{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T03:43:37Z","timestamp":1783568617356,"version":"3.55.0"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2014,10,2]],"date-time":"2014-10-02T00:00:00Z","timestamp":1412208000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"published-print":{"date-parts":[[2015,4]]},"DOI":"10.1007\/s00590-014-1550-9","type":"journal-article","created":{"date-parts":[[2014,10,1]],"date-time":"2014-10-01T08:05:02Z","timestamp":1412150702000},"page":"457-464","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Plate fixation of distal radius fracture and related complications"],"prefix":"10.1007","volume":"25","author":[{"given":"Laurent","family":"Obert","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francois","family":"Loisel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sonia","family":"Huard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S\u00e9verin","family":"Rochet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Lepage","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregoire","family":"Leclerc","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Garbuio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2014,10,2]]},"reference":[{"key":"1550_CR1","unstructured":"Dumontier\u00a0C, Herzberg\u00a0G (2001) Symposiums-Recent fractures of the distal radius in adults. Rev Chir Orthop 87(5):1S67"},{"key":"1550_CR2","doi-asserted-by":"crossref","unstructured":"Obert L (2010) Fixation of distal radius fracture in adult (Ost\u00e9osynth\u00e8se des fractures r\u00e9centes de l\u2019extr\u00e9mit\u00e9 distale du radius de l\u2019adulte). Conf\u00e9rences d\u2019enseignement Sofcot 2010, Elsevier, 48\u201379. doi: 10.1016\/B978-2-8101-0057-6.00003-0","DOI":"10.1016\/B978-2-8101-0057-6.00003-0"},{"key":"1550_CR3","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1097\/00005131-200409000-00003","volume":"18","author":"KA Egol","year":"2004","unstructured":"Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ (2004) Biomechanics of locked plates and screws. J Orthop Trauma 18:488\u2013493","journal-title":"J Orthop Trauma"},{"key":"1550_CR4","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.rco.2007.07.008","volume":"94","author":"H Pichon","year":"2008","unstructured":"Pichon H, Chergaoui A, Jager S, Carpentier E, Jourdel F, Chaussard C, Saragaglia D (2008) Volar fixed angle plate LCP 3.5 for dorsally distal radius fracture. About 24 cases. Rev Chir Orthop Rep Appar Mot 94:152\u2013159","journal-title":"Rev Chir Orthop Rep Appar Mot"},{"key":"1550_CR5","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1007\/s00113-002-0547-8","volume":"106","author":"M Sakhaii","year":"2003","unstructured":"Sakhaii M, Groenewold U, Klonz A, Reilmann H (2003) Results after palmar plate-osteosynthesis with angularly stable T-plate in 100 distal radius fractures: a prospective study. Unfallchirurg 106:272\u2013280","journal-title":"Unfallchirurg"},{"key":"1550_CR6","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1007\/s00276-010-0754-x","volume":"33","author":"N Gasse","year":"2011","unstructured":"Gasse N, Lepage D, Pem R, Bernard C, Lerais JM, Garbuio P, Obert L (2011) Anatomical and radiological study applied to distal radius surgery. Surg Radiol Anat 33:485\u2013490","journal-title":"Surg Radiol Anat"},{"key":"1550_CR7","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/S0266-7681(97)80263-X","volume":"22","author":"J Laulan","year":"1997","unstructured":"Laulan J, Bismuth JP, Sicre G, Garaud P (1997) The different types of algodystrophy after fracture of the distal radius: predictive criteria of outcome after 1 year. J Hand Surg: Br Eur 22:441\u2013447","journal-title":"J Hand Surg: Br Eur"},{"key":"1550_CR8","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/S1297-3203(01)00037-3","volume":"20","author":"GR Sennwald","year":"2001","unstructured":"Sennwald GR, Della Santa D (2001) Unstable fracture of the distal radius and its treatment: comparison of three techniques: external fixation, intramedullary pinning and AO plates. Chir Main 20:218\u2013225","journal-title":"Chir Main"},{"key":"1550_CR9","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1097\/BOT.0b013e318059b993","volume":"21","author":"R Arora","year":"2007","unstructured":"Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21:316\u2013322","journal-title":"J Orthop Trauma"},{"key":"1550_CR10","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/0363-5023(93)90241-T","volume":"18","author":"FA