{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:20:47Z","timestamp":1792783247435,"version":"4.5.0"},"reference-count":68,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2023,1,28]],"date-time":"2023-01-28T00:00:00Z","timestamp":1674864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,1,28]],"date-time":"2023-01-28T00:00:00Z","timestamp":1674864000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Boca Raton Regional Hospita","award":["SP 19-579"],"award-info":[{"award-number":["SP 19-579"]}],"id":[{"id":"https:\/\/ror.org\/01phhgk62","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2023,3]]},"DOI":"10.1007\/s00586-023-07530-w","type":"journal-article","created":{"date-parts":[[2023,1,28]],"date-time":"2023-01-28T08:45:12Z","timestamp":1674895512000},"page":"957-968","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":58,"title":["Factors influencing cage subsidence in anterior cervical corpectomy and discectomy: a systematic review"],"prefix":"10.1007","volume":"32","author":[{"given":"Utpal Kanti","family":"Dhar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emma Lilly","family":"Menzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maohua","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vivian","family":"Hagerty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy","family":"O\u2019Connor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chi-Tay","family":"Tsai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank D.","family":"Vrionis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,1,28]]},"reference":[{"key":"7530_CR1","doi-asserted-by":"publisher","first-page":"24","DOI":"10.21608\/ESJ.2015.3953","volume":"14","author":"S Hamada","year":"2015","unstructured":"Hamada S, Abou-Zeid A (2015) Evaluation of subsidence in stand-alone cervical cage: incidence, risk factors and effects on clinical and radiological picture. Egypt Spine J 14:24\u201331. https:\/\/doi.org\/10.21608\/ESJ.2015.3953","journal-title":"Egypt Spine J"},{"key":"7530_CR2","doi-asserted-by":"publisher","first-page":"16","DOI":"10.4055\/CIOS.2011.3.1.16","volume":"3","author":"JJ Yang","year":"2011","unstructured":"Yang JJ, Yu CH, Chang BS et al (2011) Subsidence and nonunion after anterior cervical interbody fusion using a stand-alone polyetheretherketone (PEEK) cage. Clin Orthop Surg 3:16\u201323. https:\/\/doi.org\/10.4055\/CIOS.2011.3.1.16","journal-title":"Clin Orthop Surg"},{"key":"7530_CR3","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1227\/01.NEU.0000197258.30821.50","volume":"58","author":"RHMA Bartels","year":"2006","unstructured":"Bartels RHMA, Donk RD, Feuth T (2006) Subsidence of stand-alone cervical carbon fiber cages. Neurosurgery 58:502\u2013507. https:\/\/doi.org\/10.1227\/01.NEU.0000197258.30821.50","journal-title":"Neurosurgery"},{"key":"7530_CR4","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1177\/230949901602400122","volume":"24","author":"EM Pinder","year":"2016","unstructured":"Pinder EM, Sharp DJ (2016) Cage subsidence after anterior cervical discectomy and fusion using a cage alone or combined with anterior plate fixation. J Orthop Surg 24:97\u2013100. https:\/\/doi.org\/10.1177\/230949901602400122","journal-title":"J Orthop Surg"},{"key":"7530_CR5","doi-asserted-by":"publisher","first-page":"1343","DOI":"10.1007\/S00402-014-2047-Z","volume":"134","author":"TH Kao","year":"2014","unstructured":"Kao TH, Wu CH, Chou YC et al (2014) Risk factors for subsidence in anterior cervical fusion with stand-alone polyetheretherketone (PEEK) cages: a review of 82 cases and 182 levels. Arch Orthop Trauma Surg 134:1343\u20131351. https:\/\/doi.org\/10.1007\/S00402-014-2047-Z","journal-title":"Arch Orthop Trauma Surg"},{"key":"7530_CR6","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/J.JOCN.2016.12.037","volume":"38","author":"SC Yson","year":"2017","unstructured":"Yson SC, Sembrano JN, Santos ERG (2017) Comparison of allograft and