{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T12:18:56Z","timestamp":1788437936149,"version":"build-2803163510"},"reference-count":55,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,12,7]],"date-time":"2022-12-07T00:00:00Z","timestamp":1670371200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,12,7]],"date-time":"2022-12-07T00:00:00Z","timestamp":1670371200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100017695","name":"Health Commission of Hunan Province","doi-asserted-by":"publisher","award":["202204073380"],"award-info":[{"award-number":["202204073380"]}],"id":[{"id":"10.13039\/100017695","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2023,1]]},"DOI":"10.1007\/s00586-022-07480-9","type":"journal-article","created":{"date-parts":[[2022,12,7]],"date-time":"2022-12-07T12:05:53Z","timestamp":1670414753000},"page":"261-270","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Is 3D-printed prosthesis stable and economic enough for anterior spinal column reconstruction after spinal tumor resection? A retrospective comparative study between 3D-printed off-the-shelf prosthesis and titanium mesh cage"],"prefix":"10.1007","volume":"32","author":[{"given":"Zejun","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guohua","family":"L\u00fc","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoxiao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haoyu","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hui","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Changyu","family":"Pan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0370-4954","authenticated-orcid":false,"given":"Lei","family":"Kuang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,12,7]]},"reference":[{"issue":"5","key":"7480_CR1","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1002\/jso.24026","volume":"112","author":"F Garofalo","year":"2015","unstructured":"Garofalo F, di Summa PG, Christoforidis D, Pracht M, Laudato P, Cherix S, Bouchaab H, Raffoul W, Demartines N, Matter M (2015) Multidisciplinary approach of lumbo-sacral chordoma: from oncological treatment to reconstructive surgery. J Surg Oncol 112(5):544\u2013554","journal-title":"J Surg Oncol"},{"issue":"6","key":"7480_CR2","first-page":"454","volume":"20","author":"C Greco","year":"2015","unstructured":"Greco C, Pares O, Pimentel N et al (2015) Spinal metastases: from conventional fractionated radiotherapy to single-dose SBRT. Reports Pract Oncol Radiotherapy J Greatpoland Cancer Center in Poznan Polish Soc Radiat Oncol 20(6):454\u2013463","journal-title":"Reports Pract Oncol Radiotherapy J Greatpoland Cancer Center in Poznan Polish Soc Radiat Oncol"},{"issue":"9","key":"7480_CR3","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1590\/0004-282X20150099","volume":"73","author":"AF Joaquim","year":"2015","unstructured":"Joaquim AF, Ann P, Ilya L et al (2015) An update in the management of spinal metastases. Arq Neuropsiquiatr 73(9):795","journal-title":"Arq Neuropsiquiatr"},{"issue":"1","key":"7480_CR4","doi-asserted-by":"publisher","first-page":"E16","DOI":"10.3171\/2016.8.FOCUS16112","volume":"42","author":"BD Elder","year":"2017","unstructured":"Elder BD, Ishida W, Goodwin CR et al (2017) Bone graft options for spinal fusion following resection of spinal column tumors: systematic review and meta-analysis. Neurosurg Focus 42(1):E16","journal-title":"Neurosurg Focus"},{"issue":"1","key":"7480_CR5","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1093\/neuros\/nyw057","volume":"81","author":"V Yanamadala","year":"2017","unstructured":"Yanamadala V, Rozman PA, Kumar JI, Schwab JH, Lee SG, Hornicek FJ, Curry WT Jr (2017) Vascularized fibular strut autografts in spinal reconstruction after resection of vertebral chordoma or chondrosarcoma: a retrospective series. Neurosurgery 81(1):156\u2013164","journal-title":"Neurosurgery"},{"issue":"10","key":"7480_CR6","doi-asserted-by":"publisher","first-page":"1150","DOI":"10.1097\/00007632-200405150-00019","volume":"29","author":"KU