{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T13:29:14Z","timestamp":1776950954159,"version":"3.51.4"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2025,6,13]],"date-time":"2025-06-13T00:00:00Z","timestamp":1749772800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,6,13]],"date-time":"2025-06-13T00:00:00Z","timestamp":1749772800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Jiangsu Provincial Medical Innovation Center of Orthopedic Surgery","award":["CXZX202214"],"award-info":[{"award-number":["CXZX202214"]}]},{"name":"Nanjing Medical Science and Technology Development Foundation","award":["ZKX22017"],"award-info":[{"award-number":["ZKX22017"]}]},{"name":"Clinical Trials from the Affiliated Drum Tower Hospital, Medical School of Nanjing University","award":["2022-LCYJ-MS-22"],"award-info":[{"award-number":["2022-LCYJ-MS-22"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2025,9]]},"DOI":"10.1007\/s00586-025-08972-0","type":"journal-article","created":{"date-parts":[[2025,6,13]],"date-time":"2025-06-13T09:28:15Z","timestamp":1749806895000},"page":"4073-4082","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Modeling optimal trajectory for tricortical pedicle screw fixation in adult thoracic spine: an imaging study using the three-dimensional reconstruction technique"],"prefix":"10.1007","volume":"34","author":[{"given":"Dongyue","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bangheng","family":"Liang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhen","family":"Jin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jie","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanjie","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhen","family":"Tian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yong","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zezhang","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhen","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,6,13]]},"reference":[{"key":"8972_CR1","doi-asserted-by":"publisher","first-page":"2726","DOI":"10.1007\/s00586-014-3531-4","volume":"23","author":"SK Cho","year":"2014","unstructured":"Cho SK, Shin JI, Kim YJ (2014) Proximal junctional kyphosis following adult spinal deformity surgery. Eur Spine J 23:2726\u20132736. https:\/\/doi.org\/10.1007\/s00586-014-3531-4","journal-title":"Eur Spine J"},{"key":"8972_CR2","doi-asserted-by":"publisher","first-page":"842","DOI":"10.1016\/j.spinee.2021.01.011","volume":"21","author":"RJP Doodkorte","year":"2021","unstructured":"Doodkorte RJP, Vercoulen TFG, Roth AK, de Bie RA, Willems PC (2021) Instrumentation techniques to prevent proximal junctional kyphosis and proximal junctional failure in adult spinal deformity correction-a systematic review of biomechanical studies. Spine J 21:842\u2013854. https:\/\/doi.org\/10.1016\/j.spinee.2021.01.011","journal-title":"Spine J"},{"issue":"22","key":"8972_CR3","doi-asserted-by":"publisher","first-page":"1693","DOI":"10.1097\/BRS.0000000000002209","volume":"42","author":"FH Nicholls","year":"2017","unstructured":"Nicholls FH, Bae J, Theologis AA, Eksi MS, Ames CP, Berven SH, Burch S, Tay BK, Deviren V (2017) Factors associated with the development of and revision for proximal junctional kyphosis in 440 consecutive adult spinal deformity patients. Spine 42(22):1693\u20131698. https:\/\/doi.org\/10.1097\/BRS.0000000000002209","journal-title":"Spine"},{"key":"8972_CR4","doi-asserted-by":"publisher","first-page":"26","DOI":"10.21037\/jss-20-622","volume":"7","author":"A Cazzulino","year":"2021","unstructured":"Cazzulino A, Gandhi R, Woodard T, Ackshota N, Janjua MB, Arlet V, Saifi C (2021) Soft Landing technique as a possible prevention strategy for proximal