{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T20:34:22Z","timestamp":1759178062522},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"S1","license":[{"start":{"date-parts":[[2013,8,28]],"date-time":"2013-08-28T00:00:00Z","timestamp":1377648000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"published-print":{"date-parts":[[2014,7]]},"DOI":"10.1007\/s00590-013-1296-9","type":"journal-article","created":{"date-parts":[[2013,8,27]],"date-time":"2013-08-27T07:23:21Z","timestamp":1377588201000},"page":"183-191","source":"Crossref","is-referenced-by-count":10,"title":["Transpedicular vertebral body augmentation reinforced with pedicle screw fixation in fresh traumatic A2 and A3 lumbar fractures: comparison between two devices and two bone cements"],"prefix":"10.1007","volume":"24","author":[{"given":"Panagiotis","family":"Korovessis","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Konstantinos","family":"Vardakastanis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Repantis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vasilios","family":"Vitsas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,8,28]]},"reference":[{"key":"1296_CR1","doi-asserted-by":"crossref","unstructured":"Olerud S, Karlstr\u00f6m G, Sj\u00f6str\u00f6m L (1988) Transpedicular fixation of thoracolumbar vertebral fractures. Clin Orthop Relat Res 227:44-51.22744","DOI":"10.1097\/00003086-198802000-00007"},{"key":"1296_CR2","unstructured":"McLain RF, Sparling E, Benson DR (1993) Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report. J Bone Joint Surg Am 75:162-7.75162"},{"key":"1296_CR3","doi-asserted-by":"crossref","unstructured":"McCormack T, Karaikovic E, Gaines RW. (1994) The load sharing classification of spine fractures. Spine 19:1741-4.191741","DOI":"10.1097\/00007632-199408000-00014"},{"key":"1296_CR4","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1097\/01.brs.0000209251.65417.16","volume":"31","author":"P Korovessis","year":"2006","unstructured":"Korovessis P, Baikousis A, Zacharatos S et al (2006) Combined anterior plus posterior stabilization versus posterior short-segment instrumentation and fusion for mid-lumbar (L2\u2013L4) burst fractures. Spine 31:859\u2013868","journal-title":"Spine"},{"key":"1296_CR5","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1097\/BRS.0b013e318166e0bb","volume":"33","author":"P Korovessis","year":"2008","unstructured":"Korovessis P, Hadjipavlou A, Repantis Th (2008) Minimal invasive short posterior instrumentation plus balloon kyphoplasty with calcium phosphate for burst and severe compression lumbar fractures. Spine 33:658\u2013667","journal-title":"Spine"},{"key":"1296_CR6","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.spinee.2007.04.004","volume":"8","author":"JC Eck","year":"2008","unstructured":"Eck JC, Nachtigall D, Humphreys SC, Hodges SD (2008) Comparison of vertebroplasty and balloon kyphoplasty for treatment of vertebral compression fractures: a meta-analysis of the literature. Spine 8:488\u2013497","journal-title":"Spine"},{"key":"1296_CR7","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1097\/00007632-200103010-00018","volume":"26","author":"BF Christensen","year":"2001","unstructured":"Christensen BF, Laursen M, Gelineck J et al (2001) Interobserver and intraobserver agreement of radiograph interpretation with and without pedicle screw implants. Spine 26:538\u2013544","journal-title":"Spine"},{"issue":"12","key":"1296_CR8","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1186\/1471-2474-12-206","volume":"22","author":"P Korovessis","year":"2011","unstructured":"Korovessis P, Repantis T, Miller LE et al (2011) Initial clinical experience with a novel vertebral augmentation system for treatment of symptomatic vertebral compression fractures: a case series of 26 consecutive patients. BMC Musculoskelet Disord 22(12):206\u2013209","journal-title":"BMC Musculoskelet Disord"},{"key":"1296_CR9","doi-asserted-by":"crossref","first-page":"E73","DOI":"10.1097\/01.brs.0000152162.64015.fb","volume":"30","author":"JJ Verlaan","year":"2005","unstructured":"Verlaan JJ, Dhert WJ, Verbout AJ et al (2005) Balloon vertebroplasty in combination with pedicle screw instrumentation: a novel technique to treat thoracic and lumbar burst fractures. Spine 30:E73\u2013E79","journal-title":"Spine"},{"key":"1296_CR10","doi-asserted-by":"crossref","first-page":"1832","DOI":"10.1097\/01.brs.0000173897.67839.92","volume":"30","author":"JJ Verlaan","year":"2005","unstructured":"Verlaan