{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T13:50:21Z","timestamp":1775137821725,"version":"3.50.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,3,2]],"date-time":"2025-03-02T00:00:00Z","timestamp":1740873600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,3,2]],"date-time":"2025-03-02T00:00:00Z","timestamp":1740873600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2025,4]]},"DOI":"10.1007\/s00586-025-08753-9","type":"journal-article","created":{"date-parts":[[2025,3,2]],"date-time":"2025-03-02T18:35:51Z","timestamp":1740940551000},"page":"1275-1283","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A surgeon-controlled mode of robotic assistance with posterolateral approach helps achieve highly medialized cervical pedicle screw placement to avoid vertebral artery injury"],"prefix":"10.1007","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3424-4463","authenticated-orcid":false,"given":"Yoichi","family":"Tani","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuhiro","family":"Naka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoto","family":"Ono","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koki","family":"Kawashima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masaaki","family":"Paku","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masayuki","family":"Ishihara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Adachi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinichirou","family":"Taniguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Muneharu","family":"Ando","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takanori","family":"Saito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,3,2]]},"reference":[{"issue":"8","key":"8753_CR1","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1097\/00007632-199108000-00001","volume":"16","author":"MM Panjabi","year":"1991","unstructured":"Panjabi MM, Duranceau J, Goel V, Oxland T, Takata K (1991) Cervical human vertebrae: quantitative three-dimensional anatomy of the middle and lower regions. Spine 16(8):861\u2013869","journal-title":"Spine"},{"key":"8753_CR2","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1097\/00007632-199703010-00005","volume":"22","author":"EE Karaikovic","year":"1997","unstructured":"Karaikovic EE, Daubs MD, Madsen RW, Gaines RW (1997) Morphologic characteristics of human cervical pedicles. Spine 22:493\u2013500","journal-title":"Spine"},{"key":"8753_CR3","doi-asserted-by":"publisher","first-page":"2510","DOI":"10.1097\/01.brs.0000144404.68486.85","volume":"22","author":"T Sakamoto","year":"2004","unstructured":"Sakamoto T, Neo M, Nakamura T (2004) Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle. Spine 22:2510\u20132514","journal-title":"Spine"},{"issue":"8","key":"8753_CR4","first-page":"53","volume":"46","author":"N Habib","year":"2020","unstructured":"Habib N, Filardo G, Distefano D, Candrian C, Reinert M, Scarone P (2020) Use of intraoperative CT improves accuracy of spinal navigation during screw fixation in cervico-thoracic region. Spine 46(8):53\u2013537","journal-title":"Spine"},{"issue":"S2","key":"8753_CR5","doi-asserted-by":"publisher","first-page":"S8","DOI":"10.14444\/8271","volume":"16","author":"D Coric","year":"2022","unstructured":"Coric D, Rossi V (2022) Navigated, percutaneous posterior cervical minimally invasive surgery fixation: technique and nuances. Int J Spine Surg 16(S2):S8\u2013S13","journal-title":"Int J Spine Surg"},{"issue":"9","key":"8753_CR6","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1097\/00007632-199705010-00009","volume":"22","author":"EL Jones","year":"1997","unstructured":"Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws: anatomical feasibility and biomechanical comparison. Spine 22(9):977\u2013982","journal-title":"Spine"},{"issue":"13","key":"8753_CR7","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1097\/BRS.0000000000004357","volume":"47","author":"DC Perfetti","year":"2022","unstructured":"Perfetti DC, Kisinde S, Rogers-LaVanne MP, Satin AM, Lieberman IH (2022) Robotic spine surgery: past, present, and future. Spine 