{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T20:13:07Z","timestamp":1793391187759,"version":"4.5.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2025,12,22]],"date-time":"2025-12-22T00:00:00Z","timestamp":1766361600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,12,22]],"date-time":"2025-12-22T00:00:00Z","timestamp":1766361600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This study aimed to analyze adverse events associated with Mazor X surgical guidance robots, focusing on parameters such as root causes, vertebral distribution, surgical delay, robot abandonment, and more.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>330 adverse events reported within the Manufacturer and User Facility Device Experience (MAUDE) database for the Mazor X (MX) and Mazor X Stealth Edition (MXSE) robot guidance systems were analyzed and categorized based on the root causes, vertebral distribution, surgical delay, robot abandonment, and patient outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Both the MX and MXSE adverse events were primarily due to external root causes (35% and 52%, respectively), with user error being the most common. Deviations were most likely to affect the L3, L4, and L5 vertebra, and deviate either medially or laterally. Motor deficits were the most common adverse patient outcome for MX, while sensory deficits were the most common for MXSE. There were two deaths associated with the MX, compared to zero deaths with the MXSE.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>While the MAUDE database cannot be used to calculate the incidence or prevalence of adverse events, it provides insight into the types of adverse events that tend to occur with medical devices. MAUDE reports suggest that user-related errors account for most of the adverse events that occur, underscoring the need for focused surgeon training. Our study highlights the importance of understanding both the types of adverse events and their root causes to promote patient safety and reduce complication rates.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00586-025-09683-2","type":"journal-article","created":{"date-parts":[[2025,12,22]],"date-time":"2025-12-22T14:48:25Z","timestamp":1766414905000},"page":"4797-4806","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Analysis of root causes of adverse events with Mazor X and Mazor X stealth edition-guided spine surgeries: an FDA MAUDE database study"],"prefix":"10.1007","volume":"35","author":[{"given":"Apratim","family":"Maity","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ethan D. L.","family":"Brown","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Max","family":"Ward","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emily A.","family":"Orsino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel M.","family":"Schneider","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel M.","family":"Sciubba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheng-fu Larry","family":"Lo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,22]]},"reference":[{"issue":"5","key":"9683_CR1","doi-asserted-by":"publisher","DOI":"10.3171\/2017.3.FOCUS179","volume":"42","author":"G Molliqaj","year":"2017","unstructured":"Molliqaj G, Schatlo B, Alaid A, Solomiichuk V, Rohde V, Schaller K, Tessitore E (2017) Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery. Neurosurg Focus 42(5):E14. https:\/\/doi.org\/10.3171\/2017.3.FOCUS179","journal-title":"Neurosurg Focus"},{"key":"9683_CR2","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2021.578674","volume":"8","author":"SH Farber","year":"2021","unstructured":"Farber SH, Pacult MA, Godzik J, Walker CT, Turner JD, Porter RW, Uribe JS (2021) Robotics in spine surgery: a technical overview and review of key concepts. Front Surg 8:578674. https:\/\/doi.org\/10.3389\/fsurg.2021.578674","journal-title":"Front