{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T17:19:15Z","timestamp":1794590355775,"version":"4.9.1"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2020,6,15]],"date-time":"2020-06-15T00:00:00Z","timestamp":1592179200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,6,15]],"date-time":"2020-06-15T00:00:00Z","timestamp":1592179200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"published-print":{"date-parts":[[2020,12]]},"DOI":"10.1007\/s00590-020-02717-z","type":"journal-article","created":{"date-parts":[[2020,6,17]],"date-time":"2020-06-17T17:05:52Z","timestamp":1592413552000},"page":"1417-1420","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["High incidence of \u201cin\u2013out\u2013in\u201d posterosuperior screws after cannulated screw fixation of femoral neck fractures"],"prefix":"10.1007","volume":"30","author":[{"given":"Brandon J.","family":"Yuan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamad Tayseer","family":"Shamaa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William R.","family":"Aibinder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8262-4065","authenticated-orcid":false,"given":"Joshua A.","family":"Parry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William W.","family":"Cross","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan D.","family":"Barlow","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen A.","family":"Sems","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,6,15]]},"reference":[{"key":"2717_CR1","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/0020-1383(95)00157-3","volume":"27","author":"FY Chiu","year":"1996","unstructured":"Chiu FY, Lo WH, Yu CT et al (1996) Percutaneous pinning in undisplaced subcapital femoral neck fractures. Injury 27:53\u201355. https:\/\/doi.org\/10.1016\/0020-1383(95)00157-3","journal-title":"Injury"},{"key":"2717_CR2","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1016\/j.injury.2008.05.023","volume":"40","author":"C Rogmark","year":"2009","unstructured":"Rogmark C, Flensburg L, Fredin H (2009) Undisplaced femoral neck fractures\u2014no problems? A consecutive study of 224 patients treated with internal fixation. Injury 40:274\u2013276. https:\/\/doi.org\/10.1016\/j.injury.2008.05.023","journal-title":"Injury"},{"key":"2717_CR3","doi-asserted-by":"publisher","first-page":"1383","DOI":"10.1007\/s00590-019-02460-0","volume":"29","author":"MSA Shehata","year":"2019","unstructured":"Shehata MSA, Aboelnas MM, Abdulkarim AN et al (2019) Sliding hip screws versus cancellous screws for femoral neck fractures: a systematic review and meta-analysis. Eur J Orthop Surg Traumatol 29:1383\u20131393","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2717_CR4","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/S0020-1383(03)00059-7","volume":"35","author":"VT Selvan","year":"2004","unstructured":"Selvan VT, Oakley MJ, Rangan A, Al-Lami MK (2004) Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: a biomechanical study. Injury 35:136\u2013141. https:\/\/doi.org\/10.1016\/S0020-1383(03)00059-7","journal-title":"Injury"},{"key":"2717_CR5","doi-asserted-by":"publisher","first-page":"1537","DOI":"10.1097\/TA.0b013e3181efb1d1","volume":"69","author":"R Zdero","year":"2010","unstructured":"Zdero R, Keast-Butler O, Schemitsch EH (2010) A biomechanical comparison of two triple-screw methods for femoral neck fracture fixation in a synthetic bone model. J Trauma 69:1537\u20131544. https:\/\/doi.org\/10.1097\/TA.0b013e3181efb1d1","journal-title":"J Trauma"},{"key":"2717_CR6","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.1007\/s00590-018-2207-x","volume":"28","author":"V Giordano","year":"2018","unstructured":"Giordano V, Paes RP, Alves DD et al (2018) Stability of L-shaped and inverted triangle fixation assemblies in treating Pauwels type II femoral neck fracture: a comparative mechanical study. Eur J Orthop Surg Traumatol 28:1359\u20131367. https:\/\/doi.org\/10.1007\/s00590-018-2207-x","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2717_CR7","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1097\/BOT.0000000000001461","volume":"33","author":"JC Hoffmann","year":"2019","unstructured":"Hoffmann JC, Kellam J, Kumaravel M et al (2019) Is the cranial and posterior