{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T22:55:55Z","timestamp":1790636155640,"version":"4.1.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T00:00:00Z","timestamp":1790553600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T00:00:00Z","timestamp":1790553600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Spine J"],"DOI":"10.1007\/s00586-026-10404-6","type":"journal-article","created":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T05:42:24Z","timestamp":1790574144000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Fully percutaneous, navigation-assisted cervical pedicle screw instrumentation: technical note and a report of safety and accuracy"],"prefix":"10.1007","author":[{"given":"Gonzalo","family":"Moros-Daza","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feras","family":"Rawagah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8128-2721","authenticated-orcid":false,"given":"Bujung","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Marx","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petros","family":"Evangelou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hind","family":"Chaib","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Kipele","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ina","family":"Konietzko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2459-773X","authenticated-orcid":false,"given":"Adriana","family":"Moros-Daza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ehab","family":"Shiban","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,28]]},"reference":[{"issue":"9","key":"10404_CR1","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1097\/00007632-199705010-00009","volume":"22","author":"EL Jones","year":"1997","unstructured":"Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical Pedicle Screws Versus Lateral Mass Screws. Spine (Phila Pa 1976) 22(9):977\u2013982. https:\/\/doi.org\/10.1097\/00007632-199705010-00009","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"10404_CR2","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1016\/j.spinee.2006.03.019","volume":"6","author":"TL Johnston","year":"2006","unstructured":"Johnston TL, Karaikovic EE, Lautenschlager EP, Marcu D (2006) Cervical pedicle screws vs. lateral mass screws: uniplanar fatigue analysis and residual pullout strengths. Spine J 6(6):667\u2013672. https:\/\/doi.org\/10.1016\/j.spinee.2006.03.019","journal-title":"Spine J"},{"issue":"17","key":"10404_CR3","doi-asserted-by":"publisher","first-page":"1869","DOI":"10.1097\/01.brs.0000137287.67388.0b","volume":"29","author":"R Kothe","year":"2004","unstructured":"Kothe R, R\u00fcther W, Schneider E, Linke B (2004) Biomechanical Analysis of Transpedicular Screw Fixation in the Subaxial Cervical Spine. Spine (Phila Pa 1976) 29(17):1869\u20131875. https:\/\/doi.org\/10.1097\/01.brs.0000137287.67388.0b","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"10404_CR4","doi-asserted-by":"publisher","first-page":"299","DOI":"10.4103\/jcvjs.jcvjs_19_23","volume":"14","author":"IE Cechin","year":"2023","unstructured":"Cechin IE, De Barros AGC, Khan AA, Da Silva LECT (2023) The role of cervical pedicle screw in cervical spine trauma: A single-center retrospective study. J Craniovertebr Junction Spine 14(3):299\u2013305. https:\/\/doi.org\/10.4103\/jcvjs.jcvjs_19_23","journal-title":"J Craniovertebr Junction Spine"},{"key":"10404_CR5","doi-asserted-by":"publisher","unstructured":"Tan KA, Lin S, Chin BZ, Thadani VN, Hey