Surg"},{"issue":"1","key":"9683_CR3","doi-asserted-by":"publisher","DOI":"10.3390\/robotics12010001","volume":"12","author":"K M\u00f3ga","year":"2023","unstructured":"M\u00f3ga K, Ferencz A, Haidegger T (2023) What is next in computer-assisted spine surgery? Advances in image-guided robotics and extended reality. Robotics 12(1):1. https:\/\/doi.org\/10.3390\/robotics12010001","journal-title":"Robotics"},{"issue":"Suppl 5","key":"9683_CR4","doi-asserted-by":"publisher","DOI":"10.21037\/atm.2019.07.93","volume":"7","author":"MS Galetta","year":"2019","unstructured":"Galetta MS, Leider JD, Divi SN, Goyal DKC, Schroeder GD (2019) Robotics in spinal surgery. Ann Transl Med 7(Suppl 5):S165. https:\/\/doi.org\/10.21037\/atm.2019.07.93","journal-title":"Ann Transl Med"},{"key":"9683_CR5","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2022.884247","volume":"9","author":"RA de la P\u00e9rez Torre","year":"2022","unstructured":"de la P\u00e9rez Torre RA, Ramanathan S, Williams AL, Perez-Cruet MJ (2022) Minimally-invasive assisted robotic spine surgery (MARSS). Front Surg 9:884247. https:\/\/doi.org\/10.3389\/fsurg.2022.884247","journal-title":"Front Surg"},{"issue":"3","key":"9683_CR6","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1177\/21925682221126116","volume":"13","author":"GJ Kirchner","year":"2023","unstructured":"Kirchner GJ, Kim AH, Kwart AH, Weddle JB, Bible JE (2023) Reported events associated with spine robots: an analysis of the food and drug administration\u2019s manufacturer and user facility device experience database. Glob Spine J 13(3):855\u2013860. https:\/\/doi.org\/10.1177\/21925682221126116","journal-title":"Glob Spine J"},{"issue":"3","key":"9683_CR7","doi-asserted-by":"publisher","DOI":"10.3171\/2014.1.FOCUS13526","volume":"36","author":"F Shweikeh","year":"2014","unstructured":"Shweikeh F, Amadio JP, Arnell M, Barnard ZR, Kim TT, Johnson JP, Drazin D (2014) Robotics and the spine: a review of current and ongoing applications. Neurosurg Focus 36(3):E10. https:\/\/doi.org\/10.3171\/2014.1.FOCUS13526","journal-title":"Neurosurg Focus"},{"issue":"1","key":"9683_CR8","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1007\/s11701-020-01147-7","volume":"15","author":"JA Buza 3rd","year":"2021","unstructured":"Buza JA 3, Good CR, Lehman RA Jr, Pollina J, Chua RV, Buchholz AL, Gum JL (2021) Robotic-assisted cortical bone trajectory (CBT) screws using the Mazor X stealth edition (MXSE) system: workflow and technical tips for safe and efficient use. J Robot Surg 15(1):13\u201323. https:\/\/doi.org\/10.1007\/s11701-020-01147-7","journal-title":"J Robot Surg"},{"key":"9683_CR9","unstructured":"Medtronic Mazor Robotic Guidance. Medtronic2022"},{"key":"9683_CR10","unstructured":"Administration USFD Overview of Device Regulation 2024 [04\/27\/2024]. Available from: https:\/\/www.fda.gov\/medical-devices\/device-advice-comprehensive-regulatory-assistance\/overview-device-regulation"},{"key":"9683_CR11","unstructured":"Administration USFD MAUDE - Manufacturer and User Facility Device Experience 2024 [04\/06\/2024]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfMAUDE\/search.cfm"},{"key":"9683_CR12","unstructured":"Administration USFD FDA Premarket Notification Database 2024 [04\/21\/2024]. Available from: https:\/\/fda.report\/PMN\/K163221"},{"key":"9683_CR13","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1016\/j.wneu.2019.02.217","volume":"126","author":"A Perdomo-Pantoja","year":"2019","unstructured":"Perdomo-Pantoja A, Ishida W, Zygourakis C, Holmes C, Iyer RR, Cottrill E, Theodore N, Witham TF, Lo SL (2019) Accuracy of current techniques for placement of pedicle screws in the spine: a comprehensive systematic review and meta-analysis of 51,161 screws. World Neurosurg 126:664-678.e3. https:\/\/doi.org\/10.1016\/j.wneu.2019.02.217","journal-title":"World Neurosurg"},{"issue":"2","key":"9683_CR14","doi-asserted-by":"publisher","first-page":"E111","DOI":"10.1097\/BRS.0000000000003193","volume":"45","author":"HM