{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T01:13:22Z","timestamp":1767748402224,"version":"3.48.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T00:00:00Z","timestamp":1754956800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T00:00:00Z","timestamp":1754956800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Instrumented posterior lumbar fixation (PLF) with fusion is the surgical standard for treating various degenerative changes or deformities of the spine. Several studies have shown the risk of adjacent segment pathology following fusion. Therefore, revision procedures are often required which involve extension of instrumentation to adjacent levels. The purpose of this study was to evaluate the stability of multisegmental-instrumentation of the lumbar spine when extended with continuous rods or with connectors to the lower mid thoracic spine.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Eight human specimens from Th5 to S1 were used and loaded with moments of 7.5 Nm about the three anatomical axes. A total of eight different PLF configurations were examined, with three conditions in a short Th10-S1 instrumentation and five conditions with a long Th6-S1 instrumentation. Continuous rods, and axial and lateral connectors were used to extend the PLF. Total range of motion (tROM) and total neutral zone (tNZ), as well as the intersegmental range of motion (iROM), were evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Overall, all configurations of the PLF demonstrated high primary stability. The iROM was less than 2 degrees in all segments studied where lengthening was performed with continuous rods or connectors. We found only a few significant differences, which are unlikely to be clinically relevant due to their very small magnitudes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>From a biomechanical point of view, the axial and lateral connectors provide comparable primary stability to a continuous rod system. Thus, the use of connectors is likely to be a suitable approach of extending an existing lumbar fixation to the lower and mid thoracic spine.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of evidence<\/jats:title>\n                    <jats:p>Biomechanical study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00586-025-09192-2","type":"journal-article","created":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T15:30:23Z","timestamp":1755012623000},"page":"5190-5199","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Investigation of instrumentation lengthening in the thoracolumbar junction of the spine - an in vitro Biomechanical study"],"prefix":"10.1007","volume":"34","author":[{"given":"Bastian","family":"Welke","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Schwarze","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christof","family":"Hurschler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shadi","family":"Kedah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dorothea","family":"Daentzer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dennis","family":"Nebel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,8,12]]},"reference":[{"key":"9192_CR1","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1016\/j.orthtr.2014.04.011","volume":"30","author":"I Werner","year":"2014","unstructured":"Werner I, Rauschmann M, Fleege C (2014) Anschlussdegeneration Langzeitkomplikation Nach lumbaler fusion. Sport-Orthop\u00e4die - Sport-Traumatologie -. Sports Orthop Traumatol 30:256\u2013266. https:\/\/doi.org\/10.1016\/j.orthtr.2014.04.011","journal-title":"Sports Orthop Traumatol"},{"key":"9192_CR2","doi-asserted-by":"publisher","first-page":"1497","DOI":"10.2106\/00004623-200407000-00020","volume":"86","author":"G Ghiselli","year":"2004","unstructured":"Ghiselli G, Wang JC, Bhatia NN, DEGENERATION IN THE LUMBAR SPINE (2004) ADJACENT SEGMENT. J Bone Joint Surgery-American Volume 86:1497\u20131503. https:\/\/doi.org\/10.2106\/00004623-200407000-00020","journal-title":"J Bone Joint Surgery-American Volume"},{"key":"9192_CR3","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1097\/00007632-199503010-00004","volume":"20","author":"SL Weinhoffer","year":"1995","unstructured":"Weinhoffer SL, Guyer RD, Herbert M, Griffith SL (1995) Intradiscal pressure measurements above an instrumented fusion: a cadaveric