HWD (2020) Anatomic techniques for cervical pedicle screw placement. J Spine Surg AME Publishing Co 262\u2013273. https:\/\/doi.org\/10.21037\/jss.2020.03.07","DOI":"10.21037\/jss.2020.03.07"},{"key":"10404_CR6","doi-asserted-by":"publisher","unstructured":"Jung YG, Jung SK, Lee BJ, Lee S, Jeong SK, Kim M et al (2020) The subaxial cervical pedicle screw for cervical spine diseases: The review of technical developments and complication avoidance. Neurologia Medico-Chirurgica. Japan Neurosurgical Society, pp 231\u2013243. https:\/\/doi.org\/10.2176\/nmc.ra.2019-0189","DOI":"10.2176\/nmc.ra.2019-0189"},{"issue":"16","key":"10404_CR7","doi-asserted-by":"publisher","first-page":"1853","DOI":"10.1097\/00007632-199708150-00010","volume":"22","author":"K Abumi","year":"1997","unstructured":"Abumi K, Kaneda K (1997) Pedicle Screw Fixation for Nontraumatic Lesions of the Cervical Spine. Spine (Phila Pa 1976) 22(16):1853\u20131863. https:\/\/doi.org\/10.1097\/00007632-199708150-00010","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"10404_CR8","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1097\/BSD.0b013e31824e65f4","volume":"27","author":"Z Ito","year":"2014","unstructured":"Ito Z, Higashino K, Kato S, Kim SS, Wong E, Yoshioka K et al (2014) Pedicle Screws Can be 4 Times Stronger Than Lateral Mass Screws for Insertion in the Midcervical Spine. J Spinal Disord Tech 27(2):80\u201385. https:\/\/doi.org\/10.1097\/BSD.0b013e31824e65f4","journal-title":"J Spinal Disord Tech"},{"key":"10404_CR9","doi-asserted-by":"publisher","unstructured":"Upendra B, Raghavendra R (2020) Techniques of cervical pedicle screw insertion in lower cervical spine - A review. J Clin Orthop Trauma Elsevier B V 794\u2013801. https:\/\/doi.org\/10.1016\/j.jcot.2020.06.040","DOI":"10.1016\/j.jcot.2020.06.040"},{"issue":"2","key":"10404_CR10","doi-asserted-by":"publisher","first-page":"E91","DOI":"10.1097\/BRS.0000000000001161","volume":"41","author":"K Phan","year":"2016","unstructured":"Phan K, Mobbs RJ (2016) Minimally Invasive Versus Open Laminectomy for Lumbar Stenosis. Spine (Phila Pa 1976) 41(2):E91\u2013100. https:\/\/doi.org\/10.1097\/BRS.0000000000001161","journal-title":"Spine (Phila Pa 1976)"},{"key":"10404_CR11","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1016\/j.wneu.2019.08.162","volume":"133","author":"LE Miller","year":"2020","unstructured":"Miller LE, Bhattacharyya S, Pracyk J (2020) Minimally Invasive Versus Open Transforaminal Lumbar Interbody Fusion for Single-Level Degenerative Disease: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. World Neurosurg 133:358\u2013365e4. https:\/\/doi.org\/10.1016\/j.wneu.2019.08.162","journal-title":"World Neurosurg"},{"issue":"10","key":"10404_CR12","doi-asserted-by":"publisher","first-page":"2502","DOI":"10.1007\/s00586-022-07327-3","volume":"31","author":"G Pokorny","year":"2022","unstructured":"Pokorny G, Amaral R, Marcelino F, Moriguchi R, Barreira I, Yozo M et al (2022) Minimally invasive versus open surgery for degenerative lumbar pathologies: a systematic review and meta-analysis. Eur Spine J 31(10):2502\u20132526. https:\/\/doi.org\/10.1007\/s00586-022-07327-3","journal-title":"Eur Spine J"},{"issue":"5","key":"10404_CR13","doi-asserted-by":"publisher","first-page":"753","DOI":"10.3171\/2021.10.SPINE211128","volume":"36","author":"J Mooney","year":"2022","unstructured":"Mooney J, Michalopoulos GD, Alvi MA, Zeitouni D, Chan AK, Mummaneni PV et al (2022) Minimally invasive versus open lumbar