{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:13:04Z","timestamp":1792782784813,"version":"4.5.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T00:00:00Z","timestamp":1609718400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T00:00:00Z","timestamp":1609718400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"CNPQ"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"published-print":{"date-parts":[[2021,8]]},"DOI":"10.1007\/s00590-020-02856-3","type":"journal-article","created":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T06:04:23Z","timestamp":1609740263000},"page":"1113-1120","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Direct detection of microorganisms in sonicated orthopedic devices after in vitro biofilm production and different processing conditions"],"prefix":"10.1007","volume":"31","author":[{"given":"Juliette","family":"Cieslinski","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victoria Stadler Tasca","family":"Ribeiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Let\u00edcia","family":"Kraft","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paula Hansen","family":"Suss","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edvaldo","family":"Rosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luis Gustavo","family":"Morello","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcelo","family":"Pillonetto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3471-1786","authenticated-orcid":false,"given":"Felipe Francisco","family":"Tuon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,1,4]]},"reference":[{"key":"2856_CR1","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1128\/JCM.00006-10","volume":"48","author":"Y Achermann","year":"2010","unstructured":"Achermann Y, Vogt M, Leunig M, Wust J, Trampuz A (2010) Improved diagnosis of periprosthetic joint infection by multiplex PCR of sonication fluid from removed implants. J Clin Microbiol 48:1208\u20131214. https:\/\/doi.org\/10.1128\/JCM.00006-10","journal-title":"J Clin Microbiol"},{"key":"2856_CR2","first-page":"2932","volume":"36","author":"BL Atkins","year":"1998","unstructured":"Atkins BL et al (1998) Prospective evaluation of criteria for microbiological diagnosis of prosthetic-joint infection at revision arthroplasty. OSIRIS Collab Study Group J Clin Microbiol 36:2932\u20132939","journal-title":"OSIRIS Collab Study Group J Clin Microbiol"},{"key":"2856_CR3","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.bjid.2017.03.007","volume":"21","author":"MG Barberino","year":"2017","unstructured":"Barberino MG, Silva MO, Arraes ACP, Correia LC, Mendes AV (2017) Direct identification from positive blood broth culture by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry MALDI-TOF MS. Braz J Infect Dis 21:339\u2013342. https:\/\/doi.org\/10.1016\/j.bjid.2017.03.007","journal-title":"Braz J Infect Dis"},{"key":"2856_CR4","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1016\/j.jiph.2016.05.011","volume":"10","author":"AM Bazzi","year":"2017","unstructured":"Bazzi AM, Rabaan AA, El Edaily Z, John S, Fawarah MM, Al-Tawfiq JA (2017) Comparison among four proposed direct blood culture microbial identification methods using MALDI-TOF MS J Infect. Public Health 10:308\u2013315. https:\/\/doi.org\/10.1016\/j.jiph.2016.05.011","journal-title":"Public Health"},{"key":"2856_CR5","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1016\/j.tim.2011.06.004","volume":"19","author":"BR Boles","year":"2011","unstructured":"Boles BR, Horswill AR (2011) Staphylococcal biofilm disassembly. Trends Microbiol 19:449\u2013455. https:\/\/doi.org\/10.1016\/j.tim.2011.06.004","journal-title":"Trends Microbiol"},{"key":"2856_CR6","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1373\/clinchem.2008.112797","volume":"55","author":"SA Bustin","year":"2009","unstructured":"Bustin SA et al (2009) The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. Clin Chem 55:611\u2013622. https:\/\/doi.org\/10.1373\/clinchem.2008.112797","journal-title":"Clin Chem"},{"key":"2856_CR7","doi-asserted-by":"publisher","first-page":"2280","DOI":"10.1128\/JCM.00335-13","volume":"51","author":"C Cazanave","year":"2013","unstructured":"Cazanave C et al (2013) Rapid molecular microbiologic diagnosis of prosthetic joint infection. J Clin Microbiol 51:2280\u20132287. https:\/\/doi.org\/10.1128\/JCM.00335-13","journal-title":"J