{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T02:30:23Z","timestamp":1790303423212,"version":"4.1.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2018,5,16]],"date-time":"2018-05-16T00:00:00Z","timestamp":1526428800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1007\/s00590-018-2224-9","type":"journal-article","created":{"date-parts":[[2018,5,16]],"date-time":"2018-05-16T06:52:33Z","timestamp":1526453553000},"page":"1581-1587","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Minimally invasive reduction and percutaneous posterior fixation of one-level traumatic thoraco-lumbar and lumbar spine fractures"],"prefix":"10.1007","volume":"28","author":[{"given":"Marco","family":"Tinelli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Friederike","family":"T\u00f6pfer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Kreinest","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Matschke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul A.","family":"Gr\u00fctzner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arnold J.","family":"Suda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,5,16]]},"reference":[{"issue":"4","key":"2224_CR1","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1007\/BF02221591","volume":"3","author":"F Magerl","year":"1994","unstructured":"Magerl F, Aebi M, Gertzbein SD, Harms J, Nazarian S (1994) A comprehensive classification of thoracic and lumbar injuries. Eur Spine J 3(4):184\u2013201","journal-title":"Eur Spine J"},{"issue":"2","key":"2224_CR2","doi-asserted-by":"publisher","first-page":"162","DOI":"10.2106\/00004623-199302000-00002","volume":"75","author":"RF McLain","year":"1993","unstructured":"McLain RF, Sparling E, Benson DR (1993) Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report. J Bone Joint Surg Am 75(2):162\u2013167","journal-title":"J Bone Joint Surg Am"},{"issue":"12","key":"2224_CR3","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1007\/s001320170009","volume":"30","author":"P Eysel","year":"2001","unstructured":"Eysel P, Hopf C, Furderer S (2001) Kyphotic deformation in fractures of the thoracic and lumbar spine. Der Orthopade 30(12):955\u2013964","journal-title":"Der Orthopade"},{"issue":"7","key":"2224_CR4","doi-asserted-by":"publisher","first-page":"231","DOI":"10.5435\/JAAOS-D-15-00638","volume":"26","author":"DH Alander","year":"2018","unstructured":"Alander DH, Cui S (2018) Percutaneous pedicle screw stabilization: surgical technique, fracture reduction, and review of current spine trauma applications. J Am Acad Orthop Surg 26(7):231\u2013240. https:\/\/doi.org\/10.5435\/JAAOS-D-15-00638","journal-title":"J Am Acad Orthop Surg"},{"issue":"7","key":"2224_CR5","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1097\/brs.0000000000001797","volume":"42","author":"SS Virk","year":"2017","unstructured":"Virk SS, Yu E (2017) The top 50 articles on minimally invasive spine surgery. Spine (Phila Pa 1976) 42(7):513\u2013519. https:\/\/doi.org\/10.1097\/brs.0000000000001797","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1065","key":"2224_CR6","doi-asserted-by":"publisher","first-page":"20150436","DOI":"10.1259\/bjr.20150436","volume":"89","author":"S Marcia","year":"2016","unstructured":"Marcia S, Saba L, Marras M, Suri JS, Calabria E, Masala S (2016) Percutaneous stabilization of lumbar spine: a literature review and new options in treating spine pain. Br J Radiol 89(1065):20150436. https:\/\/doi.org\/10.1259\/bjr.20150436","journal-title":"Br J Radiol"},{"key":"2224_CR7","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.clineuro.2015.05.016","volume":"135","author":"K Phan","year":"2015","unstructured":"Phan K, Rao PJ, Mobbs RJ (2015) Percutaneous versus open pedicle screw fixation for treatment of thoracolumbar fractures: systematic review and meta-analysis of comparative studies. Clin Neurol Neurosurg 135:85\u201392. https:\/\/doi.org\/10.1016\/j.clineuro.2015.05.016","journal-title":"Clin