polyetheretherketone (PEEK) cage subsidence rates in anterior cervical discectomy and fusion (ACDF). J Clin Neurosci 38:118\u2013121. https:\/\/doi.org\/10.1016\/J.JOCN.2016.12.037","journal-title":"J Clin Neurosci"},{"key":"7530_CR7","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/J.CLINEURO.2018.04.033","volume":"170","author":"J Zhou","year":"2018","unstructured":"Zhou J, Li J, Lin H et al (2018) A comparison of a self-locking stand-alone cage and anterior cervical plate for ACDF: minimum 3-year assessment of radiographic and clinical outcomes. Clin Neurol Neurosurg 170:73\u201378. https:\/\/doi.org\/10.1016\/J.CLINEURO.2018.04.033","journal-title":"Clin Neurol Neurosurg"},{"key":"7530_CR8","doi-asserted-by":"publisher","first-page":"630","DOI":"10.31616\/ASJ.2018.0234","volume":"13","author":"RA de Leo-Vargas","year":"2019","unstructured":"de Leo-Vargas RA, Mu\u00f1oz-Romero I, Mondrag\u00f3n-Soto MG, Mart\u00ednez-Anda JJ (2019) Locking stand-alone cage constructs for the treatment of cervical spine degenerative disease. Asian Spine J 13:630\u2013637. https:\/\/doi.org\/10.31616\/ASJ.2018.0234","journal-title":"Asian Spine J"},{"key":"7530_CR9","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1016\/S1000-1948(09)60042-3","volume":"24","author":"W Jianxin","year":"2009","unstructured":"Jianxin W, Xiaojian Y (2009) Anatomy-related risk factors in Harm\u2019s mesh subsidence in cervical reconstruction after one-level corpectomy. J Med Coll PLA 24:228\u2013234. https:\/\/doi.org\/10.1016\/S1000-1948(09)60042-3","journal-title":"J Med Coll PLA"},{"key":"7530_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/S13037-014-0043-4","volume":"8","author":"D Zajonz","year":"2014","unstructured":"Zajonz D, Franke AC, der von H\u00f6h N et al (2014) Is the radiographic subsidence of stand-alone cages associated with adverse clinical outcomes after cervical spine fusion? An observational cohort study with 2-year follow-up outcome scoring. Patient Saf Surg 8:1\u20139. https:\/\/doi.org\/10.1186\/S13037-014-0043-4","journal-title":"Patient Saf Surg"},{"key":"7530_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/S12891-021-04244-2","volume":"22","author":"J Sun","year":"2021","unstructured":"Sun J, Wang Q, Cai D et al (2021) A lattice topology optimization of cervical interbody fusion cage and finite element comparison with ZK60 and Ti-6Al-4V cages. BMC Musculoskelet Disord 22:1\u201314. https:\/\/doi.org\/10.1186\/S12891-021-04244-2","journal-title":"BMC Musculoskelet Disord"},{"key":"7530_CR12","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/J.JOCN.2016.01.042","volume":"33","author":"JY Park","year":"2016","unstructured":"Park JY, Choi KY, Moon BJ et al (2016) Subsidence after single-level anterior cervical fusion with a stand-alone cage. J Clin Neurosci 33:83\u201388. https:\/\/doi.org\/10.1016\/J.JOCN.2016.01.042","journal-title":"J Clin Neurosci"},{"key":"7530_CR13","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.1016\/J.JOCN.2011.11.043","volume":"19","author":"T Yamagata","year":"2012","unstructured":"Yamagata T, Takami T, Uda T et al (2012) Outcomes of contemporary use of rectangular titanium stand-alone cages in anterior cervical discectomy and fusion: cage subsidence and cervical alignment. J Clin Neurosci 19:1673\u20131678. https:\/\/doi.org\/10.1016\/J.JOCN.2011.11.043","journal-title":"J Clin Neurosci"},{"key":"7530_CR14","doi-asserted-by":"crossref","unstructured":"Igarashi H, Hoshino M, Omori K et al (2019) Factors influencing interbody cage subsidence following anterior cervical discectomy and fusion","DOI":"10.1097\/BSD.0000000000000843"},{"key":"7530_CR15","doi-asserted-by":"publisher","first-page":"e249","DOI":"10.1016\/j.wneu.2019.10.042","volume":"134","author":"KJ Song","year":"2020","unstructured":"Song KJ, Choi BW, Ham DH, Kim HJ (2020) Prognosis of hardware-related problems in anterior cervical discectomy and fusion with cage and plate