Clin Microbiol"},{"key":"2856_CR8","doi-asserted-by":"publisher","first-page":"1733","DOI":"10.1128\/JCM.03259-12","volume":"51","author":"JH Chen","year":"2013","unstructured":"Chen JH et al (2013) Direct bacterial identification in positive blood cultures by use of two commercial matrix-assisted laser desorption ionization-time of flight mass spectrometry systems. J Clin Microbiol 51:1733\u20131739. https:\/\/doi.org\/10.1128\/JCM.03259-12","journal-title":"J Clin Microbiol"},{"key":"2856_CR9","doi-asserted-by":"publisher","DOI":"10.1128\/JCM.00688-18","author":"M Dudareva","year":"2018","unstructured":"Dudareva M et al (2018) Sonication versus tissue sampling for diagnosis of prosthetic joint and other orthopedic device-related infections. J Clin Microbiol. https:\/\/doi.org\/10.1128\/JCM.00688-18","journal-title":"J Clin Microbiol"},{"key":"2856_CR10","doi-asserted-by":"publisher","first-page":"2110","DOI":"10.1128\/JCM.02215-09","volume":"48","author":"L Ferreira","year":"2010","unstructured":"Ferreira L, Sanchez-Juanes F, Gonzalez-Avila M, Cembrero-Fucinos D, Herrero-Hernandez A, Gonzalez-Buitrago JM, Munoz-Bellido JL (2010) Direct identification of urinary tract pathogens from urine samples by matrix-assisted laser desorption ionization-time of flight mass spectrometry. J Clin Microbiol 48:2110\u20132115. https:\/\/doi.org\/10.1128\/JCM.02215-09","journal-title":"J Clin Microbiol"},{"key":"2856_CR11","doi-asserted-by":"publisher","DOI":"10.1128\/microbiolspec.MB-0016-2014","author":"MJ Franklin","year":"2015","unstructured":"Franklin MJ, Chang C, Akiyama T, Bothner B (2015) New technologies for studying biofilms. Microbiol Spectr. https:\/\/doi.org\/10.1128\/microbiolspec.MB-0016-2014","journal-title":"Microbiol Spectr"},{"key":"2856_CR12","doi-asserted-by":"publisher","first-page":"3501","DOI":"10.1128\/JCM.00834-12","volume":"50","author":"E Gomez","year":"2012","unstructured":"Gomez E et al (2012) Prosthetic joint infection diagnosis using broad-range PCR of biofilms dislodged from knee and hip arthroplasty surfaces using sonication. J Clin Microbiol 50:3501\u20133508. https:\/\/doi.org\/10.1128\/JCM.00834-12","journal-title":"J Clin Microbiol"},{"key":"2856_CR13","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1016\/j.jfda.2019.01.001","volume":"27","author":"TY Hou","year":"2019","unstructured":"Hou TY, Chiang-Ni C, Teng SH (2019) Current status of MALDI-TOF mass spectrometry in clinical microbiology. J Food Drug Anal 27:404\u2013414. https:\/\/doi.org\/10.1016\/j.jfda.2019.01.001","journal-title":"J Food Drug Anal"},{"key":"2856_CR14","doi-asserted-by":"publisher","first-page":"16","DOI":"10.22203\/eCM.v037a02","volume":"37","author":"S Karbysheva","year":"2019","unstructured":"Karbysheva S, Grigoricheva L, Golnik V, Popov S, Renz N, Trampuz A (2019) Influence of retrieved hip- and knee-prosthesis biomaterials on microbial detection by sonication. Eur Cell Mater 37:16\u201322. https:\/\/doi.org\/10.22203\/eCM.v037a02","journal-title":"Eur Cell Mater"},{"key":"2856_CR15","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1099\/jmm.0.032284-0","volume":"61","author":"HL Kohling","year":"2012","unstructured":"Kohling HL et al (2012) Direct identification of bacteria in urine samples by matrix-assisted laser desorption\/ionization time-of-flight mass spectrometry and relevance of defensins as interfering factors. J Med Microbiol 61:339\u2013344. https:\/\/doi.org\/10.1099\/jmm.0.032284-0","journal-title":"J Med Microbiol"},{"key":"2856_CR16","doi-asserted-by":"publisher","first-page":"e72349","DOI":"10.1371\/journal.pone.0072349","volume":"8","author":"AJ Loonen","year":"2013","unstructured":"Loonen AJ et al (2013) Comparison of pathogen DNA isolation methods from large volumes of whole blood to improve molecular diagnosis of bloodstream infections. PLoS One 8:e72349. https:\/\/doi.org\/10.1371\/journal.pone.0072349","journal-title":"PLoS One"},{"key":"2856_CR17","first-page":"6","volume":"38","author":"SC Marques","year":"2007","unstructured":"Marques SC (2007) Formation of biofilms by Staphylococcus aureus on stainless steel and glass surfaces and its resistance to some selected chemical sanitizers Braz. J Microbiol 38:6","journal-title":"J Microbiol"},{"key":"2856_CR18","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.diagmicrobio.2017.10.016","volume":"90","author":"C