{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T17:36:07Z","timestamp":1773336967051,"version":"3.50.1"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2025,4,19]],"date-time":"2025-04-19T00:00:00Z","timestamp":1745020800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,4,19]],"date-time":"2025-04-19T00:00:00Z","timestamp":1745020800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/100015013","name":"Florida Department of State","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100015013","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Foundation Surgical Group"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2025,6]]},"DOI":"10.1007\/s00586-025-08871-4","type":"journal-article","created":{"date-parts":[[2025,4,19]],"date-time":"2025-04-19T08:16:22Z","timestamp":1745050582000},"page":"2467-2477","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Biomechanical preservation of lumbar spine stability and motion with an intraosseous implant following vertebral body osteotomy"],"prefix":"10.1007","volume":"34","author":[{"given":"Nathan D.","family":"Schilaty","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katherine F.","family":"Walters","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Schuyler Van Den","family":"Nieuwenhuizen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nathaniel A.","family":"Bates","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adolfo Viloria","family":"Hidalgo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Puya","family":"Alikhani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,19]]},"reference":[{"key":"8871_CR1","doi-asserted-by":"publisher","first-page":"e316","DOI":"10.1016\/S2665-9913(23)00098-X","volume":"5","author":"ML Ferreira","year":"2023","unstructured":"Ferreira ML, de Luca K, Haile LM et al (2023) Global, regional, and National burden of low back pain, 1990\u20132020, its attributable risk factors, and projections to 2050: a systematic analysis of the global burden of disease study 2021. Lancet Rheumatol 5:e316\u2013e329. https:\/\/doi.org\/10.1016\/S2665-9913(23)00098-X","journal-title":"Lancet Rheumatol"},{"key":"8871_CR2","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1302\/2058-5241.2.160069","volume":"2","author":"KC Kose","year":"2017","unstructured":"Kose KC, Bozduman O, Yenigul AE, Igrek S (2017) Spinal osteotomies: indications, limits and pitfalls. EFORT Open Rev 2:73\u201382. https:\/\/doi.org\/10.1302\/2058-5241.2.160069","journal-title":"EFORT Open Rev"},{"key":"8871_CR3","doi-asserted-by":"publisher","unstructured":"Mobbs RJ, Phan K, Malham G Lumbar interbody fusion: techniques, indications and comparison of interbody fusion options including PLIF, TLIF, MI-TLIF et al (2015) OLIF\/ATP, LLIF and ALIF. J Spine Surg 1:2\u201318. https:\/\/doi.org\/10.3978\/j.issn.2414-469X.2015.10.05","DOI":"10.3978\/j.issn.2414-469X.2015.10.05"},{"key":"8871_CR4","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1007\/s12178-017-9397-4","volume":"10","author":"SN Salzmann","year":"2017","unstructured":"Salzmann SN, Plais N, Shue J, Girardi FP (2017) Lumbar disc replacement surgery\u2014successes and Obstacles to widespread adoption. Curr Rev Musculoskelet Med 10:153\u2013159","journal-title":"Curr Rev Musculoskelet Med"},{"key":"8871_CR5","doi-asserted-by":"publisher","unstructured":"Shin JJ, Kim KR, Son DW et al (2021) Cervical disc arthroplasty: what we know in 2020 and a literature review. J Orthop Surg 29. https:\/\/doi.org\/10.1177\/23094990211006934","DOI":"10.1177\/23094990211006934"},{"key":"8871_CR6","doi-asserted-by":"publisher","first-page":"216","DOI":"10.4103\/2152-7806.98582","volume":"3","author":"B Tortolani Pj, Moatz","year":"2012","unstructured":"Tortolani Pj, Moatz B (2012) Cervical disc arthroplasty: pros and cons. Surg Neurol Int 3:216. https:\/\/doi.org\/10.4103\/2152-7806.98582","journal-title":"Surg Neurol Int"},{"key":"8871_CR7","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2004.07.007","author":"AS Hilibrand","year":"2004","unstructured":"Hilibrand AS, Robbins M (2004) Adjacent segment degeneration and adjacent segment disease: the consequences of spinal fusion? Spine J. https:\/\/doi.org\/10.1016\/j.spinee.2004.07.007. 