{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T11:23:40Z","timestamp":1740137020963,"version":"3.37.3"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2020,8,17]],"date-time":"2020-08-17T00:00:00Z","timestamp":1597622400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,8,17]],"date-time":"2020-08-17T00:00:00Z","timestamp":1597622400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"published-print":{"date-parts":[[2021,2]]},"DOI":"10.1007\/s00590-020-02762-8","type":"journal-article","created":{"date-parts":[[2020,8,17]],"date-time":"2020-08-17T10:03:10Z","timestamp":1597658590000},"page":"259-264","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Trochanteric fixation nail advanced with helical blade and cement augmentation: early experience with a retrospective cohort"],"prefix":"10.1007","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6941-5701","authenticated-orcid":false,"given":"L. Henry","family":"Goodnough","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Harsh","family":"Wadhwa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seth S.","family":"Tigchelaar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Malcolm R.","family":"DeBaun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael J.","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julius A.","family":"Bishop","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael J.","family":"Gardner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,8,17]]},"reference":[{"key":"2762_CR1","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1097\/TA.0b013e31829a2c43","volume":"75","author":"W Liu","year":"2013","unstructured":"Liu W, Zhou D, Liu F et al (2013) Mechanical complications of intertrochanteric hip fractures treated with trochanteric femoral nails. J Trauma Acute Care Surg 75:304\u2013310. https:\/\/doi.org\/10.1097\/TA.0b013e31829a2c43","journal-title":"J Trauma Acute Care Surg"},{"key":"2762_CR2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000001730","author":"JA Parry","year":"2020","unstructured":"Parry JA, Sapp T, Langford JR et al (2020) Variables associated with lag screw sliding after single-screw cephalomedullary nail fixation of intertrochanteric fractures. J Orthop Trauma. https:\/\/doi.org\/10.1097\/BOT.0000000000001730","journal-title":"J Orthop Trauma"},{"key":"2762_CR3","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1097\/BOT.0000000000000961","volume":"31","author":"D Ciufo","year":"2017","unstructured":"Ciufo D, Zaruta D, Lipof J et al (2017) Risk factors associated with cephalomedullary nail cutout in the treatment of trochanteric hip fractures. J Orthop Trauma 31:583\u2013588. https:\/\/doi.org\/10.1097\/BOT.0000000000000961","journal-title":"J Orthop Trauma"},{"key":"2762_CR4","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1097\/BOT.0000000000000853","volume":"31","author":"LC Stern","year":"2017","unstructured":"Stern LC, Gorczyca JT, Kates S et al (2017) Radiographic review of helical blade versus lag screw fixation for cephalomedullary nailing of low-energy peritrochanteric femur fractures: there is a difference in cutout. J Orthop Trauma 31:305\u2013310. https:\/\/doi.org\/10.1097\/BOT.0000000000000853","journal-title":"J Orthop Trauma"},{"key":"2762_CR5","doi-asserted-by":"publisher","first-page":"926","DOI":"10.1016\/j.injury.2019.02.015","volume":"50","author":"I Ibrahim","year":"2019","unstructured":"Ibrahim I, Appleton PT, Wixted JJ et al (2019) Implant cut-out following cephalomedullary nailing of intertrochanteric femur fractures: are helical blades to blame? Injury 50:926\u2013930. https:\/\/doi.org\/10.1016\/j.injury.2019.02.015","journal-title":"Injury"},{"key":"2762_CR6","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.2106\/00004623-199507000-00012","volume":"77","author":"MR Baumgaertner","year":"1995","unstructured":"Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 77:1058\u20131064. https:\/\/doi.org\/10.2106\/00004623-199507000-00012","journal-title":"J Bone Joint Surg Am"},{"key":"2762_CR7","doi-asserted-by":"publisher","first-page":"1312","DOI":"10.1016\/j.injury.2010.08.009","volume":"41","author":"A Lobo-Escolar","year":"2010","unstructured":"Lobo-Escolar A, Joven E, Iglesias D, Herrera A (2010) Predictive factors for cutting-out in femoral intramedullary nailing. Injury 41:1312\u20131316. https:\/\/doi.org\/10.1016\/j.injury.2010.08.009","journal-title":"Injury"},{"key":"2762_CR8","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1007\/s00264-009-0866-2","volume":"34","author":"K-K Hsueh","year":"2010","unstructured":"Hsueh K-K, Fang C-K, Chen C-M et al (2010) Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients. Int Orthop 34:1273\u20131276. https:\/\/doi.org\/10.1007\/s00264-009-0866-2","journal-title":"Int Orthop"},{"key":"2762_CR9","doi-asserted-by":"publisher","first-page":"2701","DOI":"10.1007\/s00198-013-2392-8","volume":"24","author":"L Konstantinidis","year":"2013","unstructured":"Konstantinidis L, Papaioannou C, Blanke P et al (2013) Failure after osteosynthesis