Morgenstern","year":"2018","unstructured":"Morgenstern C, Cabric S, Perka C, Trampuz A, Renz N (2018) Synovial fluid multiplex PCR is superior to culture for detection of low-virulent pathogens causing periprosthetic joint infection. Diagn Microbiol Infect Dis 90:115\u2013119. https:\/\/doi.org\/10.1016\/j.diagmicrobio.2017.10.016","journal-title":"Diagn Microbiol Infect Dis"},{"key":"2856_CR19","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.mimet.2012.04.015","volume":"90","author":"A Nocker","year":"2012","unstructured":"Nocker A, Fernandez PS, Montijn R, Schuren F (2012) Effect of air drying on bacterial viability: a multiparameter viability assessment. J Microbiol Methods 90:86\u201395. https:\/\/doi.org\/10.1016\/j.mimet.2012.04.015","journal-title":"J Microbiol Methods"},{"key":"2856_CR20","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1093\/cid\/cis803","volume":"56","author":"DR Osmon","year":"2013","unstructured":"Osmon DR et al (2013) Diagnosis and management of prosthetic joint infection: clinical practice guidelines by the infectious diseases society of America. Clin Infect Dis 56:e1\u2013e25. https:\/\/doi.org\/10.1093\/cid\/cis803","journal-title":"Clin Infect Dis"},{"key":"2856_CR21","doi-asserted-by":"publisher","first-page":"1878","DOI":"10.1128\/JCM.01686-08","volume":"47","author":"KE Piper","year":"2009","unstructured":"Piper KE et al (2009) Microbiologic diagnosis of prosthetic shoulder infection by use of implant sonication. J Clin Microbiol 47:1878\u20131884. https:\/\/doi.org\/10.1128\/JCM.01686-08","journal-title":"J Clin Microbiol"},{"key":"2856_CR22","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1093\/icb\/45.5.800","volume":"45","author":"M Potts","year":"2005","unstructured":"Potts M, Slaughter SM, Hunneke FU, Garst JF, Helm RF (2005) Desiccation tolerance of prokaryotes: application of principles to human cells. Integr Comp Biol 45:800\u2013809. https:\/\/doi.org\/10.1093\/icb\/45.5.800","journal-title":"Integr Comp Biol"},{"key":"2856_CR23","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1007\/s15010-017-1073-5","volume":"45","author":"N Renz","year":"2017","unstructured":"Renz N, Feihl S, Cabric S, Trampuz A (2017) Performance of automated multiplex PCR using sonication fluid for diagnosis of periprosthetic joint infection: a prospective cohort. Infection 45:877\u2013884. https:\/\/doi.org\/10.1007\/s15010-017-1073-5","journal-title":"Infection"},{"key":"2856_CR24","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1016\/j.injury.2018.02.018","volume":"49","author":"N Renz","year":"2018","unstructured":"Renz N, Cabric S, Morgenstern C, Schuetz MA, Trampuz A (2018) Value of PCR in sonication fluid for the diagnosis of orthopedic hardware-associated infections: has the molecular era arrived? Injury 49:806\u2013811. https:\/\/doi.org\/10.1016\/j.injury.2018.02.018","journal-title":"Injury"},{"key":"2856_CR25","doi-asserted-by":"publisher","first-page":"1827","DOI":"10.1007\/s11999-017-5315-8","volume":"475","author":"AC Rothenberg","year":"2017","unstructured":"Rothenberg AC, Wilson AE, Hayes JP, O\u2019Malley MJ, Klatt BA (2017) Sonication of arthroplasty implants improves accuracy of periprosthetic joint infection cultures. Clin Orthop Relat Res 475:1827\u20131836. https:\/\/doi.org\/10.1007\/s11999-017-5315-8","journal-title":"Clin Orthop Relat Res"},{"key":"2856_CR26","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1016\/j.diagmicrobio.2014.03.021","volume":"79","author":"SY Ryu","year":"2014","unstructured":"Ryu SY, Greenwood-Quaintance KE, Hanssen AD, Mandrekar JN, Patel R (2014) Low sensitivity of periprosthetic tissue PCR for prosthetic knee infection diagnosis. Diagn Microbiol Infect Dis 79:448\u2013453. https:\/\/doi.org\/10.1016\/j.diagmicrobio.2014.03.021","journal-title":"Diagn Microbiol Infect Dis"},{"key":"2856_CR27","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1097\/BRS.0b013e3181c3b2f3","volume":"35","author":"MF Sampedro","year":"2010","unstructured":"Sampedro MF et al (2010) A biofilm approach to detect bacteria on removed spinal implants. Spine (Phila Pa) 35:1218\u20131224. https:\/\/doi.org\/10.1097\/BRS.0b013e3181c3b2f3","journal-title":"Spine (Phila Pa)"},{"key":"2856_CR28","doi-asserted-by":"publisher","first-page":"2334","DOI":"10.1128\/JCM.00462-17","volume":"55","author":"TL Street","year":"2017","unstructured":"Street TL et al (2017) Molecular