junctional failure following adult spinal deformity surgery. J Spine Surg 7:26\u201336. https:\/\/doi.org\/10.21037\/jss-20-622","journal-title":"J Spine Surg"},{"key":"8972_CR5","doi-asserted-by":"publisher","first-page":"622","DOI":"10.31616\/asj.2018.12.4.622","volume":"12","author":"A Matsumura","year":"2018","unstructured":"Matsumura A, Namikawa T, Kato M, Oyama S, Hori Y, Yabu A, Hidaka N, Nakamura H (2018) Effect of different types of upper instrumented vertebrae instruments on proximal junctional kyphosis following adult spinal deformity surgery: pedicle screw versus transverse process hook. Asian Spine J 12:622\u2013631. https:\/\/doi.org\/10.31616\/asj.2018.12.4.622","journal-title":"Asian Spine J"},{"key":"8972_CR6","doi-asserted-by":"publisher","first-page":"1287","DOI":"10.1007\/s00586-020-06291-0","volume":"29","author":"F Rodriguez-Fontan","year":"2020","unstructured":"Rodriguez-Fontan F, Reeves BJ, Noshchenko A, Ou-Yang D, Kleck CJ, Cain C, Burger-Van der Walt E, Patel VV (2020) Strap stabilization for proximal junctional kyphosis prevention in instrumented posterior spinal fusion. Eur Spine J 29:1287\u20131296. https:\/\/doi.org\/10.1007\/s00586-020-06291-0","journal-title":"Eur Spine J"},{"key":"8972_CR7","doi-asserted-by":"publisher","DOI":"10.3390\/medicina60060860","author":"Y Tani","year":"2024","unstructured":"Tani Y, Naka N, Ono N, Kawashima K, Paku M, Ishihara M, Adachi T, Ando M, Taniguchi S, Saito T (2024) can we rely on prophylactic two-level vertebral cement augmentation in long-segment adult spinal deformity surgery to reduce the incidence of proximal junctional complications? Medicina (Kaunas). https:\/\/doi.org\/10.3390\/medicina60060860","journal-title":"Medicina (Kaunas)"},{"key":"8972_CR8","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1177\/2192568219868472","volume":"10","author":"S Iyer","year":"2020","unstructured":"Iyer S, Lovecchio F, Elys\u00e9e JC, Lafage R, Steinhaus M, Schwab FJ, Lafage V, Kim HJ (2020) Posterior ligamentous reinforcement of the upper instrumented vertebrae +1 does not decrease proximal junctional kyphosis in adult spinal deformity. Global Spine J 10:692\u2013699. https:\/\/doi.org\/10.1177\/2192568219868472","journal-title":"Global Spine J"},{"issue":"4","key":"8972_CR9","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1097\/BRS.0000000000003765","volume":"46","author":"R Alluri","year":"2021","unstructured":"Alluri R, Kim A, Ton A, Kang H, Acosta F, Hah R (2021) Semitendinosus tendon augmentation for prevention of proximal junctional failure. Spine 46(4):241\u2013248. https:\/\/doi.org\/10.1097\/BRS.0000000000003765","journal-title":"Spine"},{"key":"8972_CR10","doi-asserted-by":"publisher","first-page":"e96","DOI":"10.1016\/j.wneu.2018.08.242","volume":"121","author":"TJ Buell","year":"2019","unstructured":"Buell TJ, Chen CJ, Quinn JC, Buchholz AL, Mazur MD, Mullin JP, Nguyen JH, Taylor DG, Bess S, Line BG, Ames CP, Schwab FJ, Lafage V, Shaffrey CI, Smith JS (2019) Alignment risk factors for proximal junctional kyphosis and the effect of lower thoracic junctional tethers for adult spinal deformity. World Neurosurg 121:e96\u2013e103. https:\/\/doi.org\/10.1016\/j.wneu.2018.08.242","journal-title":"World Neurosurg"},{"key":"8972_CR11","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1007\/s00586-014-3422-8","volume":"24","author":"Y Atici","year":"2015","unstructured":"Atici Y, Akman YE, Erdogan S, Sari S, Yavuz U, Carkci E, Kaygusuz MA (2015) The effect of growing rod lengthening technique on the sagittal spinal and the spinopelvic parameters. Eur Spine J 24:1148\u20131157. https:\/\/doi.org\/10.1007\/s00586-014-3422-8","journal-title":"Eur Spine