Kaempffe","year":"1993","unstructured":"Kaempffe FA, Wheeler DR, Peimer CA, Hvisdak KS, Ceravolo J, Senall J (1993) Severe fractures of the distal radius: effect of amount and duration of external fixator distraction on outcome. J Hand Surg Am 18:33\u201341","journal-title":"J Hand Surg Am"},{"key":"1550_CR11","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1053\/jhsu.2002.32081","volume":"27","author":"JL Orbay","year":"2002","unstructured":"Orbay JL, Fernandez DL (2002) Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 27:205\u2013215","journal-title":"J Hand Surg Am"},{"key":"1550_CR12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00264-002-0393-x","volume":"27","author":"H Drobetz","year":"2003","unstructured":"Drobetz H, Kutscha-Lissberg E (2003) Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 27:1\u20136","journal-title":"Int Orthop"},{"key":"1550_CR13","doi-asserted-by":"crossref","first-page":"125","DOI":"10.3928\/0147-7447-20020201-15","volume":"25","author":"KJ Constantine","year":"2002","unstructured":"Constantine KJ, Clawson MC, Stern PJ (2002) Volar neutralization plate fixation of dorsally displaced distal radius fractures. Orthopedics 25:125\u2013128","journal-title":"Orthopedics"},{"key":"1550_CR14","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1302\/0301-620X.80B2.8351","volume":"80","author":"JS Bell","year":"1998","unstructured":"Bell JS, Wollstein R, Citron ND (1998) Rupture of flexor pollicis longus tendon: a complication of volar plating of the distal radius. J Bone Joint Surg Br 80:225\u2013226","journal-title":"J Bone Joint Surg Br"},{"key":"1550_CR15","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1053\/jhsu.1999.1279","volume":"24","author":"JA Nunley","year":"1999","unstructured":"Nunley JA, Rowan PR (1999) Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius. J Hand Surg Am 24:1279\u20131280","journal-title":"J Hand Surg Am"},{"key":"1550_CR16","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/01.blo.0000223998.02765.0d","volume":"451","author":"EC Benson","year":"2006","unstructured":"Benson EC, DeCarvalho A, Mikola EA, Veitch JM, Moneim MS (2006) Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res 451:218\u2013222","journal-title":"Clin Orthop Relat Res"},{"key":"1550_CR17","first-page":"245","volume":"32","author":"HD Skoff","year":"2003","unstructured":"Skoff HD (2003) Postfracture extensor pollicis longus tenosynovitis and tendon rupture: a scientific study and personal series. Am J Orthop 32:245\u2013247","journal-title":"Am J Orthop"},{"key":"1550_CR18","first-page":"118","volume":"87","author":"JN Goubier","year":"2001","unstructured":"Goubier JN, Zouaoui S, Saillant G (2001) The complications of the distal radius fractures (Les complications des fractures du radius distal). Rev Chir Orthop 87:118","journal-title":"Rev Chir Orthop"},{"issue":"Suppl 2","key":"1550_CR19","doi-asserted-by":"crossref","first-page":"B31","DOI":"10.1016\/j.injury.2003.09.023","volume":"34","author":"M Wagner","year":"2003","unstructured":"Wagner M (2003) General principles for the clinical use of the LCP. Injury 34(Suppl 2):B31\u2013B42","journal-title":"Injury"},{"issue":"7 Suppl 1","key":"1550_CR20","first-page":"29","volume":"93","author":"T B\u00e9gu\u00e9","year":"2007","unstructured":"B\u00e9gu\u00e9 T (2007) Biomechanical and clinical aspects of plates with locked screws (Aspects biom\u00e9caniques et cliniques des plaques \u00e0 vis verrouill\u00e9es). Rev Chir Orthop 93(7 Suppl 1):29. doi: 10.1016\/S0035-1040(07)79382-0","journal-title":"Rev Chir Orthop"},{"key":"1550_CR21","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/00003086-200204000-00047","volume":"397","author":"M Kamano","year":"2002","unstructured":"Kamano M, Honda Y, Kazuki K, Yasuda M (2002) Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Relat Res 397:403\u2013408","journal-title":"Clin Orthop Relat Res"},{"key":"1550_CR22","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1007\/s00104-003-0667-x","volume":"74","author":"C Dumont","year":"2003","unstructured":"Dumont C, Fuchs M, Folwaczny EK, Heuermann C, Sturmer KM (2003) Results of palmar T-plate osteosynthesis in unstable fractures of the distal radius. Chirurg 74:827\u2013833","journal-title":"Chirurg"},{"key":"1550_CR23","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1055\/s-2003-44840","volume":"128","author":"M Schutz","year":"2003","unstructured":"Schutz M, Kolbeck S, Spranger A, Arndt-Kolbeck M, Haas NP (2003) Palmar plating with the locking compression plate