{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T09:14:25Z","timestamp":1766049265270,"version":"3.37.3"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2019,12,21]],"date-time":"2019-12-21T00:00:00Z","timestamp":1576886400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,12,21]],"date-time":"2019-12-21T00:00:00Z","timestamp":1576886400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"published-print":{"date-parts":[[2020,5]]},"DOI":"10.1007\/s00590-019-02602-4","type":"journal-article","created":{"date-parts":[[2019,12,21]],"date-time":"2019-12-21T11:02:21Z","timestamp":1576926141000},"page":"643-651","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Carbon\/PEEK nails: a case\u2013control study of 22 cases"],"prefix":"10.1007","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1276-0624","authenticated-orcid":false,"given":"Federico","family":"Sacchetti","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lorenzo","family":"Andreani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michele","family":"Palazzuolo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephane","family":"Cherix","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Enrico","family":"Bonicoli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elisabetta","family":"Neri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rodolfo","family":"Capanna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,12,21]]},"reference":[{"issue":"2","key":"2602_CR1","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1177\/0956797614551162","volume":"209","author":"M Akay","year":"1995","unstructured":"Akay M, Asian N (1995) An estimation of fatigue life for a carbon fibre\/poly ether ether ketone hip joint prosthesis. Proc Inst Mech Eng 209(2):93\u2013103. https:\/\/doi.org\/10.1177\/0956797614551162","journal-title":"Proc Inst Mech Eng"},{"issue":"1","key":"2602_CR2","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1016\/S0360-3016(97)00587-7","volume":"40","author":"AS Allal","year":"1998","unstructured":"Allal AS, Richter M, Russo M, Rouzaud M, Dulguerov P, Kurtz JM (1998) Dose variation at bone\/titanium interfaces using titanium hollow screw osseointegrating reconstruction plates. Int J Radiat Oncol Biol Phys 40(1):215\u2013219. https:\/\/doi.org\/10.1016\/S0360-3016(97)00587-7","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"SUPPL. 2","key":"2602_CR3","doi-asserted-by":"publisher","first-page":"S16","DOI":"10.1016\/j.injury.2014.04.004","volume":"45","author":"P Augat","year":"2014","unstructured":"Augat P, Morgan EF, Lujan TJ, Macgillivray TJ, Cheung WH (2014) Imaging techniques for the assessment of fracture repair. Injury 45(SUPPL. 2):S16\u2013S22. https:\/\/doi.org\/10.1016\/j.injury.2014.04.004","journal-title":"Injury"},{"key":"2602_CR4","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.jmbbm.2014.03.008","volume":"35","author":"ZS Bagheri","year":"2014","unstructured":"Bagheri ZS, El Sawi I, Bougherara H, Zdero R (2014) Biomechanical fatigue analysis of an advanced new carbon fiber\/flax\/epoxy plate for bone fracture repair using conventional fatigue tests and thermography. J Mech Behav Biomed Mater 35:27\u201338. https:\/\/doi.org\/10.1016\/j.jmbbm.2014.03.008","journal-title":"J Mech Behav Biomed Mater"},{"issue":"3","key":"2602_CR5","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1106\/BKLQ-E2YG-D2LA-RG3R","volume":"15","author":"KP Baidya","year":"2001","unstructured":"Baidya KP, Ramakrishna S, Rahman M, Ritchie A (2001) Quantitative radiographic analysis of fiber reinforced polymer composites. J Biomater Appl 15(3):279\u2013289. https:\/\/doi.org\/10.1106\/BKLQ-E2YG-D2LA-RG3R","journal-title":"J Biomater Appl"},{"issue":"9","key":"2602_CR6","doi-asserted-by":"publisher","first-page":"e213","DOI":"10.1097\/BOT.0b013e318282e692","volume":"27","author":"M Bhandari","year":"2013","unstructured":"Bhandari M, Chiavaras M, Ayeni O, Chakraverrty R, Parasu N, Choudur H et al (2013) Assessment of radiographic fracture healing in patients with operatively treated femoral neck fractures. J Orthop Trauma 