study. Spine (Phila Pa 20:526\u2013531","journal-title":"Spine (Phila Pa"},{"key":"9192_CR4","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1097\/00007632-199603010-00004","volume":"21","author":"DHK Chow","year":"1996","unstructured":"Chow DHK, Luk KDK, Evans JH, Leong JCY (1996) Effects of short anterior lumbar interbody fusion on biomechanics of neighboring unfused segments. Spine (Phila Pa 21:549\u2013555. https:\/\/doi.org\/10.1097\/00007632-199603010-00004","journal-title":"Spine (Phila Pa"},{"key":"9192_CR5","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1186\/s12891-023-06649-7","volume":"24","author":"W Wei","year":"2023","unstructured":"Wei W, Wang T, Liu J et al (2023) Biomechanical effect of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion: a finite element study. BMC Musculoskelet Disord 24:521. https:\/\/doi.org\/10.1186\/s12891-023-06649-7","journal-title":"BMC Musculoskelet Disord"},{"key":"9192_CR6","doi-asserted-by":"publisher","first-page":"1938","DOI":"10.1097\/01.brs.0000137069.88904.03","volume":"29","author":"P Park","year":"2004","unstructured":"Park P, Garton HJ, Gala VC et al (2004) Adjacent segment disease after lumbar or lumbosacral fusion. Rev Literature: Spine 29:1938\u20131944. https:\/\/doi.org\/10.1097\/01.brs.0000137069.88904.03","journal-title":"Rev Literature: Spine"},{"key":"9192_CR7","doi-asserted-by":"publisher","first-page":"346","DOI":"10.4103\/0019-5413.114912","volume":"47","author":"K-Y Ha","year":"2013","unstructured":"Ha K-Y, Son J-M, Im J-H, Oh I-S (2013) Risk factors for adjacent segment degeneration after surgical correction of degenerative lumbar scoliosis. Indian J Orthop 47:346\u2013351. https:\/\/doi.org\/10.4103\/0019-5413.114912","journal-title":"Indian J Orthop"},{"key":"9192_CR8","doi-asserted-by":"publisher","first-page":"5161503","DOI":"10.1155\/2022\/5161503","volume":"2022","author":"J Ouchida","year":"2022","unstructured":"Ouchida J, Nakashima H, Kanemura T et al (2022) Adjacent segment degeneration after Short-Segment lateral lumbar interbody fusion (LLIF). Biomed Res Int 2022:5161503. https:\/\/doi.org\/10.1155\/2022\/5161503","journal-title":"Biomed Res Int"},{"key":"9192_CR9","doi-asserted-by":"publisher","first-page":"24915","DOI":"10.52965\/001c.24915","volume":"13","author":"EM Pinto","year":"2021","unstructured":"Pinto EM, Teixeria A, Frada R et al (2021) Patient-Related risk factors for the development of lumbar spine adjacent segment pathology. Orthop Rev (Pavia) 13:24915. https:\/\/doi.org\/10.52965\/001c.24915","journal-title":"Orthop Rev (Pavia)"},{"key":"9192_CR10","doi-asserted-by":"publisher","first-page":"726","DOI":"10.1007\/s00586-021-06970-6","volume":"31","author":"C Liebsch","year":"2022","unstructured":"Liebsch C, Tao Y, Kienle A, Wilke H-J (2022) Validity and interobserver agreement of a new radiographic grading system for intervertebral disc degeneration: part III. Thoracic spine. Eur Spine J 31:726\u2013734. https:\/\/doi.org\/10.1007\/s00586-021-06970-6","journal-title":"Eur Spine J"},{"key":"9192_CR11","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1007\/s00586-005-1029-9","volume":"15","author":"H-J Wilke","year":"2006","unstructured":"Wilke H-J, Rohlmann F, Neidlinger-Wilke C et al (2006) Validity and interobserver agreement of a new radiographic grading system for intervertebral disc degeneration: part I. Lumbar spine. Eur Spine J 15:720\u2013730. https:\/\/doi.org\/10.1007\/s00586-005-1029-9","journal-title":"Eur Spine J"},{"key":"9192_CR12","doi-asserted-by":"publisher","first-page":"e0271349","DOI":"10.1371\/journal.pone.0271349","volume":"17","author":"S Schroeder","year":"2022","unstructured":"Schroeder S, Jaeger S, Schwer J et al (2022) Accuracy measurement of different marker based motion analysis systems for Biomechanical applications: A round robin study. PLoS ONE 17:e0271349. https:\/\/doi.org\/10.1371\/journal.pone.0271349","journal-title":"PLoS ONE"},{"key":"9192_CR13","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1097\/00007632-199703010-00020","volume":"22","author":"NR Crawford","year":"1997","unstructured":"Crawford NR, Dickman CA (1997) Construction of local vertebral coordinate systems using a digitizing probe. Technical note. Spine (Phila Pa 1976) 22:559\u2013563. https:\/\/doi.org\/10.1097\/00007632-199703010-00020","journal-title":"Spine (Phila Pa 