constructs. World Neurosurg 134:e249\u2013e255. https:\/\/doi.org\/10.1016\/j.wneu.2019.10.042","journal-title":"World Neurosurg"},{"key":"7530_CR16","doi-asserted-by":"publisher","first-page":"607","DOI":"10.2106\/00004623-195840030-00009","volume":"40-A","author":"GW Smith","year":"1958","unstructured":"Smith GW, Robinson RA (1958) The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Jt Surg Am 40-A:607\u2013624. https:\/\/doi.org\/10.2106\/00004623-195840030-00009","journal-title":"J Bone Jt Surg Am"},{"key":"7530_CR17","doi-asserted-by":"publisher","first-page":"602","DOI":"10.3171\/JNS.1958.15.6.0602","volume":"15","author":"RB Cloward","year":"1958","unstructured":"Cloward RB (1958) The anterior approach for removal of ruptured cervical disks. J Neurosurg 15:602\u2013617. https:\/\/doi.org\/10.3171\/JNS.1958.15.6.0602","journal-title":"J Neurosurg"},{"key":"7530_CR18","doi-asserted-by":"crossref","unstructured":"Weber MH, Fortin M, Shen J et al (2016) Graft subsidence and revision rates following anterior cervical corpectomy a clinical study comparing different interbody cages","DOI":"10.1097\/BSD.0000000000000428"},{"key":"7530_CR19","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1007\/S00586-004-0707-3","volume":"13","author":"W B\u00f6rm","year":"2004","unstructured":"B\u00f6rm W, Seitz K (2004) Use of cervical stand-alone cages. Eur Spine J 13:474\u2013475. https:\/\/doi.org\/10.1007\/S00586-004-0707-3","journal-title":"Eur Spine J"},{"key":"7530_CR20","doi-asserted-by":"publisher","first-page":"33","DOI":"10.21129\/nerve.2019.5.2.33","volume":"5","author":"J-S Kang","year":"2019","unstructured":"Kang J-S, Oh S-H, Cho P-G (2019) Subsidence after anterior cervical interbody fusion using a zero-profile device. Nerve 5:33\u201340. https:\/\/doi.org\/10.21129\/nerve.2019.5.2.33","journal-title":"Nerve"},{"key":"7530_CR21","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-019-3036-8","author":"C Ji","year":"2020","unstructured":"Ji C, Yu S, Yan N et al (2020) Risk factors for subsidence of titanium mesh cage following single-level anterior cervical corpectomy and fusion. BMC Musculoskelet Disord. https:\/\/doi.org\/10.1186\/s12891-019-3036-8","journal-title":"BMC Musculoskelet Disord"},{"key":"7530_CR22","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/398396","author":"JH Klingler","year":"2014","unstructured":"Klingler JH, Kr\u00fcger MT, Sircar R et al (2014) PEEK cages versus PMMA spacers in anterior cervical discectomy: comparison of fusion, subsidence, sagittal alignment, and clinical outcome with a minimum 1-year follow-up. Sci World J. https:\/\/doi.org\/10.1155\/2014\/398396","journal-title":"Sci World J"},{"key":"7530_CR23","first-page":"201","volume":"24","author":"MFTJHC Chiang","year":"2004","unstructured":"Chiang MFTJHC et al (2004) Finite element analysis of cage subsidence in cervical interbody fusion. J Med Biol Eng 24:201\u2013208","journal-title":"J Med Biol Eng"},{"key":"7530_CR24","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1000097","volume":"6","author":"D Moher","year":"2009","unstructured":"Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group T (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 6:e1000097","journal-title":"PLoS Med"},{"key":"7530_CR25","doi-asserted-by":"publisher","first-page":"225","DOI":"10.31616\/ASJ.2018.0193","volume":"13","author":"EPL Ng","year":"2019","unstructured":"Ng EPL, Yip ASL, Wan KHM et al (2019) Stand-alone cervical cages in 2-level anterior interbody fusion in cervical spondylotic myelopathy: results from a minimum 2-year follow-up. Asian Spine J 13:225\u2013232. https:\/\/doi.org\/10.31616\/ASJ.2018.0193","journal-title":"Asian Spine J"},{"key":"7530_CR26","doi-asserted-by":"publisher","first-page":"13","DOI":"10.14245\/KJS.2016.13.1.13","volume":"13","author":"SY Han","year":"2016","unstructured":"Han SY, Kim HW, Lee CY et al (2016) Stand-alone cages for anterior cervical fusion: Are there no problems? Korean J Spine 13:13\u201319. https:\/\/doi.org\/10.14245\/KJS.2016.13.1.13","journal-title":"Korean J Spine"},{"key":"7530_CR27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1471-2474-13-172","volume":"13","author":"M Cabraja","year":"2012","unstructured":"Cabraja M, Oezdemir S, Koeppen D, Kroppenstedt S (2012) Anterior cervical discectomy and fusion: comparison of titanium and polyetheretherketone cages. BMC Musculoskelet Disord 13:1\u20139. https:\/\/doi.org\/10.1186\/1471-2474-13-172","journal-title":"BMC Musculoskelet Disord"},{"key":"7530_CR28","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1007\/S00590-014-1547-4\/FIGURES\/4","volume":"25","author":"O Nemoto","year":"2015","unstructured":"Nemoto O, Kitada A, Naitou S et al (2015) Stand-alone anchored cage versus cage with plating for single-level anterior cervical discectomy and fusion: a prospective, randomized, controlled study with a 2-year follow-up. Eur J Orthop Surg Traumatol 25:127\u2013134. https:\/\/doi.org\/10.1007\/S00590-014-1547-4\/FIGURES\/4","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"7530_CR29","doi-asserted-by":"publisher","first-page":"E8","DOI":"10.1097\/BSD.0000000000000938","volume":"33","author":"JW Hur","year":"2020","unstructured":"Hur JW, Ryu KS, Ahn S et al (2020) Comparative analysis of 2 different types of titanium mesh cage for single-level anterior cervical corpectomy and fusion in terms of postoperative subsidence and sagittal alignment. Clin Spine Surg 33:E8\u2013E13. https:\/\/doi.org\/10.1097\/BSD.0000000000000938","journal-title":"Clin Spine Surg"},{"key":"7530_CR30","doi-asserted-by":"publisher","first-page":"e9808","DOI":"10.1097\/MD.0000000000009808","volume":"97","author":"Y Lu","year":"2018","unstructured":"Lu Y, Bao W, Wang Z et al (2018) Comparison of the clinical effects of zero-profile anchored spacer (ROI-C) and conventional cage-plate construct for the treatment of noncontiguous bilevel of cervical degenerative disc disease (CDDD): a minimum 2-year follow-up. Medicine 97:e9808. https:\/\/doi.org\/10.1097\/MD.0000000000009808","journal-title":"Medicine"},{"key":"7530_CR31","doi-asserted-by":"publisher","first-page":"896","DOI":"10.14444\/7137","volume":"14","author":"AP Maccormick","year":"2020","unstructured":"Maccormick AP, Sharma H (2020) Analysis of the variables affecting the incidence, location, and severity of cage subsidence following anterior cervical discectomy and fusion operation. Int J Spine Surg 14:896\u2013900. https:\/\/doi.org\/10.14444\/7137","journal-title":"Int J Spine Surg"},{"key":"7530_CR32","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1007\/s10143-008-0168-y","volume":"32","author":"E Kast","year":"2009","unstructured":"Kast E, Derakhshani S, Bothmann M, Oberle J (2009) Subsidence after anterior cervical inter-body fusion. A randomized prospective clinical trial. Neurosurg Rev 32:207\u2013214. https:\/\/doi.org\/10.1007\/s10143-008-0168-y","journal-title":"Neurosurg Rev"},{"key":"7530_CR33","doi-asserted-by":"publisher","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","volume":"28","author":"SM Kurtz","year":"2007","unstructured":"Kurtz SM, Devine JN (2007) PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 28:4845\u20134869","journal-title":"Biomaterials"},{"key":"7530_CR34","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.jocn.2017.06.062","volume":"44","author":"S Seaman","year":"2017","unstructured":"Seaman S, Kerezoudis P, Bydon M et al (2017) Titanium vs. polyetheretherketone (PEEK) interbody fusion: meta-analysis and review of the literature. J Clin Neurosci 44:23\u201329","journal-title":"J Clin Neurosci"},{"key":"7530_CR35","doi-asserted-by":"publisher","first-page":"1539","DOI":"10.1007\/s00586-013-2772-y","volume":"22","author":"Y Chen","year":"2013","unstructured":"Chen Y, Wang X, Lu X et al (2013) Comparison of titanium and polyetheretherketone (PEEK) cages in the surgical