{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T20:27:10Z","timestamp":1789590430074,"version":"build-2803163510"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T00:00:00Z","timestamp":1775952000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T00:00:00Z","timestamp":1775952000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Beijing Shijitan Hospital Funds","award":["2020-q08"],"award-info":[{"award-number":["2020-q08"]}]},{"DOI":"10.13039\/501100012149","name":"National Key Scientific Instrument and Equipment Development Projects of China","doi-asserted-by":"publisher","award":["2022YFC2407501"],"award-info":[{"award-number":["2022YFC2407501"]}],"id":[{"id":"10.13039\/501100012149","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1007\/s00586-026-09894-1","type":"journal-article","created":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T00:10:20Z","timestamp":1775952620000},"page":"5082-5090","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Thoracolumbar burst fractures: robot-assisted mono-segment fixation with vertebral body grafting versus short-segment fixation \u2014 a propensity score-matched cohort study"],"prefix":"10.1007","volume":"35","author":[{"given":"Junjie","family":"Qiao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuyu","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruizhao","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinyao","family":"Lv","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiutong","family":"Fang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,12]]},"reference":[{"key":"9894_CR1","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.spinee.2012.10.041","volume":"14","author":"KB Wood","year":"2014","unstructured":"Wood KB, Li W, Lebl DR, Ploumis A (2014) Management of thoracolumbar spine fractures. Spine J 14:145\u2013164. https:\/\/doi.org\/10.1016\/j.spinee.2012.10.041","journal-title":"Spine J"},{"key":"9894_CR2","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/j.jor.2016.06.019","volume":"13","author":"Y Katsuura","year":"2016","unstructured":"Katsuura Y, Osborn JM, Cason GW (2016) The epidemiology of thoracolumbar trauma: A meta-analysis. J Orthop 13:383\u2013388. https:\/\/doi.org\/10.1016\/j.jor.2016.06.019","journal-title":"J Orthop"},{"key":"9894_CR3","doi-asserted-by":"publisher","first-page":"34S","DOI":"10.1177\/2192568218771668","volume":"8","author":"AP Verheyden","year":"2018","unstructured":"Verheyden AP, Spiegl UJ, Ekkerlein H, Gercek E, Hauck S, Josten C, Kandziora F, Katscher S, Kobbe P, Knop C, Lehmann W, Meffert RH, M\u00fcller CW, Partenheimer A, Schinkel C, Schleicher P, Scholz M, Ulrich C, Hoelzl A (2018) Treatment of Fractures of the Thoracolumbar Spine: Recommendations of the Spine Section of the German Society for Orthopaedics and Trauma (DGOU). Global Spine J 8:34S\u201345S. https:\/\/doi.org\/10.1177\/2192568218771668","journal-title":"Global Spine J"},{"key":"9894_CR4","doi-asserted-by":"publisher","first-page":"713","DOI":"10.14245\/ns.2142390.195","volume":"18","author":"N Peev","year":"2021","unstructured":"Peev N, Zileli M, Sharif S, Arif S, Brady Z (2021) Indications for Nonsurgical Treatment of Thoracolumbar Spine Fractures: WFNS Spine Committee Recommendations. Neurospine 18:713\u2013724. https:\/\/doi.org\/10.14245\/ns.2142390.195","journal-title":"Neurospine"},{"key":"9894_CR5","doi-asserted-by":"publisher","first-page":"1039100","DOI":"10.3389\/fsurg.2022.1039100","volume":"9","author":"ZW Luo","year":"2022","unstructured":"Luo ZW, Liao WJ, Sun BL, Wu JB, Zhang N, Zhang Y, Huang SH, Liu ZL, Zhang ZH, Liu JM (2022) Short-segment fixation and transpedicular bone grafting for the treatment of thoracolumbar spine fracture. Front Surg 9:1039100. https:\/\/doi.org\/10.3389\/fsurg.2022.1039100","journal-title":"Front Surg"},{"key":"9894_CR6","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1186\/s12891-023-06288-y","volume":"24","author":"T Hashimura","year":"2023","unstructured":"Hashimura T, Onishi E, Ota S, Tsukamoto Y, Yamashita S, Yasuda T (2023) Correction loss following short-segment posterior fixation for traumatic thoracolumbar burst fractures related to endplate and intervertebral disc destruction. BMC Musculoskelet Disord 24:174. https:\/\/doi.org\/10.1186\/s12891-023-06288-y","journal-title":"BMC Musculoskelet Disord"},{"key":"9894_CR7","doi-asserted-by":"publisher","first-page":"e36430","DOI":"10.1097\/md.0000000000036430","volume":"102","author":"Y