{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T03:43:50Z","timestamp":1792554230406,"version":"4.5.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,2,3]],"date-time":"2025-02-03T00:00:00Z","timestamp":1738540800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,2,3]],"date-time":"2025-02-03T00:00:00Z","timestamp":1738540800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2025,4]]},"DOI":"10.1007\/s00586-025-08701-7","type":"journal-article","created":{"date-parts":[[2025,2,3]],"date-time":"2025-02-03T03:04:36Z","timestamp":1738551876000},"page":"1495-1504","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Clinical MR imaging of patients with spinal hardware at 0.55T: comparison of diagnostic assessment and metal artifact appearance with 1.5T"],"prefix":"10.1007","volume":"34","author":[{"given":"Lauren J.","family":"Kelsey","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicole","family":"Seiberlich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jayapalli","family":"Bapuraj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Rivas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Masotti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vikas","family":"Gulani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7384-009X","authenticated-orcid":false,"given":"Shruti","family":"Mishra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,2,3]]},"reference":[{"issue":"16 Suppl","key":"8701_CR1","doi-asserted-by":"publisher","first-page":"S2","DOI":"10.1097\/01.brs.0000174509.31291.26","volume":"30","author":"NC Bambakidis","year":"2005","unstructured":"Bambakidis NC, Feiz-Erfan I, Klopfenstein JD et al (2005) Indications for surgical fusion of the cervical and lumbar motion segment. Spine (Phila Pa 1976) 30(16 Suppl):S2\u2013S6. https:\/\/doi.org\/10.1097\/01.brs.0000174509.31291.26","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"8701_CR2","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1177\/21925682221094267","volume":"14","author":"H Koshimizu","year":"2024","unstructured":"Koshimizu H, Nakashima H, Ohara T et al (2024) Implant-related complications after spinal Fusion: a Multicenter Study. Global Spine J 14(1):74\u201381. https:\/\/doi.org\/10.1177\/21925682221094267","journal-title":"Global Spine J"},{"key":"8701_CR3","doi-asserted-by":"publisher","first-page":"9940001","DOI":"10.1155\/2021\/9940001","volume":"2021","author":"R Corona-Cedillo","year":"2021","unstructured":"Corona-Cedillo R, Saavedra-Navarrete MT, Espinoza-Garcia JJ et al (2021) Imaging Assessment of the postoperative spine: an updated pictorial review of selected complications. Biomed Res Int 2021:9940001 Published 2021 May 18. https:\/\/doi.org\/10.1155\/2021\/9940001","journal-title":"Biomed Res Int"},{"issue":"4","key":"8701_CR4","doi-asserted-by":"publisher","first-page":"972","DOI":"10.1002\/jmri.25708","volume":"46","author":"PM Jungmann","year":"2017","unstructured":"Jungmann PM, Agten CA, Pfirrmann CW et al (2017) Advances in MRI around metal. J Magn Reson Imaging 46(4):972\u2013991. https:\/\/doi.org\/10.1002\/jmri.25708","journal-title":"J Magn Reson Imaging"},{"issue":"6","key":"8701_CR5","doi-asserted-by":"publisher","first-page":"1646","DOI":"10.1002\/jmri.27194","volume":"53","author":"L Winter","year":"2021","unstructured":"Winter L, Seifert F, Zilberti L et al (2021) MRI-Related heating of implants and devices: a review. J Magn Reson Imaging 53(6):1646\u20131665. https:\/\/doi.org\/10.1002\/jmri.27194","journal-title":"J Magn Reson Imaging"},{"issue":"5","key":"8701_CR6","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1007\/s00117-022-00986-9","volume":"62","author":"J Vosshenrich","year":"2022","unstructured":"Vosshenrich J, Breit HC, Bach M et al (2022) \u00d6konomische Aspekte Der Niederfeld-Magnetresonanztomographie: Anschaffung, installation und Unterhaltskosten Von 0,55 T-Ger\u00e4ten [Economic aspects of low-field magnetic resonance imaging : Acquisition, installation, and maintenance costs of 0.55 T systems]. Radiologe 62(5):400\u2013404. https:\/\/doi.org\/10.1007\/s00117-022-00986-9","journal-title":"Radiologe"},{"issue":"22","key":"8701_CR7","doi-asserted-by":"publisher","first-page":"6705","DOI":"10.3390\/jcm11226705","volume":"11","author":"T Rusche","year":"2022","unstructured":"Rusche T, Vosshenrich J, Winkel DJ et al (2022) More space, less noise-new-generation low-field magnetic resonance Imaging systems can improve patient comfort: a prospective 0.55T-1.5T-Scanner comparison. J Clin Med 11(22):6705 Published 2022 Nov 12. https:\/\/doi.org\/10.3390\/jcm11226705","journal-title":"J Clin Med"},{"issue":"4","key":"8701_CR8","doi-asserted-by":"publisher","first-page":"E126","DOI":"10.1148\/rg.2021200092","volume":"41","author":"EM Lee","year":"2021","unstructured":"Lee EM, Ibrahim EH, Dudek N et al (2021) Improving MR Image Quality in patients with metallic implants. Radiographics 41(4):E126\u2013E137. https:\/\/doi.org\/10.1148\/rg.2021200092","journal-title":"Radiographics"},{"issue":"1","key":"8701_CR9","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1186\/s41747-023-00320-5","volume":"7","author":"HC Breit","year":"2023","unstructured":"Breit