Li","year":"2020","unstructured":"Li HM, Zhang RJ, Shen CL (2020) Accuracy of pedicle screw placement and clinical outcomes of robot-assisted technique versus conventional freehand technique in spine surgery from nine randomized controlled trials: a meta-analysis. Spine 45(2):E111\u2013E119. https:\/\/doi.org\/10.1097\/BRS.0000000000003193","journal-title":"Spine"},{"issue":"1","key":"9683_CR15","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1186\/s12874-021-01396-6","volume":"21","author":"M Levaillant","year":"2021","unstructured":"Levaillant M, Marcilly R, Levaillant L, Michel P, Hamel-Broza JF, Vallet B, Lamer A (2021) Assessing the hospital volume-outcome relationship in surgery: a scoping review. BMC Med Res Methodol 21(1):204. https:\/\/doi.org\/10.1186\/s12874-021-01396-6","journal-title":"BMC Med Res Methodol"},{"issue":"2","key":"9683_CR16","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1111\/jhq.12036","volume":"37","author":"MA Cooper","year":"2015","unstructured":"Cooper MA, Ibrahim A, Lyu H, Makary MA (2015) Underreporting of robotic surgery complications. J Healthc Quality: Official Publication Natl Association Healthc Qual 37(2):133\u2013138. https:\/\/doi.org\/10.1111\/jhq.12036","journal-title":"J Healthc Quality: Official Publication Natl Association Healthc Qual"},{"issue":"4","key":"9683_CR17","doi-asserted-by":"publisher","first-page":"e0151470","DOI":"10.1371\/journal.pone.0151470","volume":"11","author":"H Alemzadeh","year":"2016","unstructured":"Alemzadeh H, Raman J, Leveson N, Kalbarczyk Z, Iyer RK (2016) Adverse events in robotic surgery: a retrospective study of 14 years of FDA data. PLoS One 11(4):e0151470. https:\/\/doi.org\/10.1371\/journal.pone.0151470","journal-title":"PLoS One"},{"issue":"1","key":"9683_CR18","doi-asserted-by":"publisher","DOI":"10.1186\/s10195-022-00669-0","volume":"23","author":"S Luengo-Matos","year":"2022","unstructured":"Luengo-Matos S, S\u00e1nchez-G\u00f3mez LM, Hijas-G\u00f3mez AI, Garc\u00eda-Carpintero EE, Ballesteros-Mass\u00f3 R, Polo-deSantos M (2022) Efficacy and safety of robotic spine surgery: systematic review and meta-analysis. Journal of orthopaedics and traumatology\u202f: official journal of the Italian Society of Orthopaedics and Traumatology 23(1):49. https:\/\/doi.org\/10.1186\/s10195-022-00669-0","journal-title":"Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology"},{"issue":"1","key":"9683_CR19","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1186\/s12893-022-01723-8","volume":"22","author":"K Yan","year":"2022","unstructured":"Yan K, Zhang Q, Tian W (2022) Comparison of accuracy and safety between second-generation TiRobot-assisted and free-hand thoracolumbar pedicle screw placement. BMC Surg 22(1):275. https:\/\/doi.org\/10.1186\/s12893-022-01723-8","journal-title":"BMC Surg"},{"issue":"1","key":"9683_CR20","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1186\/s13018-023-03774-w","volume":"18","author":"Y Li","year":"2023","unstructured":"Li Y, Wang Y, Ma X, Ma J, Dong B, Yang P, Sun Y, Zhou L, Shen J (2023) Comparison of short-term clinical outcomes between robot-assisted and freehand pedicle screw placement in spine surgery: a meta-analysis and systematic review. J Orthop Surg Res 18(1):359. https:\/\/doi.org\/10.1186\/s13018-023-03774-w","journal-title":"J Orthop Surg Res"},{"issue":"3","key":"9683_CR21","doi-asserted-by":"publisher","first-page":"917","DOI":"10.1111\/os.12703","volume":"12","author":"XY Cai","year":"2020","unstructured":"Cai XY, Sun MS, Huang YP, Liu ZX, Liu CJ, Du CF, Yang Q (2020) Biomechanical effect of L<Subscript>4<\/Subscript> -L<Subscript>5<\/Subscript> intervertebral disc degeneration on the lower lumbar spine: a finite element study. Orthop Surg 12(3):917\u2013930. https:\/\/doi.org\/10.1111\/os.12703","journal-title":"Orthop Surg"},{"issue":"3","key":"9683_CR22","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1007\/s00586-004-0797-y","volume":"14","author":"Y