Lewandrowski","year":"2004","unstructured":"Lewandrowski KU, Hecht AC, Delaney TF et al (2004) Anterior spinal arthrodesis with structural cortical allografts and instrumentation for spine tumor surgery. Spine 29(10):1150","journal-title":"Spine"},{"key":"7480_CR7","doi-asserted-by":"crossref","unstructured":"Bridwell KH, Lenke LG , Mcenery KW et al (1995) Anterior fresh frozen structural allografts in the thoracic and lumbar spine. Do they work if combined with posterior fusion and instrumentation in adult patients with kyphosis or anterior column defects?. Spine 20(12):1410.","DOI":"10.1097\/00007632-199506020-00014"},{"key":"7480_CR8","doi-asserted-by":"crossref","unstructured":"Dvorak MF, Kwon BK, Fisher CG, Eiserloh HL 3rd, Boyd M, Wing PC (2003) Effectiveness of titanium mesh cylindrical cages in anterior column reconstruction after thoracic and lumbar vertebral body resection. Spine (Phila Pa 1976) 28(9):902\u2013908.","DOI":"10.1097\/01.BRS.0000058712.88053.13"},{"issue":"1","key":"7480_CR9","doi-asserted-by":"publisher","first-page":"37","DOI":"10.3928\/0147-7447-20020101-14","volume":"25","author":"S Boriani","year":"2002","unstructured":"Boriani S, Biagini R, Bandiera S et al (2002) Reconstruction of the anterior column of the thoracic and lumbar spine with a carbon fiber Stackable Cage System. Orthopedics 25(1):37\u201342","journal-title":"Orthopedics"},{"issue":"1","key":"7480_CR10","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1007\/s00586-011-1882-7","volume":"21","author":"A Viswanathan","year":"2012","unstructured":"Viswanathan A, Abd-El-Barr MM, Doppenberg E et al (2012) Initial experience with the use of an expandable titanium cage as a vertebral body replacement in patients with tumors of the spinal column: a report of 95 patients. Eur Spine J 21(1):84\u201392","journal-title":"Eur Spine J"},{"key":"7480_CR11","doi-asserted-by":"crossref","unstructured":"Glennie RA, Rampersaud YR, Boriani S, Reynolds JJ, Williams R, Gokaslan ZL, Schmidt MH, Varga PP, Fisher CG (2016) A systematic review with consensus expert opinion of best reconstructive techniques after osseous en bloc spinal column tumor resection. Spine (Phila Pa 1976) 41(Suppl 20):S205\u2013S211.","DOI":"10.1097\/BRS.0000000000001835"},{"issue":"10","key":"7480_CR12","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1097\/BSD.0000000000001026","volume":"33","author":"N Wallace","year":"2020","unstructured":"Wallace N, Schaffer NE, Aleem IS, Patel R (2020) 3D-printed patient-specific spine implants: a systematic review. Clin Spine Surg 33(10):400\u2013407","journal-title":"Clin Spine Surg"},{"issue":"6","key":"7480_CR13","doi-asserted-by":"publisher","first-page":"1248","DOI":"10.1007\/s00586-019-06236-2","volume":"29","author":"JL Burnard","year":"2020","unstructured":"Burnard JL, Parr WCH, Choy WJ, Walsh WR, Mobbs RJ (2020) 3D-printed spine surgery implants: a systematic review of the efficacy and clinical safety profile of patient-specific and off-the-shelf devices. Eur Spine J 29(6):1248\u20131260","journal-title":"Eur Spine J"},{"key":"7480_CR14","doi-asserted-by":"crossref","unstructured":"Kato S, Murakami H, Demura S et al (2014) Patient-reported outcome and quality of life after total en bloc spondylectomy for a primary spinal tumour. Bone Joint J 96-B(12):1693\u20131698.","DOI":"10.1302\/0301-620X.96B12.33832"},{"issue":"1","key":"7480_CR15","first-page":"37","volume":"17","author":"K Salame","year":"2015","unstructured":"Salame K, Regev G, Keynan O et al (2015) Total en bloc spondylectomy for vertebral tumors. Israel Med Assoc J IMAJ 17(1):37\u201341","journal-title":"Israel Med Assoc J IMAJ"},{"issue":"Suppl 6","key":"7480_CR16","doi-asserted-by":"publisher","first-page":"S116","DOI":"10.1016\/j.injury.2014.10.034","volume":"45","author":"GM Calori","year":"2014","unstructured":"Calori GM, Colombo M, Mazza EL et al (2014) Incidence of donor site morbidity following harvesting from iliac crest or RIA graft. Injury-Int J Care Injured 45(Suppl 6):S116\u2013S120","journal-title":"Injury-Int