{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T05:19:39Z","timestamp":1791523179243,"version":"4.3.4"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,11,10]],"date-time":"2025-11-10T00:00:00Z","timestamp":1762732800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,11,10]],"date-time":"2025-11-10T00:00:00Z","timestamp":1762732800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1007\/s00586-025-09568-4","type":"journal-article","created":{"date-parts":[[2025,11,10]],"date-time":"2025-11-10T00:56:43Z","timestamp":1762736203000},"page":"1354-1362","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Feasibility of synthetic CT images for robotic pedicle screw planning and navigation"],"prefix":"10.1007","volume":"35","author":[{"given":"Ardavan","family":"Kashtiara","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Beld\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dieter","family":"Thijs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timo","family":"De Bondt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johan","family":"Van Goethem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Van de Kelft","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,10]]},"reference":[{"key":"9568_CR1","unstructured":"Kelft EVd (2016) Surgery of the spine and spinal cord A neurosurgical approach. Springer Nature"},{"issue":"1","key":"9568_CR2","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1007\/BF01676569","volume":"6","author":"N Boos","year":"1997","unstructured":"Boos N, Webb JK (1997) Pedicle screw fixation in spinal disorders: a European view. Eur Spine J 6(1):2\u201318","journal-title":"Eur Spine J"},{"issue":"11","key":"9568_CR3","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.2106\/00004623-199911000-00003","volume":"81","author":"JE Lonstein","year":"1999","unstructured":"Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81(11):1519\u20131528","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"9568_CR4","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","volume":"21","author":"ID Gelalis","year":"2012","unstructured":"Gelalis ID, Paschos NK, Pakos EE et al (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21(2):247\u2013255","journal-title":"Eur Spine J"},{"issue":"3","key":"9568_CR5","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1007\/s00586-012-2499-1","volume":"22","author":"X Hu","year":"2013","unstructured":"Hu X, Ohnmeiss DD, Lieberman IH (2013) Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients. Eur Spine J 22(3):661\u2013666","journal-title":"Eur Spine J"},{"issue":"2","key":"9568_CR6","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.ST.19.00020","volume":"10","author":"IH Lieberman","year":"2020","unstructured":"Lieberman IH, Kisinde S, Hesselbacher S (2020) Robotic-assisted pedicle screw placement during spine surgery. JBJS Essential Surgical Techniques 10(2):e0020","journal-title":"JBJS Essential Surgical Techniques"},{"key":"9568_CR7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2021.109999","volume":"144","author":"L Morb\u00e9e","year":"2021","unstructured":"Morb\u00e9e L, Chen M, Herregods N, Pullens P, Jans LBO (2021) MRI-based synthetic CT of the lumbar spine: geometric measurements for surgery planning in comparison with CT. Eur J Radiol 144:109999","journal-title":"Eur J Radiol"},{"issue":"2","key":"9568_CR8","doi-asserted-by":"publisher","DOI":"10.3171\/CASE23120","volume":"6","author":"AD Davidar","year":"2023","unstructured":"Davidar AD, Judy BF, Hersh AM et al (2023) Robot-assisted screw fixation in a cadaver utilizing magnetic resonance imaging\u2013based synthetic computed tomography: toward radiation-free spine surgery. Illustrative case. J Neurosurg Case Lessons 6(2):CASE23120","journal-title":"J Neurosurg Case Lessons"},{"key":"9568_CR9","doi-asserted-by":"crossref","unstructured":"Lafranca PPG, Rommelspacher Y, Walter SG et al (2025) The safety and accuracy of radiation-free spinal navigation using a short, scoliosis-specific BoneMRI-protocol, compared to CT. Eur Spine J","DOI":"10.1016\/j.bas.2024.103170"},{"issue":"1","key":"9568_CR10","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1016\/j.jos.2020.11.008","volume":"27","author":"T Asari","year":"2022","unstructured":"Asari T, Rokunohe D, Sasaki E et al (2022) Occupational ionizing radiation-induced skin injury among orthopedic surgeons: a clinical survey. J Orthop Sci 27(1):266\u2013271","journal-title":"J Orthop Sci"},{"issue":"4","key":"9568_CR11","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0095233","volume":"9","author":"H Funao","year":"2014","unstructured":"Funao