{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T02:34:41Z","timestamp":1769913281691,"version":"3.49.0"},"reference-count":66,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2021,4,14]],"date-time":"2021-04-14T00:00:00Z","timestamp":1618358400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,4,14]],"date-time":"2021-04-14T00:00:00Z","timestamp":1618358400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"published-print":{"date-parts":[[2021,7]]},"DOI":"10.1007\/s00590-021-02969-3","type":"journal-article","created":{"date-parts":[[2021,4,15]],"date-time":"2021-04-15T05:55:47Z","timestamp":1618466147000},"page":"861-869","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Biomechanics of periprosthetic femur fractures and early weightbearing"],"prefix":"10.1007","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2250-8310","authenticated-orcid":false,"given":"Ansab","family":"Khwaja","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William","family":"Mahoney","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jay","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alex","family":"Trompeter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jason","family":"Lowe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,4,14]]},"reference":[{"issue":"4","key":"2969_CR1","doi-asserted-by":"publisher","first-page":"780","DOI":"10.2106\/00004623-200704000-00012","volume":"89","author":"S Kurtz","year":"2007","unstructured":"Kurtz S et al (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone JtSurg Am 89(4):780\u2013785","journal-title":"J Bone JtSurg Am"},{"issue":"10","key":"2969_CR2","doi-asserted-by":"publisher","first-page":"2005","DOI":"10.1007\/s00264-015-2979-0","volume":"39","author":"MP Abdel","year":"2015","unstructured":"Abdel MP, Cottino U, Mabry TM (2015) Management of periprosthetic femoral fractures following total hip arthroplasty: a review. Int Orthop 39(10):2005\u20132010","journal-title":"Int Orthop"},{"issue":"4","key":"2969_CR3","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1615\/JLongTermEffMedImplants.2015012625","volume":"25","author":"R Pivec","year":"2015","unstructured":"Pivec R et al (2015) Incidence and future projections of periprosthetic femoral fracture following primary total hip arthroplasty: an analysis of international registry data. J Long Term Eff Med Implants 25(4):269\u2013275","journal-title":"J Long Term Eff Med Implants"},{"issue":"2","key":"2969_CR4","doi-asserted-by":"publisher","first-page":"189","DOI":"10.11138\/ccmbm\/2017.14.1.189","volume":"14","author":"A Capone","year":"2017","unstructured":"Capone A et al (2017) Periprosthetic fractures: epidemiology and current treatment. Clin Cases Miner Bone Metab 14(2):189\u2013196","journal-title":"Clin Cases Miner Bone Metab"},{"issue":"4","key":"2969_CR5","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1302\/0301-620X.98B4.37203","volume":"98-B","author":"MP Abdel","year":"2016","unstructured":"Abdel MP et al (2016) Epidemiology of periprosthetic femoral fractures in 5417 revision total hip arthroplasties: a 40-year experience. Bone Jt J 98-B(4):468\u2013474","journal-title":"Bone Jt J"},{"issue":"7","key":"2969_CR6","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1302\/0301-620X.101B7.BJJ-2018-1422.R1","volume":"101-B","author":"JN Lamb","year":"2019","unstructured":"Lamb JN et al (2019) A calcar collar is protective against early periprosthetic femoral fracture around cementless femoral components in primary total hip arthroplasty: a registry study with biomechanical validation. Bone Jt J 101-B(7):779\u2013786","journal-title":"Bone Jt J"},{"issue":"10","key":"2969_CR7","doi-asserted-by":"publisher","first-page":"1909","DOI":"10.1007\/s00264-015-2967-4","volume":"39","author":"S Frenzel","year":"2015","unstructured":"Frenzel S, Vecsei V, Negrin L (2015) Periprosthetic femoral fractures\u2013incidence, classification problems and the proposal of a modified