screw of the \u201cinverted triangle\u201d configuration for femoral neck fractures safe? J Orthop Trauma 33:331\u2013334. https:\/\/doi.org\/10.1097\/BOT.0000000000001461","journal-title":"J Orthop Trauma"},{"key":"2717_CR8","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1302\/0301-620X.82B5.10426","volume":"82","author":"E Gautier","year":"2000","unstructured":"Gautier E, Ganz K, Krugel N et al (2000) Anatomy of the medial femoral circumflex artery and its surgical implications. J Bone Jt Surg Ser B 82:679\u2013683. https:\/\/doi.org\/10.1302\/0301-620X.82B5.10426","journal-title":"J Bone Jt Surg Ser B"},{"key":"2717_CR9","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/j.injury.2010.10.005","volume":"42","author":"T-W Huang","year":"2011","unstructured":"Huang T-W, Hsu W-H, Peng K-T, Lee C-Y (2011) Effect of integrity of the posterior cortex in displaced femoral neck fractures on outcome after surgical fixation in young adults. Injury 42:217\u2013222. https:\/\/doi.org\/10.1016\/j.injury.2010.10.005","journal-title":"Injury"},{"key":"2717_CR10","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1097\/BOT.0000000000001263","volume":"32","author":"JA Parry","year":"2018","unstructured":"Parry JA, Barrett I, Schoch B et al (2018) Validation of neck-shaft angle correction after cephalomedullary nail fixation. J Orthop Trauma 32:505\u2013507. https:\/\/doi.org\/10.1097\/BOT.0000000000001263","journal-title":"J Orthop Trauma"},{"key":"2717_CR11","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1007\/BF00578828","volume":"7","author":"P Nikiforidis","year":"1997","unstructured":"Nikiforidis P, Babis GC, Papaioannou N et al (1997) The role of primary total hip replacement for the treatment of the displaced femoral neck fractures. Eur J Orthop Surg Traumatol 7:23\u201326. https:\/\/doi.org\/10.1007\/BF00578828","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2717_CR12","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1097\/00003086-200206000-00012","volume":"399","author":"FG-C Bachiller","year":"2002","unstructured":"Bachiller FG-C, Caballer AP, Portal LF (2002) Avascular necrosis of the femoral head after femoral neck fracture. Clin Orthop Relat Res 399:87\u2013109. https:\/\/doi.org\/10.1097\/00003086-200206000-00012","journal-title":"Clin Orthop Relat Res"},{"key":"2717_CR13","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-020-02668-5","author":"WR Aibinder","year":"2020","unstructured":"Aibinder WR, Yuan BJ, Cross WW, Parry JA (2020) Sequential fluoroscopic rollover images reliably identify \u201cin\u2013out\u2013in\u201d posterosuperior screws during percutaneous fixation of femoral neck fractures. Eur J Orthop Surg Traumatol. https:\/\/doi.org\/10.1007\/s00590-020-02668-5","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2717_CR14","doi-asserted-by":"publisher","first-page":"61","DOI":"10.2106\/JBJS.K.01081","volume":"95","author":"JJ Yang","year":"2013","unstructured":"Yang JJ, Lin LC, Chao KH et al (2013) Risk factors for nonunion in patients with intracapsular femoral neck fractures treated with three cannulated screws placed in either a triangle or an inverted triangle configuration. J Bone Jt Surg Ser A 95:61\u201369. https:\/\/doi.org\/10.2106\/JBJS.K.01081","journal-title":"J Bone Jt Surg Ser A"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-020-02717-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-020-02717-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-020-02717-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,14]],"date-time":"2021-06-14T23:43:06Z","timestamp":1623714186000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-020-02717-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,15]]},"references-count":14,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["2717"],"URL":"https:\/\/doi.org\/10.1007\/s00590-020-02717-z","relation":{},"ISSN":["1633-8065","1432-1068"],"issn-type":[{"value":"1633-8065","type":"print"},{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,15]]},"assertion":[{"value":"4 February 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"No external source of funding. A. Sems receives royalties from Biomet. No other authors have a COI.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}