4:","journal-title":"Spine J"},{"key":"8871_CR8","doi-asserted-by":"publisher","first-page":"2509","DOI":"10.2106\/JBJS.H.00081","volume":"90","author":"JB Gill","year":"2008","unstructured":"Gill JB, Levin A, Burd T, Longley M (2008) Corrective osteotomies in spine surgery. J Bone Joint Surg 90:2509\u20132520. https:\/\/doi.org\/10.2106\/JBJS.H.00081","journal-title":"J Bone Joint Surg"},{"key":"8871_CR9","unstructured":"Alejandra Gonzalez Blohm S (2012) Biomechanical Testing on Cadaveric Spines for Different Treatments that Affect Lumbar Stability. Thesis, University of South Florida"},{"key":"8871_CR10","doi-asserted-by":"publisher","unstructured":"Lai O, Chen Y, Chen Q et al (2021) Cadaveric Biomechanical analysis of multilevel lateral lumbar interbody fusion with and without supplemental instrumentation. BMC Musculoskelet Disord 22. https:\/\/doi.org\/10.1186\/s12891-021-04151-6","DOI":"10.1186\/s12891-021-04151-6"},{"key":"8871_CR11","doi-asserted-by":"publisher","first-page":"2194","DOI":"10.1002\/jbmr.428","volume":"26","author":"PJ Pickhardt","year":"2011","unstructured":"Pickhardt PJ, Lee LJ, Del Mu\u00f1oz A et al (2011) Simultaneous screening for osteoporosis at CT colonography: bone mineral density assessment using MDCT Attenuation techniques compared with the DXA reference standard. J Bone Miner Res 26:2194\u20132203. https:\/\/doi.org\/10.1002\/jbmr.428","journal-title":"J Bone Miner Res"},{"key":"8871_CR12","first-page":"25","volume":"38","author":"NR Hendrickson","year":"2018","unstructured":"Hendrickson NR, Pickhardt PJ, Del Rio AM et al (2018) Bone mineral density T-Scores derived from CT Attenuation numbers (Hounsfield Units): Clinical Utility and Correlation with Dual-energy X-ray Absorptiometry. Iowa Orthop J 38:25\u201331","journal-title":"Iowa Orthop J"},{"key":"8871_CR13","doi-asserted-by":"publisher","first-page":"e418","DOI":"10.1016\/j.wneu.2021.04.051","volume":"151","author":"T Elarjani","year":"2021","unstructured":"Elarjani T, Warner T, Nguyen K et al (2021) Quantifying bone quality using computed tomography Hounsfield units in the Mid-sagittal view of the lumbar spine. World Neurosurg 151:e418\u2013e425. https:\/\/doi.org\/10.1016\/j.wneu.2021.04.051","journal-title":"World Neurosurg"},{"key":"8871_CR14","doi-asserted-by":"publisher","first-page":"1272","DOI":"10.1016\/j.spinee.2013.11.037","volume":"14","author":"JJ Doulgeris","year":"2014","unstructured":"Doulgeris JJ, Gonzalez-Blohm SA, Aghayev K et al (2014) Axial rotation mechanics in a cadaveric lumbar spine model: A Biomechanical analysis. Spine J 14:1272\u20131279. https:\/\/doi.org\/10.1016\/j.spinee.2013.11.037","journal-title":"Spine J"},{"key":"8871_CR15","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1007\/s00586-007-0487-7","volume":"17","author":"S Milosavljevic","year":"2008","unstructured":"Milosavljevic S, Pal P, Bain D, Johnson G (2008) Kinematic and Temporal interactions of the lumbar spine and hip during trunk extension in healthy male subjects. Eur Spine J 17:122\u2013128. https:\/\/doi.org\/10.1007\/s00586-007-0487-7","journal-title":"Eur Spine J"},{"key":"8871_CR16","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1097\/00007632-198101000-00020","volume":"6","author":"AL Nachemson","year":"1981","unstructured":"Nachemson AL (1981) Disc pressure measurements. Spine (Phila Pa 1976) 6:93\u201397","journal-title":"Spine (Phila Pa 1976)"},{"key":"8871_CR17","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1097\/00007632-199904150-00005","volume":"24","author":"H-J Wilke","year":"1999","unstructured":"Wilke H-J, Neef P, Caimi M et al (1999) New in vivo measurements of pressures in the intervertebral disc in daily life. Spine (Phila Pa 1976) 24:755\u2013762","journal-title":"Spine (Phila Pa 1976)"},{"key":"8871_CR18","doi-asserted-by":"publisher","first-page":"1298","DOI":"10.1007\/s00464-008-0154-z","volume":"23","author":"Y-J Lim","year":"2009","unstructured":"Lim Y-J, Deo D, Singh TP et al (2009) In situ measurement and modeling of Biomechanical response of human cadaveric soft tissues for physics-based surgical simulation. Surg Endosc 23:1298\u20131307. https:\/\/doi.org\/10.1007\/s00464-008-0154-z","journal-title":"Surg Endosc"},{"key":"8871_CR19","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.jbiomech.2012.10.014","volume":"46","author":"A Bisschop","year":"2013","unstructured":"Bisschop A, Kingma I, Bleys RLAW et al (2013) Effects of repetitive movement on range of motion and stiffness around the neutral orientation of the human lumbar spine. J Biomech 46:187\u2013191. https:\/\/doi.org\/10.1016\/j.jbiomech.2012.10.014","journal-title":"J