spinal fusion: a matched study investigating patient-reported and surgical outcomes. J Neurosurg Spine 36(5):753\u2013766. https:\/\/doi.org\/10.3171\/2021.10.SPINE211128","journal-title":"J Neurosurg Spine"},{"issue":"4","key":"10404_CR14","doi-asserted-by":"publisher","first-page":"612","DOI":"10.14444\/8297","volume":"16","author":"K Eseonu","year":"2022","unstructured":"Eseonu K, Oduoza U, Monem M, Tahir M (2022) Systematic Review of Cost-Effectiveness Analyses Comparing Open and Minimally Invasive Lumbar Spinal Surgery. Int J Spine Surg 16(4):612\u2013624. https:\/\/doi.org\/10.14444\/8297","journal-title":"Int J Spine Surg"},{"issue":"20","key":"10404_CR15","doi-asserted-by":"publisher","first-page":"2280","DOI":"10.1097\/01.brs.0000182275.31425.cd","volume":"30","author":"M Richter","year":"2005","unstructured":"Richter M, Cakir B, Schmidt R (2005) Cervical Pedicle Screws: Conventional Versus Computer-Assisted Placement of Cannulated Screws. Spine (Phila Pa 1976) 30(20):2280\u20132287. https:\/\/doi.org\/10.1097\/01.brs.0000182275.31425.cd","journal-title":"Spine (Phila Pa 1976)"},{"issue":"11","key":"10404_CR16","doi-asserted-by":"publisher","first-page":"2729","DOI":"10.1007\/s00586-018-5585-1","volume":"27","author":"S Chachan","year":"2018","unstructured":"Chachan S, Bin Abd Razak HR, Loo WL, Allen JC, Shree Kumar D (2018) Cervical pedicle screw instrumentation is more reliable with O-arm-based 3D navigation: analysis of cervical pedicle screw placement accuracy with O-arm-based 3D navigation. Eur Spine J 27(11):2729\u20132736. https:\/\/doi.org\/10.1007\/s00586-018-5585-1","journal-title":"Eur Spine J"},{"issue":"18","key":"10404_CR17","doi-asserted-by":"publisher","first-page":"1397","DOI":"10.1097\/BRS.0000000000001026","volume":"40","author":"AA Theologis","year":"2015","unstructured":"Theologis AA, Burch S (2015) Safety and Efficacy of Reconstruction of Complex Cervical Spine Pathology Using Pedicle Screws Inserted with Stealth Navigation and 3D Image-Guided (O-Arm) Technology. Spine (Phila Pa 1976) 40(18):1397\u20131406. https:\/\/doi.org\/10.1097\/BRS.0000000000001026","journal-title":"Spine (Phila Pa 1976)"},{"key":"10404_CR18","doi-asserted-by":"publisher","first-page":"S14","DOI":"10.14444\/7122","volume":"14","author":"D Coric","year":"2020","unstructured":"Coric D, Rossi VJ, Peloza J, Kim PK, Adamson TE (2020) Percutaneous, navigated minimally invasive posterior cervical pedicle screw fixation. Int J Spine Surg 14:S14\u201321. https:\/\/doi.org\/10.14444\/7122","journal-title":"Int J Spine Surg"},{"key":"10404_CR19","doi-asserted-by":"publisher","first-page":"27S","DOI":"10.1177\/21925682211029215","volume":"12","author":"D Coric","year":"2022","unstructured":"Coric D, Rossi V (2022) Percutaneous Posterior Cervical Pedicle Instrumentation (C1 to C7) With Navigation Guidance: Early Series of 27 Cases. Global Spine J 12:27S\u201333S. https:\/\/doi.org\/10.1177\/21925682211029215","journal-title":"Global Spine J"},{"key":"10404_CR20","doi-asserted-by":"publisher","unstructured":"Schmeiser G, Blume C, Hecht N, Mattes S, Ittrich H, Kothe R (2025) Navigated percutaneous placement of cervical pedicle screws: An anatomical feasibility study. Brain Spine 5. https:\/\/doi.org\/10.1016\/j.bas.2025.104199","DOI":"10.1016\/j.bas.2025.104199"},{"issue":"06","key":"10404_CR21","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1055\/a-2479-5742","volume":"86","author":"C Scholz","year":"2025","unstructured":"Scholz C, Hohenhaus