classification scheme. Int Orthop 39(10):1909\u20131920","journal-title":"Int Orthop"},{"issue":"1 Supple A","key":"2969_CR8","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1302\/0301-620X.99B1.BJJ-2016-0220.R1","volume":"99-B","author":"AV Carli","year":"2017","unstructured":"Carli AV, Negus JJ, Haddad FS (2017) Periprosthetic femoral fractures and trying to avoid them: what is the contribution of femoral component design to the increased risk of periprosthetic femoral fracture? Bone Jt J 99-B(1 Supple A):50\u201359","journal-title":"Bone Jt J"},{"issue":"9","key":"2969_CR9","doi-asserted-by":"publisher","first-page":"558","DOI":"10.1302\/2058-5241.5.200003","volume":"5","author":"A Ramavath","year":"2020","unstructured":"Ramavath A et al (2020) Postoperative periprosthetic femoral fracture around total hip replacements: current concepts and clinical outcomes. EFORT Open Rev 5(9):558\u2013567","journal-title":"EFORT Open Rev"},{"issue":"7","key":"2969_CR10","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1016\/j.arth.2005.02.001","volume":"20","author":"H Lindahl","year":"2005","unstructured":"Lindahl H et al (2005) Periprosthetic femoral fractures classification and demographics of 1049 periprosthetic femoral fractures from the Swedish national hip arthroplasty register. J Arthroplasty 20(7):857\u2013865","journal-title":"J Arthroplasty"},{"issue":"6","key":"2969_CR11","doi-asserted-by":"publisher","first-page":"1283","DOI":"10.1016\/j.arth.2015.11.038","volume":"31","author":"JM Drew","year":"2016","unstructured":"Drew JM et al (2016) Survivorship after periprosthetic femur fracture: factors affecting outcome. J Arthroplasty 31(6):1283\u20131288","journal-title":"J Arthroplasty"},{"issue":"4","key":"2969_CR12","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1016\/j.arth.2014.11.006","volume":"30","author":"B Fuchtmeier","year":"2015","unstructured":"Fuchtmeier B, Galler M, Muller F (2015) Mid-term results of 121 periprosthetic femoral fractures: increased failure and mortality within but not after one postoperative year. J Arthroplasty 30(4):669\u2013674","journal-title":"J Arthroplasty"},{"issue":"7","key":"2969_CR13","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1007\/s00402-011-1272-y","volume":"131","author":"HL Laurer","year":"2011","unstructured":"Laurer HL et al (2011) Outcome after operative treatment of Vancouver type B1 and C periprosthetic femoral fractures: open reduction and internal fixation versus revision arthroplasty. Arch Orthop Trauma Surg 131(7):983\u2013989","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"2969_CR14","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1097\/BOT.0b013e31821d6f55","volume":"26","author":"R Langenhan","year":"2012","unstructured":"Langenhan R et al (2012) Aggressive surgical treatment of periprosthetic femur fractures can reduce mortality: comparison of open reduction and internal fixation versus a modular prosthesis nail. J Orthop Trauma 26(2):80\u201385","journal-title":"J Orthop Trauma"},{"issue":"12","key":"2969_CR15","doi-asserted-by":"publisher","first-page":"2658","DOI":"10.2106\/JBJS.F.01538","volume":"89","author":"T Bhattacharyya","year":"2007","unstructured":"Bhattacharyya T et al (2007) Mortality after periprosthetic fracture of the femur. J Bone JtSurg Am 89(12):2658\u20132662","journal-title":"J Bone JtSurg Am"},{"issue":"10","key":"2969_CR16","first-page":"2240","volume":"87","author":"WM Ricci","year":"2005","unstructured":"Ricci WM et al (2005) Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. J Bone JtSurg Am 87(10):2240\u20132245","journal-title":"J Bone JtSurg Am"},{"issue":"3","key":"2969_CR17","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1097\/BOT.0000000000000282","volume":"29","author":"WM Ricci","year":"2015","unstructured":"Ricci WM (2015) Periprosthetic femur fractures. J Orthop Trauma 29(3):130\u2013137","journal-title":"J Orthop