47(13):909\u2013921","journal-title":"Spine"},{"issue":"6","key":"8753_CR8","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1007\/s00586-011-1775-9","volume":"20","author":"C Schaefer","year":"2011","unstructured":"Schaefer C, Begemann P, Fuhrhop I, Schroeder M, Viezens L, Wiesner L, Hansen-Algenstaedt N (2011) Percutaneous instrumentation of thecervical and cervico-thoracic spine using pedicle screws: preliminary clinical results and analysis of accuracy. Eur Spine J 20(6):977\u2013985","journal-title":"Eur Spine J"},{"key":"8753_CR9","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1007\/s00586-015-4194-5","volume":"25","author":"SR Kantelhardt","year":"2016","unstructured":"Kantelhardt SR, Keric N, Conrad J, Archavilis E (2016) Minmally invasive instrumentation of uncomplicated cervical fractures. Eur Spine J 25:127\u2013133","journal-title":"Eur Spine J"},{"issue":"10","key":"8753_CR10","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1097\/BSD.0000000000000421","volume":"30","author":"T Komatsubara","year":"2017","unstructured":"Komatsubara T, Tokioka T, Sugimoto Y, Ozaki T (2017) Minimally invasive cervical pedicle screw fixation by a posterolateral approach for acute cervical injury. Clin Spine Surg 30(10):466\u2013469","journal-title":"Clin Spine Surg"},{"issue":"7","key":"8753_CR11","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1097\/BSD.0000000000000832","volume":"32","author":"T Tokioka","year":"2019","unstructured":"Tokioka T, Oda Y (2019) Minimally invasive cervical pedicle screw fixation (MICEPS) via a posterolateral approach. Clin Spine Surg 32(7):279\u2013284","journal-title":"Clin Spine Surg"},{"issue":"s3","key":"8753_CR12","doi-asserted-by":"publisher","first-page":"S14","DOI":"10.14444\/7122","volume":"14","author":"D Coric","year":"2020","unstructured":"Coric D, Rossi VJ, Peloza J, Kim PK, Adamson TE (2020) Percutaneous, navigated minimally invasive posterior cervical pedicle screw fixation. Int J Spine Surg 14(s3):S14\u2013S21","journal-title":"Int J Spine Surg"},{"issue":"2S","key":"8753_CR13","doi-asserted-by":"publisher","first-page":"27S","DOI":"10.1177\/21925682211029215","volume":"12","author":"D Coric","year":"2022","unstructured":"Coric D, Rossi V (2022) Percutaneous posterior cervical pedicle instrumentation (C1 to C7) with navigation guidance: early series of 27 cases. Glob Spine J 12(2S):27S-33S","journal-title":"Glob Spine J"},{"key":"8753_CR14","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/s11701-019-00963-w","volume":"14","author":"N Crawford","year":"2020","unstructured":"Crawford N, Johnson N, Theodore N (2020) Ensuring navigation integrity using robotics in spine surgery. J Robot Surg 14:177\u2013183","journal-title":"J Robot Surg"},{"key":"8753_CR15","doi-asserted-by":"publisher","first-page":"5725","DOI":"10.3390\/jcm10245725","volume":"10","author":"M Pojski\u0107","year":"2021","unstructured":"Pojski\u0107 M, Bopp M, Nimsky C, Carl B, Sa\u03b2 B (2021) Initial intraoperative experience with robotic-assisted pedicle screw placement with Cirq\u00ae robotic alignment: an evaluation of the first 70 screws. J Clin Med 10:5725","journal-title":"J Clin Med"},{"key":"8753_CR16","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1007\/s11701-021-01313-5","volume":"16","author":"K Chesney","year":"2022","unstructured":"Chesney K, Triano M, Dowlati E, Zhang I, Felbaum DR, Aulisi EF (2022) Cirq robotic arm-assisted transpedicular instrumentation with intraoperative navigation: technical note and case series with 714 thoracolumbar screws. J Robot Surg 16:893\u2013898","journal-title":"J Robot Surg"},{"key":"8753_CR17","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1186\/s12893-022-01878-4","volume":"22","author":"SK Desai","year":"2022","unstructured":"Desai SK, Adams JP (2022) Initial single surgeon evaluation comparing C-arm fluoroscopy with the Cirq robotic assistance device for instrumentation of the thoracolumbar spine. BMC Surg 22:434","journal-title":"BMC Surg"},{"key":"8753_CR18","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1093\/ons\/opaa208","volume":"19","author":"K