{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T01:26:41Z","timestamp":1782350801445,"version":"3.54.5"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2024,10,4]],"date-time":"2024-10-04T00:00:00Z","timestamp":1728000000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,10,4]],"date-time":"2024-10-04T00:00:00Z","timestamp":1728000000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2024,12]]},"DOI":"10.1007\/s00586-024-08506-0","type":"journal-article","created":{"date-parts":[[2024,10,4]],"date-time":"2024-10-04T11:02:35Z","timestamp":1728039755000},"page":"4730-4739","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Impact of landmark crater creation on improving accuracy of pedicle screw insertion in robot-assisted scoliosis surgery"],"prefix":"10.1007","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8064-6607","authenticated-orcid":false,"given":"Hiroki","family":"Oba","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shota","family":"Ikegami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masashi","family":"Uehara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Terue","family":"Hatakenaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshinari","family":"Miyaoka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daisuke","family":"Kurogochi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuma","family":"Fukuzawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinji","family":"Sasao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keisuke","family":"Shigenobu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fumiaki","family":"Makiyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michihiko","family":"Koseki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masashi","family":"Neo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Takahashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,10,4]]},"reference":[{"key":"8506_CR1","doi-asserted-by":"crossref","unstructured":"Suk SI, Lee CK, Kim WJ, Chung YJ, Park YB (1995) Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine (Phila Pa 1976) 20:1399\u2009\u2013\u2009405","DOI":"10.1097\/00007632-199520120-00012"},{"key":"8506_CR2","doi-asserted-by":"publisher","first-page":"E1064","DOI":"10.1097\/BRS.0b013e3181ed29c1","volume":"35","author":"K Watanabe","year":"2010","unstructured":"Watanabe K, Yamazaki A, Hirano T, Izumi T, Sano A, Morita O, Kikuchi R, Ito T (2010) Descending aortic injury by a thoracic pedicle screw during posterior reconstructive surgery: a case report. Spine (Phila Pa 1976) 35:E1064\u2013E1068","journal-title":"Spine (Phila Pa 1976)"},{"key":"8506_CR3","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1097\/01.bsd.0000154448.90707.a8","volume":"18","author":"Y Smorgick","year":"2005","unstructured":"Smorgick Y, Millgram MA, Anekstein Y, Floman Y, Mirovsky Y (2005) Accuracy and safety of thoracic pedicle screw placement in spinal deformities. J Spinal Disord Tech 18:522\u2013526","journal-title":"J Spinal Disord Tech"},{"key":"8506_CR4","doi-asserted-by":"publisher","first-page":"1074","DOI":"10.1016\/j.jvs.2007.11.005","volume":"47","author":"SK Kakkos","year":"2008","unstructured":"Kakkos SK, Shepard AD (2008) Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature. J Vasc Surg 47:1074\u20131082","journal-title":"J Vasc Surg"},{"key":"8506_CR5","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1016\/j.jvs.2003.10.056","volume":"39","author":"ME Minor","year":"2004","unstructured":"Minor ME, Morrissey NJ, Peress R et al (2004) Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report. J Vasc Surg 39:893\u2013896","journal-title":"J Vasc Surg"},{"key":"8506_CR6","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1016\/j.jfma.2013.09.014","volume":"114","author":"X Tong","year":"2015","unstructured":"Tong X, Gu P, Yu D, Guo F, Lin X (2015) An endovascular treatment of a thoracic aortic injury caused by a misplaced pedicle screw: case report and review of the literature. J Formos Med Assoc 114:464\u2013468","journal-title":"J Formos Med