J Care Injured"},{"issue":"4\u20135","key":"7480_CR17","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1016\/j.wneu.2010.06.037","volume":"74","author":"R Harel","year":"2010","unstructured":"Harel R, Chao S, Krishnaney A et al (2010) Spine instrumentation failure after spine tumor resection and radiation: comparing conventional radiotherapy with stereotactic radiosurgery outcomes. World Neurosurg 74(4\u20135):517\u2013522","journal-title":"World Neurosurg"},{"issue":"12","key":"7480_CR18","doi-asserted-by":"publisher","first-page":"3916","DOI":"10.1007\/s00586-015-4154-0","volume":"25","author":"KM Salem","year":"2016","unstructured":"Salem KM, Fisher CG (2016) Anterior column reconstruction with PMMA: an effective long-term alternative in spinal oncologic surgery. Eur Spine J 25(12):3916\u20133922","journal-title":"Eur Spine J"},{"issue":"24","key":"7480_CR19","doi-asserted-by":"publisher","first-page":"1511","DOI":"10.1097\/BRS.0b013e3182a6427a","volume":"38","author":"K Yoshioka","year":"2013","unstructured":"Yoshioka K, Murakami H, Demura S et al (2013) Clinical outcome of spinal reconstruction after total en bloc spondylectomy at 3 or more levels. Spine 38(24):1511\u20131516","journal-title":"Spine"},{"issue":"10","key":"7480_CR20","first-page":"704","volume":"39","author":"CL Ventola","year":"2014","unstructured":"Ventola CL (2014) Medical applications for 3D printing: current and projected uses. P T 39(10):704\u2013711","journal-title":"P T"},{"issue":"7","key":"7480_CR21","doi-asserted-by":"publisher","first-page":"3240","DOI":"10.1021\/ac403397r","volume":"86","author":"BC Gross","year":"2014","unstructured":"Gross BC, Erkal JL, Lockwood SY et al (2014) Evaluation of 3D printing and its potential impact on biotechnology and the chemical sciences. Anal Chem 86(7):3240\u20133253","journal-title":"Anal Chem"},{"issue":"7","key":"7480_CR22","doi-asserted-by":"publisher","first-page":"1697","DOI":"10.1016\/j.xphs.2017.03.021","volume":"106","author":"L Zema","year":"2017","unstructured":"Zema L, Melocchi A, Maroni A, Gazzaniga A (2017) Three-dimensional printing of medicinal products and the challenge of personalized therapy. J Pharm Sci 106(7):1697\u20131705","journal-title":"J Pharm Sci"},{"key":"7480_CR23","doi-asserted-by":"crossref","unstructured":"Martelli N, Serrano C, H\u00e9l\u00e8ne VDB et al (2016) Advantages and disadvantages of 3-dimensional printing in surgery: asystematic review. Surgery, pp 1485\u20131500.","DOI":"10.1016\/j.surg.2015.12.017"},{"issue":"1","key":"7480_CR24","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1186\/s12938-016-0236-4","volume":"15","author":"P Tack","year":"2016","unstructured":"Tack P, Victor J, Gemmel P et al (2016) 3D-printing techniques in a medical setting: a systematic literature review. Biomed Eng Online 15(1):115","journal-title":"Biomed Eng Online"},{"issue":"6","key":"7480_CR25","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1016\/j.aorn.2016.10.010","volume":"104","author":"N Girard","year":"2016","unstructured":"Girard N (2016) Evidence appraisal of Malik HH, Darwood ARJ, Shaunak S, Kulatilake P, El-Hilly AA, Mulki O, Baskaradas A. Three-dimensional printing in surgery: a review of current surgical applications.: J Surg Res. 2015;199(2):512\u2013522. AORN J 104(6):601\u2013606","journal-title":"AORN J"},{"issue":"3","key":"7480_CR26","doi-asserted-by":"publisher","first-page":"433","DOI":"10.21037\/jss.2017.09.01","volume":"3","author":"B Wilcox","year":"2017","unstructured":"Wilcox B, Mobbs RJ, Wu AM et al (2017) Systematic review of 3D printing in spinal surgery: the current state of play. J Spine Surg 3(3):433\u2013443","journal-title":"J Spine Surg"},{"issue":"12","key":"7480_CR27","doi-asserted-by":"publisher","first-page":"3073","DOI":"10.1007\/s00586-018-5708-8","volume":"27","author":"M Girolami","year":"2018","unstructured":"Girolami M, Boriani S, Bandiera S, Barbanti-Br\u00f3dano G, Ghermandi R, Terzi S, Tedesco G, Evangelisti G, Pipola V, Gasbarrini