treatment of multilevel cervical spondylotic myelopathy: a prospective, randomized, control study with over 7-year follow-up. Eur Spine J 22:1539\u20131546. https:\/\/doi.org\/10.1007\/s00586-013-2772-y","journal-title":"Eur Spine J"},{"key":"7530_CR36","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1007\/S00264-007-0378-X","volume":"32","author":"JC Liao","year":"2008","unstructured":"Liao JC, Niu CC, Chen WJ, Chen LH (2008) Polyetheretherketone (PEEK) cage filled with cancellous allograft in anterior cervical discectomy and fusion. Int Orthop 32:643\u2013648. https:\/\/doi.org\/10.1007\/S00264-007-0378-X","journal-title":"Int Orthop"},{"key":"7530_CR37","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/S13037-017-0128-Y","volume":"11","author":"O Suess","year":"2017","unstructured":"Suess O, Schomaker M, Cabraja M et al (2017) Empty polyetheretherketone (PEEK) cages in anterior cervical diskectomy and fusion (ACDF) show slow radiographic fusion that reduces clinical improvement: results from the prospective multicenter \u201cPIERCE-PEEK\u201d study. Patient Saf Surg 11:1\u201312. https:\/\/doi.org\/10.1186\/S13037-017-0128-Y","journal-title":"Patient Saf Surg"},{"key":"7530_CR38","doi-asserted-by":"publisher","first-page":"E208","DOI":"10.1097\/BSD.0B013E31826851A4","volume":"29","author":"MH Pelletier","year":"2016","unstructured":"Pelletier MH, Cordaro N, Punjabi VM et al (2016) PEEK versus Ti interbody fusion devices resultant fusion, bone apposition, initial and 26-week biomechanics. Clin Spine Surg 29:E208\u2013E214. https:\/\/doi.org\/10.1097\/BSD.0B013E31826851A4","journal-title":"Clin Spine Surg"},{"key":"7530_CR39","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/J.SPINEE.2009.10.014","volume":"10","author":"HT Hee","year":"2010","unstructured":"Hee HT, Kundnani V (2010) Rationale for use of polyetheretherketone polymer interbody cage device in cervical spine surgery. Spine J 10:66\u201369. https:\/\/doi.org\/10.1016\/J.SPINEE.2009.10.014","journal-title":"Spine J"},{"key":"7530_CR40","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1016\/J.JOCN.2011.06.029","volume":"19","author":"AE Castellvi","year":"2012","unstructured":"Castellvi AE, Castellvi A, Clabeaux DH (2012) Corpectomy with titanium cage reconstruction in the cervical spine. J Clin Neurosci 19:517\u2013521. https:\/\/doi.org\/10.1016\/J.JOCN.2011.06.029","journal-title":"J Clin Neurosci"},{"key":"7530_CR41","doi-asserted-by":"publisher","first-page":"3106","DOI":"10.12659\/MSM.901993","volume":"23","author":"T Lu","year":"2017","unstructured":"Lu T, Liu C, Yang B et al (2017) Single-level anterior cervical corpectomy and fusion using a new 3D-printed anatomy-adaptive titanium mesh cage for treatment of cervical spondylotic myelopathy and ossification of the posterior longitudinal ligament: a retrospective case series study. Med Sci Monit 23:3106\u20133113. https:\/\/doi.org\/10.12659\/MSM.901993","journal-title":"Med Sci Monit"},{"key":"7530_CR42","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1007\/S00701-018-3490-3","volume":"160","author":"I Noordhoek","year":"2018","unstructured":"Noordhoek I, Koning MT, Jacobs WCH, Vleggeert-Lankamp CLA (2018) Incidence and clinical relevance of cage subsidence in anterior cervical discectomy and fusion: a systematic review. Acta Neurochir 160:873\u2013880. https:\/\/doi.org\/10.1007\/S00701-018-3490-3","journal-title":"Acta Neurochir"},{"key":"7530_CR43","doi-asserted-by":"publisher","first-page":"1446","DOI":"10.1016\/J.SPINEE.2013.08.030","volume":"15","author":"RFMR Kersten","year":"2015","unstructured":"Kersten RFMR, van Gaalen SM, de Gast A, \u00d6ner FC (2015) Polyetheretherketone (PEEK) cages in cervical applications: a systematic review. Spine J 15:1446\u20131460. https:\/\/doi.org\/10.1016\/J.SPINEE.2013.08.030","journal-title":"Spine J"},{"key":"7530_CR44","doi-asserted-by":"publisher","first-page":"e336","DOI":"10.1016\/J.WNEU.2020.10.084","volume":"146","author":"K