1976)"},{"key":"9192_CR14","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1007\/s005860050045","volume":"7","author":"H Wilke","year":"1998","unstructured":"Wilke H, Wenger K, Claes L (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 7:148\u2013154","journal-title":"Eur Spine J"},{"key":"9192_CR15","unstructured":"R Core Team (2021) R: A language and environment for statistical computing"},{"key":"9192_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3171\/foc.2001.10.4.12","volume":"10","author":"JK Burkus","year":"2001","unstructured":"Burkus JK, Foley K, Haid R, LeHuec J-C (2001) Surgical interbody research Group\u2013radiographic assessment of interbody fusion devices: fusion criteria for anterior lumbar interbody surgery. NeuroSurg Focus 10:1\u20139. https:\/\/doi.org\/10.3171\/foc.2001.10.4.12","journal-title":"NeuroSurg Focus"},{"key":"9192_CR17","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-018-5664-3","author":"B Welke","year":"2018","unstructured":"Welke B, Schwarze M, Hurschler C et al (2018) In vitro investigation of two connector types for continuous rod construct to extend lumbar spinal instrumentation. Eur Spine J. https:\/\/doi.org\/10.1007\/s00586-018-5664-3","journal-title":"Eur Spine J"},{"key":"9192_CR18","doi-asserted-by":"publisher","first-page":"101708","DOI":"10.1016\/j.bas.2022.101708","volume":"3","author":"U Vieweg","year":"2022","unstructured":"Vieweg U, Keck J, Kr\u00fcger S et al (2022) Biomechanical comparison of different rod-to-rod connectors to a conventional titanium- and Cobalt chromium posterior spinal fixation system. Brain Spine 3:101708. https:\/\/doi.org\/10.1016\/j.bas.2022.101708","journal-title":"Brain Spine"},{"key":"9192_CR19","doi-asserted-by":"publisher","first-page":"1270","DOI":"10.1097\/BRS.0000000000003061","volume":"44","author":"MH Foltz","year":"2019","unstructured":"Foltz MH, Freeman AL, Loughran G et al (2019) Mechanical performance of posterior spinal instrumentation and growing rod implants: experimental and computational study. Spine (Phila Pa 1976) 44:1270\u20131278. https:\/\/doi.org\/10.1097\/BRS.0000000000003061","journal-title":"Spine (Phila Pa 1976)"},{"key":"9192_CR20","doi-asserted-by":"publisher","first-page":"1506","DOI":"10.1016\/j.spinee.2017.04.020","volume":"17","author":"G Hill","year":"2017","unstructured":"Hill G, Nagaraja S, Akbarnia BA et al (2017) Retrieval and clinical analysis of distraction-based dual growing rod constructs for early-onset scoliosis. Spine J 17:1506\u20131518. https:\/\/doi.org\/10.1016\/j.spinee.2017.04.020","journal-title":"Spine J"},{"key":"9192_CR21","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1007\/s00590-014-1445-9","volume":"24","author":"C Ren","year":"2014","unstructured":"Ren C, Song Y, Liu L, Xue Y (2014) Adjacent segment degeneration and disease after lumbar fusion compared with motion-preserving procedures: a meta-analysis. Eur J Orthop Surg Traumatol 24:245\u2013253. https:\/\/doi.org\/10.1007\/s00590-014-1445-9","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"9192_CR22","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1007\/s00264-018-4241-z","volume":"43","author":"K Hashimoto","year":"2019","unstructured":"Hashimoto K, Aizawa T, Kanno H, Itoi E (2019) Adjacent segment degeneration after fusion spinal surgery-a systematic review. Int Orthop 43:987\u2013993. https:\/\/doi.org\/10.1007\/s00264-018-4241-z","journal-title":"Int Orthop"},{"key":"9192_CR23","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.spinee.2010.09.026","volume":"11","author":"WR Sears","year":"2011","unstructured":"Sears WR, Sergides IG, Kazemi N et al (2011) Incidence and prevalence of surgery at segments adjacent to a previous posterior lumbar arthrodesis. Spine J 11:11\u201320. https:\/\/doi.org\/10.1016\/j.spinee.2010.09.026","journal-title":"Spine J"},{"key":"9192_CR24","doi-asserted-by":"publisher","first-page":"1554","DOI":"10.1016\/j.spinee.2020.05.100","volume":"20","author":"CJ Donnally","year":"2020","unstructured":"Donnally CJ, Patel PD, Canseco JA et al (2020) Current incidence of adjacent segment pathology following lumbar fusion versus motion-preserving procedures: a systematic review and meta-analysis of recent projections. Spine J 20:1554\u20131565. https:\/\/doi.org\/10.1016\/j.spinee.2020.05.100","journal-title":"Spine