M, Hubbe U, Volz F, Watzlawick R, Beck J et al (2025) First Experience Using a New Minimally Invasive Screw\u2013Rod System for Completely Percutaneous Pedicle Screw Fixation of the Cervical Spine. J Neurol Surg Cent Eur Neurosurg 86(06):537\u2013543. https:\/\/doi.org\/10.1055\/a-2479-5742","journal-title":"J Neurol Surg Cent Eur Neurosurg"},{"issue":"6","key":"10404_CR22","doi-asserted-by":"publisher","first-page":"919","DOI":"10.3233\/THC-161246","volume":"24","author":"J Bredow","year":"2016","unstructured":"Bredow J, Beyer F, Oppermann J, Kraus B, Meyer C, Stein G et al (2016) A novel classification of screw placement accuracy in the cervical spine. Technol Health Care 24(6):919\u2013925. https:\/\/doi.org\/10.3233\/THC-161246","journal-title":"Technol Health Care"},{"key":"10404_CR23","doi-asserted-by":"publisher","unstructured":"Adamski S, Stogowski P, Roc\u0142awski M, Pankowski R, Kloc W (2023) Review of currently used classifications for pedicle screw position grading in cervical, thoracic and lumbar spine. Chir Narzadow Ruchu Ortop Pol. Exemplum Scientific Publishing House, pp 165\u2013171. https:\/\/doi.org\/10.31139\/chnriop.2023.88.4.2","DOI":"10.31139\/chnriop.2023.88.4.2"},{"issue":"5","key":"10404_CR24","doi-asserted-by":"publisher","first-page":"E349","DOI":"10.1097\/BRS.0b013e318239cf1f","volume":"37","author":"K Abumi","year":"2012","unstructured":"Abumi K, Ito M, Sudo H (2012) Reconstruction of the Subaxial Cervical Spine Using Pedicle Screw Instrumentation. Spine (Phila Pa 1976) 37(5):E349\u2013E356. https:\/\/doi.org\/10.1097\/BRS.0b013e318239cf1f","journal-title":"Spine (Phila Pa 1976)"},{"key":"10404_CR25","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.clinbiomech.2018.02.009","volume":"53","author":"J Duff","year":"2018","unstructured":"Duff J, Hussain MM, Klocke N, Harris JA, Yandamuri SS, Bobinski L et al (2018) Does pedicle screw fixation of the subaxial cervical spine provide adequate stabilization in a multilevel vertebral body fracture model? An in vitro biomechanical study. Clin Biomech (Bristol Avon) 53:72\u201378. https:\/\/doi.org\/10.1016\/j.clinbiomech.2018.02.009","journal-title":"Clin Biomech (Bristol Avon)"},{"issue":"1","key":"10404_CR26","doi-asserted-by":"publisher","first-page":"252","DOI":"10.21037\/JSS.2019.09.28","volume":"6","author":"AF Joaquim","year":"2020","unstructured":"Joaquim AF, Tan L, Riew KD (2020) Posterior screw fixation in the subaxial cervical spine: a technique and literature review. J Spine Surg 6(1):252\u2013261. https:\/\/doi.org\/10.21037\/JSS.2019.09.28","journal-title":"J Spine Surg"},{"issue":"5","key":"10404_CR27","doi-asserted-by":"publisher","first-page":"863","DOI":"10.14444\/8339","volume":"16","author":"K Li","year":"2022","unstructured":"Li K, Miao J, Han YE, Lan J (2022) Freehand Regional Techniques for Subaxial Cervical Pedicle Screw Placement. Int J Spine Surg 16(5):863\u2013867. https:\/\/doi.org\/10.14444\/8339","journal-title":"Int J Spine Surg"},{"issue":"6","key":"10404_CR28","doi-asserted-by":"publisher","first-page":"1135","DOI":"10.1111\/os.13227","volume":"14","author":"K Zhang","year":"2022","unstructured":"Zhang K, Chen H, Chen K, Yang P, Yang H, Mao H (2022) O-Arm Navigated Cervical Pedicle Screw Fixation in the Treatment of Lower Cervical Fracture-Dislocation. Orthop Surg 14(6):1135\u20131142. https:\/\/doi.org\/10.1111\/os.13227","journal-title":"Orthop Surg"},{"key":"10404_CR29","doi-asserted-by":"publisher","unstructured":"Mahmoud