JJ, van de Kraats EB, Oner FC et al (2005) Bone displacement and the role of longitudinal ligaments during balloon vertebroplasty in traumatic thoracolumbar fractures. Spine 30:1832\u20131839","journal-title":"Spine"},{"issue":"16","key":"1296_CR11","doi-asserted-by":"crossref","first-page":"2721","DOI":"10.1016\/S0142-9612(03)00086-3","volume":"24","author":"M Bohner","year":"2003","unstructured":"Bohner M, Gasser B, Baroud G, Heini P (2003) Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure. Biomaterials 24(16):2721\u20132730","journal-title":"Biomaterials"},{"key":"1296_CR12","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.2214\/ajr.183.4.1831097","volume":"183","author":"DH Choe","year":"2004","unstructured":"Choe DH, Marom EM, Ahrar K et al (2004) Pulmonary embolism of polymethylmethacrylate during percutaneous vertebroplast and kyphoplasty. Am J Roentenol 183:1097\u20131102","journal-title":"Am J Roentenol"},{"key":"1296_CR13","doi-asserted-by":"crossref","first-page":"E209","DOI":"10.1097\/00007632-200405150-00023","volume":"29","author":"SW Yu","year":"2004","unstructured":"Yu SW, Chen WJ, Lin WC et al (2004) Serious pyogenic spondylitis following vertebroplasty: a case report. Spine 29:E209\u2013E211","journal-title":"Spine"},{"key":"1296_CR14","doi-asserted-by":"crossref","first-page":"E294","DOI":"10.1097\/01.BRS.0000131211.87594.B0","volume":"29","author":"KY Yoo","year":"2004","unstructured":"Yoo KY, Jeong SW, Yoon W, Lee J (2004) Acute respiratory distress syndrome associated with pulmonary cement embolism following percutaneous vertebroplasty with polymethylmethacrylate. Spine 29:E294\u2013E297","journal-title":"Spine"},{"key":"1296_CR15","first-page":"166","volume":"33","author":"P Galibert","year":"1987","unstructured":"Galibert P, Dearamond H, Rosat P, Le Gars D (1987) Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie 33:166\u2013168","journal-title":"Neurochirurgie"},{"key":"1296_CR16","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.1213\/00000539-200210000-00049","volume":"95","author":"HL Chen","year":"2002","unstructured":"Chen HL, Wong CS, Ho ST et al (2002) A lethal pulmonary embolism during percutaneous vertebroplasty. Anesth Analg 95:1060\u20131062","journal-title":"Anesth Analg"},{"key":"1296_CR17","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1097\/00007632-200101150-00017","volume":"26","author":"A Alanay","year":"2001","unstructured":"Alanay A, Acaroglu E, Yazici M et al (2001) Short-segment pedicle instrumentation of thoracolumbar burst fractures: does transpedicular intracorporeal grafting prevent early failure? Spine 26:213\u2013217","journal-title":"Spine"},{"key":"1296_CR18","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1097\/00005131-199509060-00007","volume":"9","author":"DL Kramer","year":"1995","unstructured":"Kramer DL, Rodgers WB, Mansfield FL (1995) Transpedicular instrumentation and short-segment fusion of thoracolumbar fractures: a prospective study using a single instrumentation system. J Orthop Trauma 9:499\u2013506","journal-title":"J Orthop Trauma"},{"key":"1296_CR19","doi-asserted-by":"crossref","first-page":"162","DOI":"10.2106\/00004623-199302000-00002","volume":"75","author":"RF McLain","year":"1993","unstructured":"McLain RF, Sparling E, Benson DR (1993) Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. J Bone Joint Surg Am 75:162\u2013167","journal-title":"J Bone Joint Surg Am"},{"key":"1296_CR20","doi-asserted-by":"crossref","first-page":"2646","DOI":"10.1097\/01.brs.0000244555.28310.40","volume":"31","author":"ST Wang","year":"2006","unstructured":"Wang ST, Ma HL, Liu CL, Yu WK, Chang MC, Chen TH (2006) Is fusion necessary for surgically treated burst fractures of the thoracolumbar and lumbar spine? A prospective, randomized study. Spine (Phila Pa 1976) 31:2646\u20132652","journal-title":"Spine (Phila Pa 1976)"},{"key":"1296_CR21","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.2106\/JBJS.H.00510","volume":"91","author":"LY Dai","year":"2009","unstructured":"Dai LY, Jiang LS, Jiang SD (2009) Posterior short-segment fixation with or without fusion for thoracolumbar burst fractures. A five to seven-year. J Bone Joint Surg Am 91:1033\u20131041","journal-title":"J Bone Joint Surg Am"},{"key":"1296_CR22","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1097\/01.brs.0000208161.74286.ad","volume":"31","author":"T Toyone","year":"2006","unstructured":"Toyone T, Tanaka T, Kato D et al (2006) The treatment of