Neurol Neurosurg"},{"issue":"1","key":"2224_CR8","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1055\/s-0034-1396047","volume":"5","author":"JK Scheer","year":"2015","unstructured":"Scheer JK, Bakhsheshian J, Fakurnejad S, Oh T, Dahdaleh NS, Smith ZA (2015) Evidence-based medicine of traumatic thoracolumbar burst fractures: a systematic review of operative management across 20 years. Glob Spine J 5(1):73\u201382. https:\/\/doi.org\/10.1055\/s-0034-1396047","journal-title":"Glob Spine J"},{"key":"2224_CR9","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1097\/00003086-198410000-00014","volume":"189","author":"FP Magerl","year":"1984","unstructured":"Magerl FP (1984) Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res 189:125\u2013141","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"2224_CR10","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1007\/s00586-006-0262-1","volume":"16","author":"C Schizas","year":"2007","unstructured":"Schizas C, Theumann N, Kosmopoulos V (2007) Inserting pedicle screws in the upper thoracic spine without the use of fluoroscopy or image guidance. Is it safe? Eur Spine J 16(5):625\u2013629. https:\/\/doi.org\/10.1007\/s00586-006-0262-1","journal-title":"Eur Spine J"},{"issue":"2","key":"2224_CR11","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/0020-1383(81)90050-4","volume":"13","author":"DS Korres","year":"1981","unstructured":"Korres DS, Katsaros A, Pantazopoulos T, Hartofilakidis-Garofalidis G (1981) Double or multiple level fractures of the spine. Injury 13(2):147\u2013152","journal-title":"Injury"},{"key":"2224_CR12","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1097\/01.blo.0000068362.47147.a2","volume":"411","author":"DS Korres","year":"2003","unstructured":"Korres DS, Boscainos PJ, Papagelopoulos PJ, Psycharis I, Goudelis G, Nikolopoulos K (2003) Multiple level noncontiguous fractures of the spine. Clin Orthop Relat Res 411:95\u2013102. https:\/\/doi.org\/10.1097\/01.blo.0000068362.47147.a2","journal-title":"Clin Orthop Relat Res"},{"issue":"21 Suppl","key":"2224_CR13","doi-asserted-by":"publisher","first-page":"S235","DOI":"10.1097\/brs.0b013e3181f32734","volume":"35","author":"FC Oner","year":"2010","unstructured":"Oner FC, Wood KB, Smith JS, Shaffrey CI (2010) Therapeutic decision making in thoracolumbar spine trauma. Spine (Phila Pa 1976) 35(21 Suppl):S235\u2013S244. https:\/\/doi.org\/10.1097\/brs.0b013e3181f32734","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"2224_CR14","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s00113-010-1934-1","volume":"114","author":"AP Verheyden","year":"2011","unstructured":"Verheyden AP, Holzl A, Ekkerlein H, Gercek E, Hauck S, Josten C, Kandziora F, Katscher S, Knop C, Lehmann W, Meffert R, Muller CW, Partenheimer A, Schinkel C, Schleicher P, Schnake KJ, Scholz M, Ulrich C (2011) Recommendations for the treatment of thoracolumbar and lumbar spine injuries. Unfallchirurg 114(1):9\u201316. https:\/\/doi.org\/10.1007\/s00113-010-1934-1","journal-title":"Unfallchirurg"},{"issue":"1","key":"2224_CR15","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15(1):11\u201314","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"2224_CR16","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1097\/01.brs.0000148999.21492.53","volume":"30","author":"DY Kim","year":"2005","unstructured":"Kim DY, Lee SH, Chung SK, Lee HY (2005) Comparison of multifidus muscle atrophy and trunk extension muscle strength: percutaneous versus open pedicle screw fixation. Spine (Phila Pa 1976) 30(1):123\u2013129","journal-title":"Spine (Phila Pa 1976)"},{"issue":"8","key":"2224_CR17","doi-asserted-by":"publisher","first-page":"1194","DOI":"10.1007\/s00586-009-1010-0","volume":"18","author":"J Rodriguez-Vela","year":"2009","unstructured":"Rodriguez-Vela J, Lobo-Escolar A, Joven-Aliaga E, Herrera A, Vicente J, Sunen E, Loste A, Tabuenca A (2009) Perioperative and short-term advantages of mini-open approach for lumbar spinal fusion. Eur Spine J 18(8):1194\u20131201. https:\/\/doi.org\/10.1007\/s00586-009-1010-0","journal-title":"Eur Spine J"},{"issue":"4","key":"2224_CR18","doi-asserted-by":"publisher","first-page":"374","DOI":"10.4103\/0019-5413.37003","volume":"41","author":"OI Schmidt","year":"2007","unstructured":"Schmidt OI, Strasser S, Kaufmann V, Strasser E, Gahr RH (2007) Role of early minimal-invasive spine fixation in acute thoracic and lumbar spine trauma. Indian J Orthop 41(4):374\u2013380. https:\/\/doi.org\/10.4103\/0019-5413.37003","journal-title":"Indian J Orthop"},{"issue":"2","key":"2224_CR19","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1007\/s00586-009-1191-6","volume":"19","author":"S Fan","year":"2010","unstructured":"Fan S, Hu Z, Zhao F, Zhao X, Huang Y, Fang X (2010) Multifidus muscle changes and clinical effects of one-level posterior lumbar interbody fusion: minimally invasive procedure versus conventional open approach. Eur Spine J 19(2):316\u2013324. https:\/\/doi.org\/10.1007\/s00586-009-1191-6","journal-title":"Eur Spine J"},{"issue":"3","key":"2224_CR20","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1007\/s00586-012-2476-8","volume":"22","author":"TM Heintel","year":"2013","unstructured":"Heintel TM, Berglehner A, Meffert R (2013) Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures: a prospective trial. Eur Spine J 22(3):495\u2013502. https:\/\/doi.org\/10.1007\/s00586-012-2476-8","journal-title":"Eur Spine J"},{"issue":"Suppl 1","key":"2224_CR21","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/s00586-009-0989-6","volume":"18","author":"M Palmisani","year":"2009","unstructured":"Palmisani M, Gasbarrini A, Brodano GB, De Iure F, Cappuccio M, Boriani L, Amendola L, Boriani S (2009) Minimally invasive percutaneous fixation in the treatment of thoracic and lumbar spine fractures. Eur Spine J 18(Suppl 1):71\u201374. https:\/\/doi.org\/10.1007\/s00586-009-0989-6","journal-title":"Eur Spine J"},{"issue":"Suppl 4","key":"2224_CR22","doi-asserted-by":"publisher","first-page":"S75","DOI":"10.1016\/S0020-1383(15)30022-X","volume":"46","author":"M Loibl","year":"2015","unstructured":"Loibl M, Korsun M, Reiss J, Gueorguiev B, Nerlich M, Neumann C, Baumann F (2015) Spinal fracture reduction with a minimal-invasive transpedicular Schanz Screw system: clinical and radiological one-year follow-up. Injury 46(Suppl 4):S75\u2013S82. https:\/\/doi.org\/10.1016\/S0020-1383(15)30022-X","journal-title":"Injury"},{"issue":"2","key":"2224_CR23","doi-asserted-by":"publisher","first-page":"E2","DOI":"10.3171\/2013.6.FOCUS13176","volume":"35","author":"AJ Grossbach","year":"2013","unstructured":"Grossbach AJ, Dahdaleh NS, Abel TJ, Woods GD, Dlouhy BJ, Hitchon PW (2013) Flexion-distraction injuries of the thoracolumbar spine: open fusion versus percutaneous pedicle screw fixation. Neurosurg Focus 35(2):E2. https:\/\/doi.org\/10.3171\/2013.6.FOCUS13176","journal-title":"Neurosurg Focus"},{"issue":"Suppl 4","key":"2224_CR24","doi-asserted-by":"publisher","first-page":"S63","DOI":"10.1016\/S0020-1383(15)30020-6","volume":"46","author":"S Fitschen-Oestern","year":"2015","unstructured":"Fitschen-Oestern S, Scheuerlein F, Weuster M, Klueter T, Menzdorf L, Varoga D, Kopetsch C, Mueller M, van der Horst A, Seekamp A, Behrendt P, Lippross S (2015) Reduction and retention of thoracolumbar fractures by minimally invasive stabilisation versus open posterior instrumentation. Injury 46(Suppl 4):S63\u2013S70. https:\/\/doi.org\/10.1016\/S0020-1383(15)30020-6","journal-title":"Injury"},{"issue":"6","key":"2224_CR25","doi-asserted-by":"publisher","first-page":"1781","DOI":"10.1007\/s00586-015-4163-z","volume":"25","author":"TM Chapman","year":"2016","unstructured":"Chapman TM, Blizzard DJ, Brown CR (2016) CT accuracy of percutaneous versus open pedicle screw techniques: a series of 1609 screws. Eur Spine J 