for dorsally displaced fractures of the distal radius\u2014first clinical experiences. Zentralbl Chir 128:997\u20131002","journal-title":"Zentralbl Chir"},{"key":"1550_CR24","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.jhsa.2003.09.015","volume":"29","author":"JL Orbay","year":"2004","unstructured":"Orbay JL, Fernandez DL (2004) Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am 29:96\u2013102","journal-title":"J Hand Surg Am"},{"key":"1550_CR25","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1007\/s00113-004-0794-y","volume":"107","author":"H Krimmer","year":"2004","unstructured":"Krimmer H, Pessenlehner C, Hasselbacher K, Meier M, Roth F, Meier R (2004) Palmar fixed angle plating systems for instable distal radius fractures. Unfallchirurg 107:460\u2013467","journal-title":"Unfallchirurg"},{"key":"1550_CR26","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1007\/s00590-003-0120-3","volume":"14","author":"A Prokop","year":"2004","unstructured":"Prokop A, Jubel A, Andermahr J, Rehm KE (2004) Do angle stable implants provide advantages? Treatment of distal radius fractures with the locking compression plate (LCP). Eur J Orthop Surg Traumatol 14:10\u201315","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"1550_CR27","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1016\/j.jhsa.2005.08.009","volume":"30","author":"Z Margaliot","year":"2005","unstructured":"Margaliot Z, Haase SC, Kotsis SV, Kim HM, Chung KC (2005) A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures. J Hand Surg Am 30:1185\u20131199","journal-title":"J Hand Surg Am"},{"key":"1550_CR28","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1007\/s00402-006-0191-9","volume":"126","author":"G Gruber","year":"2006","unstructured":"Gruber G, Bernhardt GA, Kohler G, Gruber K (2006) Surgical treatment of distal radius fractures with an angle fixed bar palmar plating system: a single center study of 102 patients over a 2-year period. Arch Orthop Trauma Surg 126:680\u2013685","journal-title":"Arch Orthop Trauma Surg"},{"key":"1550_CR29","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1302\/0301-620X.87B6.15539","volume":"87","author":"HJ Kreder","year":"2005","unstructured":"Kreder HJ, Hanel DP, Agel J, McKee M, Schemitsch EH, Trumble TE, Stephen D (2005) Indirect reduction and percutaneous fixation versus open reduction and internal fixation for displaced intra-articular fractures of the distal radius: a randomised, controlled trial. J Bone Joint Surg Br 87:829\u2013836","journal-title":"J Bone Joint Surg Br"},{"key":"1550_CR30","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/j.jhsb.2005.04.018","volume":"30","author":"M Koshimune","year":"2005","unstructured":"Koshimune M, Kamano M, Takamatsu K, Ohashi H (2005) A randomized comparison of locking and non-locking palmar plating for unstable Colles\u2019 fractures in the elderly. J Hand Surg Br 30:499\u2013503","journal-title":"J Hand Surg Br"},{"key":"1550_CR31","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.jhsa.2005.09.011","volume":"31","author":"DS Ruch","year":"2006","unstructured":"Ruch DS, Papadonikolakis A (2006) Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg Am 31:9\u201316","journal-title":"J Hand Surg Am"},{"key":"1550_CR32","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jhsa.2005.10.010","volume":"31","author":"TD Rozental","year":"2006","unstructured":"Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31:359\u2013365","journal-title":"J Hand Surg Am"},{"key":"1550_CR33","first-page":"714","volume":"73","author":"M Rampoldi","year":"2007","unstructured":"Rampoldi M, Marsico S (2007) Complications of volar plating of distal radius fractures. Acta Orthop Belg 73:714\u2013719","journal-title":"Acta Orthop Belg"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-014-1550-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00590-014-1550-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-014-1550-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,18]],"date-time":"2022-04-18T13:57:53Z","timestamp":1650290273000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00590-014-1550-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,10,2]]},"references-count":33,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2015,4]]}},"alternative-id":["1550"],"URL":"https:\/\/doi.org\/10.1007\/s00590-014-1550-9","relation":{},"ISSN":["1633-8065","1432-1068"],"issn-type":[{"value":"1633-8065","type":"print"},{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,10,2]]}}}