 axial rotation showed significant differences for absolute values, but not regarding the percentage of rotation compared to total neck rotation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The goniometer is exact to impartially determine the percentage contribution of C1-2 rotation to total neck rotation.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00586-022-07464-9","type":"journal-article","created":{"date-parts":[[2022,11,23]],"date-time":"2022-11-23T13:30:35Z","timestamp":1669210235000},"page":"368-373","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Assessment of atlantoaxial rotation: how accurate is clinical measurement? a comparative study of cervical range of motion using MRI and standard orthopedic techniques"],"prefix":"10.1007","volume":"32","author":[{"given":"Michael","family":"Mayer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juliane","family":"Koller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Auffarth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5469-1236","authenticated-orcid":false,"given":"Berndt","family":"von Amelunxen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reinhold","family":"Ortmaier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wolfgang","family":"Hitzl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heiko","family":"Koller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,11,23]]},"reference":[{"key":"7464_CR1","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1016\/s0268-0033(00)00034-6","volume":"15","author":"N Bogduk","year":"2000","unstructured":"Bogduk N, Mercer S (2000) Biomechanics of the cervical spine. I: normal kinematics. Clin Biomech 15:633\u2013648. https:\/\/doi.org\/10.1016\/s0268-0033(00)00034-6","journal-title":"Clin Biomech"},{"key":"7464_CR2","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1053\/crad.2001.0703","volume":"57","author":"CJ Roche","year":"2002","unstructured":"Roche CJ, King SJ, Dangerfield PH, Carty HM (2002) The atlanto-axial joint: physiological range of rotation on MRI and CT. Clin Radiol 57:103\u2013108. https:\/\/doi.org\/10.1053\/crad.2001.0703","journal-title":"Clin Radiol"},{"key":"7464_CR3","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1227\/01.neu.0000134386.31806.a6","volume":"55","author":"D Pang","year":"2004","unstructured":"Pang D, Li V (2004) Atlantoaxial rotatory fixation: part 1\u2013biomechanics of normal rotation at the atlantoaxial joint in children. Neurosurgery 55:614\u2013616. https:\/\/doi.org\/10.1227\/01.neu.0000134386.31806.a6","journal-title":"Neurosurgery"},{"key":"7464_CR4","doi-asserted-by":"publisher","first-page":"S53","DOI":"10.1097\/01.brs.0000217941.55817.52","volume":"31","author":"TG Maak","year":"2006","unstructured":"Maak TG, Grauer JN (2006) The contemporary treatment of odontoid injuries. Spine 31:S53\u2013S60. https:\/\/doi.org\/10.1097\/01.brs.0000217941.55817.52","journal-title":"Spine"},{"key":"7464_CR5","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1097\/00007632-198910000-00007","volume":"14","author":"M Aebi","year":"1989","unstructured":"Aebi M, Etter C, Coscia M (1989) Fractures of the odontoid process treatment with anterior screw fixation. Spine 14:1065\u20131070. https:\/\/doi.org\/10.1097\/00007632-198910000-00007","journal-title":"Spine"},{"key":"7464_CR6","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1007\/BF00302707","volume":"2","author":"K Chiba","year":"1993","unstructured":"Chiba K, Fujimura Y, Toyama Y et al (1993) Anterior screw fixation for odontoid fracture: clinical results in 45 cases. Eur spine J 2:76\u201381. https:\/\/doi.org\/10.1007\/BF00302707","journal-title":"Eur spine J"},{"key":"7464_CR7","doi-asserted-by":"publisher","first-page":"227","DOI":"10.3171\/spi.2000.93.2.0227","volume":"93","author":"RI Apfelbaum","year":"2000","unstructured":"Apfelbaum RI, Lonser RR, Veres R, Casey A (2000) Direct anterior screw fixation for recent and remote odontoid fractures. J Neurosurg 93:227\u2013236. https:\/\/doi.org\/10.3171\/spi.2000.93.2.0227","journal-title":"J Neurosurg"},{"key":"7464_CR8","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1007\/BF02190576","volume":"3","author":"R Verheggen","year":"1994","unstructured":"Verheggen R, Jansen J (1994) Fractures of the odontoid process: analysis of the functional results after surgery. Eur spine J 3:146\u2013150. https:\/\/doi.org\/10.1007\/BF02190576","journal-title":"Eur spine J"},{"key":"7464_CR9","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1097\/00002517-199106000-00011","volume":"4","author":"B Jeanneret","year":"1991","unstructured":"Jeanneret B, Vernet O, Frei S, Magerl F (1991) Atlantoaxial mobility after screw fixation of the odontoid: a computed tomographic study. J Spinal Disord 4:203\u2013211. https:\/\/doi.org\/10.1097\/00002517-199106000-00011","journal-title":"J Spinal Disord"},{"key":"7464_CR10","doi-asserted-by":"publisher","first-page":"1135","DOI":"10.1007\/s00586-009-0901-4","volume":"18","author":"H Koller","year":"2009","unstructured":"Koller H, Acosta F, Forstner R et al (2009) C2-fractures: part II. a morphometrical analysis of computerized atlantoaxial motion, anatomical alignment and related clinical outcomes. Eur spine J 18:1135\u20131153. https:\/\/doi.org\/10.1007\/s00586-009-0901-4","journal-title":"Eur spine