A (2018) Biomimetic 3D-printed custom-made prosthesis for anterior column reconstruction in the thoracolumbar spine: a tailored option following en bloc resection for spinal tumors: Preliminary results on a case-series of 13 patients. Eur Spine J 27(12):3073\u20133083","journal-title":"Eur Spine J"},{"key":"7480_CR28","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.wneu.2018.01.078","volume":"112","author":"RJ Mobbs","year":"2018","unstructured":"Mobbs RJ, Wen JC, Wilson P et al (2018) L5 En-bloc vertebrectomy with customized reconstructive implant: comparison of patient-specific versus off-the-shelf implant. World Neurosurg 112:94\u2013100","journal-title":"World Neurosurg"},{"key":"7480_CR29","doi-asserted-by":"crossref","unstructured":"Tan X P, Tan YJ, Chow CSL et al (2017) Metallic powder-bed based 3D printing of cellular scaffolds for orthopaedic implants: A state-of-the-art review on manufacturing, topological design, mechanical properties and biocompatibility. Mater Sci Eng C 76(Jul):1328.","DOI":"10.1016\/j.msec.2017.02.094"},{"issue":"12","key":"7480_CR30","doi-asserted-by":"publisher","first-page":"8168","DOI":"10.3390\/ma7128168","volume":"7","author":"A Sidambe","year":"2014","unstructured":"Sidambe A (2014) Biocompatibility of advanced manufactured titanium implants\u2014a review. Materials (Basel, Switzerland) 7(12):8168","journal-title":"Materials (Basel, Switzerland)"},{"issue":"8","key":"7480_CR31","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1177\/0885328211431857","volume":"27","author":"A Palmquist","year":"2013","unstructured":"Palmquist A, Snis A, Emanuelsson L et al (2013) Long-term biocompatibility and osseointegration of electron beam melted, free-form-fabricated solid and porous titanium alloy: experimental studies in sheep. J Biomater Appl 27(8):1003\u20131016","journal-title":"J Biomater Appl"},{"issue":"3","key":"7480_CR32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s11011-017-9970-y","volume":"32","author":"X Wu","year":"2017","unstructured":"Wu X, Chen H, Huang C et al (2017) Curcumin attenuates surgery-induced cognitive dysfunction in aged mice. Metab Brain Dis 32(3):1\u201310","journal-title":"Metab Brain Dis"},{"key":"7480_CR33","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1186\/s12891-015-0546-x","volume":"16","author":"E Chong","year":"2015","unstructured":"Chong E, Pelletier MH, Mobbs RJ, Walsh WR (2015) The design evolution of interbody cages in anterior cervical discectomy and fusion: a systematic review. BMC Musculoskelet Disord 16:99","journal-title":"BMC Musculoskelet Disord"},{"issue":"2","key":"7480_CR34","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1111\/os.12098","volume":"6","author":"PJ Rao","year":"2014","unstructured":"Rao PJ, Pelletier MH, Walsh WR, Mobbs RJ (2014) Spine interbody implants: material selection and modification, functionalization and bioactivation of surfaces to improve osseointegration. Orthop Surg 6(2):81\u201389","journal-title":"Orthop Surg"},{"issue":"8","key":"7480_CR35","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1097\/00007632-200104150-00022","volume":"26","author":"K Hasegawa","year":"2001","unstructured":"Hasegawa K, Abe M, Washio T et al (2001) An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density. Spine 26(8):957","journal-title":"Spine"},{"issue":"7","key":"7480_CR36","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1097\/BSD.0b013e318158de22","volume":"21","author":"Y Chen","year":"2008","unstructured":"Chen Y, Chen D, Guo Y et al (2008) Subsidence of titanium mesh cage: a study based on 300 cases. J Spinal Disord Tech 21(7):489\u2013492","journal-title":"J Spinal Disord Tech"},{"key":"7480_CR37","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/j.jmbbm.2018.05.040","volume":"85","author":"M Ahmed","year":"2018","unstructured":"Ahmed M, Michael T, Damiano P (2018) Cervical fusion cage computationally optimized with porous architected Titanium for minimized subsidence. J Mech Behav Biomed Mater 