diagnosis of orthopedic-device-related infection directly from sonication fluid by metagenomic sequencing. J Clin Microbiol 55:2334\u20132347. https:\/\/doi.org\/10.1128\/JCM.00462-17","journal-title":"J Clin Microbiol"},{"key":"2856_CR29","doi-asserted-by":"publisher","first-page":"1571","DOI":"10.1099\/jmm.0.000837","volume":"67","author":"VS Tasca Ribeiro","year":"2018","unstructured":"Tasca Ribeiro VS et al (2018) Conventional culture method and qPCR using 16S rDNA for tissue bank: a comparison using a model of cardiac tissue contamination. J Med Microbiol 67:1571\u20131575. https:\/\/doi.org\/10.1099\/jmm.0.000837","journal-title":"J Med Microbiol"},{"key":"2856_CR30","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1056\/NEJMoa061588","volume":"357","author":"A Trampuz","year":"2007","unstructured":"Trampuz A et al (2007) Sonication of removed hip and knee prostheses for diagnosis of infection. N Engl J Med 357:654\u2013663. https:\/\/doi.org\/10.1056\/NEJMoa061588","journal-title":"N Engl J Med"},{"key":"2856_CR31","doi-asserted-by":"publisher","first-page":"3281","DOI":"10.1128\/JCM.37.10.3281-3290.1999","volume":"37","author":"MM Tunney","year":"1999","unstructured":"Tunney MM et al (1999) Detection of prosthetic hip infection at revision arthroplasty by immunofluorescence microscopy and PCR amplification of the bacterial 16S rRNA gene. J Clin Microbiol 37:3281\u20133290","journal-title":"J Clin Microbiol"},{"key":"2856_CR32","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1007\/s00264-018-4076-7","volume":"43","author":"FF Tuon","year":"2019","unstructured":"Tuon FF et al (2019) Microbiological profile and susceptibility pattern of surgical site infections related to orthopaedic trauma. Int Orthop 43:1309\u20131313. https:\/\/doi.org\/10.1007\/s00264-018-4076-7","journal-title":"Int Orthop"},{"key":"2856_CR33","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.1016\/j.arth.2019.02.020","volume":"34","author":"N Ueda","year":"2019","unstructured":"Ueda N, Oe K, Nakamura T, Tsuta K, Iida H, Saito T (2019) Sonication of extracted implants improves microbial detection in patients with orthopedic implant-associated infections. J Arthroplast 34:1189\u20131196. https:\/\/doi.org\/10.1016\/j.arth.2019.02.020","journal-title":"J Arthroplast"},{"key":"2856_CR34","doi-asserted-by":"publisher","first-page":"3449","DOI":"10.1128\/jcm.40.9.3449-3454.2002","volume":"40","author":"S Yang","year":"2002","unstructured":"Yang S, Lin S, Kelen GD, Quinn TC, Dick JD, Gaydos CA, Rothman RE (2002) Quantitative multiprobe PCR assay for simultaneous detection and identification to species level of bacterial pathogens. J Clin Microbiol 40:3449\u20133454. https:\/\/doi.org\/10.1128\/jcm.40.9.3449-3454.2002","journal-title":"J Clin Microbiol"},{"key":"2856_CR35","doi-asserted-by":"publisher","first-page":"506","DOI":"10.7727\/wimj.2016.179","volume":"64","author":"L Zhao","year":"2015","unstructured":"Zhao L, Ashraf MA (2015) Influence of Silver-hydroxyapatite nanocomposite coating on biofilm formation of joint prosthesis and its mechanism. West Indian Med J 64:506\u2013513. https:\/\/doi.org\/10.7727\/wimj.2016.179","journal-title":"West Indian Med J"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-020-02856-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-020-02856-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-020-02856-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,15]],"date-time":"2021-07-15T11:10:06Z","timestamp":1626347406000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-020-02856-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,4]]},"references-count":35,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,8]]}},"alternative-id":["2856"],"URL":"https:\/\/doi.org\/10.1007\/s00590-020-02856-3","relation":{},"ISSN":["1633-8065","1432-1068"],"issn-type":[{"value":"1633-8065","type":"print"},{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,4]]},"assertion":[{"value":"14 November 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Author declares no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"In vitro study\u2014N\/A.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"In vitro study\u2014N\/A.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human or animal rights"}},{"value":"In vitro study\u2014N\/A.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}