Biomech"},{"key":"8871_CR20","doi-asserted-by":"publisher","first-page":"113","DOI":"10.4274\/jtss.galenos.2023.33042","volume":"34","author":"A Apti","year":"2023","unstructured":"Apti A, \u00c7olak TK, Ak\u00e7ay B (2023) Normative values for cervical and lumbar range of motion in healthy young adults. J Turkish Spinal Surg 34:113\u2013117. https:\/\/doi.org\/10.4274\/jtss.galenos.2023.33042","journal-title":"J Turkish Spinal Surg"},{"key":"8871_CR21","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1227\/00006123-198007000-00014","volume":"7","author":"MM Panjabi","year":"1980","unstructured":"Panjabi MM, White AA (1980) Basic biomechanics of the spine. Neurosurgery 7:76\u201393","journal-title":"Neurosurgery"},{"key":"8871_CR22","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-020-02562-5","author":"ND Schilaty","year":"2020","unstructured":"Schilaty ND, Bates NA, Ueno R, Hewett TE (2020) Ann Biomed Eng 49:334\u2013344. https:\/\/doi.org\/10.1007\/s10439-020-02562-5. Data Filtration of Mechanical Impact Simulator Data: Characterization of Signal from Artefact"},{"key":"8871_CR23","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1016\/j.otsr.2010.01.006","volume":"96","author":"B Ilharreborde","year":"2010","unstructured":"Ilharreborde B, Zhao K, Boumediene E et al (2010) A dynamic method for in vitro multisegment spine testing. Orthop Traumatology: Surg Res 96:456\u2013461. https:\/\/doi.org\/10.1016\/j.otsr.2010.01.006","journal-title":"Orthop Traumatology: Surg Res"},{"key":"8871_CR24","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/s00586-010-1641-1","volume":"20","author":"B Ilharreborde","year":"2011","unstructured":"Ilharreborde B, Shaw MN, Berglund LJ et al (2011) Biomechanical evaluation of posterior lumbar dynamic stabilization: an in vitro comparison between universal clamp and Wallis systems. Eur Spine J 20:289\u2013296. https:\/\/doi.org\/10.1007\/s00586-010-1641-1","journal-title":"Eur Spine J"},{"key":"8871_CR25","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1016\/j.clinbiomech.2014.10.003","volume":"30","author":"JJ Doulgeris","year":"2015","unstructured":"Doulgeris JJ, Aghayev K, Gonzalez-Blohm SA et al (2015) Biomechanical comparison of an interspinous fusion device and bilateral pedicle screw system as additional fixation for lateral lumbar interbody fusion. Clin Biomech Elsevier Ltd 30:205\u2013210. https:\/\/doi.org\/10.1016\/j.clinbiomech.2014.10.003","journal-title":"Clin Biomech Elsevier Ltd"},{"key":"8871_CR26","doi-asserted-by":"publisher","first-page":"S55","DOI":"10.1080\/15389588.2023.2198627","volume":"24","author":"K Chastain","year":"2023","unstructured":"Chastain K, Gepner B, Moreau D et al (2023) Effect of axial compression on stiffness and deformation of human lumbar spine in flexion-extension. Traffic Inj Prev 24:S55\u2013S61. https:\/\/doi.org\/10.1080\/15389588.2023.2198627","journal-title":"Traffic Inj Prev"},{"key":"8871_CR27","doi-asserted-by":"publisher","first-page":"2143","DOI":"10.1177\/0363546519854286","volume":"47","author":"ND Schilaty","year":"2019","unstructured":"Schilaty ND, Bates NA, Krych AJ, Hewett TE (2019) Frontal plane medial collateral ligament strain characteristics concurrent to anterior cruciate ligament failure. Am J Sports Med 47:2143\u20132150","journal-title":"Am J Sports Med"},{"key":"8871_CR28","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1007\/s10439-005-1742-x","volume":"33","author":"JS Little","year":"2005","unstructured":"Little JS, Khalsa PS (2005) Human lumbar spine creep during Cyclic and static flexion: creep rate, biomechanics, and facet joint capsule strain. Ann Biomed Eng 33:391\u2013401","journal-title":"Ann Biomed Eng"},{"key":"8871_CR29","doi-asserted-by":"publisher","first-page":"e98510","DOI":"10.1371\/JOURNAL.PONE.0098510","volume":"9","author":"A Rohlmann","year":"2014","unstructured":"Rohlmann A, Pohl D, Bender A et al (2014) Activities of everyday life with high spinal loads. PLoS ONE 9:e98510. https:\/\/doi.org\/10.1371\/JOURNAL.PONE.0098510","journal-title":"PLoS ONE"},{"key":"8871_CR30","doi-asserted-by":"publisher","unstructured":"Kim KJ, Kim DH, Lee J, Il et al (2019) Hounsfield units on lumbar computed tomography for predicting regional bone mineral density. Open Med (Wars) 14:545\u2013551. https:\/\/doi.org\/10.1515\/med-2019-0061","DOI":"10.1515\/med-2019-0061"},{"key":"8871_CR31","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1007\/S00586-020-06631-0\/FIGURES\/5","volume":"30","author":"E