J"},{"issue":"4","key":"8972_CR12","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1097\/BRS.0000000000003249","volume":"45","author":"BG Line","year":"2020","unstructured":"Line BG, Bess S, Lafage R, Lafage V, Schwab F, Ames C, Kim HJ, Kelly M, Gupta M, Burton D, Hart R, Klineberg E, Kebaish K, Hostin R, Mundis G, Eastlack R, Shaffrey C, Smith JS (2020) Effective prevention of proximal junctional failure in adult spinal deformity surgery requires a combination of surgical implant prophylaxis and avoidance of sagittal alignment overcorrection. Spine 45(4):258\u2013267. https:\/\/doi.org\/10.1097\/BRS.0000000000003249","journal-title":"Spine"},{"key":"8972_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2019.105035","volume":"187","author":"W Zhang","year":"2020","unstructured":"Zhang W, Zhao J, Li L, Yu C, Zhao Y, Si H (2020) Modelling tri-cortical pedicle screw fixation in thoracic vertebrae under osteoporotic condition: A finite element analysis based on computed tomography. Comput Methods Programs Biomed 187:105035. https:\/\/doi.org\/10.1016\/j.cmpb.2019.105035","journal-title":"Comput Methods Programs Biomed"},{"key":"8972_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2025.02.002","author":"Z Liu","year":"2025","unstructured":"Liu Z, Tang Z, Li J, Hu Z, Qin X, Shi B, Mao S, Qiu Y, Zhu Z (2025) Tri-cortical pedicle screw fixation in the most cranial instrumented segment to prevent proximal junctional kyphosis. Spine J. https:\/\/doi.org\/10.1016\/j.spinee.2025.02.002","journal-title":"Spine J"},{"key":"8972_CR15","doi-asserted-by":"publisher","first-page":"377","DOI":"10.4184\/asj.2016.10.2.377","volume":"10","author":"JA Iorio","year":"2016","unstructured":"Iorio JA, Jakoi AM, Singla A (2016) Biomechanics of degenerative spinal disorders. Asian Spine J 10:377\u2013384. https:\/\/doi.org\/10.4184\/asj.2016.10.2.377","journal-title":"Asian Spine J"},{"key":"8972_CR16","doi-asserted-by":"publisher","first-page":"3324","DOI":"10.1002\/jbm.a.34986","volume":"102","author":"U Chamoli","year":"2014","unstructured":"Chamoli U, Diwan AD, Tsafnat N (2014) Pedicle screw-based posterior dynamic stabilizers for degenerative spine: in vitro biomechanical testing and clinical outcomes. J Biomed Mater Res A 102:3324\u20133340. https:\/\/doi.org\/10.1002\/jbm.a.34986","journal-title":"J Biomed Mater Res A"},{"issue":"17","key":"8972_CR17","doi-asserted-by":"publisher","first-page":"E932","DOI":"10.1097\/BRS.0000000000004021","volume":"46","author":"K Oda","year":"2021","unstructured":"Oda K, Ohba T, Hiroshi Y, Fujita K, Tanaka N, Koyma K, Haro H (2021) Factors affecting pedicle screw insertional torque in spine deformity surgery. Spine 46(17):E932\u2013E938. https:\/\/doi.org\/10.1097\/BRS.0000000000004021","journal-title":"Spine"},{"key":"8972_CR18","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1007\/s00586-015-3768-6","volume":"24","author":"F Galbusera","year":"2015","unstructured":"Galbusera F, Volkheimer D, Reitmaier S, Berger-Roscher N, Kienle A, Wilke HJ (2015) Pedicle screw loosening: a clinically relevant complication? Eur Spine J 24:1005\u20131016. https:\/\/doi.org\/10.1007\/s00586-015-3768-6","journal-title":"Eur Spine J"},{"issue":"24","key":"8972_CR19","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1097\/BRS.0000000000002305","volume":"42","author":"M Uehara","year":"2017","unstructured":"Uehara M, Takahashi J, Ikegami S, Kuraishi S, Shimizu M, Futatsugi T, Oba H, Koseki M, Kato H (2017) Pedicle screw loosening after posterior spinal fusion for adolescent idiopathic scoliosis in upper and lower instrumented vertebrae having major perforation. Spine 