McCaffrey","year":"2021","unstructured":"McCaffrey K, McCaffrey MH, Pelletier MH et al (2021) Load sharing and endplate pressure distribution in anterior interbody fusion influenced by graft choice. World Neurosurg 146:e336\u2013e340. https:\/\/doi.org\/10.1016\/J.WNEU.2020.10.084","journal-title":"World Neurosurg"},{"key":"7530_CR45","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/J.JMBBM.2018.01.017","volume":"80","author":"RD Carpenter","year":"2018","unstructured":"Carpenter RD, Klosterhoff BS, Torstrick FB et al (2018) Effect of porous orthopaedic implant material and structure on load sharing with simulated bone ingrowth: a finite element analysis comparing titanium and PEEK. J Mech Behav Biomed Mater 80:68\u201376. https:\/\/doi.org\/10.1016\/J.JMBBM.2018.01.017","journal-title":"J Mech Behav Biomed Mater"},{"key":"7530_CR46","doi-asserted-by":"publisher","first-page":"126","DOI":"10.13004\/KJNT.2021.17.E23","volume":"17","author":"TY An","year":"2021","unstructured":"An TY, Kim JY, Lee YS (2021) Risk factors and radiologic changes in subsidence after single-level anterior cervical corpectomy: a minimum follow-up of 2 years. Korean J Neurotrauma 17:126\u2013135. https:\/\/doi.org\/10.13004\/KJNT.2021.17.E23","journal-title":"Korean J Neurotrauma"},{"key":"7530_CR47","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1016\/J.SPINEE.2011.05.007","volume":"11","author":"WJ Anderst","year":"2011","unstructured":"Anderst WJ, Thorhauer ED, Lee JY et al (2011) Cervical spine bone mineral density as a function of vertebral level and anatomic location. Spine J 11:659\u2013667. https:\/\/doi.org\/10.1016\/J.SPINEE.2011.05.007","journal-title":"Spine J"},{"key":"7530_CR48","doi-asserted-by":"publisher","first-page":"2832","DOI":"10.1007\/S00586-014-3725-9","volume":"24","author":"C Brenke","year":"2015","unstructured":"Brenke C, Dostal M, Scharf J et al (2015) Influence of cervical bone mineral density on cage subsidence in patients following stand-alone anterior cervical discectomy and fusion. Eur Spine J 24:2832\u20132840. https:\/\/doi.org\/10.1007\/S00586-014-3725-9","journal-title":"Eur Spine J"},{"key":"7530_CR49","doi-asserted-by":"publisher","first-page":"189","DOI":"10.3340\/JKNS.2013.54.3.189","volume":"54","author":"JI Park","year":"2013","unstructured":"Park JI, Cho DC, Kim KT, Sung JK (2013) Anterior cervical discectomy and fusion using a stand-alone polyetheretherketone cage packed with local autobone: assessment of bone fusion and subsidence. J Korean Neurosurg Soc 54:189\u2013193. https:\/\/doi.org\/10.3340\/JKNS.2013.54.3.189","journal-title":"J Korean Neurosurg Soc"},{"key":"7530_CR50","doi-asserted-by":"publisher","first-page":"160","DOI":"10.5435\/JAAOS-D-16-00390","volume":"25","author":"PB Suh","year":"2017","unstructured":"Suh PB, Puttlitz C, Lewis C et al (2017) The effect of cervical interbody cage morphology, material composition, and substrate density on cage subsidence. J Am Acad Orthop Surg 25:160\u2013168. https:\/\/doi.org\/10.5435\/JAAOS-D-16-00390","journal-title":"J Am Acad Orthop Surg"},{"key":"7530_CR51","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1097\/00007632-200104150-00021","volume":"26","author":"TH Lim","year":"2001","unstructured":"Lim TH, Kwon H, Jeon CH et al (2001) Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical spine fusion. Spine 26:951\u2013956. https:\/\/doi.org\/10.1097\/00007632-200104150-00021","journal-title":"Spine"},{"key":"7530_CR52","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/S12891-016-1274-6","volume":"17","author":"M Yin","year":"2016","unstructured":"Yin M, Ma J, Huang Q et al (2016) The new Zero-P implant can effectively reduce the risk of postoperative dysphagia and complications compared with the traditional anterior cage and plate: a systematic review and meta-analysis. BMC Musculoskelet Disord 17:1\u20139. https:\/\/doi.org\/10.1186\/S12891-016-1274-6","journal-title":"BMC