27(9):e213\u2013e219. https:\/\/doi.org\/10.1097\/BOT.0b013e318282e692","journal-title":"J Orthop Trauma"},{"key":"2602_CR7","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.wear.2016.12.010","volume":"374\u2013375","author":"CL Brockett","year":"2017","unstructured":"Brockett CL, Carbone S, Fisher J, Jennings LM (2017) PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: an experimental wear study. Wear 374\u2013375:86\u201391. https:\/\/doi.org\/10.1016\/j.wear.2016.12.010","journal-title":"Wear"},{"issue":"8","key":"2602_CR8","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1016\/0142-9612(90)90075-2","volume":"11","author":"SA Brown","year":"1990","unstructured":"Brown SA, Hastings RS, Mason JJ, Moet A (1990) Characterization of short-fibre reinforced thermoplastics for fracture fixation devices. Biomaterials 11(8):541\u2013547. https:\/\/doi.org\/10.1016\/0142-9612(90)90075-2","journal-title":"Biomaterials"},{"issue":"S6","key":"2602_CR9","doi-asserted-by":"publisher","first-page":"S36","DOI":"10.1016\/j.injury.2014.10.020","volume":"45","author":"M Caforio","year":"2014","unstructured":"Caforio M, Perugia D, Colombo M, Calori GM, Maniscalco P (2014) Preliminary experience with Piccolo Composite\u2122, a radiolucent distal fibula plate, in ankle fractures. Injury 45(S6):S36\u2013S38. https:\/\/doi.org\/10.1016\/j.injury.2014.10.020","journal-title":"Injury"},{"issue":"8","key":"2602_CR10","doi-asserted-by":"publisher","first-page":"1079","DOI":"10.1007\/s00256-013-1605-8","volume":"42","author":"MM Chiavaras","year":"2013","unstructured":"Chiavaras MM, Bains S, Choudur H, Parasu N, Jacobson J, Ayeni O et al (2013) The Radiographic Union Score for Hip (RUSH): the use of a checklist to evaluate hip fracture healing improves agreement between radiologists and orthopedic surgeons. Skelet Radiol 42(8):1079\u20131088. https:\/\/doi.org\/10.1007\/s00256-013-1605-8","journal-title":"Skelet Radiol"},{"issue":"1","key":"2602_CR11","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1186\/s40634-015-0030-4","volume":"2","author":"A Diffo Kaze","year":"2015","unstructured":"Diffo Kaze A, Maas S, Waldmann D, Zilian A, Dueck K, Pape D (2015) Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy. J Exp Orthop 2(1):14. https:\/\/doi.org\/10.1186\/s40634-015-0030-4","journal-title":"J Exp Orthop"},{"issue":"7","key":"2602_CR12","doi-asserted-by":"publisher","first-page":"1367","DOI":"10.1007\/s00590-019-02446-y","volume":"29","author":"C Errani","year":"2019","unstructured":"Errani C, Bazzocchi A, Spinnato P, Facchini G, Campanacci L, Rossi G et al (2019) What\u2019 s new in management of bone metastases? Eur J Orthop Surg Traumatol 29(7):1367\u20131375. https:\/\/doi.org\/10.1007\/s00590-019-02446-y","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"2","key":"2602_CR13","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1007\/s00590-016-1857-9","volume":"27","author":"C Errani","year":"2017","unstructured":"Errani C, Mavrogenis AF, Cevolani L, Spinelli S, Piccioli A, Maccauro G et al (2017) Treatment for long bone metastases based on a systematic literature review. Eur J Orthop Surg Traumatol 27(2):205\u2013211","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"6","key":"2602_CR14","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1016\/j.medengphy.2012.07.016","volume":"35","author":"EM Feerick","year":"2013","unstructured":"Feerick EM, Kennedy J, Mullett H, FitzPatrick D, McGarry P (2013) Investigation of metallic and carbon fibre PEEK fracture fixation devices for three-part proximal humeral fractures. Med Eng Phys 35(6):712\u2013722. https:\/\/doi.org\/10.1016\/j.medengphy.2012.07.016","journal-title":"Med Eng Phys"},{"issue":"6","key":"2602_CR15","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1007\/s00590-017-1986-9","volume":"27","author":"D Filippiadis","year":"2017","unstructured":"Filippiadis D, Mavrogenis AF, Mazioti A (2017) Metastatic bone disease from breast cancer: a review of minimally invasive techniques for diagnosis and treatment. Eur J Orthop Surg Traumatol 