H, Ishii K, Momoshima S et al (2014) Surgeons\u2019 exposure to radiation in single- and multi-level minimally invasive transforaminal lumbar interbody fusion; a prospective study. PLoS One 9(4):e95233","journal-title":"PLoS One"},{"issue":"2","key":"9568_CR12","doi-asserted-by":"publisher","first-page":"251","DOI":"10.5021\/ad.2019.31.2.251","volume":"31","author":"HS Yoon","year":"2019","unstructured":"Yoon HS, Heo JH, Lee SH, Shin J, Choi GS, Byun JW (2019) Squamous cell carcinoma on the fingers of orthopedic surgeon induced by occupational radiation exposure. Ann Dermatol 31(2):251\u2013253","journal-title":"Ann Dermatol"},{"issue":"6","key":"9568_CR13","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1093\/occmed\/kqi048","volume":"55","author":"G Mastrangelo","year":"2005","unstructured":"Mastrangelo G, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B (2005) Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med 55(6):498\u2013500","journal-title":"Occup Med"},{"issue":"20","key":"9568_CR14","doi-asserted-by":"publisher","first-page":"2637","DOI":"10.1097\/00007632-200010150-00016","volume":"25","author":"YR Rampersaud","year":"2000","unstructured":"Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 25(20):2637\u20132645","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"9568_CR15","first-page":"120","volume":"9","author":"DT Schwartz","year":"2008","unstructured":"Schwartz DT (2008) Counter-Point: are we really ordering too many CT scans? West J Emerg Med 9(2):120\u2013122","journal-title":"West J Emerg Med"},{"issue":"6","key":"9568_CR16","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1016\/j.spinee.2024.01.007","volume":"24","author":"BM Striano","year":"2024","unstructured":"Striano BM, Crawford AM, Verhofste BP et al (2024) Intraoperative navigation increases the projected lifetime cancer risk in patients undergoing surgery for adolescent idiopathic scoliosis. Spine J 24(6):1087\u20131094","journal-title":"Spine J"},{"issue":"6","key":"9568_CR17","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1001\/jamainternmed.2025.0505","volume":"185","author":"R Smith-Bindman","year":"2025","unstructured":"Smith-Bindman R, Chu PW, Azman Firdaus H et al (2025) Projected lifetime cancer risks from current computed tomography imaging. JAMA Intern Med 185(6):710\u2013719","journal-title":"JAMA Intern Med"},{"issue":"25","key":"9568_CR18","doi-asserted-by":"publisher","first-page":"E1580","DOI":"10.1097\/BRS.0b013e318271b1fa","volume":"37","author":"E Van de Kelft","year":"2012","unstructured":"Van de Kelft E, Costa F, Van der Planken D, Schils F (2012) A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and stealthstation navigation. Spine (Phila Pa 1976) 37(25):E1580\u20131587","journal-title":"Spine (Phila Pa 1976)"},{"issue":"4 Suppl Spine","key":"9568_CR19","doi-asserted-by":"publisher","first-page":"325","DOI":"10.3171\/spi.2004.100.4.0325","volume":"100","author":"RF Heary","year":"2004","unstructured":"Heary RF, Bono CM, Black M (2004) Thoracic pedicle screws: postoperative computerized tomography scanning assessment. J Neurosurg 100(4 Suppl Spine):325\u2013331. https:\/\/doi.org\/10.3171\/spi.2004.100.4.0325","journal-title":"J Neurosurg"},{"issue":"4","key":"9568_CR20","doi-asserted-by":"publisher","first-page":"839","DOI":"10.14245\/ns.2142560.180","volume":"18","author":"Q Zhang","year":"2021","unstructured":"Zhang Q, Fan MX, Han XG, Liu YJ, He D, Liu B, Tian W (2021) Risk factors of unsatisfactory robot-assisted pedicle screw placement: a case-control study. Neurospine 18(4):839\u2013844. https:\/\/doi.org\/10.14245\/ns.2142560.180","journal-title":"Neurospine"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-09568-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-025-09568-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-09568-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T09:02:28Z","timestamp":1774515748000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-025-09568-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,10]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["9568"],"URL":"https:\/\/doi.org\/10.1007\/s00586-025-09568-4","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-7617997\/v1","asserted-by":"object"}]},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,10]]},"assertion":[{"value":"15 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 October 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 November 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 November 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}