Musculoskelet Disord"},{"key":"7530_CR53","doi-asserted-by":"publisher","first-page":"874","DOI":"10.1016\/J.SPINEE.2021.01.015","volume":"21","author":"M Lin","year":"2021","unstructured":"Lin M, Shapiro SZ, Doulgeris J et al (2021) Cage-screw and anterior plating combination reduces the risk of micromotion and subsidence in multilevel anterior cervical discectomy and fusion\u2014a finite element study. Spine J 21:874\u2013882. https:\/\/doi.org\/10.1016\/J.SPINEE.2021.01.015","journal-title":"Spine J"},{"key":"7530_CR54","doi-asserted-by":"publisher","first-page":"1489","DOI":"10.12659\/MSM.913630","volume":"25","author":"P Ouyang","year":"2019","unstructured":"Ouyang P, Lu T, He X et al (2019) Biomechanical comparison of integrated fixation cage versus anterior cervical plate and cage in anterior cervical corpectomy and fusion (ACCF): a finite element analysis. Med Sci Monit 25:1489\u20131498. https:\/\/doi.org\/10.12659\/MSM.913630","journal-title":"Med Sci Monit"},{"key":"7530_CR55","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/S41598-021-94787-0","volume":"11","author":"Y Wang","year":"2021","unstructured":"Wang Y, Zhan Y, Yang H et al (2021) A novel anatomic titanium mesh cage for reducing the subsidence rate after anterior cervical corpectomy: a finite element study. Sci Rep 11:1\u20139. https:\/\/doi.org\/10.1038\/S41598-021-94787-0","journal-title":"Sci Rep"},{"key":"7530_CR56","doi-asserted-by":"publisher","first-page":"e87","DOI":"10.1016\/J.WNEU.2019.05.037","volume":"129","author":"N Liu","year":"2019","unstructured":"Liu N, Lu T, Wang Y et al (2019) Effects of new cage profiles on the improvement in biomechanical performance of multilevel anterior cervical corpectomy and fusion: a finite element analysis. World Neurosurg 129:e87\u2013e96. https:\/\/doi.org\/10.1016\/J.WNEU.2019.05.037","journal-title":"World Neurosurg"},{"key":"7530_CR57","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/J.JMBBM.2018.05.040","volume":"85","author":"A Moussa","year":"2018","unstructured":"Moussa A, Tanzer M, Pasini D (2018) Cervical fusion cage computationally optimized with porous architected Titanium for minimized subsidence. J Mech Behav Biomed Mater 85:134\u2013151. https:\/\/doi.org\/10.1016\/J.JMBBM.2018.05.040","journal-title":"J Mech Behav Biomed Mater"},{"key":"7530_CR58","doi-asserted-by":"publisher","first-page":"203","DOI":"10.3171\/2009.2.SPINE08723","volume":"11","author":"TC Ryken","year":"2009","unstructured":"Ryken TC, Heary RF, Matz PG et al (2009) Techniques for cervical interbody grafting. J Neurosurg Spine 11:203\u2013220. https:\/\/doi.org\/10.3171\/2009.2.SPINE08723","journal-title":"J Neurosurg Spine"},{"key":"7530_CR59","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1007\/S00586-008-0878-4","volume":"18","author":"AMT Chau","year":"2009","unstructured":"Chau AMT, Mobbs RJ (2009) Bone graft substitutes in anterior cervical discectomy and fusion. Eur Spine J 18:449\u2013464. https:\/\/doi.org\/10.1007\/S00586-008-0878-4","journal-title":"Eur Spine J"},{"key":"7530_CR60","doi-asserted-by":"publisher","first-page":"E1239","DOI":"10.1016\/J.SPINEE.2011.08.405","volume":"11","author":"J Shen","year":"2011","unstructured":"Shen J, Weber M, Hu S et al (2011) Graft subsidence following anterior cervical corpectomy: a clinical study comparing different interbody cages. The Spine J 11:E1239\u2013E1245. https:\/\/doi.org\/10.1016\/J.SPINEE.2011.08.405","journal-title":"The Spine J"},{"key":"7530_CR61","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1007\/S00701-010-0821-4","volume":"153","author":"J Zhou","year":"2011","unstructured":"Zhou J, Xia Q, Dong J et al (2011) Comparison of stand-alone polyetheretherketone cages and iliac crest autografts for the treatment of cervical degenerative disc diseases. Acta Neurochir 153:115\u2013122. https:\/\/doi.org\/10.1007\/S00701-010-0821-4","journal-title":"Acta