{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T03:13:01Z","timestamp":1740107581093,"version":"3.37.3"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2024,4,4]],"date-time":"2024-04-04T00:00:00Z","timestamp":1712188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,4,4]],"date-time":"2024-04-04T00:00:00Z","timestamp":1712188800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2024,6]]},"DOI":"10.1007\/s00586-024-08230-9","type":"journal-article","created":{"date-parts":[[2024,4,4]],"date-time":"2024-04-04T15:02:26Z","timestamp":1712242946000},"page":"2298-2303","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Impact of osteosclerosis on cervical pedicle screw insertion using preoperative CT-based navigation"],"prefix":"10.1007","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0718-6357","authenticated-orcid":false,"given":"Masashi","family":"Uehara","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shota","family":"Ikegami","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroki","family":"Oba","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinari","family":"Miyaoka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Terue","family":"Hatakenaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daisuke","family":"Kurogochi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takuma","family":"Fukuzawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinji","family":"Sasao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuhiko","family":"Mimura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"Takahashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,4,4]]},"reference":[{"key":"8230_CR1","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1097\/00002517-199407010-00003","volume":"7","author":"K Abumi","year":"1994","unstructured":"Abumi K, Itoh H, Taneichi H, Kaneda K (1994) Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7:19\u201328","journal-title":"J Spinal Disord"},{"key":"8230_CR2","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1097\/00002517-199407030-00004","volume":"7","author":"B Janneret","year":"1994","unstructured":"Janneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture separation: results of an anatomical study and operative technique. J Spinal Disord 7:222\u2013229","journal-title":"J Spinal Disord"},{"key":"8230_CR3","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1097\/00003086-199902000-00009","volume":"359","author":"SC Ludwig","year":"1999","unstructured":"Ludwig SC, Kramer DL, Vaccaro AR, Albert TJ (1999) Transpedicular screw fixation of the cervical spine. Clin Orthop Relat Res 359:77\u201388","journal-title":"Clin Orthop Relat Res"},{"key":"8230_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/00007632-199701010-00001","volume":"22","author":"NA Ebraheim","year":"1997","unstructured":"Ebraheim NA, Xu R, Knight T, Yeasting RA (1997) Morphometric evaluation of lower cervical pedicle and its projection. Spine 22:1\u20136","journal-title":"Spine"},{"key":"8230_CR5","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1097\/00007632-200005150-00002","volume":"25","author":"MM Panjabi","year":"2000","unstructured":"Panjabi MM, Shin EK, Chen NC, Wang JL (2000) Internal morphology of human cervical pedicles. Spine 25:1197\u20131205","journal-title":"Spine"},{"issue":"1 suppl","key":"8230_CR6","doi-asserted-by":"publisher","first-page":"230949902110128","DOI":"10.1177\/23094990211012865","volume":"29","author":"N Lange","year":"2021","unstructured":"Lange N, Meyer B, Meyer HS (2021) Navigation for surgical treatment of disorders of the cervical spine-a systematic review. J Orthop Surg (Hong Kong) 29(1 suppl):23094990211012864. https:\/\/doi.org\/10.1177\/23094990211012865","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"8230_CR7","doi-asserted-by":"publisher","first-page":"e460","DOI":"10.1016\/j.wneu.2021.12.077","volume":"159","author":"HK Shin","year":"2022","unstructured":"Shin HK, Jeon SR, Roh SW, Park JH (2022) Benefits and pitfalls of O-arm navigation in cervical pedicle screw. World Neurosurg 159:e460\u2013e465","journal-title":"World Neurosurg"},{"key":"8230_CR8","doi-asserted-by":"publisher","first-page":"241","DOI":"10.4184\/asj.2012.6.4.241","volume":"6","author":"M Uehara","year":"2012","unstructured":"Uehara M, Takahashi J, Ogihara N, Hirabayashi H, Hashidate H, Mukaiyama K, Shimizu M, Kato H (2012) Cervical pedicle screw fixation combined with laminoplasty for cervical spondylotic myelopathy with instability. Asian Spine J 6:241\u2013248","journal-title":"Asian Spine J"},{"key":"8230_CR9","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1177\/21925682221098965","volume":"14","author":"F Lovecchio","year":"2024","unstructured":"Lovecchio F, Ang B, Louie PK, Chaudary C, Shah SP, Punyala A, Yao YC, Steinhaus M, McCarthy MH, Huang R, Lebl D, Lafage V, Albert TJ, Iyer S, Qureshi S, Kim HJ (2024) Bone density distribution in the cervical spine. Global Spine J 14:169\u2013176","journal-title":"Global Spine J"},{"issue":"2 Suppl","key":"8230_CR10","first-page":"223","volume":"97","author":"G Rao","year":"2002","unstructured":"Rao G, Brodke DS, Rondina M, Dailey AT (2002) Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement. J Neurosurg 97(2 Suppl):223\u2013226","journal-title":"J Neurosurg"},{"key":"8230_CR11","doi-asserted-by":"publisher","first-page":"192","DOI":"10.3758\/BF03206482","volume":"11","author":"EJ Wagenmakers","year":"2004","unstructured":"Wagenmakers EJ, Farrell S (2004) AIC model selection using Akaike weights. Psychon Bull Rev 11:192\u2013196","journal-title":"Psychon Bull Rev"},{"key":"8230_CR12","doi-asserted-by":"publisher","first-page":"1504","DOI":"10.1007\/s00586-013-2719-3","volume":"22","author":"R Tauchi","year":"2013","unstructured":"Tauchi R, Imagama S, Sakai Y, Ito Z, Ando K, Muramoto A, Matsui H, Matsumoto T, Ishiguro N (2013) The correlation between cervical range of motion and misplacement of cervical pedicle screws during cervical posterior spinal fixation surgery using a CT-based navigation system. Eur Spine J 22:1504\u20131508","journal-title":"Eur Spine J"},{"key":"8230_CR13","doi-asserted-by":"publisher","first-page":"606","DOI":"10.3171\/2010.5.SPINE09993","volume":"13","author":"Y Ishikawa","year":"2010","unstructured":"Ishikawa Y, Kanemura T, Yoshida G, Ito Z, Muramoto A, Ohno S (2010) Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement. J Neurosurg Spine 13:606\u2013611","journal-title":"J Neurosurg Spine"},{"key":"8230_CR14","doi-asserted-by":"publisher","first-page":"E104","DOI":"10.1097\/BSD.0000000000001141","volume":"35","author":"SH Farber","year":"2022","unstructured":"Farber SH, Godzik J, Hlubek RJ, Zhou JJ, Walker CT, Kakarla UK, Uribe JS, Turner JD (2022) Accuracy of subaxial cervical pedicle screw placement using direct visualization versus computed tomography-based navigation. Clin Spine Surg 35:E104\u2013E110","journal-title":"Clin Spine Surg"},{"key":"8230_CR15","first-page":"799","volume":"82","author":"H Nakashima","year":"2020","unstructured":"Nakashima H, Ishikawa Y, Ando K, Kobayashi K, Ishiguro N, Imagama S (2020) An intraoperative 3D image-based navigation error during cervical pedicle screw insertion. Nagoya J Med Sci 82:799\u2013805","journal-title":"Nagoya J Med Sci"},{"key":"8230_CR16","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.jocn.2021.03.009","volume":"88","author":"K Satake","year":"2021","unstructured":"Satake K, Kanemura T, Ito K, Tanaka S, Morita Y, Nakashima H, Ouchida J, Imagama S (2021) Pedicle screw placement with use of a navigated surgical drill at subaxial cervical spine. J Clin Neurosci 88:28\u201333","journal-title":"J Clin Neurosci"},{"key":"8230_CR17","doi-asserted-by":"publisher","first-page":"2189","DOI":"10.1007\/s00586-014-3502-9","volume":"23","author":"M Uehara","year":"2014","unstructured":"Uehara M, Takahashi J, Ikegami S, Mukaiyama K, Kuraishi S, Shimizu M, Futatsugi T, Ogihara N, Hashidate H, Hirabayashi H, Kato H (2014) Screw perforation features in 129 consecutive patients performed computer-guided cervical pedicle screw insertion. Eur Spine J 23:2189\u20132195","journal-title":"Eur Spine J"},{"key":"8230_CR18","doi-asserted-by":"publisher","first-page":"472","DOI":"10.3171\/spi.2006.4.6.472","volume":"4","author":"M Chazono","year":"2006","unstructured":"Chazono M, Soshi S, Inoue T, Kida Y, Ushiku C (2006) Anatomical considerations for cervical pedicle screw insertion: the use of multiplanar computerized tomography reconstruction measurements. J Neurosurg Spine 4:472\u2013477","journal-title":"J Neurosurg Spine"},{"key":"8230_CR19","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1016\/j.spinee.2009.04.021","volume":"9","author":"A Onibokun","year":"2009","unstructured":"Onibokun A, Khoo LT, Bistazzoni S, Chen NF, Sassi M (2009) Anatomical considerations for cervical pedicle screw insertion: the use of multiplanar computerized tomography measurements in 122 consecutive clinical cases. Spine J 9:729\u2013734","journal-title":"Spine J"},{"key":"8230_CR20","doi-asserted-by":"publisher","first-page":"564","DOI":"10.1007\/s00586-008-0584-2","volume":"17","author":"M Reinhold","year":"2008","unstructured":"Reinhold M, Bach C, Audig\u00e9 L, Bale R, Attal R, Blauth M, Magerl F (2008) Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature. Eur Spine J 17:564\u2013575","journal-title":"Eur Spine J"},{"key":"8230_CR21","doi-asserted-by":"publisher","first-page":"1343","DOI":"10.1007\/s00701-010-0665-y","volume":"152","author":"Y Sugimoto","year":"2010","unstructured":"Sugimoto Y, Ito Y, Tomioka M, Shimokawa T, Shiozaki Y, Mazaki T, Tanaka M (2010) Vertebral rotation during pedicle screw insertion in patients with cervical injury. Acta Neurochir (Wien) 152:1343\u20131346","journal-title":"Acta Neurochir (Wien)"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-024-08230-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-024-08230-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-024-08230-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,28]],"date-time":"2024-06-28T05:06:41Z","timestamp":1719551201000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-024-08230-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,4]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["8230"],"URL":"https:\/\/doi.org\/10.1007\/s00586-024-08230-9","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"type":"print","value":"0940-6719"},{"type":"electronic","value":"1432-0932"}],"subject":[],"published":{"date-parts":[[2024,4,4]]},"assertion":[{"value":"29 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 February 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 March 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 April 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all study participants.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}