42(24):1895\u20131900. https:\/\/doi.org\/10.1097\/BRS.0000000000002305","journal-title":"Spine"},{"issue":"20","key":"8972_CR20","doi-asserted-by":"publisher","first-page":"2179","DOI":"10.1097\/BRS.0b013e31817c0428","volume":"33","author":"YJ Kim","year":"2008","unstructured":"Kim YJ, Bridwell KH, Lenke LG, Glattes CR, Rhim S, Cheh G (2008) Proximal junctional kyphosis in adult spinal deformity after segmental posterior spinal instrumentation and fusion: minimum five-year follow-up. Spine 33(20):2179\u20132184. https:\/\/doi.org\/10.1097\/BRS.0b013e31817c0428","journal-title":"Spine"},{"key":"8972_CR21","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1016\/j.jspd.2013.05.008","volume":"1","author":"H Hassanzadeh","year":"2013","unstructured":"Hassanzadeh H, Gupta S, Jain A, El Dafrawy MH, Skolasky RL, Kebaish KM (2013) Type of anchor at the proximal fusion level has a significant effect on the incidence of proximal junctional kyphosis and outcome in adults after long posterior spinal fusion. Spine Deform 1:299\u2013305. https:\/\/doi.org\/10.1016\/j.jspd.2013.05.008","journal-title":"Spine Deform"},{"key":"8972_CR22","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1007\/bf00301335","volume":"5","author":"D Grob","year":"1996","unstructured":"Grob D, Humke T, Dvorak J (1996) Direct pediculo-body fixation in cases of spondylolisthesis with advanced intervertebral disc degeneration. Eur Spine J 5:281\u2013285. https:\/\/doi.org\/10.1007\/bf00301335","journal-title":"Eur Spine J"},{"key":"8972_CR23","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1186\/1471-2474-11-199","volume":"11","author":"C Birkenmaier","year":"2010","unstructured":"Birkenmaier C, Suess O, Pfeiffer M, Burger R, Schmieder K, Wegener B (2010) The european multicenter trial on the safety and efficacy of guided oblique lumbar interbody fusion (GO-LIF). BMC Musculoskelet Disord 11:199. https:\/\/doi.org\/10.1186\/1471-2474-11-199","journal-title":"BMC Musculoskelet Disord"},{"issue":"8","key":"8972_CR24","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1097\/00007632-200204150-00006","volume":"27","author":"RA Lehman","year":"2002","unstructured":"Lehman RA, Kuklo TR, Belmont PJ, Andersen RC, Polly DW (2002) Advantage of pedicle screw fixation directed into the apex of the sacral promontory over bicortical fixation: a biomechanical analysis. Spine 27(8):806\u2013811. https:\/\/doi.org\/10.1097\/00007632-200204150-00006","journal-title":"Spine"},{"key":"8972_CR25","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1227\/ons.0000000000000076","volume":"22","author":"A Kaufmann","year":"2022","unstructured":"Kaufmann A, Claus C, Tong D, Hanson C, Carr D, Houseman C, Soo TM (2022) Multilevel stabilization screws prevent proximal junctional failure and kyphosis in adult spinal deformity surgery: a comparative cohort study. Oper Neurosurg (Hagerstown) 22:150\u2013157. https:\/\/doi.org\/10.1227\/ons.0000000000000076","journal-title":"Oper Neurosurg (Hagerstown)"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-08972-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-025-08972-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-08972-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,15]],"date-time":"2025-09-15T16:19:11Z","timestamp":1757953151000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-025-08972-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,13]]},"references-count":25,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["8972"],"URL":"https:\/\/doi.org\/10.1007\/s00586-025-08972-0","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,13]]},"assertion":[{"value":"31 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 May 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 June 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}