of trochanteric fractures. Where is the limit of osteoporosis? Osteoporos Int 24:2701\u20132706. https:\/\/doi.org\/10.1007\/s00198-013-2392-8","journal-title":"Osteoporos Int"},{"key":"2762_CR10","doi-asserted-by":"publisher","first-page":"153","DOI":"10.3109\/17453679608994661","volume":"67","author":"J Choueka","year":"1996","unstructured":"Choueka J, Koval KJ, Kummer FJ, Zukerman JD (1996) Cement augmentation of intertrochanteric fracture fixation: a cadaver comparison of 2 techniques. Acta Orthop Scand 67:153\u2013157. https:\/\/doi.org\/10.3109\/17453679608994661","journal-title":"Acta Orthop Scand"},{"key":"2762_CR11","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1097\/00005131-200008000-00002","volume":"14","author":"S Elder","year":"2000","unstructured":"Elder S, Frankenburg E, Goulet J et al (2000) Biomechanical evaluation of calcium phosphate cement-augmented fixation of unstable intertrochanteric fractures. J Orthop Trauma 14:386\u2013393. https:\/\/doi.org\/10.1097\/00005131-200008000-00002","journal-title":"J Orthop Trauma"},{"key":"2762_CR12","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1007\/s00402-012-1677-2","volume":"133","author":"S Namdari","year":"2013","unstructured":"Namdari S, Rabinovich R, Scolaro J et al (2013) Absorbable and non-absorbable cement augmentation in fixation of intertrochanteric femur fractures: systematic review of the literature. Arch Orthop Trauma Surg 133:487\u2013494. https:\/\/doi.org\/10.1007\/s00402-012-1677-2","journal-title":"Arch Orthop Trauma Surg"},{"key":"2762_CR13","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1097\/TA.0b013e3181c995ec","volume":"68","author":"P-C Lee","year":"2010","unstructured":"Lee P-C, Hsieh P-H, Chou Y-C et al (2010) Dynamic hip screws for unstable intertrochanteric fractures in elderly patients\u2014encouraging results with a cement augmentation technique. J Trauma 68:954\u2013964. https:\/\/doi.org\/10.1097\/TA.0b013e3181c995ec","journal-title":"J Trauma"},{"key":"2762_CR14","doi-asserted-by":"publisher","first-page":"215145932091212","DOI":"10.1177\/2151459320912121","volume":"11","author":"N Kulachote","year":"2020","unstructured":"Kulachote N, Sa-Ngasoongsong P, Sirisreetreerux N et al (2020) Predicting factors for return to prefracture ambulatory level in high surgical risk elderly patients sustained intertrochanteric fracture and treated with proximal femoral nail antirotation (PFNA) with and without cement augmentation. Geriatr Orthop Surg Rehabil 11:2151459320912121. https:\/\/doi.org\/10.1177\/2151459320912121","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"2762_CR15","doi-asserted-by":"publisher","first-page":"2021","DOI":"10.1007\/s00198-018-4572-z","volume":"29","author":"S-J Kim","year":"2018","unstructured":"Kim S-J, Park H-S, Lee D-W, Lee J-W (2018) Is calcium phosphate augmentation a viable option for osteoporotic hip fractures? Osteoporos Int 29:2021\u20132028. https:\/\/doi.org\/10.1007\/s00198-018-4572-z","journal-title":"Osteoporos Int"},{"key":"2762_CR16","doi-asserted-by":"publisher","first-page":"1484","DOI":"10.1016\/j.injury.2011.07.010","volume":"42","author":"C Kammerlander","year":"2011","unstructured":"Kammerlander C, Gebhard F, Meier C et al (2011) Standardised cement augmentation of the PFNA using a perforated blade: a new technique and preliminary clinical results. A prospective multicentre trial. Injury 42:1484\u20131490. https:\/\/doi.org\/10.1016\/j.injury.2011.07.010","journal-title":"Injury"},{"key":"2762_CR17","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1007\/s00402-013-1902-7","volume":"134","author":"C Kammerlander","year":"2014","unstructured":"Kammerlander C, Doshi H, Gebhard F et al (2014) Long-term results of the augmented PFNA: a prospective multicenter trial. Arch Orthop Trauma Surg 134:343\u2013349. https:\/\/doi.org\/10.1007\/s00402-013-1902-7","journal-title":"Arch Orthop Trauma Surg"},{"key":"2762_CR18","doi-asserted-by":"publisher","first-page":"1436","DOI":"10.1016\/j.injury.2018.04.022","volume":"49","author":"C Kammerlander","year":"2018","unstructured":"Kammerlander C, Hem ES, Klopfer T et al (2018) Cement augmentation of the proximal femoral nail antirotation (PFNA)\u2014a multicentre randomized controlled trial. Injury 49:1436\u20131444. https:\/\/doi.org\/10.1016\/j.injury.2018.04.022","journal-title":"Injury"},{"key":"2762_CR19","doi-asserted-by":"publisher","unstructured":"Yee DKH. Cementation: for better or worse? Interim results of a multi-centre cohort study using a fenestrated spiral blade cephalomedullary device for pertrochanteric fractures in the elderly. Arch Orthop Trauma Surg 8:32335758. https:\/\/doi.org\/10.1007\/s00402-020-03449-9","DOI":"10.1007\/s00402-020-03449-9"},{"key":"2762_CR20","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1007\/s00402-016-2447-3","volume":"136","author":"M Hanke","year":"2016","unstructured":"Hanke M, Djonov V, Tannast M et al (2016) Prevention of cement leakage into the hip joint by a standard cement plug during PFN-A cement