Li","year":"2023","unstructured":"Li Y, Wei X, Liang Y, Song G (2023) Robot-assisted versus fluoroscopy-guided pedicle screw fixation of thoracolumbar compression fractures. Med (Baltim) 102:e36430. https:\/\/doi.org\/10.1097\/md.0000000000036430","journal-title":"Med (Baltim)"},{"key":"9894_CR8","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.spinee.2022.10.006","volume":"23","author":"AV Matur","year":"2023","unstructured":"Matur AV, Palmisciano P, Duah HO, Chilakapati SS, Cheng JS, Adogwa O (2023) Robotic and navigated pedicle screws are safer and more accurate than fluoroscopic freehand screws: a systematic review and meta-analysis. Spine J 23:197\u2013208. https:\/\/doi.org\/10.1016\/j.spinee.2022.10.006","journal-title":"Spine J"},{"key":"9894_CR9","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15:11\u201314. https:\/\/doi.org\/10.1097\/00007632-199001000-00004","journal-title":"Spine (Phila Pa 1976)"},{"key":"9894_CR10","doi-asserted-by":"publisher","first-page":"962","DOI":"10.1227\/NEU.0b013e31826a88c8","volume":"71","author":"R Babu","year":"2012","unstructured":"Babu R, Park JG, Mehta AI, Shan T, Grossi PM, Brown CR, Richardson WJ, Isaacs RE, Bagley CA, Kuchibhatla M, Gottfried ON (2012) Comparison of superior-level facet joint violations during open and percutaneous pedicle screw placement. Neurosurgery 71:962\u2013970. https:\/\/doi.org\/10.1227\/NEU.0b013e31826a88c8","journal-title":"Neurosurgery"},{"key":"9894_CR11","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1186\/s12891-024-07320-5","volume":"25","author":"KN Chou","year":"2024","unstructured":"Chou KN, Wang PW, Chung MH, Ju DT (2024) Hybrid kyphoplasty with short-versus intermediate- and long-segment pedicle screw fixations for the management of thoracolumbar burst fractures. BMC Musculoskelet Disord 25:203. https:\/\/doi.org\/10.1186\/s12891-024-07320-5","journal-title":"BMC Musculoskelet Disord"},{"key":"9894_CR12","doi-asserted-by":"publisher","first-page":"353","DOI":"10.14245\/ns.2244980.490","volume":"20","author":"J Hou","year":"2023","unstructured":"Hou J, Ren D, Chen Y, Geng L, Yao S, Wu H, Wang P (2023) Effectiveness of the Endplate Reduction Technique Combined With Bone Grafting for the Treatment of Thoracolumbar Fractures by Using Posterior Short-Segment Fixation. Neurospine 20:353\u2013364. https:\/\/doi.org\/10.14245\/ns.2244980.490","journal-title":"Neurospine"},{"key":"9894_CR13","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1186\/s12891-020-03576-9","volume":"21","author":"X Hu","year":"2020","unstructured":"Hu X, Ma W, Chen J, Wang Y, Jiang W (2020) Posterior short segment fixation including the fractured vertebra combined with kyphoplasty for unstable thoracolumbar osteoporotic burst fracture. BMC Musculoskelet Disord 21:566. https:\/\/doi.org\/10.1186\/s12891-020-03576-9","journal-title":"BMC Musculoskelet Disord"},{"key":"9894_CR14","doi-asserted-by":"publisher","first-page":"934","DOI":"10.1007\/s00586-023-07537-3","volume":"32","author":"KAC Oswald","year":"2023","unstructured":"Oswald KAC, K\u00e4lin J, Tinner C, Deml MC, Bigdon SF, Hoppe S, Benneker LM, Albers CE (2023) Anterior thoracolumbar column reconstruction with the vertebral body stent-safety and efficacy. Eur Spine J 32:934\u2013949. https:\/\/doi.org\/10.1007\/s00586-023-07537-3","journal-title":"Eur Spine J"},{"key":"9894_CR15","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1055\/s-0041-1726101","volume":"35","author":"AJ Skochdopole","year":"2021","unstructured":"Skochdopole AJ, Wagner RD, Davis MJ, Raj S, Winocour SJ, Ropper AE, Xu DS, Bohl MA, Reece EM (2021) Vascularized Bone Grafts in Spinal Reconstruction: An Overview of Nomenclature and Indications. Semin Plast Surg 35:50\u201353. https:\/\/doi.org\/10.1055\/s-0041-1726101","journal-title":"Semin Plast Surg"},{"key":"9894_CR16","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1097\/00007632-198311000-00003","volume":"8","author":"F Denis","year":"1983","unstructured":"Denis F (1983) The three column spine and its significance in the classification of acute thoracolumbar spinal injuries. Spine (Phila Pa 1976) 8:817\u2013831. https:\/\/doi.org\/10.1097\/00007632-198311000-00003","journal-title":"Spine (Phila Pa 1976)"},{"key":"9894_CR17","doi-asserted-by":"publisher","first-page":"712","DOI":"10.14444\/8660","volume":"18","author":"M Bhimreddy","year":"2024","unstructured":"Bhimreddy M, Hersh AM, Jiang K, Weber-Levine C, Davidar AD, Menta