25(6):1781\u20131786. https:\/\/doi.org\/10.1007\/s00586-015-4163-z","journal-title":"Eur Spine J"},{"issue":"12","key":"2224_CR26","doi-asserted-by":"publisher","first-page":"1751","DOI":"10.1016\/j.spinee.2013.03.042","volume":"13","author":"HS Oh","year":"2013","unstructured":"Oh HS, Kim JS, Lee SH, Liu WC, Hong SW (2013) Comparison between the accuracy of percutaneous and open pedicle screw fixations in lumbosacral fusion. Spine J 13(12):1751\u20131757. https:\/\/doi.org\/10.1016\/j.spinee.2013.03.042","journal-title":"Spine J"},{"key":"2224_CR27","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-016-4911-8","author":"M Kreinest","year":"2016","unstructured":"Kreinest M, Rillig J, Grutzner PA, Kuffer M, Tinelli M, Matschke S (2016) Analysis of complications and perioperative data after open or percutaneous dorsal instrumentation following traumatic spinal fracture of the thoracic and lumbar spine: a retrospective cohort study including 491 patients. Eur Spine J. https:\/\/doi.org\/10.1007\/s00586-016-4911-8","journal-title":"Eur Spine J"},{"issue":"4","key":"2224_CR28","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/j.otsr.2014.03.015","volume":"100","author":"M Tinelli","year":"2014","unstructured":"Tinelli M, Matschke S, Adams M, Grutzner PA, Munzberg M, Suda AJ (2014) Correct positioning of pedicle screws with a percutaneous minimal invasive system in spine trauma. Orthop Traumatol Surg Res 100(4):389\u2013393. https:\/\/doi.org\/10.1016\/j.otsr.2014.03.015","journal-title":"Orthop Traumatol Surg Res"},{"issue":"1","key":"2224_CR29","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/s00113-010-1939-9","volume":"114","author":"TR Blattert","year":"2011","unstructured":"Blattert TR, Katscher S, Josten C (2011) Percutaneous techniques in the thoracic and lumbar spine. Der Unfallchirurg 114(1):17\u201325. https:\/\/doi.org\/10.1007\/s00113-010-1939-9","journal-title":"Der Unfallchirurg"},{"issue":"5","key":"2224_CR30","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1097\/BSD.0b013e318218a5ef","volume":"25","author":"IH Lieberman","year":"2012","unstructured":"Lieberman IH, Hardenbrook MA, Wang JC, Guyer RD (2012) Assessment of pedicle screw placement accuracy, procedure time, and radiation exposure using a miniature robotic guidance system. J Spinal Disord Tech 25(5):241\u2013248. https:\/\/doi.org\/10.1097\/BSD.0b013e318218a5ef","journal-title":"J Spinal Disord Tech"},{"issue":"4","key":"2224_CR31","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/j.spinee.2011.02.007","volume":"11","author":"Y Park","year":"2011","unstructured":"Park Y, Ha JW, Lee YT, Sung NY (2011) Cranial facet joint violations by percutaneously placed pedicle screws adjacent to a minimally invasive lumbar spinal fusion. Spine J 11(4):295\u2013302. https:\/\/doi.org\/10.1016\/j.spinee.2011.02.007","journal-title":"Spine J"},{"issue":"4","key":"2224_CR32","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1007\/s00113-005-1037-6","volume":"109","author":"R Grass","year":"2006","unstructured":"Grass R, Biewener A, Dickopf A, Rammelt S, Heineck J, Zwipp H (2006) Percutaneous dorsal versus open instrumentation for fractures of the thoracolumbar border. A comparative, prospective study. Der Unfallchirurg 109(4):297\u2013305. https:\/\/doi.org\/10.1007\/s00113-005-1037-6","journal-title":"Der Unfallchirurg"},{"issue":"2","key":"2224_CR33","doi-asserted-by":"publisher","first-page":"117","DOI":"10.3171\/spi.2006.5.2.117","volume":"5","author":"PW Hitchon","year":"2006","unstructured":"Hitchon PW, Torner J, Eichholz KM, Beeler SN (2006) Comparison of anterolateral and posterior approaches in the management of thoracolumbar burst fractures. J Neurosurg Spine 5(2):117\u2013125. https:\/\/doi.org\/10.3171\/spi.2006.5.2.117","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"2224_CR34","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1007\/s00113-008-1524-7","volume":"112","author":"M