Assoc"},{"key":"8506_CR7","doi-asserted-by":"publisher","first-page":"1781","DOI":"10.1007\/s00586-015-4163-z","volume":"25","author":"TM Chapman","year":"2016","unstructured":"Chapman TM, Blizzard DJ, Brown CR (2016) CT accuracy of percutaneous versus open pedicle screw techniques: a series of 1609 screws. Eur Spine J 25:1781\u20131786","journal-title":"Eur Spine J"},{"key":"8506_CR8","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/j.spinee.2022.09.004","volume":"23","author":"H Oba","year":"2023","unstructured":"Oba H, Uehara M, Ikegami S, Hatakenaka T, Kamanaka T, Miyaoka Y, Kurogouchi D, Fukuzawa T, Mimura T, Tanikawa Y, Koseki M, Ohba T, Takahashi J (2023) Tips and pitfalls to improve accuracy and reduce radiation exposure in intraoperative CT navigation for pediatric scoliosis: a systematic review. Spine J 23:183\u2013196","journal-title":"Spine J"},{"key":"8506_CR9","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.spinee.2022.10.006","volume":"23","author":"AV Matur","year":"2023","unstructured":"Matur AV, Palmisciano P, Duah HO, Chilakapati SS, Cheng JS, Adogwa O (2023) Robotic and navigated pedicle screws are safer and more accurate than fluoroscopic freehand screws: a systematic review and meta-analysis. Spine J 23:197\u2013208","journal-title":"Spine J"},{"key":"8506_CR10","doi-asserted-by":"publisher","first-page":"E10","DOI":"10.3171\/2021.10.FOCUS21509","volume":"52","author":"A Naik","year":"2022","unstructured":"Naik A, Smith AD, Shaffer A, Krist DT, Moawad CM, MacInnis BR, Teal K, Hassaneen W, Arnold PM (2022) Evaluating robotic pedicle screw placement against conventional modalities: a systematic review and network meta-analysis. Neurosurg Focus 52:E10","journal-title":"Neurosurg Focus"},{"key":"8506_CR11","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1016\/j.jos.2022.06.012","volume":"28","author":"Y Torii","year":"2023","unstructured":"Torii Y, Ueno J, Iinuma M, Yoshida A, Niki H, Akazawa T (2023) Accuracy of robotic-assisted pedicle screw placement comparing junior surgeons with expert surgeons: can junior surgeons place pedicle screws as accurately as expert surgeons? J Orthop Sci 28:961\u2013965","journal-title":"J Orthop Sci"},{"key":"8506_CR12","doi-asserted-by":"crossref","unstructured":"Ansorge A, Sarwahi V, Bazin L, Vazquez O, De Marco G, Dayer R (2023) Accuracy and safety of Pedicle Screw Placement for treating adolescent idiopathic scoliosis: a narrative review comparing available techniques. Diagnostics (Basel) 132402","DOI":"10.3390\/diagnostics13142402"},{"key":"8506_CR13","doi-asserted-by":"publisher","first-page":"187","DOI":"10.21037\/jss.2018.04.01","volume":"4","author":"KA Shaw","year":"2018","unstructured":"Shaw KA, Murphy JS, Devito DP (2018) Accuracy of robot-assisted pedicle screw insertion in adolescent idiopathic scoliosis: is triggered electromyographic pedicle screw stimulation necessary? J Spine Surg 4:187\u2013194","journal-title":"J Spine Surg"},{"key":"8506_CR14","doi-asserted-by":"publisher","first-page":"e92","DOI":"10.2106\/JBJS.M.01058","volume":"96","author":"V Sarwahi","year":"2014","unstructured":"Sarwahi V, Sugarman EP, Wollowick AL, Amaral TD, Lo Y, Thornhill B (2014) Prevalence, distribution, and Surgical relevance of abnormal pedicles in spines with adolescent idiopathic scoliosis vs. no deformity: a CT-Based study. J Bone Joint Surg Am 96:e92","journal-title":"J Bone Joint Surg Am"},{"key":"8506_CR15","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1007\/s00776-015-0746-0","volume":"20","author":"T Akazawa","year":"2015","unstructured":"Akazawa T, Kotani T, Sakuma T, Minami S, Tsukamoto S, Ishige M (2015) Evaluation of pedicle screw placement by pedicle channel grade in adolescent idiopathic scoliosis: should we challenge narrow pedicles? J Orthop Sci 20:818\u2013822","journal-title":"J Orthop Sci"},{"key":"8506_CR16","doi-asserted-by":"publisher","first-page":"E1357","DOI":"10.1097\/BRS.0000000000003673","volume":"45","author":"H Oba","year":"2020","unstructured":"Oba H, Ikegami S, Kuraishi S, Uehara M, Takizawa T, Munakata