Trauma"},{"issue":"10","key":"2969_CR18","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1097\/BOT.0000000000001265","volume":"32","author":"AB Christ","year":"2018","unstructured":"Christ AB et al (2018) Radiographic and clinical outcomes of periprosthetic distal femur fractures treated with open reduction internal fixation. J Orthop Trauma 32(10):515\u2013520","journal-title":"J Orthop Trauma"},{"issue":"7","key":"2969_CR19","doi-asserted-by":"publisher","first-page":"941","DOI":"10.1007\/s00402-014-2003-y","volume":"134","author":"JW Kim","year":"2014","unstructured":"Kim JW, Byun SE, Chang JS (2014) The clinical outcomes of early internal fixation for undisplaced femoral neck fractures and early full weight-bearing in elderly patients. Arch Orthop Trauma Surg 134(7):941\u2013946","journal-title":"Arch Orthop Trauma Surg"},{"issue":"12","key":"2969_CR20","doi-asserted-by":"publisher","first-page":"727","DOI":"10.5435\/00124635-201312000-00003","volume":"21","author":"EN Kubiak","year":"2013","unstructured":"Kubiak EN et al (2013) Early weight bearing after lower extremity fractures in adults. J Am Acad Orthop Surg 21(12):727\u2013738","journal-title":"J Am Acad Orthop Surg"},{"issue":"7","key":"2969_CR21","doi-asserted-by":"publisher","first-page":"1419","DOI":"10.1007\/s00590-019-02453-z","volume":"29","author":"J Warren","year":"2019","unstructured":"Warren J et al (2019) The association between weight-bearing status and early complications in hip fractures. Eur J Orthop Surg Traumatol 29(7):1419\u20131427","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"2","key":"2969_CR22","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/j.arth.2018.09.088","volume":"34","author":"CS Ottesen","year":"2019","unstructured":"Ottesen CS et al (2019) Acceptable success rate in patients with periprosthetic knee joint infection treated with debridement, antibiotics, and implant retention. J Arthroplasty 34(2):365\u2013368","journal-title":"J Arthroplasty"},{"issue":"8","key":"2969_CR23","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1097\/PHM.0000000000000075","volume":"93","author":"P Ariza-Vega","year":"2014","unstructured":"Ariza-Vega P, Jimenez-Moleon JJ, Kristensen MT (2014) Non-weight-bearing status compromises the functional level up to 1 yr after hip fracture surgery. Am J Phys Med Rehabil 93(8):641\u2013648","journal-title":"Am J Phys Med Rehabil"},{"issue":"3","key":"2969_CR24","doi-asserted-by":"publisher","first-page":"125","DOI":"10.5371\/hp.2020.32.3.125","volume":"32","author":"KJ Lee","year":"2020","unstructured":"Lee KJ, Um SH, Kim YH (2020) Postoperative rehabilitation after hip fracture: a literature review. Hip Pelvis 32(3):125\u2013131","journal-title":"Hip Pelvis"},{"key":"2969_CR25","first-page":"215145931982643","volume":"10","author":"T Kenyon-Smith","year":"2019","unstructured":"Kenyon-Smith T et al (2019) Early mobilization post-hip fracture surgery. GeriatrOrthopSurgRehabil 10:2151459319826431","journal-title":"GeriatrOrthopSurgRehabil"},{"issue":"2","key":"2969_CR26","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1111\/j.1447-0594.2012.00904.x","volume":"13","author":"AJ Vochteloo","year":"2013","unstructured":"Vochteloo AJ et al (2013) More than half of hip fracture patients do not regain mobility in the first postoperative year. Geriatr Gerontol Int 13(2):334\u2013341","journal-title":"Geriatr Gerontol Int"},{"issue":"6","key":"2969_CR27","first-page":"1389","volume":"67","author":"LA Taitsman","year":"2009","unstructured":"Taitsman LA et al (2009) Risk factors for femoral nonunion after femoral shaft fracture. J Trauma 67(6):1389\u20131392","journal-title":"J Trauma"},{"key":"2969_CR28","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1097\/00003086-199308000-00003","volume":"293","author":"HT Aro","year":"1993","unstructured":"Aro HT, Chao EY (1993) Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression. Clin Orthop Relat Res 