27(6):729\u2013736","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"15","key":"2602_CR16","doi-asserted-by":"publisher","first-page":"2661","DOI":"10.1016\/S0142-9612(03)00065-6","volume":"24","author":"K Fujihara","year":"2003","unstructured":"Fujihara K, Huang ZM, Ramakrishna S, Satknanantham K, Hamada H (2003) Performance study of braided carbon\/PEEK composite compression bone plates. Biomaterials 24(15):2661\u20132667. https:\/\/doi.org\/10.1016\/S0142-9612(03)00065-6","journal-title":"Biomaterials"},{"issue":"11","key":"2602_CR17","doi-asserted-by":"publisher","first-page":"1390","DOI":"10.1016\/j.injury.2011.05.026","volume":"42","author":"S Haque","year":"2011","unstructured":"Haque S, Siddiqui G (2011) Re: The invisible nail: a technique report of treatment of a pathological humerus fracture with a radiolucent intramedullary nail. Injury 42(11):1390\u20131391. https:\/\/doi.org\/10.1016\/j.injury.2011.05.026","journal-title":"Injury"},{"issue":"1","key":"2602_CR18","doi-asserted-by":"publisher","first-page":"23","DOI":"10.15438\/rr.v4i1.55","volume":"4","author":"R Hillock","year":"2014","unstructured":"Hillock R, Howard S (2014) Utility of carbon fiber implants in orthopedic surgery: literature review. Reconstruct Rev 4(1):23\u201332. https:\/\/doi.org\/10.15438\/rr.v4i1.55","journal-title":"Reconstruct Rev"},{"issue":"2","key":"2602_CR19","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1002\/jbm.b.10068","volume":"67","author":"GI Howling","year":"2003","unstructured":"Howling GI, Sakoda H, Antonarulrajah A, Marrs H, Stewart TD, Appleyard S et al (2003) Biological response to wear debris generated in carbon based composites as potential bearing surfaces for artificial hip joints. J Biomed Mater Res Part B Appl Biomater 67(2):758\u2013764. https:\/\/doi.org\/10.1002\/jbm.b.10068","journal-title":"J Biomed Mater Res Part B Appl Biomater"},{"key":"2602_CR20","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1002\/jbm.820260202","volume":"26","author":"KA Jockiseh","year":"1992","unstructured":"Jockiseh KA, Brown SA, Bauer TW, Merritt K (1992) Biological response to chopped-carbon-fiber reinforced peek. J Biomed Mater Res 26:133\u2013146","journal-title":"J Biomed Mater Res"},{"issue":"3","key":"2602_CR21","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1007\/s00590-016-1891-7","volume":"27","author":"JC Katthagen","year":"2017","unstructured":"Katthagen JC, Ellwein A, Lutz O, Voigt C, Lill H (2017) Outcomes of proximal humeral fracture fixation with locked CFR-PEEK plating. Eur J Orthop Surg Traumatol 27(3):351\u2013358. https:\/\/doi.org\/10.1007\/s00590-016-1891-7","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"4","key":"2602_CR22","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1002\/jmri.22313","volume":"32","author":"KM Koch","year":"2010","unstructured":"Koch KM, Hargreaves BA, Pauly KB, Chen W, Gold GE, King KF (2010) Magnetic resonance imaging near metal implants. J Magn Reson Imaging JMRI 32(4):773\u2013787. https:\/\/doi.org\/10.1002\/jmri.22313","journal-title":"J Magn Reson Imaging JMRI"},{"issue":"3","key":"2602_CR23","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1002\/jmri.23991","volume":"38","author":"MF Koff","year":"2013","unstructured":"Koff MF, Shah P, Koch KM, Potter HG (2013) Quantifying image distortion of orthopedic materials in magnetic resonance imaging. J Magn Reson Imaging 38(3):610\u2013618. https:\/\/doi.org\/10.1002\/jmri.23991","journal-title":"J Magn Reson Imaging"},{"issue":"32","key":"2602_CR24","doi-asserted-by":"publisher","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","volume":"28","author":"SM Kurtz","year":"2007","unstructured":"Kurtz SM, Devine JN (2007) PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 28(32):4845\u20134869. https:\/\/doi.org\/10.1016\/j.biomaterials.2007.07.013","journal-title":"Biomaterials"},{"key":"2602_CR25","doi-asserted-by":"publisher","first-page":"33","DOI":"10.4137\/CMAMD.S20354","volume":"8","author":"CS Li","year":"2014","unstructured":"Li CS, Vannabouathong C, Sprague S, Bhandari M (2014) The use of carbon-fiber-reinforced (CFR) peek material in orthopedic implants: a systematic review. Clin Med Insights: Arthritis Musculoskel