Farah","year":"2020","unstructured":"Farah K, Meyer M, Prost S, Dufour H, Blondel B, Fuentes S (2020) Cirq\u00ae robotic assistance for minimally invasive C1\u2013C2 posterior instrumentation: report on feasibility and safety. Oper Neurosurg 19:730\u2013734","journal-title":"Oper Neurosurg"},{"key":"8753_CR19","doi-asserted-by":"publisher","first-page":"e777","DOI":"10.1016\/j.wneu.2021.03.150","volume":"150","author":"K Farah","year":"2021","unstructured":"Farah K, Meyer M, Prost S, Albader F, Dufour H, Blondel B, Fuentes S (2021) Robotic assistance for minimally invasive cervical pedicle instrumentation: report on feasibility and safety. World Neurosurg 150:e777\u2013e782","journal-title":"World Neurosurg"},{"issue":"7","key":"8753_CR20","doi-asserted-by":"publisher","first-page":"2294","DOI":"10.1007\/s00586-016-4555-8","volume":"25","author":"M Koda","year":"2016","unstructured":"Koda M, Mochizuki M, Konishi H, Aiba A, Kadota R, Inada T, Kamiya K, Ota M, Maki S, Takahashi K, Yamazaki M, Mannoji C, Furuya T (2016) Comparison of clinical outcomes between laminoplasty, posterior decompression with instrumented fusion, and anterior decompression with fusion for K-line (-) cervical ossification of the posterior longitudinal ligament. Eur Spine J 25(7):2294\u20132301","journal-title":"Eur Spine J"},{"issue":"24","key":"8753_CR21","doi-asserted-by":"publisher","first-page":"2800","DOI":"10.1097\/01.brs.0000192297.07709.5d","volume":"30","author":"M Neo","year":"2005","unstructured":"Neo M, Sakamoto T, Fujibayashi S, Nakamura T (2005) The clinical risk of vertebral artery injury from cervical Pedicle screws inserted in degenerative vertebrae. Spine 30(24):2800\u20132805","journal-title":"Spine"},{"key":"8753_CR22","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1007\/s00586-022-07110-4","volume":"31","author":"S Kisinde","year":"2022","unstructured":"Kisinde S, Hu X, Hesselbacher S, Satin AM, Lieberman IH (2022) Robotic-guided placement of cervical pedicle screws: feasibility and accuracy. Eur Spine J 31:693\u2013701","journal-title":"Eur Spine J"},{"issue":"1","key":"8753_CR23","doi-asserted-by":"publisher","first-page":"E7","DOI":"10.3171\/2021.10.FOCUS21467","volume":"52","author":"P Kendlbacher","year":"2022","unstructured":"Kendlbacher P, Tkatschenko D, Czabanka M, Bayerl S, Bohner G, Woitzik J, Vajkoczy P, Hecht N (2022) Workflow and performance of intraoperative CT, cone-beam CT, and robotic cone-beam CT for spinal navigation in 503 consecutive patients. Neurosurg Focus 52(1):E7","journal-title":"Neurosurg Focus"},{"issue":"3","key":"8753_CR24","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1097\/00002517-199407030-00004","volume":"7","author":"B Jeanneret","year":"1994","unstructured":"Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7(3):222\u2013229","journal-title":"J Spinal Disord"},{"key":"8753_CR25","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1007\/s43390-020-00119-z","volume":"8","author":"HWD Hey","year":"2020","unstructured":"Hey HWD, Zhuo W-H, Tan YHJ, Tan JH (2020) Accuracy of freehand pedicle screws versus lateral mass screws in the subaxial cervical spine. Spine Deformity 8:1049\u20131058","journal-title":"Spine Deformity"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-08753-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-025-08753-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-08753-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,15]],"date-time":"2025-04-15T03:55:51Z","timestamp":1744689351000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-025-08753-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,2]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["8753"],"URL":"https:\/\/doi.org\/10.1007\/s00586-025-08753-9","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,2]]},"assertion":[{"value":"4 September 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 January 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 February 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 March 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}