293:8\u201317","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"2969_CR29","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s00402-013-1883-6","volume":"134","author":"GB Moloney","year":"2014","unstructured":"Moloney GB et al (2014) Treatment of periprosthetic femur fractures around a well-fixed hip arthroplasty implant: span the whole bone. Arch Orthop Trauma Surg 134(1):9\u201314","journal-title":"Arch Orthop Trauma Surg"},{"issue":"11","key":"2969_CR30","doi-asserted-by":"publisher","first-page":"936","DOI":"10.2106\/JBJS.17.01222","volume":"100","author":"C Kammerlander","year":"2018","unstructured":"Kammerlander C et al (2018) Inability of older adult patients with hip fracture to maintain postoperative weight-bearing restrictions. J Bone JtSurg Am 100(11):936\u2013941","journal-title":"J Bone JtSurg Am"},{"issue":"9","key":"2969_CR31","doi-asserted-by":"publisher","first-page":"1253","DOI":"10.1007\/s00402-019-03193-9","volume":"139","author":"D Pfeufer","year":"2019","unstructured":"Pfeufer D et al (2019) Weight-bearing restrictions reduce postoperative mobility in elderly hip fracture patients. Arch Orthop Trauma Surg 139(9):1253\u20131259","journal-title":"Arch Orthop Trauma Surg"},{"issue":"8","key":"2969_CR32","doi-asserted-by":"publisher","first-page":"1507","DOI":"10.1007\/s00264-017-3481-7","volume":"41","author":"BJ Braun","year":"2017","unstructured":"Braun BJ et al (2017) Weight-bearing recommendations after operative fracture treatment-fact or fiction? Gait results with and feasibility of a dynamic, continuous pedobarography insole. Int Orthop 41(8):1507\u20131512","journal-title":"Int Orthop"},{"issue":"2","key":"2969_CR33","doi-asserted-by":"publisher","first-page":"109","DOI":"10.5535\/arm.2020.44.2.109","volume":"44","author":"H Seo","year":"2020","unstructured":"Seo H et al (2020) Factors affecting compliance with weight-bearing restriction and the amount of weight-bearing in the elderly with femur or pelvic fractures. Ann Rehabil Med 44(2):109\u2013116","journal-title":"Ann Rehabil Med"},{"issue":"Suppl 6","key":"2969_CR34","doi-asserted-by":"publisher","first-page":"S33","DOI":"10.1097\/BOT.0000000000001566","volume":"33","author":"GJ Haidukewych","year":"2019","unstructured":"Haidukewych GJ (2019) Role of distal femoral replacement for periprosthetic fractures above a total knee arthroplasty: When and how? J Orthop Trauma 33(Suppl 6):S33\u2013S35","journal-title":"J Orthop Trauma"},{"issue":"1","key":"2969_CR35","doi-asserted-by":"publisher","first-page":"21","DOI":"10.5301\/hip.2011.6301","volume":"21","author":"G Pavlou","year":"2011","unstructured":"Pavlou G et al (2011) A review of 202 periprosthetic fractures\u2013stem revision and allograft improves outcome for type B fractures. Hip Int 21(1):21\u201329","journal-title":"Hip Int"},{"key":"2969_CR36","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1186\/1749-799X-5-45","volume":"5","author":"JP Lever","year":"2010","unstructured":"Lever JP et al (2010) The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty. J Orthop Surg Res 5:45","journal-title":"J Orthop Surg Res"},{"issue":"Suppl 6","key":"2969_CR37","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1097\/BOT.0000000000001569","volume":"33","author":"EB Gausden","year":"2019","unstructured":"Gausden EB, Wellman DS (2019) Biomechanics of periprosthetic fixation: plates, nails, cables, and allografts. J Orthop Trauma 33(Suppl 6):S1\u2013S4","journal-title":"J Orthop Trauma"},{"issue":"8","key":"2969_CR38","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1097\/00005131-199911000-00006","volume":"13","author":"C Krettek","year":"1999","unstructured":"Krettek C et al (1999) The mechanical effect of blocking screws (\u201cPoller screws\u201d) in stabilizing tibia fractures with short proximal or distal fragments after insertion of small-diameter intramedullary nails. J Orthop Trauma 13(8):550\u2013553","journal-title":"J Orthop