A, Shanmuganathan K, Rocos B, Aftab S, Sedra F, Montgomery A (2021) Cervical spine pedicle screw accuracy in fluoroscopic, navigated and template guided systems\u2014a systematic review. Tomography. MDPI, pp 614\u2013622. https:\/\/doi.org\/10.3390\/tomography7040052","DOI":"10.3390\/tomography7040052"},{"key":"10404_CR30","doi-asserted-by":"publisher","unstructured":"Weber C, Akre K, Avellan C, Behbahani M, Werner D (2025) Minimally invasive pedicle screw placement with image-guided navigation in cervical spine injuries. Acta Neurochir (Wien) 167(1). https:\/\/doi.org\/10.1007\/s00701-025-06680-8","DOI":"10.1007\/s00701-025-06680-8"},{"issue":"1","key":"10404_CR31","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1097\/01.bsd.0000211239.21835.ad","volume":"20","author":"GYF Lee","year":"2007","unstructured":"Lee GYF, Massicotte EM, Rampersaud YR (2007) Clinical Accuracy of Cervicothoracic Pedicle Screw Placement A Comparison of the Open Lamino-foraminotomy and Computer-assisted Techniques. J Spinal Disord Tech 20(1):25\u201332. https:\/\/doi.org\/10.1097\/01.bsd.0000211239.21835.ad","journal-title":"J Spinal Disord Tech"},{"issue":"3","key":"10404_CR32","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1007\/s00586-004-0861-7","volume":"15","author":"E Kast","year":"2006","unstructured":"Kast E, Mohr K, Richter HP, B\u00f6rm W (2006) Complications of transpedicular screw fixation in the cervical spine. Eur Spine J 15(3):327\u2013334. https:\/\/doi.org\/10.1007\/s00586-004-0861-7","journal-title":"Eur Spine J"},{"issue":"5","key":"10404_CR33","doi-asserted-by":"publisher","first-page":"450","DOI":"10.3171\/SPI.2008.9.11.450","volume":"9","author":"Y Ito","year":"2008","unstructured":"Ito Y, Sugimoto Y, Tomioka M, Hasegawa Y, Nakago K, Yagata Y (2008) Clinical accuracy of 3D fluoroscopy\u2013assisted cervical pedicle screw insertion. J Neurosurg Spine 9(5):450\u2013453. https:\/\/doi.org\/10.3171\/SPI.2008.9.11.450","journal-title":"J Neurosurg Spine"},{"issue":"12","key":"10404_CR34","doi-asserted-by":"publisher","first-page":"2417","DOI":"10.1016\/j.spinee.2024.08.012","volume":"24","author":"MA Ruiz-Cardozo","year":"2024","unstructured":"Ruiz-Cardozo MA, Barot K, Brehm S, Bui T, Joseph K, Kann MR et al (2024) Pedicle screw placement in the cervical vertebrae using augmented reality-head mounted displays: a cadaveric proof-of-concept study. Spine J 24(12):2417\u20132427. https:\/\/doi.org\/10.1016\/j.spinee.2024.08.012","journal-title":"Spine J"}],"container-title":["European Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-026-10404-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00586-026-10404-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00586-026-10404-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T22:03:17Z","timestamp":1790632997000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00586-026-10404-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,28]]},"references-count":34,"alternative-id":["10404"],"URL":"https:\/\/doi.org\/10.1007\/s00586-026-10404-6","relation":{},"ISSN":["0940-6719","1432-0932"],"issn-type":[{"value":"0940-6719","type":"print"},{"value":"1432-0932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,28]]},"assertion":[{"value":"22 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 August 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 September 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 September 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}