Disorders 8:33\u201345. https:\/\/doi.org\/10.4137\/CMAMD.S20354","journal-title":"Clin Med Insights: Arthritis Musculoskel Disorders"},{"issue":"2\u20133","key":"2602_CR26","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1007\/s00402-002-0465-9","volume":"123","author":"H Lill","year":"2003","unstructured":"Lill H, Hepp P, Korner J, Kassi JP, Verheyden AP, Josten C, Duda GN (2003) Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens. Arch Orthop Trauma Surg 123(2\u20133):74\u201381. https:\/\/doi.org\/10.1007\/s00402-002-0465-9","journal-title":"Arch Orthop Trauma Surg"},{"key":"2602_CR27","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1007\/s00590-014-1421-4","volume":"24","author":"AF Mavrogenis","year":"2014","unstructured":"Mavrogenis AF, Vottis C (2014) PEEK rod systems for the spine. Eur J Orthop Surg Traumatol 24:111\u2013116","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2602_CR28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.brainresrev.2006.12.007","volume":"2014","author":"S Morshed","year":"2014","unstructured":"Morshed S (2014) Current options for determining fracture union. Adv Med 2014:1\u201312. https:\/\/doi.org\/10.1016\/j.brainresrev.2006.12.007","journal-title":"Adv Med"},{"key":"2602_CR29","doi-asserted-by":"publisher","first-page":"S55","DOI":"10.1016\/S0020-1383(17)30659-9","volume":"48","author":"A Piccioli","year":"2017","unstructured":"Piccioli A, Piana R, Lisanti M, Di Martino A, Rossi B, Camnasio F et al (2017) Carbon-fiber reinforced intramedullary nailing in musculoskeletal tumor surgery: a national multicentric experience of the Italian Orthopaedic Society (SIOT) Bone Metastasis Study Group. Injury 48:S55\u2013S59. https:\/\/doi.org\/10.1016\/S0020-1383(17)30659-9","journal-title":"Injury"},{"issue":"5","key":"2602_CR30","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/0266-4356(89)90076-4","volume":"27","author":"KR Postlethwaite","year":"1989","unstructured":"Postlethwaite KR, Philips JG, Booth S, Shaw J, Slater A (1989) The effects of small plate osteosynthesis on postoperative radiotherapy. Br J Oral Maxillofac Surg 27(5):375\u2013378. https:\/\/doi.org\/10.1016\/0266-4356(89)90076-4","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"8","key":"2602_CR31","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1016\/j.jse.2014.12.028","volume":"24","author":"B Schliemann","year":"2015","unstructured":"Schliemann B, Hartensuer R, Koch T, Theisen C, Raschke MJ, K\u00f6sters C, Weimann A (2015) Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate. J Shoulder Elbow Surg 24(8):1282\u20131288. https:\/\/doi.org\/10.1016\/j.jse.2014.12.028","journal-title":"J Shoulder Elbow Surg"},{"issue":"1","key":"2602_CR32","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1007\/s10856-008-3558-3","volume":"20","author":"SC Scholes","year":"2009","unstructured":"Scholes SC, Unsworth A (2009) Wear studies on the likely performance of CFR-PEEK\/CoCrMo for use as artificial joint bearing materials. J Mater Sci Mater Med 20(1):163\u2013170. https:\/\/doi.org\/10.1007\/s10856-008-3558-3","journal-title":"J Mater Sci Mater Med"},{"key":"2602_CR33","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1097\/00003086-198810000-00022","volume":"235","author":"HB Skinner","year":"1988","unstructured":"Skinner HB (1988) Composite technology for total hip arthroplasty. Clin Orthop Relat Res 235:224\u2013236. https:\/\/doi.org\/10.1097\/00003086-198810000-00022","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"2602_CR34","doi-asserted-by":"publisher","first-page":"874","DOI":"10.1007\/s00586-017-5258-5","volume":"27","author":"B Stefano","year":"2018","unstructured":"Stefano B, Tedesco G, Ming L, Ghermandi R, Amichetti M, Fossati P, Krengli M, Mavilla L, Gasbarrini A (2018) Carbon-fiber-reinforced PEEK fixation system in the treatment of spine tumors: a preliminary report. Eur Spine J 27(4):874\u2013881","journal-title":"Eur Spine J"},{"key":"2602_CR35","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.jmbbm.2012.09.013","volume":"17","author":"EL Steinberg","year":"2012","unstructured":"Steinberg EL, Rath