acute thoracolumbar burst fractures with transpedicular intracorporeal hydroxyapatite grafting following indirect reduction and pedicle screw fixation: a prospective study. Spine 31:208\u2013214","journal-title":"Spine"},{"key":"1296_CR23","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1007\/s00586-006-0197-6","volume":"16","author":"KC Li","year":"2007","unstructured":"Li KC, Li Anna F-Y, Hsieh CH et al (2007) Transpedicle body augmenter in painful osteoporotic compression fractures. Eur Spine J 16:589\u2013598","journal-title":"Eur Spine J"},{"key":"1296_CR24","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S8756-3282(99)00127-1","volume":"25","author":"H Deramond","year":"1999","unstructured":"Deramond H, Wright N, Belkoff S (1999) Temperature elevation caused by bone cement polymerization during vertebroplasty. Bone 25:17\u201321","journal-title":"Bone"},{"key":"1296_CR25","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1097\/00007632-200206150-00010","volume":"27","author":"TH Lim","year":"2002","unstructured":"Lim TH, Brebach GT, Renner SM et al (2002) Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty. Spine 27:1297\u20131302","journal-title":"Spine"},{"key":"1296_CR26","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1097\/00007632-200406010-00009","volume":"29","author":"S Tomita","year":"2004","unstructured":"Tomita S, Molloy S, Jasper LE et al (2004) Biomechanical comparison of kyphoplasty with different bone cements. Spine 29:1203\u20131207","journal-title":"Spine"},{"key":"1296_CR27","doi-asserted-by":"crossref","first-page":"1503","DOI":"10.1097\/BRS.0b013e318067dd24","volume":"32","author":"A Mahar","year":"2007","unstructured":"Mahar A, Kim Choll, Wedemeyer M et al (2007) Short-segment fixation of lumbar burst fractures using pedicle fixation at the level of the fracture. Spine 32:1503\u20131507","journal-title":"Spine"},{"key":"1296_CR28","doi-asserted-by":"crossref","first-page":"2270","DOI":"10.1097\/01.brs.0000142469.41565.2a","volume":"29","author":"D Fribourg","year":"2004","unstructured":"Fribourg D, Tang C, Sra P, Delamarter R, Bae H (2004) Incidence of subsequent vertebral fracture after kyphoplasty. Spine 29:2270\u20132277","journal-title":"Spine"},{"key":"1296_CR29","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1097\/01.brs.0000157172.00635.3a","volume":"32","author":"D-Y Kim","year":"2005","unstructured":"Kim D-Y, Lee S-H, Chung SK et al (2005) Comparison of multifidus muscle atrophy and trunk extension muscle strength: percutaneous versus open pedicle screw fixation. Spine 32:123\u2013129","journal-title":"Spine"},{"key":"1296_CR30","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1007\/s00586-006-0221-x","volume":"16","author":"C Schizas","year":"2007","unstructured":"Schizas C, Michel J, Kosmopoulos V et al (2007) Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization. Eur Spine J 16:613\u2013617","journal-title":"Eur Spine J"},{"key":"1296_CR31","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1016\/j.spinee.2011.07.029","volume":"11","author":"Y Park","year":"2011","unstructured":"Park Y, Won HJ, Lee TY, Sung YN (2011) Percutaneous placement of pedicle screws in overweight and obese patients. Spine J 11:919\u2013924","journal-title":"Spine J"},{"issue":"4","key":"1296_CR32","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1097\/BRS.0b013e31826b3aef","volume":"38","author":"P Korovessis","year":"2013","unstructured":"Korovessis P, Vardakastanis K, Repantis T et al (2013) Balloon kyphoplasty versus KIVA vertebral augmentation\u2014comparison of 2 techniques for osteoporotic vertebral body fractures: a prospective randomized study. Spine 38(4):292\u2013299","journal-title":"Spine"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-013-1296-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00590-013-1296-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-013-1296-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,4]],"date-time":"2022-03-04T22:47:23Z","timestamp":1646434043000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00590-013-1296-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,8,28]]},"references-count":32,"journal-issue":{"issue":"S1","published-print":{"date-parts":[[2014,7]]}},"alternative-id":["1296"],"URL":"https:\/\/doi.org\/10.1007\/s00590-013-1296-9","relation":{},"ISSN":["1633-8065","1432-1068"],"issn-type":[{"value":"1633-8065","type":"print"},{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,8,28]]}}}