Trauma"},{"issue":"6","key":"2969_CR39","doi-asserted-by":"publisher","first-page":"1123","DOI":"10.1016\/j.arth.2012.01.013","volume":"27","author":"MG Bourke","year":"2012","unstructured":"Bourke MG et al (2012) A comparison of patellar vascularity between the medial parapatellar and subvastus approaches in total knee arthroplasty. J Arthroplasty 27(6):1123-1127.e1","journal-title":"J Arthroplasty"},{"issue":"11","key":"2969_CR40","doi-asserted-by":"publisher","first-page":"1180","DOI":"10.1016\/j.injury.2009.02.017","volume":"40","author":"GK Bryant","year":"2009","unstructured":"Bryant GK et al (2009) Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures. Injury 40(11):1180\u20131186","journal-title":"Injury"},{"issue":"12","key":"2969_CR41","doi-asserted-by":"publisher","first-page":"1949","DOI":"10.1016\/j.injury.2013.03.008","volume":"44","author":"EJ Griffiths","year":"2013","unstructured":"Griffiths EJ et al (2013) Time to surgery and 30-day morbidity and mortality of periprosthetic hip fractures. Injury 44(12):1949\u20131952","journal-title":"Injury"},{"key":"2969_CR42","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s13037-016-0114-9","volume":"10","author":"WR Smith","year":"2016","unstructured":"Smith WR et al (2016) Is immediate weight bearing safe for periprosthetic distal femur fractures treated by locked plating? A feasibility study in 52 consecutive patients. Patient Saf Surg 10:26","journal-title":"Patient Saf Surg"},{"issue":"Suppl 2","key":"2969_CR43","doi-asserted-by":"publisher","first-page":"S82","DOI":"10.1097\/BOT.0b013e31821b8a09","volume":"25","author":"A Nauth","year":"2011","unstructured":"Nauth A et al (2011) Periprosthetic distal femur fractures: current concepts. J Orthop Trauma 25(Suppl 2):S82\u2013S85","journal-title":"J Orthop Trauma"},{"issue":"4","key":"2969_CR44","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/S0883-5403(96)80024-6","volume":"11","author":"MA Ritter","year":"1996","unstructured":"Ritter MA et al (1996) Patellofemoral complications following total knee arthroplasty. Effect of a lateral release and sacrifice of the superior lateral geniculate artery. J Arthroplasty 11(4):368\u2013372","journal-title":"J Arthroplasty"},{"issue":"3","key":"2969_CR45","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1016\/S0883-5403(87)80039-6","volume":"2","author":"G Scuderi","year":"1987","unstructured":"Scuderi G et al (1987) The relationship of lateral releases to patella viability in total knee arthroplasty. J Arthroplasty 2(3):209\u2013214","journal-title":"J Arthroplasty"},{"issue":"7","key":"2969_CR46","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1054\/arth.2002.34817","volume":"17","author":"MR Bong","year":"2002","unstructured":"Bong MR et al (2002) Comparison of the LISS and a retrograde-inserted supracondylar intramedullary nail for fixation of a periprosthetic distal femur fracture proximal to a total knee arthroplasty. J Arthroplasty 17(7):876\u2013881","journal-title":"J Arthroplasty"},{"issue":"8","key":"2969_CR47","doi-asserted-by":"publisher","first-page":"1639","DOI":"10.1016\/j.arth.2013.07.027","volume":"29","author":"SM Thompson","year":"2014","unstructured":"Thompson SM et al (2014) Periprosthetic supracondylar femoral fractures above a total knee replacement: compatibility guide for fixation with a retrograde intramedullary nail. J Arthroplasty 29(8):1639\u20131641","journal-title":"J Arthroplasty"},{"issue":"6","key":"2969_CR48","doi-asserted-by":"publisher","first-page":"e237","DOI":"10.1097\/BOT.0000000000001154","volume":"32","author":"MS Hussain","year":"2018","unstructured":"Hussain MS, Dailey SK, Avilucea FR (2018) Stable fixation and immediate weight-bearing after combined retrograde intramedullary nailing and open reduction internal fixation of noncomminuted distal interprosthetic femur fractures. J Orthop Trauma 32(6):e237\u2013e240","journal-title":"J Orthop Trauma"},{"issue":"3","key":"2969_CR49","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1016\/j.arth.2013.08.010","volume":"29","author":"M