Beaucage-Gauvreau","year":"2021","unstructured":"Beaucage-Gauvreau E, Brandon SCE, Robertson WSP et al (2021) Lumbar spine loads are reduced for activities of daily living when using a braced arm-to-thigh technique. Eur Spine J 30:1035\u20131042. https:\/\/doi.org\/10.1007\/S00586-020-06631-0\/FIGURES\/5","journal-title":"Eur Spine J"},{"key":"8871_CR32","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1007\/s00586-016-4683-1","volume":"26","author":"IM Austevoll","year":"2017","unstructured":"Austevoll IM, Gjestad R, Brox JI et al (2017) The effectiveness of decompression alone compared with additional fusion for lumbar spinal stenosis with degenerative spondylolisthesis: a pragmatic comparative non-inferiority observational study from the Norwegian registry for spine surgery. Eur Spine J 26:404\u2013413. https:\/\/doi.org\/10.1007\/s00586-016-4683-1","journal-title":"Eur Spine J"},{"key":"8871_CR33","doi-asserted-by":"publisher","unstructured":"Klimov V, Evsyukov A, Amelina E et al (2022) Predictors of complications and unfavorable outcomes of minimally invasive surgery treatment in elderly patients with degenerative lumbar spine pathologies (Case Series). Front Surg 9. https:\/\/doi.org\/10.3389\/fsurg.2022.869345","DOI":"10.3389\/fsurg.2022.869345"},{"key":"8871_CR34","doi-asserted-by":"publisher","first-page":"1050","DOI":"10.1016\/J.BONE.2009.11.036","volume":"46","author":"J Luo","year":"2010","unstructured":"Luo J, Bertram W, Sangar D et al (2010) Is kyphoplasty better than vertebroplasty in restoring normal mechanical function to an injured spine? Bone 46:1050\u20131057. https:\/\/doi.org\/10.1016\/J.BONE.2009.11.036","journal-title":"Bone"},{"key":"8871_CR35","doi-asserted-by":"publisher","first-page":"e66247","DOI":"10.3791\/66247","volume":"203","author":"Y Wang","year":"2024","unstructured":"Wang Y, Shen Q, Liang C et al (2024) Biomechanical analysis of adjacent segments after spinal fusion surgery using a geometrically parametric Patient-Specific finite element model. J Visualized Experiments 203:e66247. https:\/\/doi.org\/10.3791\/66247","journal-title":"J Visualized Experiments"},{"key":"8871_CR36","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1097\/01.brs.0000150831.46856.87","volume":"30","author":"J Steinmann","year":"2005","unstructured":"Steinmann J, Tingey CT, Cruz G, Dai Q (2005) Biomechanical comparison of unipedicular versus bipedicular kyphoplasty. Spine (Phila Pa 1976) 30:201\u2013205","journal-title":"Spine (Phila Pa 1976)"},{"key":"8871_CR37","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1016\/J.SPINEE.2014.11.017","volume":"15","author":"PR Landham","year":"2015","unstructured":"Landham PR, Baker-Rand HLA, Gilbert SJ et al (2015) Is kyphoplasty better than vertebroplasty at restoring form and function after severe vertebral wedge fractures? Spine J 15:721\u2013732. https:\/\/doi.org\/10.1016\/J.SPINEE.2014.11.017","journal-title":"Spine J"},{"key":"8871_CR38","doi-asserted-by":"publisher","first-page":"1040695","DOI":"10.3389\/FBIOE.2022.1040695\/BIBTEX","volume":"10","author":"C Techens","year":"2022","unstructured":"Techens C, Montanari S, Bereczki F et al (2022) Biomechanical consequences of cement discoplasty: an in vitro study on thoraco-lumbar human spines. Front Bioeng Biotechnol 10:1040695. https:\/\/doi.org\/10.3389\/FBIOE.2022.1040695\/BIBTEX","journal-title":"Front Bioeng Biotechnol"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-08871-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-025-08871-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-08871-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T11:33:10Z","timestamp":1751369590000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-025-08871-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,19]]},"references-count":38,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["8871"],"URL":"https:\/\/doi.org\/10.1007\/s00586-025-08871-4","relation":{"references":[{"id-type":"doi","id":"10.1007\/s10439-020-02562-5","asserted-by":"subject"}]},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,19]]},"assertion":[{"value":"16 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 April 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 April 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 April 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}