J"},{"key":"7464_CR11","doi-asserted-by":"publisher","first-page":"E751","DOI":"10.1097\/BRS.0000000000001370","volume":"41","author":"Q Guo","year":"2016","unstructured":"Guo Q, Zhang M, Wang L et al (2016) Comparison of atlantoaxial rotation and functional outcomes of two nonfusion techniques in the treatment of Anderson-D\u2019Alonzo type II odontoid fractures. Spine 41:E751\u2013E758. https:\/\/doi.org\/10.1097\/BRS.0000000000001370","journal-title":"Spine"},{"key":"7464_CR12","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1007\/s00590-013-1219-9","volume":"23","author":"Y Kawaguchi","year":"2013","unstructured":"Kawaguchi Y, Nagami S, Nakano M et al (2013) Relationship between postoperative axial symptoms and the rotational angle of the cervical spine after laminoplasty. Eur J Orthop Surg Traumatol 23:53\u201358. https:\/\/doi.org\/10.1007\/s00590-013-1219-9","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"7464_CR13","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1097\/BRS.0b013e3181c911a0","volume":"35","author":"H Koller","year":"2010","unstructured":"Koller H, Resch H, Acosta F et al (2010) Assessment of two measurement techniques of cervical spine and C1\u2013C2 rotation in the outcome research of axis fractures: a morphometrical analysis using dynamic computed tomography scanning. Spine 35:286\u2013290. https:\/\/doi.org\/10.1097\/BRS.0b013e3181c911a0","journal-title":"Spine"},{"key":"7464_CR14","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/j.spinee.2017.08.229","volume":"18","author":"MR Pourahmadi","year":"2018","unstructured":"Pourahmadi MR, Bagheri R, Taghipour M et al (2018) A new iPhone application for measuring active craniocervical range of motion in patients with non-specific neck pain: a reliability and validity study. Spine J 18:447\u2013457. https:\/\/doi.org\/10.1016\/j.spinee.2017.08.229","journal-title":"Spine J"},{"key":"7464_CR15","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/s0161-4754(99)70102-8","volume":"22","author":"HW Christensen","year":"1999","unstructured":"Christensen HW, Nilsson N (1999) The ability to reproduce the neutral zero position of the head. J Manipulative Physiol Ther 22:26\u201328. https:\/\/doi.org\/10.1016\/s0161-4754(99)70102-8","journal-title":"J Manipulative Physiol Ther"},{"key":"7464_CR16","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1007\/s00586-005-0963-x","volume":"15","author":"D Grob","year":"2006","unstructured":"Grob D, Bremerich FH, Dvorak J, Mannion AF (2006) Transarticular screw fixation for osteoarthritis of the atlanto axial segment. Eur spine J 15:283\u2013291. https:\/\/doi.org\/10.1007\/s00586-005-0963-x","journal-title":"Eur spine J"},{"key":"7464_CR17","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.jmpt.2008.03.012","volume":"31","author":"TM Hall","year":"2008","unstructured":"Hall TM, Robinson KW, Fujinawa O et al (2008) Intertester reliability and diagnostic validity of the cervical flexion-rotation test. J Manipulative Physiol Ther 31:293\u2013300. https:\/\/doi.org\/10.1016\/j.jmpt.2008.03.012","journal-title":"J Manipulative Physiol Ther"},{"key":"7464_CR18","doi-asserted-by":"publisher","first-page":"2318","DOI":"10.1097\/BRS.0b013e3181557222","volume":"32","author":"Y Sugimoto","year":"2007","unstructured":"Sugimoto Y, Tanaka M, Nakanishi K et al (2007) Assessing the range of cervical rotation in patients with rheumatoid arthritis after atlantoaxial screw fixation using axial CT. Spine 32:2318\u20132321. https:\/\/doi.org\/10.1097\/BRS.0b013e3181557222","journal-title":"Spine"},{"key":"7464_CR19","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/j.math.2010.10.002","volume":"16","author":"H Takasaki","year":"2011","unstructured":"Takasaki H, Hall T, Oshiro S et al (2011) Normal kinematics of the upper cervical spine during the flexion-rotation test\u2014In vivo measurements using magnetic resonance imaging. Man Ther 16:167\u2013171. https:\/\/doi.org\/10.1016\/j.math.2010.10.002","journal-title":"Man Ther"},{"key":"7464_CR20","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1097\/00007632-200002150-00009","volume":"25","author":"WH Castro","year":"2000","unstructured":"Castro WH, Sautmann A, Schilgen M, Sautmann M (2000) Noninvasive three-dimensional analysis of cervical spine motion in normal subjects in relation to age and sex An experimental examination. Spine 25:443\u2013449. https:\/\/doi.org\/10.1097\/00007632-200002150-00009","journal-title":"Spine"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-022-07464-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-022-07464-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-022-07464-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,27]],"date-time":"2023-01-27T20:38:40Z","timestamp":1674851920000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-022-07464-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,23]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,1]]}},"alternative-id":["7464"],"URL":"https:\/\/doi.org\/10.1007\/s00586-022-07464-9","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,23]]},"assertion":[{"value":"6 June 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 October 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 November 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 November 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"No conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}