augmentation: a technical note. Arch Orthop Trauma Surg 136:747\u2013750. https:\/\/doi.org\/10.1007\/s00402-016-2447-3","journal-title":"Arch Orthop Trauma Surg"},{"issue":"Suppl 1","key":"2762_CR21","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","volume":"32","author":"EG Meinberg","year":"2018","unstructured":"Meinberg EG, Agel J, Roberts CS et al (2018) Fracture and dislocation classification compendium-2018. J Orthop Trauma 32(Suppl 1):S1\u2013S170. https:\/\/doi.org\/10.1097\/BOT.0000000000001063","journal-title":"J Orthop Trauma"},{"key":"2762_CR22","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","volume":"21","author":"JL Marsh","year":"2007","unstructured":"Marsh JL, Slongo TF, Agel J et al (2007) Fracture and dislocation classification compendium-2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 21:S1\u2013133","journal-title":"J Orthop Trauma"},{"key":"2762_CR23","unstructured":"Introduction: fracture and dislocation classification compen...\u202f: J Orthop Trauma. https:\/\/journals.lww.com\/jorthotrauma\/Fulltext\/2018\/01001\/Introduction__Fracture_and_Dislocation.1.aspx. Accessed 5 Mar 2019"},{"key":"2762_CR24","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1097\/BTO.0000000000000070","volume":"29","author":"Y Wu","year":"2014","unstructured":"Wu Y, Watson J, Kuldjanov D, Jackman J (2014) Rotationally stable fixation for intertrochanteric hip fractures: the intertan experience, surgical technique, and outcomes. Tech Orthop 29:120\u2013132. https:\/\/doi.org\/10.1097\/BTO.0000000000000070","journal-title":"Tech Orthop"},{"key":"2762_CR25","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1097\/BOT.0000000000000967","volume":"31","author":"R Serrano","year":"2017","unstructured":"Serrano R, Blair JA, Watson DT et al (2017) Cephalomedullary nail fixation of intertrochanteric femur fractures: are two proximal screws better than one? J Orthop Trauma 31:577\u2013582. https:\/\/doi.org\/10.1097\/BOT.0000000000000967","journal-title":"J Orthop Trauma"},{"key":"2762_CR26","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1097\/00003086-199010000-00019","volume":"259","author":"S Larsson","year":"1990","unstructured":"Larsson S, Friberg S, Hansson LI (1990) Trochanteric fractures. Influence of reduction and implant position on impaction and complications. Clin Orthop Relat Res 259:130\u2013139","journal-title":"Clin Orthop Relat Res"},{"key":"2762_CR27","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1097\/BOT.0000000000001193","volume":"32","author":"T Chapman","year":"2018","unstructured":"Chapman T, Zmistowski B, Krieg J et al (2018) Helical blade versus screw fixation in the treatment of hip fractures with cephalomedullary devices: incidence of failure and atypical \u201cmedial cutout\u201d. J Orthop Trauma 32:397\u2013402. https:\/\/doi.org\/10.1097\/BOT.0000000000001193","journal-title":"J Orthop Trauma"},{"key":"2762_CR28","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1097\/BOT.0000000000001509","volume":"33","author":"MJ Ricci","year":"2019","unstructured":"Ricci MJ, McAndrew CM, Miller AN et al (2019) Are two-part intertrochanteric femur fractures stable and does stability depend on fixation method? J Orthop Trauma 33:428\u2013431. https:\/\/doi.org\/10.1097\/BOT.0000000000001509","journal-title":"J Orthop Trauma"},{"key":"2762_CR29","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.1016\/j.injury.2007.03.014","volume":"38","author":"MJ Gardner","year":"2007","unstructured":"Gardner MJ, Briggs SM, Kopjar B et al (2007) Radiographic outcomes of intertrochanteric hip fractures treated with the trochanteric fixation nail. Injury 38:1189\u20131196. https:\/\/doi.org\/10.1016\/j.injury.2007.03.014","journal-title":"Injury"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-020-02762-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-020-02762-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-020-02762-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,7]],"date-time":"2022-11-07T12:37:56Z","timestamp":1667824676000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-020-02762-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,17]]},"references-count":29,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["2762"],"URL":"https:\/\/doi.org\/10.1007\/s00590-020-02762-8","relation":{},"ISSN":["1633-8065","1432-1068"],"issn-type":[{"type":"print","value":"1633-8065"},{"type":"electronic","value":"1432-1068"}],"subject":[],"published":{"date-parts":[[2020,8,17]]},"assertion":[{"value":"13 May 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 August 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Each author certifies that he or she has no commercial associations (e.g., consultancies, stock ownership, equity interest, patent\/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by our institution\u2019s IRB. Trochanteric Fixation Nail Advanced With Helical Blade and Cement Augmentation: Early Experience with a Retrospective Cohort.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}