Neurochir"},{"key":"7530_CR62","doi-asserted-by":"publisher","first-page":"1","DOI":"10.5402\/2012\/452703","volume":"2012","author":"H Liu","year":"2012","unstructured":"Liu H, Ploumis A, Li C et al (2012) Polyetheretherketone cages alone with allograft for three-level anterior cervical fusion. ISRN Neurol 2012:1\u20135. https:\/\/doi.org\/10.5402\/2012\/452703","journal-title":"ISRN Neurol"},{"key":"7530_CR63","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1097\/00007632-200301150-00008","volume":"28","author":"JS Silber","year":"2003","unstructured":"Silber JS, Anderson DG, Daffner SD et al (2003) Donor site morbidity after anterior iliac crest bone harvest for single-level anterior cervical discectomy and fusion. Spine 28:134\u2013139. https:\/\/doi.org\/10.1097\/00007632-200301150-00008","journal-title":"Spine"},{"key":"7530_CR64","doi-asserted-by":"publisher","first-page":"e199","DOI":"10.1016\/J.WNEU.2021.07.013","volume":"154","author":"PS Manickam","year":"2021","unstructured":"Manickam PS, Roy S, Shetty GM (2021) Biomechanical evaluation of a novel S-type, dynamic zero-profile cage design for anterior cervical discectomy and fusion with variations in bone graft shape: a finite element analysis. World Neurosurg 154:e199\u2013e214. https:\/\/doi.org\/10.1016\/J.WNEU.2021.07.013","journal-title":"World Neurosurg"},{"key":"7530_CR65","first-page":"7411","volume":"8","author":"J Wu","year":"2015","unstructured":"Wu J, Luo D, Ye X et al (2015) Anatomy-related risk factors for the subsidence of titanium mesh cage in cervical reconstruction after one-level corpectomy. Int J Clin Exp Med 8:7411","journal-title":"Int J Clin Exp Med"},{"key":"7530_CR66","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1097\/BRS.0000000000000400","volume":"39","author":"YS Lee","year":"2014","unstructured":"Lee YS, Kim YB, Park SW (2014) Risk factors for postoperative subsidence of single-level anterior cervical discectomy and fusion: the significance of the preoperative cervical alignment. Spine 39:1280\u20131287. https:\/\/doi.org\/10.1097\/BRS.0000000000000400","journal-title":"Spine"},{"key":"7530_CR67","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/J.JOCN.2020.01.056","volume":"74","author":"Y Nakanishi","year":"2020","unstructured":"Nakanishi Y, Naito K, Yamagata T et al (2020) Safety of anterior cervical discectomy and fusion using titanium-coated polyetheretherketone stand-alone cages: multicenter prospective study of incidence of cage subsidence. J Clin Neurosci 74:47\u201354. https:\/\/doi.org\/10.1016\/J.JOCN.2020.01.056","journal-title":"J Clin Neurosci"},{"key":"7530_CR68","doi-asserted-by":"publisher","DOI":"10.1088\/1757-899X\/912\/2\/022025","author":"S Choudhury","year":"2020","unstructured":"Choudhury S, Raja D, Roy S, Datta S (2020) Stress analysis of different types of cages in cervical vertebrae: a finite element study. IOP Conf Ser Mater Sci Eng. https:\/\/doi.org\/10.1088\/1757-899X\/912\/2\/022025","journal-title":"IOP Conf Ser Mater Sci Eng"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-023-07530-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-023-07530-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-023-07530-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,7]],"date-time":"2023-03-07T06:10:12Z","timestamp":1678169412000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-023-07530-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,28]]},"references-count":68,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2023,3]]}},"alternative-id":["7530"],"URL":"https:\/\/doi.org\/10.1007\/s00586-023-07530-w","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,28]]},"assertion":[{"value":"7 September 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 December 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 January 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they do not have any conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}