Reinhold","year":"2009","unstructured":"Reinhold M, Knop C, Beisse R, Audige L, Kandziora F, Pizanis A, Pranzl R, Gercek E, Schultheiss M, Weckbach A, Buhren V, Blauth M (2009) Operative treatment of traumatic fractures of the thoracic and lumbar spinal column. Part I: epidemiology. Der Unfallchirurg 112(1):33\u201345. https:\/\/doi.org\/10.1007\/s00113-008-1524-7","journal-title":"Der Unfallchirurg"},{"issue":"1","key":"2224_CR35","doi-asserted-by":"publisher","first-page":"E9","DOI":"10.3171\/2014.5.FOCUS14108","volume":"37","author":"SS Dhall","year":"2014","unstructured":"Dhall SS, Wadhwa R, Wang MY, Tien-Smith A, Mummaneni PV (2014) Traumatic thoracolumbar spinal injury: an algorithm for minimally invasive surgical management. Neurosurg Focus 37(1):E9. https:\/\/doi.org\/10.3171\/2014.5.FOCUS14108","journal-title":"Neurosurg Focus"},{"issue":"1","key":"2224_CR36","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.spinee.2012.10.041","volume":"14","author":"KB Wood","year":"2014","unstructured":"Wood KB, Li W, Lebl DR, Ploumis A (2014) Management of thoracolumbar spine fractures. Spine J 14(1):145\u2013164. https:\/\/doi.org\/10.1016\/j.spinee.2012.10.041","journal-title":"Spine J"},{"issue":"5","key":"2224_CR37","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/j.otsr.2009.06.001","volume":"95","author":"B Blondel","year":"2009","unstructured":"Blondel B, Fuentes S, Metellus P, Adetchessi T, Pech-Gourg G, Dufour H (2009) Severe thoracolumbar osteoporotic burst fractures: treatment combining open kyphoplasty and short-segment fixation. Orthop Traumatol Surg Res: OTSR 95(5):359\u2013364. https:\/\/doi.org\/10.1016\/j.otsr.2009.06.001","journal-title":"Orthop Traumatol Surg Res: OTSR"},{"issue":"Suppl 1","key":"2224_CR38","doi-asserted-by":"publisher","first-page":"S159","DOI":"10.1007\/s00590-013-1266-2","volume":"24","author":"M Takami","year":"2014","unstructured":"Takami M, Yamada H, Nohda K, Yoshida M (2014) A minimally invasive surgery combining temporary percutaneous pedicle screw fixation without fusion and vertebroplasty with transpedicular intracorporeal hydroxyapatite blocks grafting for fresh thoracolumbar burst fractures: prospective study. Eur J Orthop Surg Traumatol 24(Suppl 1):S159\u2013S165. https:\/\/doi.org\/10.1007\/s00590-013-1266-2","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"4","key":"2224_CR39","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1016\/j.injury.2010.03.025","volume":"43","author":"F Hartmann","year":"2012","unstructured":"Hartmann F, Gercek E, Leiner L, Rommens PM (2012) Kyphoplasty as an alternative treatment of traumatic thoracolumbar burst fractures Magerl type A3. Injury 43(4):409\u2013415. https:\/\/doi.org\/10.1016\/j.injury.2010.03.025","journal-title":"Injury"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00590-018-2224-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-018-2224-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-018-2224-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,23]],"date-time":"2022-08-23T19:17:53Z","timestamp":1661282273000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00590-018-2224-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5,16]]},"references-count":39,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["2224"],"URL":"https:\/\/doi.org\/10.1007\/s00590-018-2224-9","relation":{},"ISSN":["1633-8065","1432-1068"],"issn-type":[{"value":"1633-8065","type":"print"},{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,5,16]]},"assertion":[{"value":"26 March 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 May 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 May 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors have no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study was approved by the local ethical committee Ethik-Kommission der Landes\u00e4rztekammer Rheinland-Pfalz, Germany.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}