E, Shlaifer A, Chechik O, Maman E, Salai M (2012) Carbon fiber reinforced PEEK Optima-A composite material biomechanical properties and wear\/debris characteristics of CF-PEEK composites for orthopedic trauma implants. J Mech Behav Biomed Mater 17:221\u2013228. https:\/\/doi.org\/10.1016\/j.jmbbm.2012.09.013","journal-title":"J Mech Behav Biomed Mater"},{"issue":"4","key":"2602_CR36","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s10195-014-0311-1","volume":"15","author":"L Tarallo","year":"2014","unstructured":"Tarallo L, Mugnai R, Adani R, Zambianchi F, Catani F (2014) A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases. J Orthop Traumatol 15(4):277\u2013283. https:\/\/doi.org\/10.1007\/s10195-014-0311-1","journal-title":"J Orthop Traumatol"},{"issue":"3","key":"2602_CR37","doi-asserted-by":"publisher","first-page":"323","DOI":"10.21037\/jss.2017.06.20","volume":"3","author":"G Tedesco","year":"2017","unstructured":"Tedesco G, Gasbarrini A, Bandiera S, Ghermandi R, Boriani S (2017) Composite PEEK\/Carbon fiber implants can increase the effectiveness of radiotherapy in the management of spine tumors. J Spine Surg 3(3):323\u2013329. https:\/\/doi.org\/10.21037\/jss.2017.06.20","journal-title":"J Spine Surg"},{"issue":"11","key":"2602_CR38","doi-asserted-by":"publisher","first-page":"4296","DOI":"10.1016\/j.actbio.2010.06.002","volume":"6","author":"S Utzschneider","year":"2010","unstructured":"Utzschneider S, Becker F, Grupp TM, Sievers B, Paulus A, Gottschalk O, Jansson V (2010) Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo. Acta Biomater 6(11):4296\u20134304. https:\/\/doi.org\/10.1016\/j.actbio.2010.06.002","journal-title":"Acta Biomater"},{"issue":"5","key":"2602_CR39","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1177\/1071100715625291","volume":"37","author":"WK Wilson","year":"2015","unstructured":"Wilson WK, Morris RP, Ward AJ, Carayannopoulos NL, Panchbhavi VK (2015) Torsional failure of carbon fiber composite plates versus stainless steel plates for comminuted distal fibula fractures. Foot Ankle Int 37(5):548\u2013553. https:\/\/doi.org\/10.1177\/1071100715625291","journal-title":"Foot Ankle Int"},{"issue":"4","key":"2602_CR40","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1120\/jacmp.v13i4.3821","volume":"13","author":"N Xin-Ye","year":"2012","unstructured":"Xin-Ye N, Xiao-Bin T, Chang-Ran G, Da C (2012) The prospect of carbon fiber implants in radiotherapy. J Appl Clin Med Phys 13(4):152\u2013159. https:\/\/doi.org\/10.1120\/jacmp.v13i4.3821","journal-title":"J Appl Clin Med Phys"},{"issue":"9","key":"2602_CR41","doi-asserted-by":"publisher","first-page":"1317","DOI":"10.1007\/s00256-015-2158-9","volume":"44","author":"MN Zimel","year":"2015","unstructured":"Zimel MN, Hwang S, Riedel ER, Healey JH (2015) Carbon fiber intramedullary nails reduce artifact in postoperative advanced imaging. Skelet Radiol 44(9):1317\u20131325. https:\/\/doi.org\/10.1007\/s00256-015-2158-9","journal-title":"Skelet Radiol"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-019-02602-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00590-019-02602-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-019-02602-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,20]],"date-time":"2020-12-20T00:27:11Z","timestamp":1608424031000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00590-019-02602-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,21]]},"references-count":41,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,5]]}},"alternative-id":["2602"],"URL":"https:\/\/doi.org\/10.1007\/s00590-019-02602-4","relation":{},"ISSN":["1633-8065","1432-1068"],"issn-type":[{"type":"print","value":"1633-8065"},{"type":"electronic","value":"1432-1068"}],"subject":[],"published":{"date-parts":[[2019,12,21]]},"assertion":[{"value":"17 October 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 December 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Each author certifies that he or she has no commercial associations (e.g. consultancies, stock ownership, equity interest, patent\/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}