Tamura","year":"2005","unstructured":"Tamura Y, Sugano N, Sasama T, Sato Y, Tamura S, Yonenobu K, Yoshikawa H, Ochi T (2005) Surface-based registration accuracy of CT-based image-guided spine surgery. Eur Spine J 14(3):291\u2013297. https:\/\/doi.org\/10.1007\/s00586-004-0797-y","journal-title":"Eur Spine J"},{"issue":"9","key":"9683_CR23","doi-asserted-by":"publisher","first-page":"1504","DOI":"10.1016\/j.spinee.2021.05.015","volume":"21","author":"NJ Lee","year":"2021","unstructured":"Lee NJ, Zuckerman SL, Buchanan IA, Boddapati V, Mathew J, Leung E, Park PJ, Pham MH, Buchholz AL, Khan A, Pollina J, Mullin JP, Jazini E, Haines C, Schuler TC, Good CR, Lombardi JM, Lehman RA (2021) Is there a difference between navigated and non-navigated robot cohorts in robot-assisted spine surgery? A multicenter, propensity-matched analysis of 2,800 screws and 372 patients. Spine J 21(9):1504\u20131512. https:\/\/doi.org\/10.1016\/j.spinee.2021.05.015","journal-title":"Spine J"},{"issue":"5","key":"9683_CR24","doi-asserted-by":"publisher","first-page":"841","DOI":"10.3171\/2021.8.SPINE21330","volume":"36","author":"JI Liounakos","year":"2021","unstructured":"Liounakos JI, Khan A, Eliahu K, Mao JZ, Good CR, Pollina J, Haines CM, Gum JL, Schuler TC, Jazini E, Chua RV, Shafa E, Buchholz AL, Pham MH, Poelstra KA, Wang MY (2021) Ninety-day complication, revision, and readmission rates for current-generation robot-assisted thoracolumbar spinal fusion surgery: results of a multicenter case series. J Neurosurg Spine 36(5):841\u2013848. https:\/\/doi.org\/10.3171\/2021.8.SPINE21330","journal-title":"J Neurosurg Spine"},{"key":"9683_CR25","doi-asserted-by":"publisher","first-page":"9","DOI":"10.2147\/RSRR.S190720","volume":"6","author":"M D'Souza","year":"2019","unstructured":"D\u2019Souza M, Gendreau J, Feng A, Kim LH, Ho AL, Veeravagu A (2019) Robotic-assisted spine surgery: history, efficacy, cost, and future trends. Robotic surgery (Auckland) 6:9\u201323. https:\/\/doi.org\/10.2147\/RSRR.S190720","journal-title":"Robotic surgery (Auckland)"},{"issue":"1","key":"9683_CR26","doi-asserted-by":"publisher","first-page":"E3","DOI":"10.3171\/2021.10.FOCUS21496","volume":"52","author":"Z Pennington","year":"2022","unstructured":"Pennington Z, Judy BF, Zakaria HM, Lakomkin N, Mikula AL, Elder BD, Theodore N (2022) Learning curves in robot-assisted spine surgery: a systematic review and proposal of application to residency curricula. NeuroSurg Focus 52(1):E3. https:\/\/doi.org\/10.3171\/2021.10.FOCUS21496","journal-title":"NeuroSurg Focus"},{"issue":"Suppl 2","key":"9683_CR27","doi-asserted-by":"publisher","first-page":"S107","DOI":"10.21182\/jmisst.2025.02376","volume":"10","author":"G Balamurali","year":"2025","unstructured":"Balamurali G, Subramanian SS, Panneerselvam K (2025) Evolving paradigms in spine surgery training: integrating technology, ethics, and minimally invasive techniques. J Minim Invasive Spine Surg Tech 10(Suppl 2):S107\u2013S118. https:\/\/doi.org\/10.21182\/jmisst.2025.02376","journal-title":"J Minim Invasive Spine Surg Tech"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-09683-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-025-09683-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-025-09683-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T13:54:02Z","timestamp":1786456442000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-025-09683-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,22]]},"references-count":27,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["9683"],"URL":"https:\/\/doi.org\/10.1007\/s00586-025-09683-2","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,22]]},"assertion":[{"value":"12 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 November 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 December 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 December 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}