85:134\u2013151","journal-title":"J Mech Behav Biomed Mater"},{"issue":"1","key":"7480_CR38","first-page":"11","volume":"6","author":"M Salchow-Gille","year":"2021","unstructured":"Salchow-Gille M, Rieger B, Reinshagen C, Molcanyi M, Lemke J, Brautferger U, Sitoci-Ficici KH, Polanski W, Pinzer T, Schackert G (2021) Prospective surgical solutions in degenerative spine: spinal simulation for optimal choice of implant and targeted device development. Innov Surg Sci 6(1):11\u201324","journal-title":"Innov Surg Sci"},{"issue":"10","key":"7480_CR39","doi-asserted-by":"publisher","first-page":"1613","DOI":"10.1016\/j.spinee.2019.04.018","volume":"19","author":"SJ Park","year":"2019","unstructured":"Park SJ, Lee CS, Chang BS, Kim YH, Kim H, Kim SI, Chang SY, Korean Spine Tumor Study Group (2019) Rod fracture and related factors after total en bloc spondylectomy. Spine J 19(10):1613\u20131619","journal-title":"Spine J"},{"issue":"7","key":"7480_CR40","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1111\/j.1600-0501.2008.01534.x-i2","volume":"19","author":"G Alsaadi","year":"2008","unstructured":"Alsaadi G, Quirynen M, Kom\u00e1rek A, van Steenberghe D (2008) Impact of local and systemic factors on the incidence of late oral implant loss. Clin Oral Implants Res 19(7):670\u2013676","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"7480_CR41","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1097\/00007632-198001000-00009","volume":"5","author":"T Hansson","year":"1980","unstructured":"Hansson T, Roos B, Nachemson A (1980) The bone mineral content and ultimate compressive strength of lumbar vertebrae. Spine 5(1):46","journal-title":"Spine"},{"issue":"8","key":"7480_CR42","doi-asserted-by":"publisher","first-page":"1206","DOI":"10.2106\/00004623-198567080-00010","volume":"67","author":"R Mcbroom","year":"1985","unstructured":"Mcbroom R (1985) Prediction of vertebral body compressive fracture using quantitative computed tomography. J Bone Joint Surg-Am 67(8):1206\u20131214","journal-title":"J Bone Joint Surg-Am"},{"key":"7480_CR43","doi-asserted-by":"crossref","unstructured":"Hansson T, Keller T, Spengler D. Mechanical behavior of the human lumbar spine. II. Fatigue strength during dynamic compressive loading. Journal of Orthopaedic Research Official Publication of the Orthopaedic Research Society, 2010, 5(4):479.","DOI":"10.1002\/jor.1100050403"},{"issue":"6","key":"7480_CR44","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1016\/j.jos.2018.06.009","volume":"23","author":"JH Cho","year":"2018","unstructured":"Cho JH, Hwang CJ, Kim H, Joo YS, Lee DH, Lee CS (2018) Effect of osteoporosis on the clinical and radiological outcomes following one-level posterior lumbar interbody fusion. J Orthop Sci 23(6):870\u2013877","journal-title":"J Orthop Sci"},{"key":"7480_CR45","doi-asserted-by":"crossref","unstructured":"Hoshijima K (1997) Strength and stability of posterior lumbar interbody fusion. Comparison of titanium fiber mesh implant and tricortical bone graft. Spine 22(11):1181.","DOI":"10.1097\/00007632-199706010-00002"},{"key":"7480_CR46","doi-asserted-by":"publisher","first-page":"e346","DOI":"10.6061\/clinics\/2019\/e346","volume":"74","author":"Z Wang","year":"2019","unstructured":"Wang Z, Liu Y, Rong Z, Wang C, Liu X, Zhang F, Zhang Z, Xu J, Dai F (2019) Clinical evaluation of a bone cement-injectable cannulated pedicle screw augmented with polymethylmethacrylate: 128 osteoporotic patients with 42 months of follow-up. Clinics (Sao Paulo) 74:e346","journal-title":"Clinics (Sao Paulo)"},{"issue":"1","key":"7480_CR47","doi-asserted-by":"publisher","first-page":"3929","DOI":"10.1038\/s41598-020-60980-w","volume":"10","author":"YY Liu","year":"2020","unstructured":"Liu YY, Xiao J, Yin X, Liu MY, Zhao JH, Liu P, Dai F (2020) Clinical efficacy of bone cement-injectable cannulated pedicle screw short segment fixation for lumbar spondylolisthesis with osteoporosise. Sci Rep 10(1):3929","journal-title":"Sci