AK, Judy BF, Lubelski D, Bydon A, Weingart J, Theodore N (2024) Accuracy of Pedicle Screw Placement Using the ExcelsiusGPS Robotic Navigation Platform: An Analysis of 728 Screws. Int J Spine Surg 18:712\u2013720. https:\/\/doi.org\/10.14444\/8660","journal-title":"Int J Spine Surg"},{"key":"9894_CR18","doi-asserted-by":"publisher","first-page":"615","DOI":"10.3171\/2018.10.Spine18487","volume":"30","author":"X Han","year":"2019","unstructured":"Han X, Tian W, Liu Y, Liu B, He D, Sun Y, Han X, Fan M, Zhao J, Xu Y, Zhang Q (2019) Safety and accuracy of robot-assisted versus fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery: a prospective randomized controlled trial. J Neurosurg Spine 30:615\u2013622. https:\/\/doi.org\/10.3171\/2018.10.Spine18487","journal-title":"J Neurosurg Spine"},{"key":"9894_CR19","doi-asserted-by":"publisher","first-page":"824","DOI":"10.21037\/atm-20-1106","volume":"8","author":"YN Peng","year":"2020","unstructured":"Peng YN, Tsai LC, Hsu HC, Kao CH (2020) Accuracy of robot-assisted versus conventional freehand pedicle screw placement in spine surgery: a systematic review and meta-analysis of randomized controlled trials. Ann Transl Med 8:824. https:\/\/doi.org\/10.21037\/atm-20-1106","journal-title":"Ann Transl Med"},{"key":"9894_CR20","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1111\/os.12534","volume":"11","author":"Q Zhang","year":"2019","unstructured":"Zhang Q, Xu YF, Tian W, Le XF, Liu B, Liu YJ, He D, Sun YQ, Yuan Q, Lang Z, Han XG (2019) Comparison of Superior-Level Facet Joint Violations Between Robot-Assisted Percutaneous Pedicle Screw Placement and Conventional Open Fluoroscopic-Guided Pedicle Screw Placement. Orthop Surg 11:850\u2013856. https:\/\/doi.org\/10.1111\/os.12534","journal-title":"Orthop Surg"},{"key":"9894_CR21","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1186\/s13018-023-03774-w","volume":"18","author":"Y Li","year":"2023","unstructured":"Li Y, Wang Y, Ma X, Ma J, Dong B, Yang P, Sun Y, Zhou L, Shen J (2023) Comparison of short-term clinical outcomes between robot-assisted and freehand pedicle screw placement in spine surgery: a meta-analysis and systematic review. J Orthop Surg Res 18:359. https:\/\/doi.org\/10.1186\/s13018-023-03774-w","journal-title":"J Orthop Surg Res"},{"key":"9894_CR22","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1007\/s10143-024-02340-0","volume":"47","author":"X Wang","year":"2024","unstructured":"Wang X, Li HX, Zhu QS, Zhu YH (2024) Effectiveness and safety of robot-assisted versus fluoroscopy-assisted pedicle screw implantation in scoliosis surgery: a systematic review and meta-analysis. Neurosurg Rev 47:108. https:\/\/doi.org\/10.1007\/s10143-024-02340-0","journal-title":"Neurosurg Rev"},{"key":"9894_CR23","doi-asserted-by":"publisher","first-page":"534","DOI":"10.14444\/7070","volume":"14","author":"AW Reynolds","year":"2020","unstructured":"Reynolds AW, Philp FH, Gandhi S, Schmidt GL (2020) Patient Radiation Exposure Associated With the Use of Computer Navigation During Spinal Fusion. Int J Spine Surg 14:534\u2013537. https:\/\/doi.org\/10.14444\/7070","journal-title":"Int J Spine Surg"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-026-09894-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-026-09894-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-026-09894-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T13:54:09Z","timestamp":1786456449000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-026-09894-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,12]]},"references-count":23,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["9894"],"URL":"https:\/\/doi.org\/10.1007\/s00586-026-09894-1","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,12]]},"assertion":[{"value":"19 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 March 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 March 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 April 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Conflict of interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the institutional ethics committee ( IIT2026-036).","order":2,"name":"Ethics","label":"Ethics approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Given the retrospective design and use of de-identified data, the requirement for informed consent was waived by the institutional ethics committee.","order":3,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Declarations"}}]}}