R, Hatakenaka T, Kamanaka T, Koseki M, Takahashi J (2020) Perforation Rate of Pedicle screws using hybrid operating Room Combined with Intraoperative Computed Tomography Navigation for adolescent idiopathic scoliosis: impact of Distance from the reference Frame and other Risk factors. Spine (Phila Pa 1976) 45:E1357\u2013e64","journal-title":"Spine (Phila Pa 1976)"},{"key":"8506_CR17","doi-asserted-by":"crossref","unstructured":"Tanikawa Y, Oba H, Fujii M, Ikegami S, Uehara M, Mimura T, Miyagawa J, Hatakenaka T, Kuraishi S, Takizawa T, Munakata R, Kamanaka T, Miyaoka Y, Michihiko K, Takahashi J (2022) Intraoperative Cone Beam CT in Hybrid Operation Room for Pediatric Scoliosis Patients: Comparison of Pedicle Screw Violation Rate at Normal and Low Radiation Doses. Spine (Phila Pa 1976). 47:E507-e13","DOI":"10.1097\/BRS.0000000000004226"},{"key":"8506_CR18","doi-asserted-by":"publisher","first-page":"3133","DOI":"10.1007\/s00586-023-07842-x","volume":"32","author":"H Oba","year":"2023","unstructured":"Oba H, Ikegami S, Uehara M, Hatakenaka T, Kanemura T, Takahashi J (2023) Reduction in CT scan number with the reference frame middle attachment method in intraoperative CT navigation for adolescent idiopathic scoliosis. Eur Spine J 32:3133\u20133139","journal-title":"Eur Spine J"},{"key":"8506_CR19","first-page":"223","volume":"97","author":"G Rao","year":"2002","unstructured":"Rao G, Brodke DS, Rondina M, Dailey AT (2002) Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement. J Neurosurg 97:223\u2013226","journal-title":"J Neurosurg"},{"key":"8506_CR20","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1016\/j.spinee.2022.01.006","volume":"22","author":"T Hatakenaka","year":"2022","unstructured":"Hatakenaka T, Oba H, Ikegami S, Kuraishi S, Uehara M, Mimura T, Takizawa T, Munakata R, Kamanaka T, Miyaoka Y, Koseki M, Takahashi J (2022) Comparison of differences and random errors in pedicle diameter measurements between MRI and CT: observational study of 315 pedicles in Lenke type 1 adolescent idiopathic scoliosis patients. Spine J 22:1002\u20131011. https:\/\/doi.org\/10.1016\/j.spinee.2022.01.006Epub 2022 Jan 10","journal-title":"Spine J"},{"key":"8506_CR21","doi-asserted-by":"crossref","unstructured":"Joseph JR, Smith BW, Liu X, Park P (2017) Current applications of robotics in spine surgery: a systematic review of the literature. Neurosurg Focus. 2017; 42 (5): E2","DOI":"10.3171\/2017.2.FOCUS16544"},{"key":"8506_CR22","doi-asserted-by":"publisher","first-page":"E1463","DOI":"10.1097\/BRS.0000000000002737","volume":"43","author":"H Oba","year":"2018","unstructured":"Oba H, Ebata S, Takahashi J, Koyama K, Uehara M, Kato H, Haro H, Ohba T (2018) Pedicle perforation while inserting screws using O-arm Navigation during surgery for adolescent idiopathic scoliosis: risk factors and effect of insertion order. Spine (Phila Pa 1976) 43:E1463\u2013e8","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-024-08506-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-024-08506-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-024-08506-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,25]],"date-time":"2024-11-25T16:03:59Z","timestamp":1732550639000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-024-08506-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,4]]},"references-count":22,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["8506"],"URL":"https:\/\/doi.org\/10.1007\/s00586-024-08506-0","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,4]]},"assertion":[{"value":"10 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 September 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 September 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 October 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that there are no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Approval code 5984, Shinshu University School of Medicine.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained by all participants in this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}