Rep"},{"issue":"1","key":"7480_CR48","doi-asserted-by":"publisher","first-page":"31","DOI":"10.22603\/ssrr.1.2016-0005","volume":"1","author":"K Yoshioka","year":"2017","unstructured":"Yoshioka K, Murakami H, Demura S et al (2017) Risk factors of instrumentation failure after multilevel total en bloc spondylectomy. Spine Surg Relat Res 1(1):31\u201339","journal-title":"Spine Surg Relat Res"},{"issue":"10","key":"7480_CR49","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1097\/BRS.0b013e3181f8cb4e","volume":"36","author":"AC Disch","year":"2011","unstructured":"Disch AC, Schaser KD, Melcher I et al (2011) Oncosurgical results of multilevel thoracolumbar en-bloc spondylectomy and reconstruction with a carbon composite vertebral body replacement system. Spine 36(10):647\u2013655","journal-title":"Spine"},{"issue":"4","key":"7480_CR50","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1007\/s00586-008-0599-8","volume":"17","author":"U Liljenqvist","year":"2008","unstructured":"Liljenqvist U, Lerner T, Halm H et al (2008) En bloc spondylectomy in malignant tumors of the spine. Eur Spine J 17(4):600\u2013609","journal-title":"Eur Spine J"},{"issue":"3","key":"7480_CR51","doi-asserted-by":"publisher","first-page":"320","DOI":"10.3171\/2011.5.SPINE10813","volume":"15","author":"M Matsumoto","year":"2011","unstructured":"Matsumoto M, Watanabe K, Tsuji T et al (2011) Late instrumentation failure after total en bloc spondylectomy. J Neurosurg Spine 15(3):320\u2013327","journal-title":"J Neurosurg Spine"},{"issue":"5","key":"7480_CR52","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2019-036365","volume":"10","author":"Z Zhu","year":"2020","unstructured":"Zhu Z, Xing W, Lizarondo L et al (2020) Psychometric properties of self-reported financial toxicity measures in cancer survivors: a systematic review protocol using COSMIN methodology. BMJ Open 10(5):e036365","journal-title":"BMJ Open"},{"issue":"10","key":"7480_CR53","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1016\/j.amjmed.2018.05.020","volume":"131","author":"AM Gilligan","year":"2018","unstructured":"Gilligan AM, Alberts DS, Roe DJ, Skrepnek GH (2018) Death or debt? National estimates of financial toxicity in persons with newly-diagnosed cancer. Am J Med 131(10):1187\u20131199.e5","journal-title":"Am J Med"},{"issue":"7","key":"7480_CR54","doi-asserted-by":"publisher","first-page":"1902","DOI":"10.1007\/s00586-016-4871-z","volume":"26","author":"R Wei","year":"2017","unstructured":"Wei R, Guo W, Ji T, Zhang Y, Liang H (2017) One-step reconstruction with a 3D-printed, custom-made prosthesis after total en bloc sacrectomy: a technical note. Eur Spine J 26(7):1902\u20131909","journal-title":"Eur Spine J"},{"key":"7480_CR55","doi-asserted-by":"publisher","first-page":"e327","DOI":"10.1016\/j.wneu.2019.09.002","volume":"133","author":"R Lador","year":"2020","unstructured":"Lador R, Regev G, Salame K, Khashan M, Lidar Z (2020) Use of 3-dimensional printing technology in complex spine surgeries. World Neurosurg 133:e327\u2013e341","journal-title":"World Neurosurg"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-022-07480-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-022-07480-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-022-07480-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,2]],"date-time":"2023-12-02T16:24:17Z","timestamp":1701534257000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-022-07480-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,7]]},"references-count":55,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,1]]}},"alternative-id":["7480"],"URL":"https:\/\/doi.org\/10.1007\/s00586-022-07480-9","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,7]]},"assertion":[{"value":"15 July 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 October 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 November 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 December 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"There are no competing interests in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}