J"},{"key":"9192_CR25","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1097\/00007632-199503150-00018","volume":"20","author":"M Penta","year":"1995","unstructured":"Penta M, Sandhu A, Fraser RD (1995) Magnetic resonance imaging assessment of disc degeneration 10 years after anterior lumbar interbody fusion. Spine 20:743\u2013747","journal-title":"Spine"},{"key":"9192_CR26","doi-asserted-by":"publisher","first-page":"1952","DOI":"10.1097\/01.brs.0000228849.37321.a8","volume":"31","author":"EK Wai","year":"2006","unstructured":"Wai EK, Santos ERG, Morcom Ra, Fraser RD (2006) Magnetic resonance imaging 20 years after anterior lumbar interbody fusion. Spine 31:1952\u20131956. https:\/\/doi.org\/10.1097\/01.brs.0000228849.37321.a8","journal-title":"Spine"},{"key":"9192_CR27","doi-asserted-by":"publisher","first-page":"1882","DOI":"10.1007\/s00586-015-4040-9","volume":"24","author":"D Volkheimer","year":"2015","unstructured":"Volkheimer D, Malakoutian M, Oxland TR, Wilke H-J (2015) Limitations of current in vitro test protocols for investigation of instrumented adjacent segment biomechanics: critical analysis of the literature. European spine journal: official publication of the European spine society, the European spinal deformity society, and the European section of the cervical. Spine Res Soc 24:1882\u20131892. https:\/\/doi.org\/10.1007\/s00586-015-4040-9","journal-title":"Spine Res Soc"},{"key":"9192_CR28","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.spinee.2004.07.007","volume":"4","author":"AS Hilibrand","year":"2004","unstructured":"Hilibrand AS, Robbins M (2004) Adjacent segment degeneration and adjacent segment disease: the consequences of spinal fusion? Spine J 4:190\u2013194. https:\/\/doi.org\/10.1016\/j.spinee.2004.07.007","journal-title":"Spine J"},{"key":"9192_CR29","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/j.ocl.2011.07.006","volume":"42","author":"T Lund","year":"2011","unstructured":"Lund T, Oxland TR (2011) Adjacent level disk disease?\u2014Is it really a fusion disease?? Orthop Clin North Am 42:529\u2013541. https:\/\/doi.org\/10.1016\/j.ocl.2011.07.006","journal-title":"Orthop Clin North Am"},{"key":"9192_CR30","doi-asserted-by":"publisher","first-page":"1865","DOI":"10.1007\/s00586-015-3992-0","volume":"24","author":"M Malakoutian","year":"2015","unstructured":"Malakoutian M, Volkheimer D, Street J et al (2015) Do in vivo kinematic studies provide insight into adjacent segment degeneration? A qualitative systematic literature review. Eur Spine J 24:1865\u20131881. https:\/\/doi.org\/10.1007\/s00586-015-3992-0","journal-title":"Eur Spine J"},{"key":"9192_CR31","doi-asserted-by":"publisher","first-page":"30496","DOI":"10.1038\/s41598-024-82132-0","volume":"14","author":"C Liebsch","year":"2024","unstructured":"Liebsch C, Obid P, Vogt M et al (2024) Spinal instrumentation length affects adjacent segment range of motion and intradiscal pressure. Sci Rep 14:30496. https:\/\/doi.org\/10.1038\/s41598-024-82132-0","journal-title":"Sci Rep"},{"key":"9192_CR32","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1007\/s00586-024-08529-7","volume":"34","author":"C Liebsch","year":"2025","unstructured":"Liebsch C, Obid P, Vogt M et al (2025) How does thoracic scoliosis surgery affect thoracolumbar spinal flexibility and lumbar intradiscal pressure? An in vitro study confirming the importance of the rib cage. Eur Spine J 34:8\u201316. https:\/\/doi.org\/10.1007\/s00586-024-08529-7","journal-title":"Eur Spine J"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-09192-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-025-09192-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-09192-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T01:11:40Z","timestamp":1767748300000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-025-09192-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,12]]},"references-count":32,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2025,11]]}},"alternative-id":["9192"],"URL":"https:\/\/doi.org\/10.1007\/s00586-025-09192-2","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"type":"print","value":"0940-6719"},{"type":"electronic","value":"1432-0932"}],"subject":[],"published":{"date-parts":[[2025,8,12]]},"assertion":[{"value":"31 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 August 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}