Moazen","year":"2014","unstructured":"Moazen M et al (2014) Periprosthetic femoral fracture\u2014a biomechanical comparison between Vancouver type B1 and B2 fixation methods. J Arthroplasty 29(3):495\u2013500","journal-title":"J Arthroplasty"},{"issue":"7","key":"2969_CR50","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1016\/j.injury.2014.02.038","volume":"45","author":"MF Hoffmann","year":"2014","unstructured":"Hoffmann MF et al (2014) Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system. Injury 45(7):1035\u20131041","journal-title":"Injury"},{"issue":"8","key":"2969_CR51","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1097\/00005131-200409000-00002","volume":"18","author":"MJ Kaab","year":"2004","unstructured":"Kaab MJ et al (2004) Locked internal fixator: sensitivity of screw\/plate stability to the correct insertion angle of the screw. J Orthop Trauma 18(8):483\u2013487","journal-title":"J Orthop Trauma"},{"issue":"2","key":"2969_CR52","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/S0020-1383(02)00161-4","volume":"34","author":"E Tsiridis","year":"2003","unstructured":"Tsiridis E, Haddad FS, Gie GA (2003) Dall-Miles plates for periprosthetic femoral fractures. A critical review of 16 cases. Injury 34(2):107\u2013110","journal-title":"Injury"},{"issue":"2","key":"2969_CR53","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1097\/01.bot.0000199119.38359.96","volume":"20","author":"E Fulkerson","year":"2006","unstructured":"Fulkerson E et al (2006) Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: a biomechanical comparison of locked plating and conventional cable plates. J Orthop Trauma 20(2):89\u201393","journal-title":"J Orthop Trauma"},{"issue":"12","key":"2969_CR54","doi-asserted-by":"publisher","first-page":"1958","DOI":"10.1016\/j.injury.2014.08.034","volume":"45","author":"D Dargan","year":"2014","unstructured":"Dargan D, Jenkinson MJ, Acton JD (2014) A retrospective review of the Dall-Miles plate for periprosthetic femoral fractures: twenty-seven cases and a review of the literature. Injury 45(12):1958\u20131963","journal-title":"Injury"},{"issue":"3","key":"2969_CR55","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1097\/00005131-200103000-00005","volume":"15","author":"MG Dennis","year":"2001","unstructured":"Dennis MG et al (2001) Fixation of periprosthetic femoral shaft fractures: a biomechanical comparison of two techniques. J Orthop Trauma 15(3):177\u2013180","journal-title":"J Orthop Trauma"},{"issue":"Suppl 1","key":"2969_CR56","doi-asserted-by":"publisher","first-page":"S71","DOI":"10.1016\/j.injury.2013.10.027","volume":"45","author":"M Lenz","year":"2014","unstructured":"Lenz M et al (2014) A biomechanical study on proximal plate fixation techniques in periprosthetic femur fractures. Injury 45(Suppl 1):S71\u2013S75","journal-title":"Injury"},{"issue":"9","key":"2969_CR57","doi-asserted-by":"publisher","first-page":"1964","DOI":"10.2106\/00004623-200709000-00011","volume":"89","author":"MA Buttaro","year":"2007","unstructured":"Buttaro MA et al (2007) Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures. J Bone JtSurg Am 89(9):1964\u20131969","journal-title":"J Bone JtSurg Am"},{"issue":"5","key":"2969_CR58","doi-asserted-by":"publisher","first-page":"1068","DOI":"10.2106\/JBJS.F.01561","volume":"90","author":"R Zdero","year":"2008","unstructured":"Zdero R et al (2008) Biomechanical evaluation of periprosthetic femoral fracture fixation. J Bone JtSurg Am 90(5):1068\u20131077","journal-title":"J Bone JtSurg Am"},{"key":"2969_CR59","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1097\/00003086-200002000-00012","volume":"371","author":"WC Head","year":"2000","unstructured":"Head WC, Malinin TI (2000) Results of onlay allografts. Clin Orthop Relat Res 371:108\u2013112","journal-title":"Clin Orthop Relat Res"},{"issue":"7","key":"2969_CR60","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1016\/S0883-5403(97)90009-7","volume":"12","author":"AJ Hamer","year":"1997","unstructured":"Hamer AJ, Suvarna SK, Stockley I (1997) Histologic evidence of cortical allograft bone incorporation in revision hip surgery. J Arthroplasty 12(7):785\u2013789","journal-title":"J Arthroplasty"},{"key":"2969_CR61","doi-asserted-by":"publisher","first-page":"1413","DOI":"10.1016\/j.arth.2020.10.023","volume":"36","author":"I Ilyas","year":"2020","unstructured":"Ilyas I, Al-Mohrej OA (2020) High incidence of irradiated cortical strut allograft resorption following revision of femoral stems. J Arthroplasty 36:1413","journal-title":"J Arthroplasty"},{"issue":"5","key":"2969_CR62","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1016\/j.arth.2012.12.010","volume":"29","author":"RE Moore","year":"2014","unstructured":"Moore RE et al (2014) A systematic review of open reduction and internal fixation of periprosthetic femur fractures with or without allograft strut, cerclage, and locked plates. J Arthroplasty 29(5):872\u2013876","journal-title":"J Arthroplasty"},{"issue":"4","key":"2969_CR63","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1002\/jor.23065","volume":"34","author":"M Lenz","year":"2016","unstructured":"Lenz M et al (2016) Enhancing fixation strength in periprosthetic femur fractures by orthogonal plating\u2014a biomechanical study. J Orthop Res 34(4):591\u2013596","journal-title":"J Orthop Res"},{"issue":"5","key":"2969_CR64","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1007\/s00776-015-0735-3","volume":"20","author":"SM Graham","year":"2015","unstructured":"Graham SM et al (2015) Periprosthetic femoral fracture fixation: a biomechanical comparison between proximal locking screws and cables. J Orthop Sci 20(5):875\u2013880","journal-title":"J Orthop Sci"},{"issue":"9","key":"2969_CR65","doi-asserted-by":"publisher","first-page":"2921","DOI":"10.1007\/s00167-016-4050-0","volume":"25","author":"YS Shin","year":"2017","unstructured":"Shin YS, Kim HJ, Lee DH (2017) Similar outcomes of locking compression plating and retrograde intramedullary nailing for periprosthetic supracondylar femoral fractures following total knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 25(9):2921\u20132928","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"4","key":"2969_CR66","first-page":"297","volume":"7","author":"NA Ebraheim","year":"2015","unstructured":"Ebraheim NA et al (2015) Periprosthetic distal femur fracture after total knee arthroplasty: a systematic review. OrthopSurg 7(4):297\u2013305","journal-title":"OrthopSurg"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-021-02969-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-021-02969-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-021-02969-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,18]],"date-time":"2022-04-18T05:21:51Z","timestamp":1650259311000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-021-02969-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,14]]},"references-count":66,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021,7]]}},"alternative-id":["2969"],"URL":"https:\/\/doi.org\/10.1007\/s00590-021-02969-3","relation":{},"ISSN":["1633-8065","1432-1068"],"issn-type":[{"value":"1633-8065","type":"print"},{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,14]]},"assertion":[{"value":"14 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 April 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ansab Khwaja MD: None. William Mahoney MD: None. Jay Johnson MD: None. Alex Trompeter: Paid services For R+D with Stryker. Paid services for education and speakers bureau with Stryker, Smith and Nephew, DePuy Synthes, Orthofix. No aspect of this manuscript overlaps with work with those companies. Jason Lowe MD: Active consultant for Stryker Orthopaedics receiving consulting fees and royalties. No aspect of this manuscript overlaps with work within Stryker.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}