HC, Vosshenrich J, Clauss M et al (2023) Visual and quantitative assessment of hip implant-related metal artifacts at low field MRI: a phantom study comparing a 0.55-T system with 1.5-T and 3-T systems. Eur Radiol Exp 7(1):5 Published 2023 Feb 8. https:\/\/doi.org\/10.1186\/s41747-023-00320-5","journal-title":"Eur Radiol Exp"},{"key":"8701_CR10","doi-asserted-by":"publisher","unstructured":"Seifert AC, Breit HC, Schlicht F, Donners R, Harder D, Vosshenrich J (2024) Comparing metal artifact severity and ability to assess near-metal anatomy between 0.55\u202fT and 1.5\u202fT MRI in patients with metallic spinal implants-a scanner comparison study. Acad Radiol 31(6):2456\u20132463. https:\/\/doi.org\/10.1016\/j.acra.2023.12.048. Epub 2024 Jan 18. PMID: 38242732","DOI":"10.1016\/j.acra.2023.12.048"},{"issue":"3","key":"8701_CR11","doi-asserted-by":"publisher","first-page":"276","DOI":"10.11613\/BM.2012.031","volume":"22","author":"ML McHugh","year":"2012","unstructured":"McHugh ML (2012) Interrater reliability: the kappa statistic. Biochem Med (Zagreb) 22(3):276\u2013282","journal-title":"Biochem Med (Zagreb)"},{"issue":"11","key":"8701_CR12","doi-asserted-by":"publisher","first-page":"2440","DOI":"10.1016\/j.acra.2023.01.037","volume":"30","author":"HC Breit","year":"2023","unstructured":"Breit HC, Vosshenrich J, Hofmann V et al (2023) Image Quality of Lumbar Spine Imaging at 0.55T low-field MRI is comparable to conventional 1.5T MRI - initial observations in healthy volunteers. Acad Radiol 30(11):2440\u20132446. https:\/\/doi.org\/10.1016\/j.acra.2023.01.037","journal-title":"Acad Radiol"},{"key":"8701_CR13","doi-asserted-by":"publisher","first-page":"111406","DOI":"10.1016\/j.ejrad.2024.111406","volume":"175","author":"A Lavrova","year":"2024","unstructured":"Lavrova A, Seiberlich N, Kelsey L et al (2024) Comparison of image quality and diagnostic efficacy of routine clinical lumbar spine imaging at 0.55 T and 1.5\/3T. Eur J Radiol 175:111406","journal-title":"Eur J Radiol"},{"issue":"12","key":"8701_CR14","doi-asserted-by":"publisher","first-page":"5772","DOI":"10.1007\/s00261-021-03234-1","volume":"46","author":"H Chandarana","year":"2021","unstructured":"Chandarana H, Bagga B, Huang C et al (2021) Diagnostic abdominal MR imaging on a prototype low-field 0.55 T scanner operating at two different gradient strengths. Abdom Radiol (NY) 46(12):5772\u20135780. https:\/\/doi.org\/10.1007\/s00261-021-03234-1","journal-title":"Abdom Radiol (NY)"},{"key":"8701_CR15","doi-asserted-by":"publisher","unstructured":"Lavrova A, Mishra S, Richardson J et al (2023) Quality assessment of routine brain imaging at 0.55 T: initial experience in a clinical workflow. NMR Biomed Published Online August 31. https:\/\/doi.org\/10.1002\/nbm.5017","DOI":"10.1002\/nbm.5017"},{"issue":"8","key":"8701_CR16","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1097\/RLI.0000000000000866","volume":"57","author":"I Khodarahmi","year":"2022","unstructured":"Khodarahmi I, Brinkmann IM, Lin DJ et al (2022) New-Generation Low-Field magnetic resonance imaging of hip arthroplasty implants using slice encoding for metal artifact correction: first in Vitro Experience at 0.55 T and comparison with 1.5 T. Invest Radiol 57(8):517\u2013526. https:\/\/doi.org\/10.1097\/RLI.0000000000000866","journal-title":"Invest Radiol"},{"key":"8701_CR17","doi-asserted-by":"publisher","first-page":"100567","DOI":"10.1016\/j.ejro.2024.100567","volume":"12","author":"F Schlicht","year":"2024","unstructured":"Schlicht F, Vosshenrich J, Donners R et al (2024) Advanced deep learning-based image reconstruction in lumbar spine MRI at 0.55 T\u2013Effects on image quality and acquisition time in comparison to conventional deep learning-based reconstruction. Eur J Radiol Open 12:100567","journal-title":"Eur J Radiol Open"},{"issue":"4","key":"8701_CR18","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1002\/jmri.22313","volume":"32","author":"KM Koch","year":"2010","unstructured":"Koch KM, Hargreaves BA, Pauly KB et al (2010) Magnetic resonance imaging near metal implants. J Magn Reson Imaging 32(4):773\u2013787","journal-title":"J Magn Reson Imaging"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-08701-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-025-08701-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-08701-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,15]],"date-time":"2025-04-15T16:04:13Z","timestamp":1744733053000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-025-08701-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,3]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["8701"],"URL":"https:\/\/doi.org\/10.1007\/s00586-025-08701-7","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,3]]},"assertion":[{"value":"18 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 December 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 January 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 February 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Authors Nicole Seiberlich and Vikas Gulani receive research support from Siemens Healthineers.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}